LG AM24BP INSTALLATION MANUAL

21
ENGLISH
ances or devices, it must be a dedicated power source for this appliance.
• Do not modify or extend the power cable.
• Ensure the power cable is secure so that it does not come out while the appliance is operating.
• Cut the power during a severe thunderstorm or lightening or when not in use for a long period of time.
• Do not grab the power cable when removing the plug, but rather hold the power plug tightly.
• Do not bend the power cable excessively or place a heavy ob­ject on it.
• Do not turn on the circuit breaker or power when covers are removed or opened.
• Make sure that the pipe and the power cable connecting the indoor and outdoor units are not pulled too tight when in­stalling the appliance.
Install dedicated electric outlet and circuit breaker for the appli­ance.
• Make sure to close the cover of the control box after connect­ing the wiring to the appliance.
• Loose connections may cause electrical sparks, injury, and death.
• Do not install the appliance in a place where flammable liquids or gases such as gasoline, propane, paint thinner, etc., are stored.
• Only use the refrigerant designated on the label, do not put any foreign substances into the appliance.
• Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an
This symbol indicates that this appliance uses a flam­mable refrigerant. If the refrigerant is leaked and expo­sure to an external ignition source, there is a risk of fire.
This symbol indicates that the Operation Manual
should be read carefully. This symbol indicates that a service personnel should be handling this equipment with reference to the Instal­lation Manual. This symbol indicates that information is available such as the Operating Manual or Installation Manual.
IMPORTANT SAFETY INSTRUCTIONS
WARNING
To reduce the risk of explosion, fire, death, electric shock, injury or scalding to persons when using this product, follow basic pre­cautions, including the following:
• The information contained in the manual is intended for use by a qualified service technician who is familiar with the safety procedures and equipped with the proper tools and test instru­ments.
• The appliance shall be installed in accordance with national wiring regulations.
• Compliance with national gas regulations shall be observed.
• Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.
• If the supply cord is damaged, it must be replaced by the man­ufacturer or its service agents or similarly qualified person in order to avoid a hazard.
• Appliance shall be disconnected from its power source during
!
service and when replacing parts.
• Failure to read and follow all instructions in this manual can re­sult in equipment malfunction, property damage, personal in­jury and/or death.
• Check that the appliance’s voltage level is 90 % or higher than the rated voltage. To check it, refer to the label attached to the side of the appliance.
• Do not install the appliance on an unstable surface or in a place where there is danger of it falling.
• This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.
• Improper connection of the equipment-grounding conductor can result in risk of electric shock. Check with a qualified elec­trician or service personnel if you are in doubt as to whether the appliance is properly grounded.
• If the power supply cable is damaged or the cable connection is loose, do not use the power supply cable and contact an au­thorized service center.
• Do not connect the ground wire to a gas pipe, a lightning rod, or a telephone ground wire.
• Do not share the power supply for this unit with other appli-
The following symbols are displayed on indoor and outdoor units. (for R32)
INSTALLATION MANUAL AIR CONDITIONER
TYPE : WALL MOUNTED Original instruction
MFL67713839
Rev.04_032321
Copyright © 2016 - 2021 LG Electronics Inc. All Rights Reserved.
SAFETY INSTRUCTIONS
The following safety guidelines are intended to prevent unforeseen risks or damage from unsafe or incorrect operation of the appliance. The guidelines are separated into ‘WARNING’ and ‘CAUTION’ as described below.
WARNING
This indicates that the failure to follow the instructions can cause serious injury or death.
CAUTION
This indicates that the failure to follow the instructions can cause the minor injury or damage to the product.
!
!
This symbol is displayed to indicate matters and operations that can cause risk. Read the part with this symbol carefully and follow the instructions in order to avoid risk.
!
3 4
industry-accredited assessment authority regard of flammable refrigerants, which authorizes their competence to handle re­frigerants safely in accordance with an industry recognized as­sessment specification.
• Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flamma­ble refrigerants.
• Keep any required ventilation openings clear of obstruction.
• Refrigerant tubing shall be protected or enclosed to avoid damage.
• Flexible refrigerant connectors (such as connecting lines be­tween the indoor and outdoor unit) that may be displaced dur­ing normal operations shall be protected against mechanical damage.
• Mechanical connections shall be accessible for maintenance purposes.
• A brazed, welded, or mechanical connection shall be made be­fore opening the valves to permit refrigerant to flow between the refrigerating system parts.
• Use non-flammable gas (nitrogen) to check for leak and to purge air.
• Use only refrigerant grade pipe specific for R32 refrigerant. Do Not Use R22 products, which have lower pressure ratings and can result in excessive pressure, explosion and injury.
• Inert gas (oxygen free nitrogen) should be used when you checking for leaks, cleaning or repairs of pipes etc. If you are using combustible gases including oxygen, appliance may have the risk of fires and explosions.
• Do not discharge the refrigerant into the atmosphere.
• If refrigerant leaks, ventilate the room.
• Always check for gas (refrigerant) leakage after installation or repair of appliance.
• Be cautious not to get injured by the sharp edges while in­stalling the appliance or taking it out of its packaging.
• Ensure that you carry by the chassis when you lift the unit.
• This appliance should only be transported by two or more peo­ple holding the appliance securely.
• Safely dispose of packing materials such as screws, nails or batteries using proper packaging after installation or repair.
• To avoid nitrogen entering the refrigerant system in a liquid state, the top of the cylinder must be higher than its bottom when you pressurize the system.
• The tubing shall be protected to the extent that it will not be handled or used for carrying during moving of the appliance.
• Ventilation system have to be installed in the space when ap­pliance with R32 is using for cooling of electric equipment.
• Do not use the appliance for special purposes, such as pre­serving foods, works of art, and etc. It is an appliance for con­sumer purposes, not a precision refrigerant system. There is risk of damage or loss of property.
• Do not install the unit in potentially explosive atmospheres.
Refrigerant (for R32 Only)
WARNING
• The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
!
• The appliance shall be stored in a room without continuously operating open flames (for example an operating gas appli­ance) and ignition sources (for example an operating electric heater).
• The appliance shall be stored so as to prevent mechanical damage from occurring.
• Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
• Do not pierce or burn.
• Be aware that refrigerants may not contain an odour.
• Pipe-work shall be protected from physical damage and shall not be installed in an unventilated space, if that space is smaller than the minimum floor area.
Minimum Floor Area
• m: Total refrigerant amount in the system
• Total refrigerant amount: Factory refrigerant charge + Additional refrigerant amount
• Do not use copper pipes which are deformed. Otherwise, the expansion valve or capillary tube may become blocked with contaminants.
• Ducts connected to an appliance shall not contain an ignition source.
• The installation of pipe-work shall be kept to a minimum.
When installing or relocating the appliance, consult with a quali­fied technician to set up the appliance. The appliance should not be installed by someone without proper qualifications.
• Operating the appliance while it is disconnected to the pipe could result in explosion and damage. Use the appliance after connecting it to the pipe once the appliance has been relo­cated and the refrigerant circuit repaired.
• Do not place a heater or other heating appliances near the power cable.
CAUTION
To reduce the risk of minor injury to persons, malfunction, or damage to the product or property when using this product, fol­low basic precautions, including the following:
• Install at places where it can endure the weight and vibration/noise of the outdoor unit.
• Install the appliance in a place where the noise from the out­door unit or the exhaust air will not inconvenience the neigh­bors. Failure to do so may result in conflict with the neighbors.
• Ensure the appliance is installed level. Otherwise, it may cause vibration or water leakage.
• Install the drain hose properly for the smooth drainage of water condensation.
• Do not touch the leaking refrigerant during installation or re­pair.
!
m (kg)
Minimum Floor Area (m
2
)
Floor Standing Wall Mounted Ceiling Mounted
< 1.224 - - -
1.224 12.90 1.43 0.956
1.2 12.36 1.37 0.92
1.4 16.82 1.87 1.25
1.6 21.97 2.44 1.63
1.8 27.80 3.09 2.07
2.0 34.32 3.81 2.55
2.2 41.53 4.61 3.09
2.4 49.42 5.49 3.68
Features
INTRODUCTION
Air Intake Vents
Connecting Wires
Piping
Air Outlet Vents
Base Plate
Drain Hose
Front grille
Air filter
On/Off button
Signal receiver Display
Plasmaster Ionizer
Air deflector
(Vertical louver & Horizontal vane)
Air outlet
* The feature can be changed according to type of model.
NOTE
• When mechanical connectors are reused indoors, sealing parts shall be renewed.
INSTALLATION MAP
Connecting cable (Optional Parts)
Vinyl tape (Wide)
• Apply after carrying out a drainage test.
• To carry out the drainage test, remove the air filters and pour water into the heat exchanger.
Saddle
Gas side piping (Optional Parts) Liquid side piping (Optional Parts) Additional drain pipe
Vinyl tape (Narrow) Drain hose
Installation plate Sleeve Bushing-Sleeve
Putty(Gum Type Sealant)
Bend the pipe as closely on the wall as possible, but be careful that it doesn't break.
• You should purchase the installation parts. (lt can be changed according to market)
• Pipes and wires should be purchased separately for installation of the product.
* The feature can be changed according a type of model. * Work to the vinyl tape should up from below.
NOTE
INSTALLATION TOOLS
INSTALLATION PARTS
Screws for fixing panels are attached to decoration panel. When Indoor unit (5.0/6.6 kW) is connected to the Multi Outdoor unit, use the connector.
Figure FigureName
Screw driver
Electric drill
Measuring tape, Knife
Hole core drill
Spanner
Torque wrench
Multi-meter
Hexagonal wrench
Ammeter
Gas-leak detector
Thermometer,
Level
Flaring tool set
Name
Select the best Location
- There should not be any heat or steam near the unit.
- Select a place where there are no obstacles around of the unit.
- Make sure that condensation drainage can be conveniently routed away.
- Do not install near a doorway.
- Ensure that the interval between a wall and the left (or right) of the unit is more than 100mm. The unit should be installed as high as possible on the wall, allowing a minimum of 200 mm from ceiling.
- Use a metal detector to locate studs to pre­vent unnecessary damage to the wall.
* UV-C Model Only
* The feature can be changed according to
type of model.
Outdoor unit
- If an awning is built over the unit to prevent direct sunlight or rain exposure, make sure that heat radiation from the condenser is not restricted.
- Ensure that the space around the back and sides is more than 300 mm. The space in front of the unit should be more than 700 mm of space.
- Do not place animals and plants in the path of the warm air.
- Take the weight of the air conditioner into account and select a place where noise and vibration are minimum.
- Select a place where the warm air and noise from the air conditioner do not disturb neighbors.
A
C
B B
INSTALLATION
The gap between the indoor unit and ceil­ing is needed more than 200 mm for dis­assemble the air filter.
NOTE
- Do not use nails and/or screws to attach indoor units to sheetrock, drywall, plasterboard, tile, plywood, or similar material types without proper anchors. Indoor units must be securely, and properly mounted and anchored or damage and/or injury may result from improper installation.
Anchor
Anchor Screw
mm mm
6 x 30 4 x 50
Type A B C*
Wall mounted 200 100 1 800
(Unit : mm)
- The feature can be changed according to type of model.
65
Name
Installation plate
Type "A" screw
Type "B" screw
Type "C" screw
Remote control
holder
Cloth tape
Connector
Quantity Shape
1 EA
The feature can be changed according to type of model.
5 EA
2 EA
2 EA
Type “B” screw
1 EA
1 EA
1 EA (5.0 kW) 2 EA (6.6 kW)
5.0 kW : ڸØ9.52 (3/8) ơ Ø12.7 (1/2)
6.6 kW : ڸØ9.52 (3/8) ơ Ø12.7 (1/2) ڹØ15.88 (5/8) ơ Ø12.7 (1/2)
300
Sunroof
More than
700
More than
600
More than
300
(Unit : mm)
More than
Fence or
obstacles