See the complete line of Z-Wave enabled dimmers, switches,
switches, outlet, fan speed controller and plug-ins at
leviton.com/decorasmart
3
Page 4
Welcome
WEB VERSION
We are here to help
CALL
1-8 00-82 4-3 005 (US A)
1-800-405-5320 (Canada)
ONLINE
decorasmartsupport.leviton.com
The Decora Smart
®
enabled Fan Speed
Z-W av e
Controller is designed for use with
modern Z-Wave hubs.
This product can be operated in
any Z-Wave network with other
Z-Wave certified devices from other
manufacturers. Your fan controller
will ac t as a repeater in the network
to increase the reliability of
the net work.
The Decora Smart Z-Wave fan
controller allows you to select one
of 4 fan speeds or turn your fan o
from a smartphone or tablet or by
voice when used with a Z-Wave hub.
The Decora Smart fan controller
looks at home with your other
®
Decora
convenient manual on/o control,
and an integrated bar to provide
easy speed adjustment and hidden
indicator lights.
TM
branded
branded products. It has
CHAT
www.leviton.com/contactus
EMAIL
dssupport@leviton.com
4
Page 5
What you need
WEB VERSION
to make it work:
To install your Z-Wave enabled fan speed controller:
1. A Z-Wave compatible hub.
2. A Z-Wave mesh network to join within 30
feet of installation location. To ensure proper
communication, do not use with metal wallplates.
LOAD
LINE
3. An available interior wallbox with a hot, neutral,
NEUTRAL
GROUND
4. For use with one or more ceiling paddle fans with
5. If the fan is controlled from more than one location,
RATINGS
Fan Motor Fan Motor1.5A - 120VAC, 60Hz
Oper
ating Temp0°C - 40°C (32°F - 104°F)
Operating Humidity0-90% non-condensing
NETWORK
Z-Wave Plus908.42 MHz
5
fan load and ground wire.
WAR NIN G: Do not use with aluminum wire.
split-capacitor or shaded pole motors, not to exceed
a total of 1.5A. Not for use with lighting loads
including ceiling fan light kits.
you will need a DD00R remote. See the DD00R
installation instructions for wiring instructions.
5
Page 6
Features
WEB VERSION
Rocker
Manually turn fan on/o.
Speed indicator lights
Show fan speed when
adjusting levels.
Status light
Illuminates when fan is o.
Fan speed bar
Manually adjust speed.
Air gap switch
This feature will stop power to the
fan. Gently pull bottom out until a
click is heard. Power to the fan and
indicator lights will turn o.
After servicing is complete, push
back in for normal operation.
6
Page 7
Identify your wires
WEB VERSION
For additional support contact technical services (page 4).
NOTE: Z-Wave is a mesh network. Ensure
your device is installed within 30 feet of
the hub or another Z-Wave enabled device.
Communication through exterior surfaces will
likely reduce transmission distances.
WARNING: TO AVOID FIRE, SHOCK OR DEATH,
turn o power at the circuit breaker.
Check your wallbox and identify your wires:
1. Remove wallplate and disconnect switch.
2. Restore power. Carefully test wires with voltage tester to find the line
(hot) wire.
3. Turn o power at the circuit breaker.
4. Mark the wires as shown below. Neutral wires are required to operate
this device.
Quick Tip: Neutral wires are
typicall white and may be found
bundled inside the back of
the switch box.
LOAD
LINE
To F an
Two white
(neut ral)
wires
NEUTRAL
GROUND
line (hot) wire
(find with voltage tester)
From
Branch Circuit
If your wallbox looks dierent,
call an electrician.
7
Page 8
Wire your fan controller
WEB VERSION
WARNING: TO AVOID FIRE, SHOCK OR DEATH, turn o power at the
circuit breaker.
1. Work on only one connection at a time.
2. Connect wires as shown.
3. Secure wire connections.
To F an
LOAD
NEUTRAL
LINE
GROUND
TRAVELER
From
This wire is used in
3-way installations only.
Branch Circuit
If your wallbox looks dierent,
8
call an electrician.
Page 9
Test and install
WEB VERSION
1. Gently push wires into wallbox. Do not overtighten wallbox screws.
2. Install wallplate base and snap on Decora wallplate.
Congratulations!
Your Z-Wave enabled fan
controller wiring is complete
3. Restore power.
9
Page 10
SmartStart
WEB VERSION
Your Decora Smart branded Fan Speed Controller is
compatible with SmartStart
SmartStart enabled products can be added into a Z-Wave network
by scanning the Z-Wave QR Code found on the top of the controller
or the back of the box with a controller providing SmartStart
inclusion. No further action is required and the SmartStart product
will be added automatically within 10 minutes of being switched on
and in the network vicinity.
The QR Code and DSK is found on
the top of the Fan Speed Controller.
If required, the pin code is underlined
on the label.
This image is an example, please use the code found on the
product or product packaging.
10
Page 11
Adding Your Fan Controller
WEB VERSION
to A Hub
Leviton Decora Smart branded Z-Wave enabled products support two
methods of inclusion. When using a Z-Wave Plus certified controller
choose Network Wide Inclusion or SmartStart. If network wide inclusion
does not discover your device, try classic inclusion.
Network Wide Inclusion to A Z-Wave Network
Modern Z-Wave Plus hubs support network wide inclusion which allows
your device to be included into the network using devices already
paired to your home automation hub.
Start with the devices closest to the hub and work your
way outward.
1. To enter programming mode, hold the top of the paddle for
7 seconds. The status light will turn amber, release and the
status light will blink.
2. Tap the top of the paddle 1 time. The status light will quickly
flash green.
3. The fan controller is now ready to learn into the Z-Wave network.
Follow directions for the Z-Wave controller to complete the
process.
4. Upon successful addition to network the status light will turn o
and then flash green 4 times. If it was not successfully added to
the network, the status light will flash red 4 times.
Classic Inclusion To A Z-Wave Network
For older controllers Classic Inclusion is suppor ted. Depending on the
age of the controller it will need to be 3 to 35 feet from the device
when including.
1. To enter programming mode, hold the top of the paddle for
7 seconds. The status light will turn amber. Release and the
status light will blink.
2. Follow the Z-Wave controller instructions to enter inclusion mode.
3. Tap the top or the paddle of the paddle one time. The status light
will quickly flash green.
4. The Z-Wave controller will confirm successful inclusion to the
network.
11
Page 12
Exclusion From A Z-Wave Network
WEB VERSION
When removing a fan speed controller from a Z-Wave network, it is
best practice to use the exclusion command found in the Z-Wave
controller.
1. To enter programming mode, hold the top of the paddle for
7 seconds. The status light will turn amber. Release and the
status light will blink.
2. Follow Z-Wave controller directions to enter exclusion mode.
3. Tap the the top of the paddle 1 time. The status light will quickly
flash green.
4. The Z-Wave controller will remove the device from the network.
Factory Default
When removing a fan speed controller from a network,
it is best practice to use the exclusion process. In situations
where a device needs to be returned to
factory default follow the steps below.
A reset should only be used when
a controller is inoperable or missing.
1. Hold the top of the paddle for
7 seconds, the status light will turn
amber. Continue holding the top of the
paddle for another 7 seconds (total
of 14 seconds). The status light will
quickly flash red/amber.
2. Release the top of the paddle and the
device will reset.
12
Page 13
Customization
WEB VERSION
Status Light Setup
The Leviton Decora Smart Z-Wave fan speed controller has a status
light. The functionality of this light can be changed.
Status Mode: Status Light On when the fan is On
The status light shows the current state of the fan:
1. To enter programming mode, hold the top of the paddle for
7 seconds. The status light will turn amber. Release and the
status light will blink.
2. Tap the top of the paddle 4 times. The status light will quickly flash
green/amber.
3. Tap the top of the paddle 1 time. The status light will flash green
4 times to confirm the selection.
Status Light On when the Fan is O
The status light is used to easily find the fan controller in a dark room:
1. To enter programming mode, hold the top of the paddle for
7 seconds. The status light will turn amber. Release and the
status light will blink.
2. Tap the top of the paddle 4 times. The status light will quickly
flash green/amber.
3. Tap the top of the paddle 2 times. The status light will flash amber
4 times to confirm the selection.
Status Light is always O
1. To enter programming mode, hold the top of the paddle for
7 seconds. The status light will turn amber. Release and the
status light will blink.
2. Tap the top of the paddle 4 times. The status light will quickly
flash green/amber.
3. Tap the top of the paddle 3 times. The status light will flash red
4 times to confirm the selection.
13
Page 14
Customization (cont'd)
WEB VERSION
Minimum and Maximum Speed Setup
The Leviton Decora Smart Z-Wave fan speed controller has a the
ability to set the maximum and minimum speed. The maximum
speed may be set lower than the fastest speed to prevent
wobbling and the slowest speed can be increased for larger fans
which may struggle to turn on at the lowest level.
Set Fan Minimum Speed Level:
1. To enter programming mode, hold the top of the paddle for
7 seconds. The status light will turn amber. Release and the
status light will blink.
2. Tap the top of the paddle 5 times. The status light will quickly
flash red/amber.
3. Tap the top of the paddle 1 time. The status light will
flash amber.
4. Use the fan speed bar to adjust the minimum fan speed.
5. Hold the top of the paddle to exit.
Set Fan Maximum Speed Level:
1. To enter programming mode, hold the top of the paddle for
7 seconds. The status light will turn amber. Release and the
status light will blink.
2. Tap the top of the paddle 5 times. The status light will quickly
flash red/amber.
3. Tap the top of the paddle 2 times. The status light will flash red.
4. Use the fan speed bar to adjust the maximum fan speed.
5. Hold the top of the paddle to exit.
14
Page 15
Customization (cont'd)
WEB VERSION
Turn On Speed
The Leviton Decora Smart Z-Wave fan speed controller can be
setup to always turn on to a specific speed or to always return to
the last speed.
Fan Speed Level When Fan is Turned On:
1. To enter programming mode, hold the top of the paddle for
7 seconds. The status light will turn amber. Release and the
status light will blink.
2. Tap the top of the paddle 7 times. The status light will quickly
flash red/amber.
3. Use the fan speed bar to adjust the desired fan speed
or use O to always return to the last level.
4. Hold the top of the paddle to exit.
Quick Tips
If your controller is not performing as expected, visit
leviton.com/decorasmart or contact technical services.
• Fan turns on but does not run as fast as is should:
- Use the fan speed bar to select 100%.
- If the fan has a pull chain or similar speed control, ensure
it is at 100% and use only the Decora Smart fan speed
controller to set the fan's speed.
• Intermittent operation:
- Confirm the load does not exceed ratings.
- Confirm that a neutral is connected.
15
Page 16
Advanced Options
WEB VERSION
Leviton Decora Smart Devices are configurable over the
Z-Wave network. Compatible Z-Wave controllers can add support
for additional advanced options. Consult your Z-Wave controller
manufacturer for compatibility with advanced feature support.
Status LED Configuration
• Parameter No: 7, Length: 1 Byte
• Valid Values = 0 to 255 (default 255)
0 = LED O
254 = Status Mode
255 = Locater Mode
Preset Fan Speed Level
• Parameter No: 5, Length: 1 Byte
• Valid Values = 0 to 99 (default 0)
0 = Memory Dim - Last dim state
1 - 99 = Level
Your fan controller supports the following associations:
Group Number: 1
• Maximum Nodes: 5
• Name: Lifeline
• Profile: 0x0001
• Command Class: 0x5A01, 0x2603, Ox8703
Additional Supported
Z-Wave Classes
In addition to the standard Z-Wave Commands, your fan controller
supports:
Z-WAVE PLUS INFO
ASSOCIATION
ASSOCIATION GRP INFO
S2 SECURITY
S0 SECURITY
VERSION
MANUFACTURER SPECIFIC
CONFIGURATION
DEVICE RESET LOCALLY
POWERLEVEL
SWITCH MULTILEVEL
BASIC
SCENE ACTUATOR CONF
SCENE ACTIVATION
TRANSPORT SERVICE
FIRMWARE UPDATE MD
SUPERVISION
INDICATOR
MULTI CHANNEL ASSOCIATION
17
Page 18
Safety First
WEB VERSION
WARNING:TO AVOID FIRE, PERSONAL INJURY OR DEATH DO NOT USE
for the control of high power heating appliances such as por table heaters.
There can be unexpected consequences if not used with care. For example,
an empty coee pot can be remotely turned on. If that should happen,
your coee pot could be damaged from overheating. If an electric heater
is turned on by remote control while clothing is draped over it, a fire could
result. This module will not control lighting that is used with electronic
low-voltage and high frequency power supply transformers, nor high
pressure discharge lamps (HID lighting). This includes mercury-vapor,
sodium vapor and metal halide lamps.
WARNINGS:
• This product is to be installed and/or used in accordance with electrical
odes and regulations.
c
• Indoor use only.
• If you are unsure about any part of these instructions, consult an
ctrician.
ele
• Turn o power at the circuit breaker when servicing.
• Save this instruction sheet. It contains important technical data along
ith testing and troubleshooting information which will be useful after
w
installation is complete.
ADDITIONAL RATINGS:
• Purpose of control: Operating Control
• Action Control Type: 1
• Pollution Degree: 2
• Impulse Voltage: 2500V
18
Page 19
Limited 2 Year Warranty
WEB VERSION
For Levit on’s limited pr oduct warra nty, go to www.leviton.com. For a printed cop y of the warrant y,
call 1-800-824-30 05.
FOR CANADA ONLY
For warra nty informa tion and/or produ ct returns, r esidents of C anada should c ontact Levi ton in writin g at
Leviton M anufactur ing of Canada ULC t o the attent ion of the Qual ity Assur ance Depar tment, 165 Hymu s
Blvd, Poi nte-Claire (Q uebec), Canada H9 R 1E9 or by telephone a t 1-800-405- 5320.
FCC COMPLI ANCE STATEMENT
The encl osed device c omplies wi th Part 15 of the FC C Rules. Opera tion is subje ct to the follo wing
two con ditions: (i .) This device may no t cause harm ful interfer ence (ii.) This de vice must acc ept any
interference received, including interference that may cause undesired operation. Any changes
or modifi cations no t expressly ap proved by Levito n could void th e user’s auth ority to ope rate this
equipm ent. This equ ipment has be en tested and fo und to comply wi th the limi ts for a Class B di gital
device, p ursuant to par t 15 of the FCC Rule s. These limi ts are design ed to provide rea sonable prot ection
agains t harmful inte rference in a re sidential i nstallat ion. This equ ipment genera tes uses and ca n radiate
radio fre quency ene rgy and, if not in stalled an d used in accor dance with t he instruc tions, may c ause
harmfu l interferen ce to radio comm unicatio ns. However, there i s no guarantee t hat interfe rence will no t
occur in a p articul ar install ation. If th is equipment d oes cause ha rmful inter ference to radi o or televisio n
recept ion, which ca n be determin ed by turning t he equipment o and on, the use r is encourage d to try to
correc t the inter ference by one or m ore of the foll owing measur es:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
FCC CAUTIO N
Any chan ges or modific ations not exp ressly appro ved by Leviton Ma nufacturi ng Co., Inc., coul d void the
user’s a uthorit y to operate the e quipment.
FCC SUPPLIER’S DECLARATION OF CONFORMITY:
Model ZW4SF – Fan S peed Contro ller is manufa ctured by Levi ton Manufact uring Co., Inc. 201 N. S ervice
Road, Melv ille, NY 11747. w ww.leviton .com This devi ce complies w ith part 15 of t he FCC Rules. Ope ration
is subje ct to the follo wing two con ditions: (1) This de vice may not ca use harmful i nterferenc e, and (2) this
device must accept any interference received, including interference that may cause undesired operation.
IC S TATEM ENT
This dev ice complie s with Indus try Canada l icense-e xempt RSS stan dard(s). Operation i s subject to t he
follow ing two condi tions: (1) this dev ice may not caus e interferen ce, and (2) this devi ce must accep t any
interf erence, inclu ding interf erence that ma y cause undes ired operat ion of the devi ce.
RF EXPOSURE AND CO-LOCATION:
To comply wit h FCC OET Bullet in 65 and ISED RF ex posure limi ts for general p opulation a nd uncontro lled
exposu re, this devic e shall be inst alled and op erated with a m inimum dist ance of 7.9 inches (20 cm)
betwe en the radiato r and your body. Al so, must not be c o-located o r operated in co njunctio n with any
other an tenna or tran smitter.
Copyright and Trademark Information
The Leviton logo, Decora Smart and Decora are registered trademarks of Leviton Manufacturing Co., Inc.
in at least the United States, Canada and Mexico. Z-Wave and Z-Wave Plus are registered trademarks of
Silicon Labs and its subsidiaries in the U.S., Mexico, Argentina, Brazil and other countries. Use herein of
other third party trademarks, service marks, trade names, brand names and/or product names are for
informational purposes only, are/may be the trademarks of their respective owners; such use is not
meant to imply affiliation, sponsorship, or endorsement. No part of this document may be reproduced,
transmitted or transcribed without the express written permission of Leviton Manufacturing Co., Inc.
Copyright 2020 Leviton Mfg. Co., Inc.
Page 20
If you need help...
WEB VERSION
CALL
1-800-824-3005 (USA)
1-800-405-5320 (Canada)
ONLINE
decorasmartsupport.leviton.com
CHAT
www.leviton.com/contactus
EMAIL
dssupport@leviton.com
Leviton Manufacturing Co., Inc.
201 North Service Road, Melville, NY 11747
Tel ephon e: 1-800-82 4 -3005