Leviton VZI06-1L User Manual

Page 1
Single Pole (One location) or 3-Way (Multi-location)
ONOFF
ONOFF
ONOFF ONOFF
ONOFF
ONOFF
ONOFFONOFF
ONOFF
ONOFF ONOFF
ONOFF
BK
YL/RD
RD
Terminal
Screw marked
Black (BK)
Terminal
Screw marked
Red (RD)
Terminal
Screw marked
Yellow/Red
(YL/RD)
Terminal Label: Use Terminal for 3-Way or More Applications Only. For Single-Pole Applications, Do Not Remove This Label.
4
3
2
1
Cut
(if necessary)
Cat. No. VZIØ6-1L, 600W (Lighted)
DI-000-VZI06-02A
WARNINGS AND CAUTIONS:
•To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are unsure about any part of these instructions, consult a qualified electrician.
•To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a transformer­operated appliance.
• Use with incandescent or 120V halogen fixtures only.
•Vizia™ dimmers are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia™ remotes for multi-location dimming.
• Use only one (1) Vizia™ dimmer in a multi-location circuit with up to 9 coordinating remotes without LEDs or up to 4 matching remotes with LEDs. The remote(s) will turn the light on at the brightness level selected at the dimmer.
Tools needed to install your Dimmer:
Slotted/Phillips Screwdriver Electrical Tape Pliers Pencil Cutters Ruler
Changing the color of your Dimmer:
Your Dimmer may include three color options. The Dimmer ships with the White frame attached. To change color of frame, proceed as follows:
Push in side at tab to release
Line up tabs and press in side to attach
Installing Dimmer by itself or with other devices:
If installing Dimmer in a single device application, proceed with the INSTALLING YOUR DIMMER section. If installing Dimmer in a multi-device application, proceed as follows:
MULTI-DEVICE APPLICATION:
In multi-dimmer installations, the reduction of the dimmer’s capacity is required. Refer to the chart for maximum load per dimmer.
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE
Cat. No. Single Two Devices 2 Devices
VZI
Ø
6 600W 500W 400W
More than
INSTALLING YOUR DIMMER
NOTE: Use check boxes when Steps are completed.
Step 1
WARNING: TO AVOID FIRE, SHOCK, OR DEATH;
TURN OFF POWER at circuit breaker or fuse and test
that power is off before wiring!
Step 2
Identifying your wiring application (most common):
NOTE: If the wiring in the wall box does not resemble
any of these configurations, consult a qualified electrician.
1
3 4
Single-Pole
1. Line (Hot)
2. Neutral
3. Ground
4. Load
IMPORTANT:
terminals from the old switch being removed will usually be a different color (Black) or labeled Common. Tag that wire with electrical tape and identify as the common (Line or Load) in both the dimmer wall box and remote wall box.
For 3-Way applications, note that one of the screw
2
1
3 4 5
3-Way
1. Line or Load
instruction below)
2. Neutral
3. Ground
4. First Traveler – note color
5. Second Traveler – note color NOTE: For matching remote w/LEDs
installation, the First Traveler becomes Line Hot.
2
(See important
INSTALLATION INSTRUCTIONS
Step 3
Side Wire Connection
Side wire terminals accept #14 AWG
• Make sure that the ends of the wires from the wall box are
• Remove insulation from each wire in the wall box as shown.
For Single-Pole Application, go to Step 4a.
For 3-Way Coordinating Remote (no LEDs) Application, go
For 3-Way Matching Remote (with LEDs) Application, go to
Step 4a
Preparing and connecting wires:
This dimmer can be wired using side wire terminal screws or through backwire openings. Choose appropriate wire stripping specifications accordingly.
solid copper wire only.
straight (cut if necessary).
to Step 4b.
Step 4c.
Single-Pole Wiring Application:
Incandescent Dimmer
120VAC, 60Hz
WARNINGS AND CAUTIONS:
• Dimmer may not operate with dioded lamps (Sylvania Designer 16™ or Philips PAR-16™).
•Total minimum load must exceed 40W.
• Dimmer may feel warm to the touch during normal operation.
• Recommended minimum wall box depth is 2-1/2".
• Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.
• Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
• Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.
Strip Gage (measure bare
5/8"
(1.6 cm)
Back Wire (either hole may be used)
Back wire openings use #14-12 AWG
wire here or use gage on back of the dimmer)
solid copper wire only.
Step 4a cont’d
Dimmer
BK
Green
Black
RD
Load
White
Ground
YL/RD
Use Terminal for 3-Way or More Applications Only. For Single-Pole Applications, Do Not Remove This Label.
WIRING DIMMER: Connect wires per WIRING DIAGRAM as follows:
Green or bare copper wire in wall box to Green terminal screw.
Line Hot wall box wire to terminal screw marked "BK".
Load wall box wire to terminal screw marked "RD".
Dimmer terminal screw marked "YL/RD" should have Red
insulation label affixed. NOTE: If insulating label is not affixed to terminal screw marked
"YL/RD", use electrical tape to cover.
• Proceed to Step 5.
Step 4b
3-Way Wiring with Coordinating Dimming or Switching Remote (no LEDs)
(Coordinating Dimming Remote Depicted)
Coordinating Remote
BK
1
3
RD
4
YL/RD
5
2
Terminal
Screw marked
Black (BK)
Terminal
Screw marked
Yellow/Red
(YL/RD)
Hot (Black)
Neutral (White)
Dimmer
BK
YL/RD
Screw marked
Line
120VAC, 60Hz
1
3 4
RD
5
Terminal Red (RD)
Step 4b cont’d
Coordinating Remote (no LEDs)
Do not use for
Load
Black
White
incandescent
applications.
WH
RD
BK
Green Ground
YL/RD
WIRING DIMMER: Connect wires per WIRING DIAGRAM as follows:
NOTE: When using the coordinating remote without LEDs, the dimmer
can be installed on either the Line or Load side of the 3-way circuit. NOTE: Maximum wire length from dimmer to all installed remotes
cannot exceed 300 ft.
Green or bare copper wire in wall box to Green terminal screw.
Line Hot (common) wall box wire identified (tagged) when
removing old switch to terminal screw marked “BK”.
First Traveler wall box wire to terminal screw marked “RD” (note wire color). This traveler from the dimmer must go to the
terminal screw on the remote marked “RD”.
Remove Red insulating label from terminal screw marked “YL/RD”.
Second Traveler wall box wire to terminal screw marked “YL/RD” (note wire color). This traveler from the dimmer must go to the
terminal screw on the remote marked “YL/RD”.
WIRING COORDINATING REMOTE: Connect wires per WIRING DIAGRAM as follows:
NOTE: Maximum wire length from dimmer to last remote is 300ft.
2
Green or bare copper wire in wall box to Green terminal screw.
Load wall box wire identified (tagged) when removing old switch
to terminal screw marked “BK”.
First Traveler wall box wire (note color as above) to terminal screw marked “RD”. This traveler from the remote must go to the terminal screw on the dimmer marked “RD”.
Second Traveler wall box wire (note color as above) to terminal screw marked “YL/RD”. This traveler from the remote must go to the terminal screw on the dimmer marked “YL/RD”.
Remote terminal screw marked "WH" should have White insulationlabel affixed.
NOTE: If insulating label is not affixed to terminal screw marked "WH", use electrical tape to cover.
• Proceed to Step 5.
Dimmer
RD
BK
YL/RD
Hot (Black)
Green Ground
120VAC, 60Hz
Neutral (White)
Line
Page 2
Step 4c
120VAC, 60Hz
3-Way Wiring with Matching Remote (w/LEDs) Application:
Terminal
Black (BK)
Terminal
Yellow/Red
(YL/RD)
Dimmer
Dimmer
BK
Green
Ground
YL/RD
Matching Dimmer Remote
2
WH
BK
1
4
3
RD
YL/RD
5
Matching Dimmer
Remote (with LEDs)
Hot (Black)
Line
Neutral (White)
WH
BK
Green
Ground
YL/RD
Additional Neutral Wire
Screw marked
Screw marked
RD
K
B
RD
YL/RD
Terminal
Screw marked
Red (RD)
Step 5
4
2
3
1
5
Black
White
NOTE: Dress wires with a bend as shown in diagram in order to
relieve stress when mounting device.
Load
NOTE: The dimmer must be installed in a wall box that has a Load
connection. The matching remote must be installed in a wall box with a Line Hot connection and a Neutral connection. A Neutral wire to the matching remote needs to be added as shown.
If you are unsure about any part of these instructions, consult a qualified electrician.
NOTE: Maximum wire length from dimmer to all installed remotes cannotexceed 300 ft.
WIRING MATCHING REMOTE (wall box with Line Hot connection):
Connect wires per WIRING DIAGRAM as follows:
Green or bare copper wire in wall box to Green terminal screw.
Line Hot (common) wall box wire identified (tagged) when
removing old switch and First Traveler to dimmer terminal screw
Step 6
marked "BK".
Second Traveler wall box wire from dimmer to remote terminal screw marked "YL/RD" (note wire color). This traveler from the remote must go to the terminal screw on the dimmer marked "YL/RD".
Line Neutral wall box to remote terminal screw marked "WH".
WIRING DIMMER (wall box with Load connection): Connect wires per WIRING DIAGRAM as follows:
Green or bare copper wire in wall box to Green terminal screw.
Load wall box wire identified (tagged) when removing old switch
to dimmer terminal screw marked "RD".
First Traveler Line Hot to dimmer terminal screw marked "BK".
Remove Red insulating label from terminal screw marked
Step 7
"YL/RD".
Second Traveler wall box wire (note color as above) to dimmer terminal screw marked "YL/RD". This traveler from the dimmer must go to the terminal screw on the remote marked "YL/RD".
• Proceed to Step 5.
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years.
Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
Testing your Dimmer prior to mounting in wall box:
Position all wires to provide room
in outlet wall box for device.
Ensure that the word "TOP" is
facing up on device strap.
Partially screw in mounting screws
in wall box mounting holes.
• Restore power at circuit breaker or fuse.
Press pad until locator light is OFF.
Lights should turn ON. If lights do not turn ON, press the upper half of DIM/ BRIGHT bar until the lights brighten.
If lights still do not turn ON, refer to the TROUBLESHOOTING section.
Dimmer Mounting:
TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.
Installation may now be completed by tightening mounting screws into wall box. Attach wallplate.
Restore Power: Restore power at circuit breaker or
fuse. Installation is complete.
OPERATION
NOTE: The locator light will illuminate when the load is in the OFF
position to facilitate access in the dark. NOTE: If using the dimmer in a 3-way application, the lights will
turn ON at brightness set on dimmer's DIM/BRIGHT bar. The lighting can be controlled from either the dimmer or the remote location.
LED
Brightness
Display
DIM/BRIGHT
Push Pad (Default settings) Turn ON from OFF position:
Tap – Lights turn ON to preset level. Press and Hold – Lights turn ON to full bright.
Bar
Turn OFF from ON position:
Tap – Lights turn OFF. Press and Hold until lights DIM to lowest level and LED in LED Brightness Display starts to blink – Lights remain ON for 10 seconds and then turn OFF.
DIM/BRIGHT Bar BRIGHTEN:
Press upper half of DIM/BRIGHT Bar – Lights brighten to desired level.
DIM:
Press lower half of DIM/BRIGHT Bar – Lights dim to desired level.
Push
Pad
Air-Gap Switch: On the dimmer only,
engage the air-gap switch by gently pulling the bottom of the push pad until it lifts completely out of the frame and a click is
Locator
Light
If you continue to hold the lower half of the DIM/BRIGHT Bar, the lights will DIM to minimum level and then turn OFF. NOTE: When lights are OFF you can change the light level that the lights will turn ON to using the DIM/BRIGHT Bar.
If there is a power outage, when the power is restored the lights will return to the last setting before the power interruption.
heard and all LED’s are OFF (refer to Figure). This will cut power to the fixture to replace the bulb. After servicing is complete, push the push pad back for normal operation.
Cleaning: Clean with a damp cloth. DO NOT use chemical cleaners.
Gently lift bottom
of push pad out
ADVANCED PROGRAMMING FEATURES
Mode 1 – Set Minimum Brightness: Set the minimum brightness
level that the lights can dim to prior to turning full OFF. Mode 2 – Set Dim-Lock: Set the brightness level that the lights will
turn on to regardless of the previous light level at which they were turned OFF.
Mode 3 – Set Fade Rate: Set the amount of time (in seconds) that the lights will have to turn ON or OFF. Fade rates can be set to one of 7 different settings.
Advanced Features Summary
Mode Description Range Default
1 Set Min. Brightness 1-50% 25% 2 Set Dim-Lock Level 0-100%, 0=no lock 0 3 Select Fade Rate 1, 2, 3, 4, 5, 6 or 7 Preset #1
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
To Program:
NOTE: Have a flashlight handy if
this dimmer controls the only light source in the room.
1. On the dimmer only, engage the
air-gap switch by gently pulling the bottom of the push pad until it lifts completely out of the frame and a click is heard and all LED’s are OFF.
2. Press push pad back into frame
and hold push pad for 7 seconds until the locator light and the top LED (LED 1) starts blinking.
3. Upon releasing the push pad, the locator light will continue to
blink once per second indicating the dimmer is in Mode 1, Set Minimum Brightness mode. To change the current Minimum Brightness level from 1-50%, use the DIM/BRIGHT Bar. This setting will automatically be saved.
4. Tap the push pad to change to Mode 2, Set Dim-Lock Level
mode. The locator light will blink twice per second. To change the current Set Dim-Lock level from 1-100%, use the DIM/ BRIGHT Bar. If this feature is not desired, press and hold the lower half of the DIM/BRIGHT Bar until no LED is lit. This setting will automatically be saved.
5. Tap the push pad to change to Mode 3, Set Fade Rate mode.
The locator light will blink 3 times per second. To change the current Fade Rate, use the DIM/BRIGHT Bar to move the LED to the desired preset level. This setting will automatically be saved by tapping the push pad to exit programming mode.
The LED Brightness Display is separated into 7 segments. Each LED represents a preset level with LED 1 (Preset 1) located at the top and LED 7 (Preset 7) located at the bottom. Refer to chart for settings and defaults.
NOTE: The dimmer will exit program mode after 3 minutes of inactivity.
Fade Rate Presets
Preset LED
1* 1 Approx. 1.5s from full off Approx. 3s from full on
*** 2 No Fade No Fade
2 3 3 No Fade Approx. 3s from full on 4 4 Approx. 0.5s from full off Approx. 3s from full on 5 5 Approx. 0.5s from full off Approx. 1.5s from full on 6 6 Approx. 1.5s from full off Approx. 5s from full on 7 7 Approx. 1.5s from full off Approx. 10s from full on
** Fade On Fade Off
* default ** LED #1 is located at the top *** The press and hold feature for the 10 second delayed off is
disabled in this mode.
1 2
LED
3
Brightness
4 5
Display
6 7
TROUBLESHOOTING
Lights Flickering
- Lamp has a bad connection.
- Wires not secured firmly under terminal screws of dimmer and/or remote.
Light does not turn ON and Locator LED does not
turn ON
- Circuit breaker or fuse has tripped.
- Lamp is burned out.
- Lamp Neutral connection is not wired.
Intermittent dimmer operation
- Minimum load is under 40W.
Remote does not operate lights
- Ensure that total wire length does not exceed 300 ft.
For additional information, contact Leviton’s Techline at website at
Copyright
1-800-824-3005
www.leviton.com
U.S. & Foreign Patents Pending
©
2006 Leviton Manufacturing Co., Inc.
or visit Leviton's
All Rights Including Trade Dress Rights Reserved
FCC COMPLIANCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving Antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/tv technician for help.
DI-000-VZI06-02A
Loading...