Room Air Conditioner
SVC MANUAL(Exploded View)
MODEL : AUUW366D ( S36AWN )
ASNW36GDGM0 (S36AWN )
CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual.
Only for authorized service personnel.
http://biz.lgservice.com
1. Specification
Models
Cooling Capacity kW
(Min~Rating~Max) Btu/h.
Heating Capacity kW
(Min~Rating~Max) Btu/h.
Power Input Cooling/Heating W
Running Current Cooling/Heating A
Starting Current Cooling/Heating A
EER W/W
Btu/h.W
COP W/W
Power Supply Ø / V / Hz
Power Factor %
Air Flow Rate Indoor,Max m3/min(CFM)
Outdoor,Max m3/min(CFM)
Moisture Removal l/h.
Sound Level Indoor,H/M/L dB(A)±3
Outdoor,Max dB(A)±3
Refrigerant & Charge(at 7.5 m) g(oz)
Additional Refrigerant charge g/m(oz/ft)
Compressor Type
Model
Motor Type
Oil Type
Oil Charge cc
O.L.P. name
Fan(Indoor) Type
Motor Output W
Fan(Outdoor) Type
Motor Type
Motor Output W
Circuit Breaker* A
Power Supply Cable No.*mm
Power and Transmission Cable No.*mm2+No.*mm
Piping Liquid Side mm(in)
Connections Gas Side mm(in)
Drain Hose O.D., I.D. mm(in)
Dimensions Indoor (W*H*D) mm
Outdoor (W*H*D) mm
Net Weight Indoor kg(lbs)
Outdoor kg(lbs)
Operation Range Cooling(Outdoor) °C(°F)
Heating(Outdoor) °C(°F)
Max. Piping Length m(ft)
Max. Elevation Difference m(ft)
Tool Code(Chassis) Indoor + Outdoor
2
inch
inch
ASNW36GDGM0
AUUW366D
9
30709
10.4
35486
2,990/3,540
13.6/16.5
13.6/16.5
3.01
10.27
2.94
1 / 220 ~ 240 / 50
97
21(742)
58(2048)
3.5
48 /44/ 39
58
R410A, 2,200(77.6)
35(0.376)
Rotary
5JD420XAD22
Brushless DC motor
FV50S
1300
CS-7L 115
Cross Flow Fan
70
Propeller
Brushless DC motor
100
25
2
3*2.5
4*0.75
6.35(1/4)
15.88(5/8)
21.5, 16 (0.85, 0.63)
1,209*346*205
47.6*13.6*8.1
870*1060*320
34.3*41.7*12.6
19(41.9)
75(165.3)
-10 ~ 43 (14 ~ 109.4)
-15 ~ 24 (5 ~ 75.2)
50(164)
30(98.4)
SD + UE2
Note:
1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 27°C(80.6°F) DB/19°C(66.2°F) WB
- Outdoor Temperature 35°C(95°F) DB/24°C(75.2°F) WB
Heating: - Indoor Temperature 20°C(68°F) DB/15°C(59°F) WB
- Outdoor Temperature 7°C(44.6°F) DB/6°C(42.8°F) WB
Piping Length - Interconnecting Piping Length 7.5m
- Level Difference of Zero
2 Room Air Conditioner
2. Wiring cable size must comply with the applicable local and national
code.
3. The specification may be subject to change without notic for purpose
of improvement.
2. Function Table
Indoor Unit
FunctionCategory
Air flow Air supply outlet
Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Swirl wind
Air purifying Deodorizing filter
Plasma air purifier
Prefilter(washable / anti-fungus)
Installation Drain pump
E.S.P. control
Electric heater(operation)
High ceiling operation
Reliability Hot start
Self diagnosis
Soft dry operation
Convenience Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Child lock
Forced operation
Group control
Sleep mode
Timer(on/off)
Timer(weekly)
Two thermistor control
Individual Standard wired remote controller
control Deluxe wired remote controller
Simple wired remote controller
Wired remote controller(for hotel use)
Wireless remote controller(simple)
Wireless LCD remote control
CAC network General central controller (Non LGAP)
function Dry contact
Network Soluation(LGAP)
PDI(power distribution indicator)
PI 485
Special Zone control
function kit CTIE
Electro thermostat
Others Thermistor
ASNW36GDGM0
1
Auto
Auto
O
O
4/5/4
O
O
O
X
O
O
O
X
-
-
X
O
O
O
O
O
O
O
X
O
X
O
O
X
X
X
X
X
X
AHWRHD
X
X
X
X
X
X
X
X
X
X
Note :
• O: Applied, • X: Not applied, • - : No relation,
• Option: Model name & price are different according to options, and assembled in factory with main unit.
• Accessory: Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package.
Service Manual 3