INSTALLATION MANUAL

AIR

CONDITIONER

Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

Please retain this installation manual for future reference after reading it thoroughly.

Cassette 1-Way

MFL67855404

www.lg.com

Rev.01_091718

Copyright © 2015 - 2018 LG Electronics Inc. All Rights Reserved.

CONTENTS

 

Installation Parts ........................................................................................................................

3

Important Safety Instructions ..................................................................................................

4

Installation ..................................................................................................................................

7

Selection of the Best Location ..................................................................................................

7

Ceiling Dimension and Hanging Bolt Location..........................................................................

8

Installation of Decoration Panel (Grille Type) ..........................................................................

9

Drain Piping ............................................................................................................................

10

Wiring Connection ..................................................................................................................

11

Installation of Wired Remote Controller..................................................................................

13

DIP Switch Setting..................................................................................................................

16

2 Indoor Unit

LG AMNC09GTUA0 INSTALLATION MANUAL

Installation Parts

Installation Parts

Grille type

Outlet

 

 

 

 

 

or

 

 

 

 

Inlet

Wired remote

Wireless remote

 

 

 

 

 

 

controller

 

controller

 

 

 

(optional)

 

 

 

Name

Drain hose

Clamp metal

Washer for

Plastic band

Insulation for

hanging bracket

fitting

 

 

 

 

 

 

Quantity

1 EA

2 EA

8 EA

 

4 EA

 

1 SET

Shape

for gas pipe

 

 

for liquid pipe

Name

Paper pattern for installation

Installation and Owner's manual

Quantity

1 EA

1 EA

Shape

 

 

<![if ! IE]>

<![endif]>ENGLISH

Installation Manual 3

Important Safety Instructions

Important Safety Instructions

READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.

Always comply with the following precautions to avoid dangerous situations and ensure peak performance of your product

! WARNING

It can result in serious injury or death when the directions are ignored.

! CAUTION

It can result in minor injury or product damage when the directions are ignored.

!WARNING

Installation or repairs made by unqualified persons can result in hazards to you and others.

Installation MUST conform with local building codes or, in the absence of local codes, with the Nation Electrical Code NFPA 70/ANSI C1-1003 or current edition and Canadian Electrical Code Part1 CSA C.22.1.

The information contained in the manual is intended for use by a qualified service technician familiar with safety procedures and equipped with the proper tools and test instruments.

Failure to carefully read and follow all instructions in this manual can result in equipment malfunction, property damage, personal injury and/or death.

Installation

Always perform grounding.

-Otherwise, it may cause electrical shock.

Don’t use a power cord, a plug or a loose socket which is damaged.

-Otherwise, it may cause a fire or electrical shock.

For installation of the product, always contact the service center or a professional installation agency.

-Otherwise, it may cause a fire, electrical shock, explosion or injury.

Securely attach the electrical part cover to the indoor unit and the service panel to the outdoor unit.

-If the electrical part cover of the indoor unit and the service panel of the outdoor unit are not attached securely, it could result in a fire or electric shock due to dust, water, etc.

Always install an air leakage breaker and a dedicated switching board.

-No installation may cause a fire and electrical shock.

Do not keep or use flammable gases or combustibles near the air conditioner.

-Otherwise, it may cause a fire or the failure of product.

Ensure that an installation frame of the outdoor unit is not damaged due to use for a long time.

-It may cause injury or an accident.

Do not disassemble or repair the product randomly.

4 Indoor Unit

Important Safety Instructions

 

- It will cause a fire or electrical shock.

<![if ! IE]>

<![endif]>ENGLISH

 

• Do not install the product at a place that there is concern of falling down.

 

- Otherwise, it may result in personal injury.

 

• Use caution when unpacking and installing.

 

- Sharp edges may cause injury.

 

• Do not turn on the breaker or power under condition that front panel, cabinet, top cover,

 

control box cover are removed or opened.

 

- Otherwise, it may cause fire, electric shock, explosion or death.

 

Operation

Do not share the outlet with other appliances.

-It will cause an electric shock or a fire due to heat generation.

Do not use the damaged power cord.

-Otherwise, it may cause a fire or electrical shock.

Do not modify or extend the power cord randomly.

-Otherwise, it may cause a fire or electrical shock.

Take care so that the power cord may not be pulled during operation.

-Otherwise, it may cause a fire or electrical shock.

Unplug the unit if strange sounds, smell, or smoke comes from it.

-Otherwise, it may cause electrical shock or a fire.

Keep the flames away.

-Otherwise, it may cause a fire.

Take the power plug out if necessary, holding the head of the plug and do not touch it with wet hands.

-Otherwise, it may cause a fire or electrical shock.

Do not use the power cord near the heating tools.

-Otherwise, it may cause a fire and electrical shock.

Do not open the suction inlet of the indoor/outdoor unit during operation.

-Otherwise, it may electrical shock and failure.

Do not allow water to run into electrical parts.

-Otherwise, it may cause the failure of machine or electrical shock.

Hold the plug by the head when taking it out.

-It may cause electric shock and damage.

Never touch the metal parts of the unit when removing the filter.

-They are sharp and may cause injury.

Do not step on the indoor/outdoor unit and do not put anything on it.

-It may cause an injury through dropping of the unit or falling down.

Do not place a heavy object on the power cord.

-Otherwise, it may cause a fire or electrical shock.

When the product is submerged into water, always contact the service center.

-Otherwise, it may cause a fire or electrical shock.

Take care so that children may not step on the outdoor unit.

-Otherwise, children may be seriously injured due to falling down.

Installation Manual 5

Important Safety Instructions

! CAUTION

Installation

Install the drain hose to ensure that drain can be securely done.

-Otherwise, it may cause water leakage.

Install the product so that the noise or hot wind from the outdoor unit may not cause any damage to the neighbors.

-Otherwise, it may cause dispute with the neighbors.

Always inspect gas leakage after the installation and repair of product.

-Otherwise, it may cause the failure of product.

Keep level parallel in installing the product.

-Otherwise, it may cause vibration or water leakage.

Operation

Avoid excessive cooling and perform ventilation sometimes.

-Otherwise, it may do harm to your health.

Use a soft cloth to clean. Do not use wax, thinner, or a strong detergent.

-The appearance of the air conditioner may deteriorate, change color, or develop surface flaws.

Do not use an appliance for special purposes such as preserving animals vegetables, precision machine, or art articles.

-Otherwise, it may damage your properties.

Do not place obstacles around the flow inlet or outlet.

-Otherwise, it may cause the failure of appliance or an accident.

Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules

6 Indoor Unit

Installation

Installation

Read completely, then follow step by step.

Selection of the Best Location

There should not be any heat source or steam near the unit.

There should not be any obstacles to the air circulation.

A place where air circulation in the room will be good.

A place where drainage can be easily obtained.

A place where noise prevention is taken into consideration.

Do not install the unit near the door way.

Ensure the spaces indicated by arrows from the wall, ceiling, or other obstacles.

The indoor unit must have the maintenance space.

Ceiling

 

 

<![if ! IE]>

<![endif]>more

Ceiling board

 

 

 

<![if ! IE]>

<![endif]>or

Ceiling board

 

 

 

 

 

 

<![if ! IE]>

<![endif]>200

 

 

 

 

 

 

<![if ! IE]>

<![endif]>less

500 or

<![if ! IE]>

<![endif]>or more

<![if ! IE]>

<![endif]>Above2 500 3003 or less

 

500 or

<![if ! IE]>

<![endif]>300 or

more

 

more

<![if ! IE]>

<![endif]>1000

 

 

 

 

 

 

 

Unit:mm

 

 

Floor

 

 

 

! CAUTION

In case that the unit is installed near the sea, the installation parts may be corroded by salt. The installation parts (and the unit) should be taken appropriate anti-corrosion measures.

NOTE:

• Avoid the following installation location.

1.Such places as restaurants and kitchen where considerable amount of oil steam and flour is generated. These may cause heat exchange efficiency reduction, or water drops, drain pump mal-function. In these cases, take the following actions;

Make sure that ventilation fan is enough to cover all noxious gases from this place.

Ensure enough distance from the cooking room to install the air conditioner in such a place where it may not suck oily steam.

2.Avoid installng air conditioner in such places where cooking oil or

 

iron powder is generated.

 

Air conditioner

3.

Avoid places where inflammable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

gas is generated.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.

Avoid place where noxious gas is

 

 

 

 

Take enough

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

distance

 

 

 

Use the ventilation fan

 

generated.

 

 

 

 

 

 

 

 

 

 

 

for smoke-collecting

5.

Avoid places near high frequency

 

 

 

 

 

 

 

 

 

 

 

hood with sufficient

 

 

 

 

 

 

 

 

Cooking table

 

generators.

 

 

 

 

 

 

 

 

 

 

 

capacity.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 