LG A30033W5 Diagram

LG A30033W5 Diagram

Pipe length and the elevation

Capacity

Pipe Size

Standard

Max.

Max.

Additional

 

 

Length

Elevation

Length

Refrigerant

(Btu/h)

 

 

GAS

LIQUID

(m)

B (m)

A (m)

(g/m)

 

 

 

 

 

 

 

 

18K(60Hz)

5/8"

1/4"

5

10

20

20

 

 

 

 

 

 

 

18K(50Hz)

1/2"

1/4"

5

15

30

30

 

 

 

 

 

 

 

24K(50Hz)

5/8"

3/8"

5

15

30

30

 

 

 

 

 

 

 

26K(50Hz)

5/8"

3/8"

5

15

30

30

 

 

 

 

 

 

 

Outdoor unit

A

Indoor unit

B

Outdoor unit

Oil trap

A

 

Indoor unit

B

In case more than 5m

CAUTION

*Capicity is based on standard length and maximum allowance length is the basis of reliability.

*Oil trap should be installed per 5~7 meters.

* Numerical value in "( )" is for Rotary Comp. model.

- 11 -