LG APNH2433LAE User Manual

Floor Standing Air Conditioner
SVC MANUAL(Exploded View)
MODEL : APNH2433LAE[LFN246HV]
CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel.
Internal Use Only
- 2 -
Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes
LGE Internal Use Only
Specifications
Power Supply Ø / V / Hz Cooling Capacity kW
Btu/h
Heating Capacity kW
Btu/h Current Nominal Running Current A Fan Motor Type
Fan Type Motor Output(W) x No. of Unit Air Flow Rate(H / M / L) CMM
cfm External Static Pressure mmAq Capacitor μF / Vac
Coil Row x Column x FPI Dimensions Body mm(inch) (W x H x D) Decorative Panel mm(inch) Net Weight Body kg (lbs)
Decorative Panel kg (lbs)
Air Filter Sound Level (H / M / L) dB(A)+3 Piping Connections
Liquid mm (inch) Gas mm (inch)
Dehumidification Rate
l/h Safety Devices Temperature Sensor Referigerant Referigerant Control Connectable Outdoor Unit Power and Transmission Interunit Cable No. x AWG
Model
APNH2433LAE
1 / 208-230 / 60
7.03
24000
7.6
26000
10.9
OBM-4011U1
Turbo Fan
70x1
20/16.5/13
706/583/459
-
220/450
2R x 30C x 18
570x1820x320(22.4x71.6x12.6)
-
43(94.8)
-
Long life filter
45/42/40
9.52(3/8)
15.88(5/8)
-
Thermal protector for fan motor
Thermistor
R-410A
EEV(Outdoor Unit)
LUU245HV
4 x 18
Note :
1. Capacities are based on the following conditions: Cooling - Indoor temperature 27°C(80.6°F)DB/19°C(66.2°F)WB
- Outdoor temperature 35°C(95°F)DB/ 24°C(75.2°F)WB
Heating - Indoor temperature 20°C(68°F)DB/ 15°C(59°F)WB
- Outdoor temperature 7°C(44.6°F)DB/ 6°C(42.8°F)WB
Piping Length - Interconnecting Piping Length 7.5m
- Level Difference of Zero
2. Wiring cable size must comply with the applicable local and national code.
3. The specification may be subject to change without prior notice for purpose of improvement.
1. Specifications
Indoor Unit
- 3 -
Copyright ©2010 LG Electronics. Inc. All right reserved. Only for training and service purposes
LGE Internal Use Only
Function Table
2. Function Table
Air supply outlet Airflow direction control(left & right) Airflow direction control(up & down) Auto swing(left & right) Auto swing(up & down)
Air flow Airflow steps(fan/cool/heat/Plasma)
Chaos swing Chaos wind(auto wind) Jet cool(Power wind) Swirl wind Deodorizing filter
Air purifying Plasma air purifier
Prefilter(washable / anti-fungus) Drain pump
Installation E.S.P. control
Electric heater(operation) High ceiling operation Hot start
Reliability Self diagnosis
Soft dry operation Auto changeover Auto cleaning Auto operation(artificial intelligence) Auto restart operation Child lock
Convenience Forced operation
Group control Sleep mode Timer(on/off) Timer(weekly) Two thermistor control Standard wired remote controller Deluxe wired remote controller
Individual control Simple wired remote controller
Wired remote controller(for hotel use) Wireless remote controller(simple) Wireless LCD remote control General central controller (Non LGAP) Dry contact
CAC network function Network Soluation(LGAP)
PDI(power distribution indicator) PI 485 Zone control
Special function kit CTIE
Electro thermostat
Others Thermistor
Category Function
APNH2433LAE
3 O O O O
3/3/3/1
X O O X O O O X X O X O O O O X X O O O O X O X O X X X X X
O(New)
X X X X X X X X X
Note:
O : Applied X : Not applied - : No relation Option : Model name & price are different according to options, and assembled in factory with main unit. Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package