3
Specications Package Contents Safety Information Getting to Know Your Humidier
Display Getting Started Operation
ɧ General Operation
Using the Aroma Box
Preventing Water Leaks Keeping Things Clean
ɧ General Cleaning ɧ Cleaning the Aroma Pad ɧ Disinfecting the Humidifier
Troubleshooting
Warranty Information Customer Support
4 4 5 7 8 10 12 12 13 15 17 17 18 18 19 21 22
TABLE OF CONTENTS
Page 4
4
Voltage: Rated Power:
Eective Range: Water Tank Capacity:
Moisture Output:
ɧ Mode 1: ɧ Mode 2: ɧ Mode 3: ɧ Mode 4:
Operation Times:
ɧ Mode 1: ɧ Mode 2: ɧ Mode 3: ɧ Mode 4:
AC 120V, 60Hz
30W
430.5 - 538.2 ft² (40 - 50 m²)
1.1 gal (4.5 L)
100 mL/h 150 mL/h 200 mL/h 250 mL/h
40 hours 25 hours 20 hours 15 hours
1 x Ultrasonic Cool Mist Humidier 1 x Cleaning Brush (Attached) 3 x Aroma Pads (1 Pre-Installed)
1 x User Manual
SPECIFICATIONS
PACKAGE CONTENTS
Page 5
5
SAFETY INFORMATION
To reduce the risk of re, electric shock, or other injury, follow all instructions and safety
guidelines.
Only use this humidier as described in this manual.
• Place the humidier and cord so that the humidier will not be knocked over.
• Ensure that the plug ts properly into a polarized power socket.
• When not in use, turn the machine o and disconnect from a power source by removing the plug from the outlet.
• Do not overll the water tank as it may cause electric shock.
• Do not handle the power cord or plug with wet hands. Keep the power cord and plug away from liquids.
• Do not use this humidier in wet environments.
• Keep the humidier out of reach from children.
• Do not open the base or remove the water level sensor for self-servicing. Doing so will void your warranty and may increase the risk of electric shock, injury, or damage to the humidier.
• Always unplug your humidier from the power outlet before cleaning your humidier or detaching the water tank from the humidier base.
General Safety
• Direct the nozzle so that the mist is at least 40 inches (102 cm) from walls.
• Only ll the water tank with clean water. Never ll the water tank with any other liquids.
• Do not place the humidier near sources of heat, such as stovetops, ovens, or radiators.
• Do not place the humidier directly on oors, carpets, or rugs.
• Do not cover the nozzle while the humidier is on. Doing so may damage the humidier.
Use & Care
Page 6
6
Do not shake
the humidier.
Do not place
humidier on an inclined surface.
Do not place
humidier directly against walls.
Always make sure there is a 10-inch (25 cm) clearance from walls.
IMPORTANT
• If the relative humidity in your room exceeds 68%, turn o the device or use the low mist setting.
• Remove the water tank from the base before moving the humidier.
• Do not immerse the humidier base, power cord, or plug in water.
• Always clean the humidier as instructed in this manual (see Keeping Things Clean, page 16).
• If the humidier is damaged or is not functioning properly, stop using it and contact
Customer Support immediately (page 22).
READ AND SAVE THESE
INSTRUCTIONS
Page 7
7
GETTING TO KNOW YOUR HUMIDIFIER
1. Nozzle
2. Top Cover
3. Water Tank
Handle
4. Mist Tube
5. Water Tank
6. Water Tank
Window
7. Water Tank Cap
8. Cleaning Brush
9. Cleaning Brush
Storage
10. Base
11. Inner Chamber
12. Air Vent
13. Transducer
14. Water Level
Sensor
15. Blue Night Light
16. Display & Control Panel
17. Aroma Box
18. Aroma Pad
19. Power Cord
1
2 3
5
4
6
7
8
9
17
18
19
13
12
14
15
10
16
11
Page 8
8
GETTING STARTED
1. Remove the top cover from the water tank and set it aside. [Figure 1.1] Carefully lift the water tank handle to detach the water tank from the base.
2. Flip the water tank over and twist open the water tank cap. [Figure 1.2]
NOTE:
• Fill the water tank with at least 2 cups of distilled water.
• Do not fill the water tank with hot water.
• Do not add water through the nozzle or mist tube.
• Do not lift the entire humidifier by the water tank handle.
3. Fill the water tank with cold or room temperature water. You can check the water level in the tank by looking through the water tank window. The maximum capacity of the water tank is 1.1 gallons (4.5 L). [Figure 1.3]
Figure 1.1
Figure 1.2 Figure 1.3
Page 9
9
4. Once you have lled the water tank, replace the cap, and secure it tightly. [Figure 1.4]
5. Carefully place the water tank back onto the base, aligning the water tank cap with the inner chamber. [Figure 1.5]
Figure 1.4
Figure 1.5
Page 10
10
1. Place the humidier on a level surface that is elevated, such as a table and a nightstand. Make sure the room is well­ventilated.
2. Plug the humidier into an electrical outlet.
3. Tap once to turn on the humidier. a. If there is no water in the tank,
will light up. Unplug the humidier and rell the water tank. See Getting Started (page 10).
b. If the last humidity setting is lower
than the humidity level of the environment, it will release mist for a few seconds and then stop misting.
4. Tap and hold and for 3 seconds clear all previous settings.
5. When the water level is low, your humidier will stop misting.
OPERATION
General Operation
NOTE:
• The nozzle can rotate 360° to diuse mist in any direction.
• The night light will remain on if the humidifier shuts o due to low water level.
• The humidifier will stop misting if the water tank is detached from the base.
• When turned on, if there is water in the tank, the humidifier has a memory function that will recall the last setting used before it was turned o or unplugged.
• If this is the first use, the default mist setting is mode 4 ( ).
NOTE: Make sure to position the humidifier at least 10 inches away from walls, and direct the nozzle so that the produced mist is at least 40 inches away from walls.
Page 11
11
Lights up when Auto Mode is selected. The humidier will produce mist as
needed to maintain the relative humidity
(RH) at a comfortable level.
Lights up when humidity mode is being changed.
DISPLAY
Lights up dimly when the display is turned o.
The time will count down every hour
when the timer has been set.
Shows the humidity percentage.
Lights up when the water tank needs to be relled.
Shows the mist level
Page 12
12
ON/OFF
• Tap to turn your humidier on or o.
TIMER – You can set a timer between 1 and 12 hours.
• Tap repeatedly to choose a time.
• When you stop pressing , the display will ash 3 times and the timer will start.
• The humidier will automatically power o once the timer is nished. Press and hold for 2 seconds or tap repeatedly until it shows “-H” to exit the timer function.
HUMIDITY – You can set the humidity level between 30% and 80%.
• Tap repeatedly to change the humidity level, which increases by 5% each tap.
• Once the humidity level of the environment reaches the set humidity level, the mist will automatically turn o.
• To cancel the humidity function, tap repeatedly until “Co” appears on the display or press and hold for 2 seconds. The humidier will enter auto mode after cancellation.
MIST LEVEL – You can choose between mist levels 1 through 4 or auto mode.
• Tap repeatedly to choose mist level.
LIGHT
• Tap to turn the water tank night light on or o.
• Tap and hold for 2 seconds to turn o the display. The will be dimly lit when the display is o.
Page 13
13
USING THE AROMA BOX
Your humidier can be used as an aroma diuser to provide added comfort in your home.
1. Turn o and unplug the humidier.
2. Locate the aroma box at the back of the base. [Figure 3.1]
3. Push the aroma box to release it from the base, then pull it out. [Figures 3.2 & 3.3]
Figure 3.1
Figure 3.2
Figure 3.3
Page 14
14
4. Put 2-3 drops of essential oil on the aroma pad. [Figure 3.4]
5. Replace the aroma box. Fill the water tank with water and place it back on the base (see Getting Started, page 10). [Figure 3.5]
6. Plug in and turn on the humidier.
Figure 3.4
Figure 3.5
NOTE:
• You can also add medicated vaporizing steam liquid to the aroma pad.
• The aroma pad can be cleaned and reused after diusing essential oils (see page 18).
Page 15
15
PREVENTING WATER LEAKS
If not placed properly, the water tank on your humidier may leak. The following tips will ensure that your humidier operates smoothly.
1. Make sure the blue silicone ring around the water tank cap is secured at all times. [Figure 4.1]
Inside of water tank cap
2. Twist and secure the cap tightly onto the water tank. [Figure 4.2]
3. Before moving the humidier, remove the tank from the base and empty any excess water inside the inner chamber. [Figures 4.3 & 4.4]
Figure 4.1
Figure 4.2
Figure 4.3
Figure 4.4
NOTE: A small gap between the cap and the tank is normal.
Page 16
16
4. Wipe o any excess water on the top and bottom of the base. [Figure 4.5]
5. Do not shake the humidier or place it on an inclined surface. Make sure to place the humidier on a at, level surface. [Figure 4.6]
Figure 4.5
Figure 4.6
Page 17
17
KEEPING THINGS CLEAN
General Cleaning
CAUTION:
• Always make sure the humidier is unplugged from any power source when cleaning.
• The water in the inner chamber near the transducer may still be warm after turning o the humidier. Use caution when pouring out the water.
1. Unplug the humidier.
2. Remove the top cover from the water tank. Rinse the nozzle and the cover under clean, running water. Then set it aside to air dry.
3. Remove the water tank from the base and pour out any excess water. Fill the tank with 2 cups of distilled white vinegar and 2 cups of water. Replace the cap and gently shake to coat all sides of the water tank.
4. Fill the inner chamber with 1 cup of distilled vinegar. [Figure 5.1]
5. Allow the vinegar to soak inside both the water tank and inner chamber for 30 minutes.
6. Use the included cleaning brush to remove any scale buildup inside the water tank or in the inner chamber. [Figure 5.2]
7. Pour out the vinegar from both parts of the humidier and thoroughly rinse with warm water.
8. Dry all parts with a clean, dry cloth. Make sure all parts of the humidier are completely dry before reassembling or storing.
Figure 5.1 Figure 5.2
Inner chamber
Page 18
18
Cleaning the Aroma Pad Disinfecting the Humidier
1. Press the aroma box to release it from the base, then pull it out.
2. Remove the aroma pad from the aroma box.
3. Rinse the pad under warm, running water.
4. Dry with a clean cloth and place it back into the aroma box.
NOTE: .
• Do not pour liquid cleaners or detergents into
the aroma box.
• Do not use liquid cleaners or detergents to
wash the aroma pad.
1. Clean the water tank (see General Cleaning, page 17).
2. Fill the water tank with 1 teaspoon of bleach along with 1 gallon of clean water. Reseal the water tank, then gently shake the water tank to ensure all of the sides are coated with the mixture.
3. Add ¼ teaspoon of bleach along with 1 cup of clean water into the base.
4. Allow the solutions in both parts to sit for 30 minutes.
5. Pour out the mixtures from both the water tank and base. Rinse both parts thoroughly under clean, running water.
6. Allow the water tank and base to completely air dry before reassembling the humidier.
NOTE:
• Always wear gloves to protect your hands
while using bleach.
• A 3% hydrogen peroxide solution may also be
used to disinfect the humidifier.
• Do not use the humidifier immediately after
disinfecting, doing so may pose a potential health hazard.
Disinfect the water tank before or after storing the humidier for long periods of time. You should also disinfect if there is any mold buildup inside the water tank.
Page 19
19
TROUBLESHOOTING
Problem Cause Solution
No mist coming out
of nozzle.
Humider is not plugged in.
Plug the humidier into a powered electrical outlet.
Humider is not turned on.
Tap the power button to turn on the
humider.
No water in tank.
Add at least 2 cups of clean water into the water tank.
Water level is low.
Humidier produces an unusual smell.
Humider is new.
Rinse the water tank and allow the humidier to air dry.
Residual smell from diusing essential oil on the aroma pad.
Clean the water tank (see Keeping Things Clean, page 17).
Water has been in tank for too long.
Humidier makes
a loud or unusual
noise.
Water tank does not t properly.
Align the water tank cap with its
respective port inside the inner
chamber.
Water level is low.
Add at least two cups of clean water into the water tank.
Humider is not level. Place humider on a at, level surface.
Humider is malfunctioning.
Turn o and unplug the humidier.
Discontinue use and contact Customer Support (page 22).
Page 20
20
Problem Cause Solution
White dust appears
around the humidier after operation.
Water being used has a high mineral
content.
Use distilled, puried, or ltered water with the humidier. Remember to clean your water tank at least once a month.
Puddle of water forms below the base.
Mist setting is too high.
Switch the humidier to a lower mist setting.
Room is not well-ventilated.
Open a window to ensure proper
airow for your humidier, or move the humidier to a more well-ventilated room.
Excess water that has spilled from lling the water tank or replacing the water tank back onto the base.
Wipe o excess water from the top and bottom of the base before replacing the water tank.
Humidier base is leaking.
Unplug the humidier immediately and stop using it (see Preventing Water Leaks, page 14) before using it again. If your humidier continues to leak, contact Customer Support (page 22).
Some of the buttons are unresponsive.
Humidier is malfunctioning. Contact Customer Support (page 22).
Page 21
21
WARRANTY INFORMATION
TERMS & POLICY
Levoit warrants all products to be of the highest quality in material, craftsmanship, and service, eective from the date of purchase to the end of the warranty period.
Levoit will replace any product found to be defective due to manufacturer aws based on eligibility. Refunds are available within the rst 30 days of purchase. Refunds are only available to the original purchaser of the product. This warranty extends only to personal use and does not extend to any product that has been used for commercial, rental, or any other use in which the product is not intended for. There are no warranties other than the warranties expressly set forth with each product.
This warranty is non-transferrable. Levoit is not responsible in any way for any damages, losses, or inconveniences caused by equipment failure by user negligence, abuse, or
use noncompliant with the user manual or any additional
safety, use, or warnings included in the product packaging and manual.
This warranty does not apply to the following:
• Damage due to abuse, accident, alteration, misuse,
tampering or vandalism.
• Improper or inadequate maintenance.
• Damage in return transit.
• Unsupervised use by children under 18 years of age.
Levoit and its subsidiaries assume no liability for damage caused by the use of the product other than for its intended use or as instructed in the user manual. Some states do not allow this exclusion or limitation of incidental or consequential losses so the foregoing disclaimer may not apply to you. This warranty gives you specic legal
rights and you may also have other rights which may vary
from state to state.
ALL EXPRESSED AND IMPLIED WARRANTIES,
INCLUDING THE WARRANTY OF MERCHANTABILITY,
ARE LIMITED TO THE PERIOD OF THE
LIMITED WARRANTY.
Additional 1-Year Warranty
You can extend your 1-year warranty by an additional year. Log onto www.levoit.com/warranty and enter your order number (for example, from Amazon or Houzz) to register your new product for the extended warranty.
If you are unable to provide the order number for your product, please type a short note in the order number eld along with the date you received your product.
Defective Products & Returns
If your product proves defective within the specied warranty period, please contact Customer Support via [email protected] with your order number. Do not dispose of your product before contacting us. Once Customer Support has approved your request, please return the unit with a copy of the invoice or your order number.
Product Name Ultrasonic Cool Mist Humidier
Model Number LV455CH
Default Warranty Period 1 year
For your own reference, we strongly recommend that you
record your order number and date of purchase.
Date of Purchase
Order Number
Page 22
22
CUSTOMER SUPPORT
If you encounter any issues or have any questions regarding your new product, feel free to contact our helpful Customer Support Team. Your satisfaction is our goal!
Customer Support
Arovast Corporation 1202 N. Miller St., Suite A Anaheim, CA 92806
Toll-Free: (888) 726-8520
Support Hours
Monday - Friday 9:00 am - 5:00 pm PT
*Please have your invoice and order number ready before contacting Customer Support.
Page 23
23
Connect with us @LevoitLifestyle
Page 24
Levoit.com
Loading...