LG A18LHU User Manual

<![if ! IE]>

<![endif]>TILI OʻZBEK ЯЗЫК РУССКИЙ ENGLISH

OWNER’S MANUAL

AIR

CONDITIONER

Please read this manual carefully before operating your set and retain it for future reference.

TYPE : WALL MOUNTED

P/NO : MFL63265422

www.lg.com

Room Air Conditioner Owner’s Manual

TABLE OF CONTENTS

Safety Precautions.........................

3

Prior to Operation ..........................

9

Introduction ..................................

10

Electrical Safety ...........................

11

Operating Instructions.................

13

Maintenance and Service ............

27

FOR YOUR RECORDS

Write the model and serial numbers here:

Model #

Serial #

You can find them on a label on the side of each unit.

Dealer's Name

Date Purchased

νStaple your receipt to this page in the event you need it to prove date of purchase or for warranty issues.

READ THIS MANUAL

Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner.

You'll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of

Troubleshooting Tips first, you may not need to call for service at all.

PRECAUTION

Contact the authorized service technician for repair or maintenance of this unit.

Contact the installer for installation of this unit.

The air conditioner is not intended for use by young children or invalids without supervision.

Young children should be supervised to ensure that they do not play with the air conditioner.

When the power cord is to be replaced, replacement work shall be performed by authorized personnel only using only genuine replacement parts.

Installation work must be performed in accordance with the National Electric Code by qualified and authorized personnel only.

2 Room Air Conditioner

Safety Precautions

Safety Precautions

To prevent the injury of the user or other people and property damage, the following instructions must be followed.

νIncorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications.

This symbol indicates the possibility of death or serious injury.

This symbol indicates the possibility of injury or damage to properties only.

ν The meanings of the symbols used in this manual are as shown below.

Be sure not to do.

Be sure to follow the instruction.

ν Installation

Do not use damaged power cords, plugs, or a loose socket.

There is risk of fire or electric shock.

For electrical work, contact

Always use the power plug

the dealer, seller, a qualified

and socket with the ground

electrician, or an Authorized

terminal.

Service Center.

• There is risk of fire or electric

• There is risk of electric shock.

shock.

 

Install the panel and the

Do not modify or extend the

Do not install, remove, or

cover of control box

power cord.

re-install the unit by

securely.

 

yourself (customer).

• There is risk of fire or electric

• There is risk of fire or electric

• There is risk of fire, electric

shock.

shock.

shock, explosion, or injury.

<![if ! IE]>

<![endif]>ENGLISH

Owner's Manual 3

Safety Precautions

Be cautious when

For installation, always

unpacking and installing

contact the dealer or an

the product.

Authorized Service Center.

• Sharp edges could cause injury.

• There is risk of fire, electric

Be especially careful of the

shock, explosion, or injury.

case edges and the fins on the

 

condenser and evaporator.

 

Be sure the installation area

Do not let the air conditioner

does not deteriorate with

run for a long time when the

age.

humidity is very high and a

 

door or a window is left open.

Do not install the product on a defective installation stand.

It may cause injury, accident, or damage to the product.

Do not install the air conditioner on a gypsum board.

If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury.

Moisture may condense and wet or damage furnishings.

The air conditioner unit is likely to fall down and become damaged.

ν Operation

Take care to ensure that power cords could not be pulled out or damaged during operation.

There is risk of fire or electrical shock.

Do not place anything on the power cord.

There is risk of fire or electric shock.

Do not turn the airconditioner ON or OFF by plugging or unplugging the power plug.

There is risk of fire or electrical shock.

4 Room Air Conditioner

Safety Precautions

Use a dedicated outlet for

Grasp the plug to remove

this appliance.

the cord from the outlet. Do

 

not touch it with wet hands.

• There is risk of fire or electrical

• There is risk of fire or electrical

shock.

shock.

Do not allow water to run into electric parts.

It may cause There is risk of fire, failure of the product, or electric shock.

When flammable gas leaks, turn off the gas and open a window for ventilation before turn the product on. DO NOT use the telephone or turn switches on or off.

Do not store or use flammable gas or combustibles near the air conditioner.

There is risk of fire or failure of product.

Unplug the unit if strange sounds, odors, or smoke comes from it.

• There is risk of explosion or fire. • There is risk of electrical shock or fire

Do not place a heater or other appliances near the power cable.

There is risk of fire and electric shock.

Do not use the product in a tightly closed space for a long time.

• Oxygen deficiency could occur.

Stop operation and close the window in storm or hurricane. If possible, remove the air conditioner from the window before the hurricane arrives.

There is risk of property damage, failure of product, or electric shock.

<![if ! IE]>

<![endif]>ENGLISH

Owner's Manual 5

Safety Precautions

Do not open the inlet grill of the product during operation. (Do not touch the electrostatic filter, if the unit is so equipped.)

There is risk of physical injury, electric shock, or product failure.

Unplug the appliance before performing cleaning or maintenance.

When the product is soaked

Ventilate the product from

(flooded or submerged),

time to time when operating

contact an Authorized

it together with a stove, etc.

Service Center.

 

• There is risk of fire or eletric

• There is risk of fire or electrical

shock.

shock.

When the product is not be

Take care to ensure that

used for a long time,

nobody could step on or fall

disconnect the power supply

onto the outdoor unit.

plug or turn off the breaker.

 

• There is risk of electrical shock. • There is risk of product damage or failure, or unintended operation.

This could result in personal injury and product damage.

For inner cleaning, contact an Authorized Service Center or a dealer.

Do not use harsh detergent that causes corrosion or damage on the unit.

• Harsh detergent may also cause failure of product, fire, or electronic shock.

ν Installation

Always check for gas (refrigerant) leakage after installation or repair of product.

Low refrigerant levels may cause failure of product.

 

 

 

 

 

 

Install the drain hose to

Keep level even when

ensure that water is drained

installing the product.

away properly.

 

• A bad connection may cause

• To avoid vibration or water

water leakage.

leakage.

6 Room Air Conditioner

Safety Precautions

Do not install the product

Use two or more people to

where the noise or hot air

lift and transport the air

from the outdoor unit could

conditioner.

damage the neighborhoods.

• It may cause a problem for your • Avoid personal injury. neighbors.

Do not install the product where it will be exposed to sea wind (salt spray) directly.

It may cause corrosion on the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient operation.

ν Operation

Do not direct airflow at room occupants. (Don't sit in the draft.)

Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigeration system.

• This could damage your health. • There is risk of damage or loss of property.

Use a soft cloth to clean. Do

Do not touch the metal

not use harsh detergents,

parts of the product when

solvents, etc.

removing the air filter. They

 

are very sharp!

• There is risk of fire, electric

• There is risk of personal injury.

shock, or damage to the plastic

 

parts of the product.

 

Do not block the inlet or outlet of air flow.

• It may cause product failure.

Do not step on or put anyting on the product. (outdoor units)

There is risk of personal injury and failure of product.

<![if ! IE]>

<![endif]>ENGLISH

Owner's Manual 7

Safety Precautions

Always insert the filter securely. Clean the filter every two weeks or more often if necessary.

A dirty filter reduces the efficiency of the air conditioner and could cause product malfunction or damage.

Do not insert hands or other

Do not drink the water

objects through the air inlet

drained from the unit.

or outlet while the air

 

conditioner is plugged in.

 

• There are sharp and moving

• It is not sanitary and could

parts that could cause personal

cause serious health issues.

injury.

 

Use a firm stool or ladder when cleaning or maintaining the air conditioner.

• Be careful and avoid personal injury.

Replace the all batteries in the remote control with new ones of the same type. Do not mix old and new batteries or different types of batteries.

• There is risk of fire or explosion

ν Disuse

Do not recharge or disassemble the batteries. Do not dispose of batteries in a fire.

• They may burn or explode.

If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not use the remote if the batteries have leaked.

If you eat the liquid from the batteries, brush your teeth and see doctor. Do not use the remote if the batteries have leaked.

• The chemicals in batteries could

• The chemicals in batteries could

cause burns or other health

cause burns or other health

hazards.

hazards.

Operation ranges

For Heat & Cool model, heating operation range follows the below table.

Heating

Outdoor temperature

 

operation range

0 ~ 24 °C

 

 

 

*When the outdoor temperature drops below 0 °C, heating capacity may drop slightly depending on the operation condition.

8 Room Air Conditioner

Prior to Operation

Prior to Operation

Preparing for Operation

1.Contact an installation specialist for installation.

2.Plug in the power plug properly.

3.Use a dedicated circuit.

4.Do not use an extension cord.

5.Do not start/stop operation by plugging/unplugging the power cord.

6.If the cord/plug is damaged, replace it with only an authorized replacement part.

Usage

1.Being exposed to direct airflow for a long time may be hazardous to your health. Do not expose occupants, pets, or plants to direct airflow for a long time.

2.Due to the possibility of oxygen deficiency, ventilate the room when using the appliance together with stoves or other heating devices.

3.Do not use this air conditioner for non-specified special purpose (e.g. preserving precision devices, food, pets, plants, or art objects). Such use may damage your properties.

Cleaning and Maintenance

1.Do not touch the metal parts of the unit when removing the filter. Injury can occur.

2.Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to electric shock.

3.When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates at a very high speed during operation. There is a possibility of injury if the unit’s power is triggered while cleaning inner parts of the unit.

Service

For repair and maintenance, contact your authorized service dealer.

<![if ! IE]>

<![endif]>ENGLISH

Owner's Manual 9

Introduction

Introduction

Symbols used in this Manual

This symbol alerts you to the risk of electric shock.

This symbol alerts you to hazards that may cause harm to the air conditioner.

NOTICE This symbol indicates special notes.

Features

WARNING: This appliance should be installed in accordance with national wiring regulations. This guide acts as a guide to help to explain product features.

Indoor

Frame

Front Panel

Power cord

Signal Receptor

Outdoor

Air Intake Vents

Air Outlet Vents

Base Plate

Air Discharge

NEO Plasma Filter

Upper Front Grille

Supporter

Lower Front Grille

Air Filter

Connecting

Wires

Piping

Drain Hose

10 Room Air Conditioner

Electrical Safety

Electrical Safety

WARNING: This appliance must be properly grounded.

To minimize the risk of electric shock, you must alway plug into a grounded oulet.

Preferred method

Ensure proper ground exists before use

<![if ! IE]>

<![endif]>ENGLISH

WARNING: Do not cut or remove the grounding prong from the power plug.

WARNING: Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated, and the wall receptacle is grounded through the house wiring.

WARNING: If you have any doubt whether the air conditioner is properly grounded, have the wall receptacle and circuit checked by a qualified electrician.

Owner's Manual 11

Electrical Safety

Temporary Use of an Adapter

We strongly discourage the use of an adapter due to potential safety hazards. For temporary connections, use only a UL-listed adapter, available from most local hardware stores. Ensure that the large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection. To disconnect the power cord from the adapter, use one hand on each to avoid damaging the ground terminal. Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage.

Temporary method

Adapter Plug

Metal Screw

Receptacle Cover

WARNING: Never use the appliance with a broken adapter.

Temporary Use of an Extension Cord

We strongly discourage the use of an extension cord due to potential safety hazards. For temporary situations, use only CSA certified and UL listed 3-wire grounded extension cords, rated 15 A, 125 V.

12 Room Air Conditioner

Operating Instructions

How to insert the Batteries

1.Remove the battery cover by pulling it according to the arrow direction.

2.Insert new batteries making sure that the (+) and (-) of battery are installed correctly.

3.Reattach the cover by sliding it back into position.

NOTICE Use 2 AAA(1.5volt) batteries.

Do not use rechargeable batteries.

Operating Instructions

<![if ! IE]>

<![endif]>ENGLISH

Storage and Tips for using the Remote Controller

The remote controller may be stored by mounting it on a wall.

To operate the room air conditioner, aim the remote controller at the signal receptor.

Signal receptor

Receives the signals from the remote controller.(Signal receiving sound: two short beeps or one long beep.)

Singnal receptor

Owner's Manual 13

Operating Instructions

Remote Control Operations

The controls will look like the following.

Controls

Signal transmitter

5

 

 

1

6

 

 

 

 

 

 

3

4

 

 

 

2

 

 

10

 

CANCEL

 

 

 

9

7

OFF

SET

ON

12

11

 

AUTO CLEAN

8

 

 

17

13

 

 

14

15

 

 

16

Flip-up door (opened)

Operation Mode

Cooling Operation

Auto Operation or Auto Changeover

Healthy Dehumidification Operation

Heating Operation

• Cooling Model(), Heat Pump Model()

1.START/STOP BUTTON

Operation starts when this button is pressed and stops when the button is pressed again.

2.OPERATION MODE SELECTION BUTTON

Used to select the operation mode.

3. ROOM TEMPERATURE SETTING BUTTONS

Used to select the room temperature.

4. INDOOR FAN SPEED SELECTOR

Used to select fan speed in four steps low, medium, high and CHAOS.

5. JET COOL/HEATING(OPTIONAL)

Used to start or stop the speed cooling/heaing.(speed cooling/heating operates super high fan speed in cooling/heatig mode.)

6. CHAOS SWING BUTTON

Used to stop or start louver movement and set the desired up/down airflow direction.

7.ON/OFF TIMER BUTTONS

Used to set the time of starting and stopping operation. (See page 24)

8.TIME SETTING BUTTONS

Used to adjust the time. (See page 24)

9.TIMER SET/CANCEL BUTTON

Used to set the timer when the desired time is obtained and to cancel the Timer operation. (See page 24)

10.SLEEP MODE AUTO BUTTON

Used to set Sleep Mode Auto operation. (See page 24)

11.AIR CIRCULATION BUTTON

Used to circulate the room air without cooling or heating. (See page 25)

12.ROOM TEMPERATURE CHECKING BUTTON

Used to check the room temperature.

13.NEO PLASMA(OPTIONAL)

Used to start or stop the plasmapurification function. (See page 22)

14.HORIZONTAL AIRFLOW DIRECTION CONTROL BUTTON (OPTIONAL)

Used to set the desired vertical airflow direction.

15.RESET BUTTON

Used prior to resetting time.

16.2nd F Button

Used prior to using modes printed in blue at the bottom of buttons. (See page 23)

17.AUTO CLEAN (OPTIONAL)

Used to set Auto Clean mode.

14 Room Air Conditioner

Cooling operation

Operating Instructions

<![if ! IE]>

<![endif]>ENGLISH

1

Press the Start/Stop button.

The unit will respond with

a beep.

2Operation, press the Operation Mode Selection button.Open the door of the remote controller. To select Cooling

Each time the button is pressed, the operation mode is shifted in the direction of the arrow.

Cooling

Auto

Healthy

Heating

 

 

Dehumidification

(Heat pump model only)

3

Close the door of the remote controller. Set the temperature

lower than the room temperature. The temperature can be

 

set within a range of 18°C~30°C at intervals of 1°C.

ON

To raise the temperature

 

 

To lower the temperature

4

Set the fan speed again with the door

of the remote controller still closed.

You can select the fan speed in four steps-low, medium, high and CHAOS. Each time the button is pressed, the fan speed mode is shifted.

Natural wind by the CHAOS logic

οFor fresher feeling, press the Indoor fan speed selector and set to CHAOS mode. In this mode, the wind blows like a natural breeze by automatically changing fan speed according to the CHAOS logic.

Owner's Manual 15

Operating Instructions

Auto operation (Cooling model only)

1Press the Start/Stop button. The unit will respond with

a beep.

2

Open the door of the remote controller. To select Auto

Operation, press the operation mode selection button.

Each time the button is pressed, the operation mode is shifted in the direction of the arrow.

Cooling

Auto

Healthy

Heating

 

 

Dehumidification

(Heat pump model only)

ON

During Auto Operation

3electronic controls based on the actual room temperature. If you want to change the set temperature, press the Room Temperature Setting buttons. The cooler or warmer you feel,

the more times (up to two times) you should press the button. The set temperature will be changed automatically.The temperature and fan speed are automatically set by the

To raise the temperature

To lower the temperature

οYou cannot control the indoor fan speed. It has already been set by the Fuzzy rule.

οIf the system is not operating as desired, manually switch to another mode. The system will not automatically switch from the cooling mode to the heating mode, or from heating mode to cooling mode, it must be done by manually resetting.

οDuring Auto Operation, pressing the chaos swing button makes the horizontal louvers swing up and down automatically. If you want to stop auto-swing, press the chaos swing button again.

16 Room Air Conditioner

Auto changeover operation(Heat pump model only)

1

Press the Start/Stop button.

The unit will respond with

a beep.

Operating Instructions

<![if ! IE]>

<![endif]>ENGLISH

2Open the door of the remote controller. To select Auto Changeover Operation, press the Operation Mode Selection button.

Each time the button is pressed, the operation mode is shifted in the

direction of the arrow.

Cooling

Auto

Healthy

Heating

 

changeover

Dehumidification

(Heat pump model only)

3

Close the door of the remote controller. Set the temperature

lower than the room temperature. The temperature can be

 

set within a range of 18°C~30°C at intervals of 1°C.

 

To raise the temperature

ON

 

 

To lower the temperature

4

Set the fan speed again with the door

of the remote controller still closed.

You can select the fan speed in four steps-low, medium, high and CHAOS. Each time the button is pressed, the fan speed mode is shifted.

During Auto changeover Operation

The air conditioner changes the operation mode automatically to keep indoor temperature. When room temperature vary over ±2°C with respect to setting temperature, air conditioner keeps the room temperature within ±2°C with respect to setting temperature by auto changeover mode.

Owner's Manual 17

Operating Instructions

Healthy dehumidification operation

1

Press the Start/Stop button.

The unit will respond with

a beep.

2Open the door of the remote controller. To select Healthy Dehumidification Operation, press the Operation Mode

Selection button.

Each time the button is pressed, the operation mode is shifted in the direction of the arrow.

Cooling

Auto

Healthy

Heating

 

 

Dehumidification

(Heat pump model only)

ON

3of the remote controller still closed. You can select the fan speed in four steps-low, medium, high, or CHAOS.

Each time the button is pressed, the fan speed mode is shifted.Set the fan speed again with the door

Natural wind by the CHAOS logic

οFor fresher feeling, press the Indoor Fan Speed Selector and set to CHAOS mode. In this mode, the wind blows like a natural breeze by automatically changing fan speed according to the

CHAOS logic.

During Healthy Dehumidification Operation

οIf you select the dehumidification mode on the operation selection button, the A/C starts to run the dehumidification function. It automatically sets the room temp. and airflow volume to the best condition for dehumidification, based on the sensed current room temp.

In this case, however, the setting temp. is not displayed on the remote controller and you are not able to control the room temp. either.

οDuring the healthy dehumidification function, the airflow volume is automatically set according to the optimization algorithm responding to the current room temp. status, so that the room condition is kept healthy and comfortable even in the very humid season.

18 Room Air Conditioner

Heating operation (Heat pump model only)

1

Press the Start/Stop button.

The unit will respond with

a beep.

Operating Instructions

<![if ! IE]>

<![endif]>ENGLISH

2Open the door of the remote controller. To select Heating Operation, press the Operation Mode Selection button.

Each time the button is pressed, the operation mode is shifted in the direction of the arrow.

Cooling

Auto

Healthy

Heating

 

 

Dehumidification (Heat pump model only)

3

Close the door of the remote controller.

Set the temperature higher than the room temperature.

 

The temperature can be set within a range of 16°C~30°C at

 

intervals of 1°C.

ON

To raise the temperature

 

 

To lower the temperature

4

Set the fan speed again with the door of the

remote controller still closed. You can

select the fan speed in four steps–low, medium, high and CHAOS. Each time the button is pressed, the fan speed mode is shifted.

Natural wind by the CHAOS logic

οFor fresher feeling, press the Indoor Fan Speed Selector and set to CHAOS mode. In this mode, the wind blows like a natural breeze by automatically changing fan speed according to the CHAOS logic.

Owner's Manual 19

Operating Instructions

Jet cool operation

1Press the Start/Stop button.

The unit will respond with

a beep.

2

Press the Jet Cool button to operate

the speed cooling mode and the unit

will operate at super high fan speed on cooling mode for 30 minutes.

3fan speed button or the room temperature setting button

again and the unit will operate at high fan speed on cooling mode.To cancel the Jet Cool mode, press the Jet Cool button, the

or or

NOTICE

οDuring the JET COOL function at any moment, the A/C starts to blow the cool air at extremely high speed for 30 minutes setting the room temp. automatically to 18°C. It is especially used to cool the room temp. quickly in a hot summer.

In heat pump mode, neuro fuzzy mode, or auto changeover mode however, the JET COOL function is not available.

οIn order to return to the normal cooling mode from the JET COOL mode, just press the operation mode selection button, airflow volume selection, temp. setting button or the JET COOL button again.

20 Room Air Conditioner

Jet heat operation (Optional)

1

Press the Start/Stop button.

The unit will respond with

a beep.

Operating Instructions

<![if ! IE]>

<![endif]>ENGLISH

2Open the door of the remote controller. To select Heating Operation.

Cooling

Auto

Healthy

Heating

 

changeover

Dehumidification (Heat pump model only)

3

Press the Jet Heat button to operate the

speed heating mode and the unit will

operate at super high fan speed on heating mode for 60 minutes.

ON

4the fan speed button or the room temperature settingTo cancel the Jet Heat mode, press the Jet Heat button,

button again and the unit will operate at high fan speed on heating mode.

or or

NOTICE

οDuring the JET HEAT function at any moment, the A/C starts to blow the heat air at extremely high speed for

60 minutes setting the room temp. automatically to 30°C. It is especially used to heat the room temp. quickly in a cool winter.

On cooling, healthy dehumidification mode or auto changeover mode, however, the JET HEAT function is not available.

οIn order to return to the normal heating mode from the JET HEAT mode, just press the operation mode selection button, airflow volume selection, temp. setting button or the JET HEAT button again.

Owner's Manual 21

Operating Instructions

NEO PLASMA purification operation(Optional)

1Press the Start/Stop button.

The unit will respond with a

beep.

2Open the door of the remote controller. Press the PLASMA

button.

Operation will start when the button is pressed and stop when the button is pressed again.

Set the fan speed again with the door of the remote 3 controller closed. You can select the fan speed in four

steps-low, medium, high or CHAOS. Each time the button is pressed, the fan

speed mode is shifted.

η Air purifying operation (PLASMA) can be with cooling, Heating or any other operations.

NEO PLASMA Air Purifying Operation only

If you press the only PLASMA button, only

PLASMA purification function operates.

Then, fan speed is low. You can select the fan speed in four steps-low, medium, high or CHAOS.

Each time the button ( ) is pressed, the fan speed mode is shifted.

22 Room Air Conditioner

2nd F operation

Operating Instructions

<![if ! IE]>

<![endif]>ENGLISH

1Press the Start/Stop button. The unit will respond with

a beep.

2

Open the door of the remote control and press the 2nd

Function button to operate functions printed in blue unter

 

buttons.

 

 

 

(Check the indication of 2nd function on the display of the

 

remote controller.)

 

 

 

These buttons can set the timer as follows:

 

 

ON

OFF

SET

 

 

CANCEL

ON

OFF

SET

 

 

AUTO CLEAN

2nd function disappears in a short time automatically or when 3 the button is pressed again.

For more details, refer to functions next pages.

Owner's Manual 23

Operating Instructions

Additional Features

Sleep mode

1.Press the Sleep Mode Auto button to set the time you want the unit to stop automatically.

2.The Timer is programmed in one-hour increments by pressing the Sleep Mode Auto button 1 to 7 times. The sleep mode is available for 1 to 7 times. To alter the time period in steps of 1 hour, press the Sleep Mode Button while aiming at air conditioner.

3.Make sure the Sleep Mode Auto LED lights up.

To cancel the Sleep Mode, press the sleep Mode Auto button several times until the star () disappears from the operation display.

NOTICE The Sleep Mode will be operated at slow fan speed (cooling) or medium fan speed (heat pump only) for a comfortable sleep.

In cooling mode or healthydehumidification mode:

The temperature will automatically rise by 1°C over the next 30 minutes and by 2°C in 1 hour for a comfortable sleep.

Setting the time

1. Time can be set only when you press the Reset button. Having replacing the batteries, you should press the reset buttons to reset the time. Press the Start/Stop button.

2. Press 2nd F button and check if 2nd F icon is on.

3. Press the Time Setting buttons until the desired time is set.

CANCEL

4. Press the Timer SET button.

NOTICE Check the indicator for A.M. and P.M.

Delay start/Pre-set stop

1. Make sure the time is set correctly on the display of the remote controller.

2. Press 2nd F button.

3. Press the ON/OFF Timer buttons to turn Timer on or off.

ON OFF

 

4. Press the Time Setting buttons until the desired time is set.

CANCEL

5. To set the selected time, press the Timer setting button aiming the remote controller at the signal receptor.

To cancel the timer setting

Check if 2nd F icon is off. CANCEL Press the Timer Cancel button aiming the remote controller at the signal receptor. (The timer lamp on the air conditioner and the display will go out.)

NOTICE Select one of the following four types of operation.

with the unit running

Delay OFF Timer

Delay ON Timer

Delay OFF and ON Timer Delay ON and OFF Timer

24 Room Air Conditioner

Operating Instructions

Airflow direction control

The up/down and right/left airflow can be adjusted by

Press Chaos Swing button and the louvers will swing.

using the remote control.

 

 

Press the button again and the louvers will stop. After

 

30 minutes, the louvers return to the maximum airflow

Press the Start/Stop button to start the unit.

position automatically.

Air circulation mode

Circulates the room air without cooling or heating.

1.Press the Start/Stop button. the unit will respond with a beep.

2.Open the door on the remote control. Press the Air Circulation button. Close the door on the remote control. Now each time that you press the Indoor Fan Speed Selector, the fan speed is shifted from low to CHAOS and back to low again.

<![if ! IE]>

<![endif]>ENGLISH

CHAOS Air

Fan speed is on low. Fan speed is on medium. Fan speed is on high.

NOTICE CHAOS Air economizes power consumption and prevents overcooling. The fan speed is automatically changed from high to low or vice versa, depending on the ambient temperature.

Auto clean

1.Whenever you press the Auto Clean button, Auto Clean Function will be reserved and cancelled.

2.Auto Clean function works before and after cooling or dehumidification mode. For details, refer to

AUTO CLEAN

the below points.

3.When the unit is started after the reservation of Auto Clean ,the Cool Start function operates and indoor Fan is started after 20 seconds.

4.When you press Start/Stop button to turn off the unit after the you have reserved Auto Clean function, the air-conditioner circulates the indoor air in the Auto Clean mode with no more Cooling or Dehumidification operation. For Cooling only model, it lasts for 30 minutes for Heat pump model, for 16 minutes.

5.If you press the auto clean button again during the product operation , Auto Clean function will be cancelled.

NOTICE

οDuring Auto Clean function, moistures left in indoor units after Cooling Operation or Healthy Dehumidification Operation can be removed.

οDuring Auto Clean function, only Start/Stop button, Plasma button and Auto Clean button are available.

Owner's Manual 25

Operating Instructions

Forced operation

Operation procedures when the remote control can't be used.

The operation will be started if the power button is pressed.

If you want to stop operation, re-press the button.

 

 

 

Power button

 

 

Cooling Model

 

Heat pump Model

 

 

Room Temp. ≥ 24°C

21°C ≤ Room Temp. < 24°C

Room Temp. < 21°C

 

 

Operating mode

Cooling

Cooling

Healthy Dehumidification

Heating

Indoor FAN Speed

High

High

High

High

Setting Temperature

22°C

22°C

23°C

24°C

Test operation

During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room temperature and resets in 18 minutes.

During test operation, if remote controller signal is received, the unit operates as remote controller sets.

If you want to use this operation, Press and hold the ON/OFF button for 3~5 seconds, then the buzzer sound 1

"beep".

If you want to stop the operation, re-press the button.

Auto restart

In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate procedures automatically to the previous operating conditions.

So there is no need of activating this function by pressing any key or button.

In the initial mode, the fan operates at a low speed and the compressor starts 2.5~3 minutes later.

As the compressor starts, the fan speed also resumes its previous setting mode.

Helpful information

Fan speed and cooling capacity.

The cooling capacity indicated in the specification is the value when the fan speed is set to high, and the capacity will be lower at low or medium fan speed.

High fan speed is recommended when you wish to cool the room quickly.

High

Speed

NOTICE

Auto restart function has set enable as factory default.

But customer can set up by following this instruction.

To be disable function

-Press and hold the ON/OFF button for 6 seconds, The unit will beep twice and the lamp will blink twice 4 times.

To be enable function

-Press and hold the ON/OFF button for 6 seconds, then the buzzer sound 2 "beep" and the indicator lamp (1) brights 4 times.

26 Room Air Conditioner

Maintenance and Service

Maintenance and Service

Indoor Unit

WARNING: Turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives.

NOTICE Supply power must be disconnected before cleaning the indoor unit.

Air filter

The air filters behind the front grill should be checked and cleaned once every 2 weeks or more often if neccessary. 1. Pull up the front panel.

After supporting front panel with supporter. 2. Take the filter out slowly.

NOTICE Clean the filter after stopping the product.

3. Clean the filter with a vacuum or warm, soapy water.

• If dirt is conspicuous, wash with a solution of detergent in lukewarm water.

• If hot water (40°C or more) is used, it may be

 

deformed.

 

4. Re-install the air filter.

Filter

Never use any of the followings:

• Water hotter than 40°C.

Could cause deformation and/or discoloration.

• Volatile substances

Could damage the surfaces of the air conditioner.

<![if ! IE]>

<![endif]>ENGLISH

Outdoor Unit

The heat exchanger coils and panel vents of the outdoor unit should be checked regularly.

If clogged with dirt or soot, the heat exchanger and panel vents may be professionally steam cleaned.

NOTICE Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs.

Air Intake Vents

Connecting

Wires

Piping

Air Outlet Vents

Base Plate

Drain Hose

 

Owner's Manual 27

Maintenance and Service

Cleaning Filter

1.Turn off power & pull out the front panel with both hands.

2. Support front panel using the supporter

3. Take out filter with both hands.

4. Remove the plasma filters

WARNING: Don't touch the PLASMA Filter within 10 seconds after opening the inlet grille, it may cause electric shock.

5.Put the plasma filters neutral detergent for 1~2 hours and then raise them

6.Insert the plasma filters after perfectly drying them in shade

7.Insert air filter with both hands and withdraw supporter.

8.Push the middle of front using two hands.

28 Room Air Conditioner

LG A18LHU User Manual

Maintenance and Service

Changing Picture

1. Unlock locker on the bottom of panel.

2. Open the frame.

5.Turn upside-down of the picture and turn over mat, then take off a protective attached of the mat.

Mat

6.Place the picture/photegraph vetween the exited picture and mat.

(It is suitable for picture and photograph to be 785x380)

Mat

3. Use suppoter(2EA) to support frame.

7. Insert another picture.

 

4. Take out picture.

WARNING: Make sure picture is fixed

 

 

by rib.

 

8. Lock locker & Fix it.

<![if ! IE]>

<![endif]>ENGLISH

Owner's Manual 29

Maintenance and Service

Common Problems and Solutions

Before calling for service

If you have problems with your air conditioner, read the following information and try to solve the problem. If you cannot find a solution, turn off the air conditioner and contact your dealer.

Air conditioner does not operate

1.Ensure that the air conditioner is plugged into a proper outlet.

2.Check the fuse or circuit breaker.

3.Check whether the voltage is unusually high or low.

Air does not feel cold enough on the cooling setting

1.Ensure that the temperature settings are correct.

2.Check to see if the air filter is clogged with dust. If so, replace the filter.

3.Ensure that the air flow from the outside is not obstructed and that there is a clearance of over 20" between the back of the air conditioner and the wall or fence behind it.

4.Close all doors and windows and check for any source of heat in the room.

Before calling for service, please review the following list of common problems and solutions.

The air conditioner is operating normally when:

You hear a pinging noise. This is caused by water being picked up by the fan on rainy days or in highly humid conditions. This feature is designed to help remove moisture in the air and improve cooling efficiency.

You hear the thermostat click. This is caused by the compressor cycle starting and stopping.

You see water dripping from the rear of the unit. Water may be collected in the base pan in highly humid conditions or on rainy days. This water overflows and drips from the rear of the unit.

You hear the fan running while the compressor is silent. This is a normal operational feature.

30 Room Air Conditioner

Loading...
+ 67 hidden pages