(60X6 PANEL) The Following Models use the 60X6 Panel (2006)
60PC1D / DR / 60PY2R / 2D / 2DR / 60PZ9M / MA
(60X7 PANEL) The Following Models use the 60X7 Panel (2006)
60PB4DA / DR / DT
(71H2 PANEL) The Following Models use the 71H2 Panel (2006)
71PY1M
Intentionally left blank
42G1 PANEL
42G1 PANEL
QUICK REFERENCE
QUICK REFERENCE
ALIGNMENT HAND BOOK
ALIGNMENT HAND BOOK
MODELS USING THE 42G1 PANEL
42PG20
42PG25
Intentionally left blank
42G1 VS / VA ADJUSTMENT
PREPARATION:
1.) Pre-Heat unit for at least 10
Minutes before making adjustments.
2.) Place unit into White Wash from the Customer’s
Menu for all adjustments.
3.) Be sure to use all adjustment values as
indicated on the panel voltage label in the
upper left hand corner of the panel. (Example above)
PROCEDURE: (See preceding figure for locations)
1.) Adjust VS using VR951. Measured from Pin 1 P812
to chassis ground. Match Panel Voltage label ±1V.
2.) Adjust VA using VR901. Measured from Pin 6 P812
to chassis ground. Match Panel Voltage label ±1V.
42G1 PANEL
42G1 Y-SUS BOARD ADJUSTMENT POINTS
V SET DOWN set too high
can cause shut down.
If this happens, remove the LVDS cable and
pre-alighn adjustments.
42G1 PANEL
42G1 Y-SUS ADJUSTMENT PREPARATION:
PREPARATION:
1.) Pre-Heat unit for at least 10
Minutes before making adjustments.
2.) Place unit into White Wash from the Customer’s
Menu for all adjustments.
3.) Be sure to use all adjustment values as
indicated on the panel voltage label in the
upper left hand corner of the panel. (Example above)
PROCEDURE: (See figures for locations)
1) Adjust -Vy using VR501. Measured across R210.
Match Panel Voltage label ±1V.
2) Adjust VSC using VR502. Measured across R211
Match Panel Voltage label ±1V.
42G1 PANEL
Voltage Reads Positive
-
-Vy TP R210
+
Lower Left Side
of Board
VR502
VR501
-
VSC TP R211
-Vy Adj
VSC Adj
+
Middle Left Side of Board
Lower Left Side of Board
42G1 Y-Drive Waveform Test Point
Figure 1 shows the Y-Drive Waveform Test Point on the Center Top
Y-Drive PWB. Indicated by the Arrow. Use this TP for alignment of the
Y-Drive signal using Set-Up and Set-Down adjustments shown on the
next page.
(Fig. 1)
Y Drive
Waveform TP
Top Y-Drive board.
42G1 PANEL
Observing the Y-SUS and Z-SUS Output Waveforms
External Triggering of the Oscilloscope allows for a Stable
Display of both the Y and Z SUS Output Waveforms
regardless of how distorted the waveforms may be,
allowing the wave shape and phasing to be easily
examined.
To set the Oscilloscope up for External Trigger first connect
a Scope Probe set on direct to the External Input Jack.
Next set the External Jack for AC Coupling either positive or
negative slope, use the Trigger Menu on the Scope.
Finally you will need to set the Trigger Level press the
Trigger View and set the level as indicated in the picture
below.
42G1 PANEL
VS_DA Located on the Control Board just above the AUTO
Gen Test Points may be used as an external trigger source
Trigger Level Adjust
for locking the waveform on the Oscilloscope
42G1 Y-DRIVE WAVEFORM ADJUSTMENT
PRELIMINARY:
Adjustment locations for adjusting the Y-Drive waveform on the Y-SUS
PWB shown below.
See Y-SUS Test Points and Adjustments diagram for detailed
locations. (4 pages back).
See next page for Adjustment specifications.
Top Left of PWB
Set-Dn
VR401
B
Set-Up
VR601
A
42G1 PANEL
42G1 Y-SUS ADJUSTMENT PREPARATION:
PREPARATION:
1)All adjustment preliminary preparations should be the same as
for Va and Vs adjustments.
2)Va, Vs, -Vy, and VSC adjustments should be complete.
3)Be sure to use all adjustment values as
indicated on the panel voltage label in the upper left hand
corner of the panel.
PROCEDURE: (See preceding page for locations)
Connect scope to Waveform TP on Y-Drive PWB.
1) Adjust RAMP until point “A”in
diagram below is
150V p / p ±5V.
42G1 PANEL
2) Adjust V SET-DOWN until
point “B” in diagram below is
110uSec ±5uS
A
B
42G1 Y-SUS BOARD Z-SUS ADJUSTMENT POINTS
Z-Bias Adjustment Section of
the Y-SUS PWB
42G1 PANEL
42G1 Z-SUS ADJUSTMENT PREPARATION:
PREPARATION:
1.) Pre-Heat unit for at least 10
Minutes before making adjustments.
2.) Place unit into White Wash from the
Customer’s Menu for all adjustments.
3.) All other adjustments should be complete.
4.) Be sure to use all adjustment values as indicated on the panel
voltage label in the upper left hand corner of the panel.
(Example above)
PROCEDURE: (See preceding page for locations)
1.) Place DC Volt meter on VZB TP (Across R946 on the
Y-SUS Board).
2.) Adjust VZB (Z Bias) VR905 in accordance to your Panel’s
voltage label.
42G1 PANEL
Z-Bias Adj
VR905
+
-
Z-Bias TP
Bottom right side of Y-SUS PWB
R946
Intentionally left blank
42G2 PLASMA PANEL
42G2 PLASMA PANEL
QUICK REFERENCE
QUICK REFERENCE
ALIGNMENT HAND BOOK
ALIGNMENT HAND BOOK
MODELS USING THE 42G2 PANEL
42PQ20
42PQ30
Intentionally left blank
42G2 SMPS BOARD ADJUSTMENT POINTS
These two voltages are adjustable and should be adjusted to the
correct values as indicated by the panel label.
Example shown in the outlined area below.
Always adjust “Highest to Lowest” voltages.
VS and VA adjustment resistors are shown in the drawing below.
They are located towards the top right hand side of the board.
VR901 is the VS adjustment pot.
VR502 is the VA adjustment pot.
Set should be in “Full White Raster”
1) VS ADJUST: Connect DVM to pin 1 or 2 of P811. Adjust VR901 until
the voltage matches the panel’s voltage label.
2) VA ADJUST: Connect DVM to pin 9 or 10 of P811. Adjust VR502 until
the voltage matches the panel’s voltage label.
42G2 PANEL
All measurements taken from Chassis Gnd.
42G2 Y-SUS BOARD ADJUSTMENT POINTS
42G2 PANEL
VSC and –Vy Voltage Adjustment Locations
These voltages are adjustable and
Should be adjusted to the correct
values as indicated by the panel’s
voltage label.
Example shown to the right.
-Vy (VR502) variable resistor located bottom center of the board.
Adjust the -Vy (VR502) while reading across R201.
Match your specific panel’s voltage label.
VSC (VR501) variable resistor located bottom center of the board.
42G2 PANEL
Adjust the VSC (VR501) while reading between left side R520 and TP just above R520. Match your specific panel’s voltage label.
VSC TP
Measure
Across TPs
-Vy TP
Across
VR201
VSC
VR501
-VY
VR502
42G2 Y-Drive Waveform Test Point
Figure 1 shows the Y-Drive PWB with the area of the Waveform TP
outlined in the Red circle.
Use this TP for alignment of the Y-Drive signal using Set-Up and SetDown adjustments shown on the next page.
Y-DRIVE
Y Drive
Waveform TP
42G2 PANEL
Y-SUS
(Fig. 1)
42G2 Y-DRIVE WAVEFORM ADJUSTMENT
VS, VA, VSC, -Vy should have been completed.
See Y-SUS Test
Using a Full White Raster, adjust the
Set-up and Set-dn section of the Y-Drive
waveform.
Oscilloscope TP “Waveform” TP
on the Y-Drive PWB.
(A) Set-Up: Adjust VR601 while observing
area (A) and set to 160V ± 1V.
(B) Set-Down: Adjust VR401 while
observing area (B) and set to
42G2 PANEL
185uSec ± 5uSec.
Points and
Adjustments diagram
for locations.
A
B
A
B
42G2 Z-SUS BOARD ADJUSTMENT POINTS
The above picture represents a 42G2 Panel Voltage Label. This is for an
example only. You should adjust your set’s
Z-Bias adjustment to your specific Panel’s Voltage Label not this book.
The picture below represents the 42G2 Z-SUS PWB. Use this for
reference to locate the Adjustment control and the adjustment Test
Points.
42G2 PANEL
42G2 Z-SUS BOARD ADJUSTMENT POINTS
VS, VA, VSC, -Vy should have been completed.
Full White Raster
1) Z-Bias TP: Connect DVM (+) right side R49 or R50 to
Chassis Gnd.
2) Adjust Z-Bias (VR8) to match your specific panel’s
42G2 PANEL
voltage label.
Z Bias Test Point
Right Side of either R49 or 50
To Chassis Ground
Z Bias Adjust
VR8
Same as Chassis Gnd.
Intentionally left blank