Lg As-w243dgu1 Owner's Manual

Room Air Conditioner
SVC MANUAL(Exploded View)
MODEL : AS-W243DGU1
CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel.
Internal Use Only
- 2 -
Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes
LGE Internal Use Only
Note : O : Applie, X : Not applied, – : No relation
• Filters are optional in some specific areas.
• For Circuit Breaker Rating, please conform to local standards whenever nec­essary.
1. Product Specifications
Sales Model LS240HSV
Models Unit AS-W243DGU1
Cooling Capacity
kW 0.90 ~ 6.45 ~ 8.80
Btu/h. 3,070~22,000~30,030
Heating Capacity
kW 0.90 ~ 8.09 ~ 11.40
Btu/h. 3,070~27,600~38,898 Power Input Cooling W 1760 Running Current Cooling/Heating A 7.9 / 10.7 Starting Current Cooling/Heating A 7.9 / 10.7
EER
W/W 3.66
Btu/h.W 12.5 SEER 18.9 HSPF 10.2 Power Supply Ø / V / Hz 1/208-230/60 Power Factor % 96.9
Air Flow Rate
Indoor,Max m3/min(CFM) 25(883) Outdoor,Max m3/min(CFM) 60(2,119)
Moisture Removal l/h. 2.8
Sound Level
Indoor,H/M/L dB(A)±3 46/43/39
Outdoor,Max dB(A)±3 54 Refrigerant & Charge (at 7.5 m) g(oz) R410A, 2,000(70.5) Additional Refrigerant charge g/m(oz/ft) 35(0.38)
Compressor
Type Twin Rotary
Model GJT240DAA
Motor Type Brushless DC Motor
Oil Type PVE(FVD68C)
Oil Charge cc 900
O.L.P. name -
Fan(Indoor)
Type Cross Flow Fan
Motor Output W 76.1
Fan(Outdoor)
Type Propeller
Motor Type BLDC
Motor Output W 124 Circuit Breaker* A25 Power Supply Cable No.*mm2 3*2.5 Power and Transmission Cable No.*mm2 No.*mm2 4*1.0 (Including Earth)
Piping Connections
Liquid Side mm(in) 9.52(3/8)
Gas Side mm(in) 15.88(5/8) Drain Hose(O.D / I.D.) mm(in) 21.5 / 16.0(0.85 / 0.63)
Dimensions
Indoor (W*H*D)
mm 1209*346*205 inch 47-5/8*13-5/8*8-1/16
Outdoor (W*H*D)
mm 870*800*320 inch 34-5/16*31-1/2*12-5/8
Net Weight
Indoor kg(lbs) 18(39.7)
Outdoor kg(lbs) 60(132.3)
Gross Weight
Indoor kg(lbs) 20(44.1)
Outdoor kg(lbs) 64(141.1)
Operation Range
Cooling(Outdoor) °C(℉) -5~48(14~118.4)
Heating(Outdoor) °C(℉) -10(-15)~24(14.0~75.2) Piping Length (Min/Max) m(ft) - / 30(98.4) Chargeless m(ft) ­Max. Elevation Difference m(ft) 15(49.2) Tool Code(Chassis) Indoor + Outdoor SD + UE1+
Functions
Temperature Control Thermistor
Allergy free filter O
Plasma Filter O
Prefilter(washable/anti-fungus) O
Auto Clean O
CHAOS Wind(Auto Wind) O
Steps, Fan/Cool/Heat 3/4/3
Airflow Direction Control(up& Down) Auto
Airflow Direction Control(left & right) Auto
Remote Controller Type Wireless LCD(EZ-Remocon)
Setting Temperature
Range
Cooling 18°C ~ 30°C
Heating 16°C ~ 30°C Auto Operation (Micom Control) ­Auto Changeover (Micom Control) O Self Diagnosis O Timer 24h, On/Off Sleep Operation O Soft Dry Operation O Restart Delay(minute) 3 Deice Control(Defrost)
O Hot Start O Jet Cool O Low Ambient Operation O Special Function -
- 3 -
Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes
LGE Internal Use Only
2. Piping Diagrams
LOC. Description PCB Connector
Th1 Thermistor for suction air temperature
CN-TH1(Indoor)
Th2 Thermistor for evaporator inlet temperature
Th3 Thermistor for evaporator outlet temperature CN-TH2(Indoor)
Th4 Thermistor for evaporator middle temperature CN-TH3(Indoor)
Th5 Thermistor for discharge pipe temperature
CN-TH3(OUTDOOR)
Th6 Thermistor for suction pipe temperature
Th7 Thermistor for condensing temperature
CN-TH2(OUTDOOR)
Th8 Thermistor for outdoor air temperature
Th9 Thermistor for condensing middle temperature CN-TH4(OUTDOOR)
EEV : Electronic Expansion Valve
Indoor Unit Outdoor Unit
Liquid Side
EEV
Heat Exchanger (Condenser)
Th1
Heat Exchanger (Evaporator)
Th2
2-Way Valve
Th4
Th3
Gas Side
3-Way Valve
Accumulator
Th6
Reversing Valve
Th5
Compressor
Th8
Th9
Th7
Cooling
Heating
Loading...