LG AB-H366KSA0 Service Manual

Concealed Duct Air Conditioner
SVC MANUAL(Exploded View)
MODEL : AB-H366KSA0
CAUTION
Before Servicing the unit, read the safety precautions in this manual. Only for authorized service personnel.
http://biz.lgservice.com
2 Concealed Duct Air Conditioner
1. Specification
Indoor
Power Supply Ø / V / Hz
Cooling Capacity kW
Btu/h
Heating Capacity kW
Btu/h
Current Nominal Running Current A
Fan Motor Type
Fan Type
Motor Output(W) x No. of Unit
Air Flow Rate CMM
(H / M / L) cfm
External Static Pressure mmAq
Capacitor µF / Vac
Drive
Coil Row x Column x FPI
Dimensions Body mm(inch)
(W x H x D) Decorative Panel mm(inch)
Net Weight Body kg (lbs)
Decorative Panel kg (lbs)
Air Filter
Sound Level (H / M / L) dB(A)+3
Piping Liquid mm (inch)
Connections Gas mm (inch)
Drain(OD/ID) mm
Dehumidification Rate l/h
Safety Devices
Temperature Sensor
Referigerant
Referigerant Control
Connectable Outdoor Unit
Power and Transmission Interunit Cable No.x mm
2
Indoor Unit Type
Model
Cealing Concealed Duct
ABNH366KSA0
1/220~240/50
10.00
34,120
10.25
34,973
18
Induction
Blower
315 x 1
36/33/27
1,377/1,165/953
12.5
4/450
Direct Drive
3R x 13 C x 13
1040 x 350 x 560(40.9 x 13.8 x 22.0)
-
39(85.9)
-
-
50/47/43
9.52(3/8)
15.88(5/8)
25.4/22.6
2.89
Fuse, Thermal Protect
Thermistor
R410A
Orifice
Single
5 x 1.0
Note:
1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27°C(80.6°F) DB/19°C(66.2°F) WB
- Outdoor Temperature 35°C(95°F) DB/24°C(75.2°F) WB
Heating: - Indoor Temperature 20°C(68°F) DB/15°C(59°F) WB
- Outdoor Temperature 7°C(44.6°F) DB/6°C(42.8°F) WB
Piping Length - Interconnecting Piping Length 7.5m
- Level Difference of Zero
2. Wiring cable size must comply with the applicable local and national code.
3. The specification may be subject to change without notic for purpose of improvement.
Service Manual 3
Outdoor
Nominal Capacity Cooling kW
Btu/h
Heating kW
Btu/h
Nominal Input Cooling kW
Heating kW Testing Combination Running Current(Rating) Cooling A
Heating A Starting Current Cooling/Heating A Power Supply Ø / V / Hz Power Supply Cable(Outdoor) No. x mm
2
Power and Transmission Cable
No. x mm
2
(Outdoor to Indoor or Outdoor to BD) Power and Transmission Cable(BD to Indoor) No. x mm
2
Dimensions W x H x D mm(inch) Net Weight kg(lbs) Max. Number of Connectable Indoor Units Compressor (#1) Type
Qty x Model
Motor type
Oil charge volume cc
Oil Type Compressor (#2) Type
Qty x Model
Motor type
Oil charge volume cc
Oil type Compressor (#3) Type
Qty x Model
Motor type
Oil charge volume cc
Oil type Refrigerant Cycle A Charge (at 7.5m) g(oz)
Cycle B Charge (at 7.5m) g(oz)
Type
Control Heat Exchanger (Rows x Column x FPI) x No.
Defrosting Method Fan Capacitor µF/Vac
Drive
Discharge Direction(Side/Top)
Air Flow Rate x No. of Fan CMM(cfm) Sound Level(H/L) Sound Pressure dB(A)+3 Piping Connections Liquid(Cycle A) mm(inch)
Gas(Cycle A) mm(inch)
Liquid(Cycle B) mm(inch)
Gas(Cycle B) mm(inch)
High Pressure Gas mm(inch) Max. Interunit Total Piping m Piping Length Main Piping m
Total Branch Piping m
Each Branch Piping m Max. Elevation Outdoor Unit~Indoor Unit m Difference Indoor Unit~Indoor Unit m
Outdoor Unit
ABUH366KSA0
10.00
34,120
10.25
34,973
3.9
3.4
­18 15
40/-
1/220_240/50
3 x 5.5
5x1.0 (Including Earth)
-
870 x 1060 x 320(34.3 x 41.7 x 22.0)
80(176)
1
Rotary
1 x NN40VAAMT
Permenant Split Capacitor
1,300
MEL 56
-
-
-
-
-
-
-
-
-
-
3,250(145)
-
R410A
Capillary
(2R x 52C x 18) x 1
Reversing Cycle
-
Direct Drive
Side
53(1,872) x 2
58
9.52(3/8)
15.88(5/8)
-
-
­30
7.5
-
­15
-
Note:
1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27°C(80.6°F) DB/19°C(66.2°F) WB
- Outdoor Temperature 35°C(95°F) DB/24°C(75.2°F) WB
Heating: - Indoor Temperature 20°C(68°F) DB/15°C(59°F) WB
- Outdoor Temperature 7°C(44.6°F) DB/6°C(42.8°F) WB
Piping Length - Interconnecting Piping Length 7.5m
- Level Difference of Zero
2. Wiring cable size must comply with the applicable local and national code.
3. The specification may be subject to change without notic for purpose of improvement.
2. Function Table
4 Concealed Duct Air Conditioner
Note :
O : Applied X : Not applied - : No relation Option : Model name & price are different according to options, and assembled in factory with main unit. Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package
: These safty switcher are standard or optional features defending on region & country
Air supply outlet Airflow direction control(left & right) Airflow direction control(up & down) Auto swing(left & right) Auto swing(up & down) Airflow steps(fan/cool/heat) Chaos swing Chaos wind(auto wind) Jet cool(Power wind) Swirl wind Deodorizing filter Plasma air purifier Prefilter(washable / anti-fungus) Drain pump E.S.P. control Electric heater(operation) High ceiling operation Hot start Self diagnosis Soft dry operation Auto changeover Auto cleaning Auto operation(artificial intelligence) Auto restart operation Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly) Two thermistor control Standard wired remote controller Deluxe wired remote controller Simple wired remote controller Wired remote controller(for hotel use) Wireless remote controller(simple) Wireless LCD remote control General central controller (Non LGAP) Dry contact Network Soluation(LGAP) PDI(power distribution indicator) PI 485 Zone control CTIE Electro thermostat Thermistor Fan Auto Operation Fan Auto Fuction Dry contact Auto/Manual Dry Contact Error State Display RF Controller
FunctionCategory
ABNH366KSA0
1 X X X X
3/3/3
X X X X X X X
Accessory
X X
X O O O O
X
X O O
X O
X O O O
6711A20127B
PQRCUDS0 PQRCUCA0
PQRFCS0
X
6711A20096H
X
PDS-DB0
O
PQNUD1S00 PMNFP14A0
ABZCA
X
X
AQTTA
O O
RF Controller
X
PQRFA0
Air flow
Air Purifier
Installation
Reliability
Convenience
Individual
Control
CAC Network Function
Special
Function
Kit
Others
Indoor