Ceiling Concealed Duct - High Static Type Indoor Unit Installation Manual

TABLE OF CONTENTS

Installation Requirements

 

Required Parts

 

Required Tools

 

 

 

 

 

 

 

Features...................................

3

 

 

 

 

 

Safety Precautions.................

4

 

 

 

 

 

Installation...............................

7

 

 

 

ο Level gauge

 

 

 

 

ο Four type "A" screws

 

ο Screw driver

 

Selection the best location

7

 

ο Connecting cable

 

ο Electric drill

 

 

 

 

ο Hole core drill

Ceiling opening dimension

 

 

ο Pipes: Gas side

 

ο Flaring tool set

and hanging bolt location ......

8

 

Liquid side

 

ο Specified torque wrenches

 

 

 

(Refer to Product

 

(different depending on model No.)

 

 

 

Data)

 

ο Spanner .......

Half union

Indoor Unit Installation...........

9

 

ο Insulation materials

 

 

 

 

 

 

ο Additional drain pipe

 

 

 

Wiring Connection .................

9

Checking the Drainage........

10

Dip Switch Setting ...............

13

Group Control Setting..........

14

οA glass of water

οScrew driver

οHexagonal wrench

οGas-leak detector

οVacuum pump

οGauge manifold

οOwner's manual

οThermometer

How to Set E.S.P?

................19

2 Indoor Unit

LG ARNU48GBRA2 INSTALLATION INSTRUCTIONS

Feature

Features

<![if ! IE]>

<![endif]>ENGLISH

Air outlet vents

Air filters

Air intake vents

Wired Remote Controller

Name

Drain hose

Clamp metal

Washer for

Clamp

Insulation for

(Other)

hanging backet

(Tie Wrap)

fitting

 

 

 

 

Quantity

1 EA

2 EA

8 EA

4 EA

1 SET

 

 

 

 

 

 

 

• Owner's manual

 

 

 

 

 

 

• Installation manual

Shape

 

 

 

 

for gas pipe

 

 

 

 

 

 

for liquid pipe

 

Installation Manual 3

Safety Precautions

Safety Precautions

To prevent injury to the user or other people and property damage, the following instructions must be followed.

νBe sure to read before installing the air conditioner.

νBe sure to observe the cautions specified here as they include important items related to safety.

νIncorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications.

This symbol indicates the possibility of death or serious injury.

This symbol indicates the possibility of injury or damage to properties only.

ν Meanings of symbols used in this manual are as shown below.

Be sure not to do.

Be sure to follow the instruction.

ν Installation

Do not use a defective or underrated circuit breaker. Use this appliance on a dedicated circuit.

There is risk of fire or electric shock.

Install the panel and the cover of control box securely.

There is risk of fire or electric shock.

For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center.

Do not disassemble or repair the product. There is risk of fire or electric shock.

Always install a dedicated circuit and breaker.

Improper wiring or installation may cause fire or electric shock.

Always ground the product.

There is risk of fire or electric shock.

Use the correctly rated breaker or fuse.

There is risk of fire or electric shock.

4 Indoor Unit

 

 

Safety Precautions

Do not modify or extend the

Do not let the air conditioner

Be cautious when unpacking

power cable.

run for a long time when the

and installing the product.

 

humidity is very high and a

 

 

door or a window is left open.

 

• There is risk of fire or electric

• Moisture may condense and

• Sharp edges could cause

shock.

wet or damage furniture.

injury. Be especially careful of

 

 

the case edges and the fins

 

 

on the condenser and evapo-

 

 

rator.

For installation, always con-

Do not install the product on

Be sure the installation area

tact the dealer or an

a defective installation stand.

does not deteriorate with age.

Authorized Service Center.

 

 

• There is risk of fire, electric

• It may cause injury, accident,

• If the base collapses, the air

shock, explosion, or injury.

or damage to the product.

conditioner could fall with it,

 

 

causing property damage,

 

 

product failure, and personal

 

 

injury.

<![if ! IE]>

<![endif]>ENGLISH

Use a vacuum pump or Inert (nitrogen) gas when do leakage test or air purge. Do not compress air or Oxygen and do not use Flammable gases. Otherwise, it may cause fire or explosion.

• There is the risk of death, injury, fire or explosion.

ν Operation

Do not store or use flammable gas or combustibles near the product.

• There is risk of fire or failure of product.

Installation Manual 5

Safety Precautions

ν Installation

Always check for gas (refrig-

Install the drain hose to

Keep level even when

erant) leakage after installa-

ensure that water is drained

installing the product.

tion or repair of product.

away properly.

 

Low refrigerant levels may cause failure of product.

• A bad connection may cause

• To avoid vibration or water

water leakage.

leakage.

Do not install the product where the noise or hot air from the outdoor unit could damage the neighborhoods.

Use two or more people to lift and transport the product.

Do not install the product where it will be exposed to sea wind (salt spray) directly.

• It may cause a problem for

• Avoid personal injury.

• It may cause corrosion on the

your neighbors.

 

product. Corrosion, particular-

 

 

ly on the condenser and evap-

 

 

orator fins, could cause prod-

 

 

uct malfunction or inefficient

 

 

operation.

If you eat the liquid from the batteries, brush your teeth and see doctor. Do not use the remote if the batteries have leaked.

• The chemicals in batteries could cause burns or other health hazards.

Make sure to check the rated pressure outside machine and adjust E.S.P value after the installation of the product.

• Otherwise, there is a risk of weak cooling/heating and condensed water emission/dripping.

6 Indoor Unit

Installation

Installation

Read completely, then follow step by step.

Selection of the best location

Install the air conditioner in the location that satisfies the following conditions.

The place shall easily bear a load exceeding four times the indoor unitʼs weight.

The place shall be able to inspect the unit as the figure.

The place where the unit shall be leveled.

The place shall allow easy water drainage.(Suitable dimension “H” is necessary to get a slope to drain as figure.)

The place shall easily connect with the outdoor unit.

The place where the unit is not affected by an electrical noise.

The place where air circulation in the room will be good .

There should not be any heat source or steam near the unit.

Top view

Inspection hole

(unit: mm)

(600X600)

 

Control box

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

600

 

 

 

<![if ! IE]>

<![endif]>1000

 

 

600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Front

Front view

H = 20 or more

CAUTION : In case that the unit is installed near the sea, the installation parts may be corroded by salt, The installation parts (and the unit) should be taken appropriate anti-corrosion measures.

[Inspection Hole Standard]

Number of

Distance between

Remarks

Inspection hole

False ceiling & Actual ceiling

 

1

More than 100cm

Sufficient space in the ceiling for servicing.

2

20cm to 100cm

Insufficient space. Difficult for servicing

Hole size should be

Less than 20cm

Minimum height for motor replacement.

more than the size of IDU.

 

 

<![if ! IE]>