LG ARNU183TSA4 INSTALLATION MANUAL

ENGLISH FRANÇAIS
ESPAÑOL
Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring
standards by authorized personnel only.
Please retain this installation manual for future reference after reading it
thoroughly.
Original instruction
INSTALLATION MANUAL
AIR
CONDITIONER
P/NO : MFL68686513
Rev.31_042618
www.lghvac.com
www.lg.com
Copyright © 2018 LG Electronics Inc. All Rights Reserved.
2 Indoor Unit
IMPORTANT!
Please read this instruction sheet completely before installing the product.
This air conditioning system meets strict safety and operating standards. As the installer or service
person, it is an important part of your job to install or service the system so it operates safely and effi-
ciently.
Caution: Improper installation, adjustment, alteration, service or maintenance can void the warranty.The
weight of the condensing unit requires caution and proper handling procedures when lifting or
moving to avoid personal injury. Use care to avoid contact with sharp or pointed edges.
Safety Precautions
• Always wear safety eye wear and work gloves when installing equipment.
• Never assume electrical power is disconnected. Check with meter and equipment.
• Keep hands out of fan areas when power is connected to equipment.
• R-410A causes frostbite burns.
• R-410A is toxic when burned.
Note to installing dealer: The Owners Instructions and Warranty are to be given to the owner or promi-
nently displayed near the indoor Furnace/Air Handler Unit.
When wiring:
Electrical shock can cause severe personal injury or death. Only a qualified, experienced electrician
should attempt to wire this system.
• Do not supply power to the unit until all wiring and tubing are completed or reconnected and checked.
• Highly dangerous electrical voltages are used in this system. Carefully refer to the wiring diagram and these
instructions when wiring. Improper connections and inadequate grounding can cause accidental injury or death.
• Ground the unit following local electrical codes.
• Connect all wiring tightly. Loose wiring may cause overheating at connection points and a possible fire hazard.
When transporting:
Be careful when picking up and moving the indoor and outdoor units. Get a partner to help, and bend your knees
when lifting to reduce strain on your back. Sharp edges or thin aluminum fins on the air conditioner can cut your
finger.
When installing...
... in a wall: Make sure the wall is strong enough to hold the unit's weight. It may be necessary to construct a
strong wood or metal frame to provide added support.
... in a room: Properly insulate any tubing run inside a room to prevent "sweating" that can cause dripping and
water damage to wall and floors.
... in moist or uneven locatinons: Use a raised concrete pad or concrete blocks provide a solid, level foundation
for the outdoor unit. This prevents water damage and abnormal vibration.
... in an area with high winds: Securely anchor the outdoor unit down with bolts and a metal frame. Provide a
suitable air baffle.
... in a snowy area(for Heat Pump Model): Install the outdoor unit on a raised platform that is higher than drifting
snow. Provide snow vents.
When connecting refrigerant tubing:
• Keep all tubing runs as short as possible.
• Use the flare method for connecting tubing.
• Check carefully for leaks before starting the test run.
When servicing:
• Turn the power OFF at the main power box(mains) before opening the unit to check or repair electrical parts and
wiring.
• Keep your fingers and clothing away from any moving parts.
• Clean up the site after you finish, remembering to check that no metal scraps or bits of wiring have been left
inside the unit being serviced.
• The information contained in the manual is intended for use by a qualified service technician familiar
with safety procedures and equipped with the proper tools and test instruments.
• Failure to carefully read and follow all instructions in this manual can result in equipment malfunc-
tion, property damage, personal injury and/or death.
WARNING
WARNING
Installation Manual 3
Table of contents
ENGLISH
4 INSTALLATION PARTS
5 SAFETY PRECAUTIONS
7 INSTALLATION
7 Selection of the best location
8 Ceiling dimension and hanging bolt location
9 Wiring Connection
10 Installation of Decoration Panel
11 Plumbing materials and storage methods
12 Drain Piping
14 Dip Switch Setting
15 Group Control Setting
20 Model Designation
20 Airborne Noise Emission
20 Limiting concentration
TABLE OF CONTENTS
4 Indoor Unit
Installation Parts
Air Outlet
Air Intake
Wired Remote Controller
(Accessory)
Anti-bacteria filter
Installation Parts
Name Drain hose
Clamp
metal
Washer for
hanging
bracket
Clamp
(Tie Wrap)
Insulation
for
fitting
Conduit
mounting
plate
Quantity
1 EA 2 EA 8 set 4 EA 1 EA 1 EA
Shape
• Screws for fixing panels are attached to decoration panel.
for gas pipe
for liquid pipe
(Other)
Paper pattern
for installation
• Owner's manual
• Installation
manual
Installation Tool
Installation Manual 5
ENGLISH
Safety Precautions
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed.
n Be sure to read before installing the air conditioner.
n Be sure to observe the cautions specified here as they include important items related to safety.
n Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the
following indications.
n Meanings of symbols used in this manual are as shown below.
WARNING
CAUTION
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
Be sure not to do.
Be sure to follow the instruction.
WARNING
Installation
• Do not use a defective or underrated circuit breaker. Use this appliance on a dedicated circuit.
- There is risk of fire or electric shock.
• For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center.
- Do not disassemble or repair the product. There is risk of fire or electric shock.
• Always ground the product.
- There is risk of fire or electric shock.
• Install the panel and the cover of control box securely.
- There is risk of fire or electric shock.
• Always install a dedicated circuit and breaker.
- Improper wiring or installation may cause fire or electric shock.
• Use the correctly rated breaker or fuse.
- There is risk of fire or electric shock.
• Do not modify or extend the power cable.
- There is risk of fire or electric shock.
• Do not let the air conditioner run for a long time when the humidity is very high and a door or a
window is left open.
- Moisture may condense and wet or damage furniture.
• Be cautious when unpacking and installing the product.
- Sharp edges could cause injury. Be especially careful of the case edges and the fins on the
condenser and evaporator.
• For installation, always contact the dealer or an Authorized Service Center.
- There is risk of fire, electric shock, explosion, or injury.
• Do not install the product on a defective installation stand.
- It may cause injury, accident, or damage to the product.
6 Indoor Unit
Safety Precautions
• Be sure the installation area does not deteriorate with age.
- If the base collapses, the air conditioner could fall with it, causing property damage, product failure,
and personal injury.
• Use a vacuum pump or inert (nitrogen) gas when doing leakage test or air purge. Do not compress air
or oxygen, and do not use flammable gases. Otherwise, it may cause fire or explosion.
- There is the risk of death, injury, fire or explosion.
• Do not turn on the breaker or power under condition that front panel, cabinet, top cover, control box
cover are removed or opened.
- Otherwise, it may cause fire, electric shock, explosion or death.
Operation
• Do not store or use flammable gas or combustibles near the product.
- There is risk of fire or failure of product.
Installation
• Always check for gas (refrigerant) leakage after installation or repair of product.
- Low refrigerant levels may cause failure of product.
• Install the drain hose to ensure that water is drained away properly.
- A bad connection may cause water leakage.
• Keep level even when installing the product.
- To avoid vibration or water leakage.
• Use two or more people to lift and transport the product.
- Avoid personal injury.
CAUTION
Loading...