Leviton Vizia RZI6-1L User Manual

Page 1
Single Pole (One location) or 3-Way (Multi-location)
Compatible with enabled products!
TM
Hot (Black)
Neutral (White)
Load
Dimmer
BK
Black
White
RD
Green Ground
Line
120VAC, 60Hz
YL/RD
Use terminal for 3-way or more applications only. For single pole applications, do not remove this label.
BK
YL/RD
RD
BK
YL/RD
RD
4
3
2
1
5
Cordinating Remote
2
4
3
5
1
Dimmer
Terminal
Screw marked
Black (BK)
Terminal
Screw marked
Red (RD)
Terminal
Screw marked
Yellow/Red
(YL/RD)
Hot (Black)
Neutral (White)
Load
Dimmer
Coordinating Remote (no LEDS)
YL/RD
YL/RD
RD
WH
RD
BK
BK
Black
Do not use for
incandescent
applications.
White
Line
120VAC, 60Hz
Green Ground
Green Ground
BK
YL/RD
RD
Terminal Label: Use terminal for 3-way or more applications only. For single pole applications do not remove this label.
4
3
2
1
Terminal
Screw marked
Black (BK)
Terminal
Screw marked
Yellow/Red
(YL/RD)
Terminal
Screw marked
Red (RD)
2
4
3
1
2
4
1
5
3
Bl
Scene Capable Incandescent Dimmer
Cat. No. RZIØ6-1L, 600W (Lighted)
DI-000-RZI06-00C
INSTALLATION INSTRUCTIONS
WARNINGS AND CAUTIONS:
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are unsure about any part of these instructions, consult a qualified electrician.
• To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a transformer-operated appliance.
• Use with incandescent or 120V halogen fixtures only.
Vizia™ RF dimmers are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia™ or Vizia™ RF remotes for multi-location dimming.
• Use only one (1) Vizia™ RF dimmer in a multi-location circuit with up to 9 Vizia™ coordinating remotes without LEDs or Vizia™ RF controllers. The remote(s) will turn the light on at the brightness level selected at the dimmer.
120VAC, 60Hz
WARNINGS AND CAUTIONS:
• Dimmer may not operate with dioded lamps (Sylvania Designer 16™ or Philips PAR-16™).
• Total minimum load must exceed 40W.
• Dimmer may feel warm to the touch during normal operation.
• Recommended minimum wall box depth is 2-1/2”.
• Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.
• Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
• Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.
INTRODUCTION
Leviton’s ViziaTM RF components are designed to communicate with each other via Radio Frequency (RF) to provide remote control of your lighting. Using RF technology allows Leviton to provide the greatest signal integrity possible. Each module in Leviton’s ViziaTM RF component line is a Z-WaveTM enabled device. In a Z-WaveTM network, each device is designed to act as a router. These routers will re-transmit the RF signal from one device to another until the intended device is reached. This ensures that the signal is received by its intended device by routing the signal around obstacles and radio dead spots. The Scene Capable Plug-in Lamp Dimming Module is compatible with any Z-Wave™ enabled network, regardless of the manufacturer and can also be used with other devices displaying the Z-Wave™ logo.
CAUTION:
Remember to exercise good common sense when using the Timer features of your remote, especially when scheduling unattended devices. There can be some unexpected consequences if not used with care. For example, an empty coffee pot can be remotely turned on. If that should happen, your coffee pot could be damaged from overheating. If an electric heater is turned on by remote control while clothing is draped over it, a fire could result. DO NOT USE the remote for the control of high power heating appliances such as portable heaters. This device will not control lighting that is used with electronic low­voltage and high frequency power supply transformers, nor high pressure discharge lamps (HID lighting). This includes mercury­vapor, sodium vapor and metal halide lamps.
FEATURES
• Soft fade ON/OFF
• Scene capable
• ON/OFF LED and Brightness level LED
• Two way communication
• RF reliability
• Ease of installation – No new wiring
• Compatible with other Z-Wave™ enabled devices
• No Neutral wire required
Tools needed to install your Dimmer:
Slotted/Phillips Screwdriver Electrical Tape
Pliers Pencil
Cutters Ruler
Changing the color of your Dimmer:
Your Dimmer may include three color options. The Dimmer ships with the White frame attached. To change color of frame, proceed as follows:
Step 2
Identifying your wiring application (most common):
NOTE: If the wiring in the wall box does not resemble
any of these configurations, consult a qualified
Step 4a
Single-Pole Wiring Application:
Step 4b cont’d
electrician.
Single-Pole
Push in
side at tab
to release
Line up tabs and press in
side to attach
1. Line (Hot)
2. Neutral
3.
4.
Ground Load
Installing Dimmer by itself or with other devices:
If installing Dimmer in a single device application, proceed with the
INSTALLING YOUR DIMMER
multi-device application, proceed as follows:
MULTI-DEVICE APPLICATION:
In multi-dimmer installations, the reduction of the dimmer’s capacity is required. Refer to the chart for maximum load per dimmer.
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE
More than
Cat. No. Single Two Devices 2 Devices
RZIØ6 600W 500W 400W
section. If installing Dimmer in a
IMPORTANT: For 3-Way applications, note that one of the screw terminals from the old switch being removed will usually be a different color (Black) or labeled Common. Tag that wire with electrical tape and identify as the common (Line or Load) in both the dimmer wall box and remote wall box.
Step 3
Preparing and connecting wires:
This dimmer can be wired using side wire terminal screws or through backwire openings. Choose appropriate wire stripping specifications accordingly.
5/8”
(1.6 cm)
cut
(if necessary)
INSTALLING YOUR DIMMER
NOTE: Use check boxes when Steps are completed.
Step 1
WARNING: TO AVOID FIRE, SHOCK, OR DEATH;
TURN OFF POWER
that power is off before wiring!
at circuit breaker or fuse and test
Side Wire Connection
Side wire terminals accept #14 AWG solid copper wire only.
Back Wire (either hole may be used)
Back wire openings use #14-12 AWG solid copper wire only.
• Make sure that the ends of the wires from the wall box are
straight (cut if necessary)
.
• Remove insulation from each wire in the wall box as shown.
For Single-Pole Application, go to Step 4a.
3-Way
1. Line or Load (See important instruction below)
Neutral
2.
3. Ground
4. First Traveler
– note color
5. Second Traveler – note color
Strip Gage (measure bare wire here or use gage on back of the dimmer)
WIRING DIMMER: Connect wires per WIRING DIAGRAM as follows:
Green or bare copper wire in wall box to Green terminal screw.
Line Hot wall box wire to terminal screw marked “BK”.
Load wall box wire to terminal screw marked “RD”.
Dimmer terminal screw marked “YL/RD” should have Red
insulation label affixed.
NOTE:
“YL/RD”, use electrical tape to cover.
• Proceed to Step 5.
Step 4b
If insulating label is not affixed to terminal screw marked
3-Way Wiring with Coordinating Dimming or Switching Remote (no LEDs) Application:
(Coordinating Dimming Remote Depicted)
WIRING DIMMER: Connect wires per WIRING DIAGRAM as follows:
NOTE: When using the coordinating remote without LEDs, the
dimmer can be installed on either the Line or Load side of the 3-way circuit.
NOTE: Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.
Green or bare copper wire in wall box to Green terminal screw.
Line Hot (common) wall box wire identified (tagged) when
removing old switch to terminal screw marked “BK”. First Traveler wall box wire to terminal screw marked “RD”
• (note wire color). This traveler from the dimmer must go to
the terminal screw on the remote marked “RD”.
Remove Red insulating label from terminal screw marked “YL/RD”.
Second Traveler wall box wire to terminal screw marked “YL/RD” (note wire color). This traveler from the dimmer must go to the terminal screw on the remote marked “YL/RD”.
WIRING COORDINATING REMOTE: Connect wires per WIRING DIAGRAM as follows:
NOTE: Maximum wire length from dimmer to last remote is 300ft.
Green or bare copper wire in wall box to Green terminal screw.
Load wall box wire identified (tagged) when removing old
switch to terminal screw marked “BK”.
First Traveler wall box wire (note color as above) to terminal screw marked “RD”. This traveler from the remote must go to the terminal screw on the dimmer marked “RD”.
Second Traveler wall box wire (note color as above) to terminal screw marked “YL/RD”. This traveler from the remote must go to the terminal screw on the dimmer marked “YL/RD”.
Remote terminal screw marked “WH” should have White insulation label affixed.
NOTE: If insulating label is not affixed to terminal screw
marked “WH”, use electrical tape to cover.
• Proceed to Step 5.
For 3-Way Coordinating Remote (no LEDs) Application, go to Step 4b.
Page 2
NOTE: Remote must be in close proximity to dimmer when including in the network.
RZCPG
Programmer/Comtroller
1
ON
2
ON
3
ON
4
ON
OFF
OFF
OFF
OFF
1
2
3
4
5
6
7
LED Brightness Display
Step 5
Testing your Dimmer prior to mounting in wall box:
Position all wires to provide room
in outlet wall box for device.
Ensure that the word “TOP” is facing up on device strap.
Partially screw in mounting screws in wall box mounting holes.
NOTE: Dress wires with a bend as shown in diagram in order to relieve stress when mounting device.
• Restore power at circuit breaker or fuse.
Press pad until locator light is OFF. Lights should turn ON. If lights do not turn ON, press the upper half of DIM/
D) The Primary Programmer/Controller will
assign a node ID number (Name) for this module.
NOTE: This ID number (Name) will be
stored in the controller library to be used for future reference.
NOTE: You may name or edit the node
of this device at this time.
E) The dimmer is now installed in the
network.
NOTE: If a dimmer has been successfully
Included in the network and the user tries to Include it again without first excluding it from the network, the module will retain the first node ID it had received and ignore the second.
Factory Default:
If your dimmer is not responding, or you are unable to control it after you have tried to Include/Exclude it multiple times, it may be necessary to reset the dimmer to its original factory settings. To accomplish this, proceed as follows:
• On the dimmer, engage he air-gap switch
section) and wait 5 seconds. Press push pad back into frame and
(refer to Operation
hold push pad until the locator LED flashes Amber and turns solid Red. The dimmer is now reset. Once the dimmer is reset, it will be necessary to Re-Include it to a network before it can be used.
CAUTION: SETTING A DEVICE TO A FACTORY DEFAULT
DOES NOT EXCLUDE THAT DEVICE FROM A NETWORK. THE EXCLUSION PROCEDURE MUST STILL BE FOLLOWED TO REMOVE THE DEVICE FROM THE PRIMARY CONTROLLER’S INFORMATION TABLE. FAILURE TO DO SO MAY RESULT IN A SYSTEM THAT IS SLOW TO RESPOND, OR MAY FAIL TO RESPOND TO SOME DEVICES.
Step 8
Dimmer Mounting:
TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.
BRIGHT bar until the lights brighten.
If lights still do not turn ON, refer to
the TROUBLESHOOTING section.
Installation may now be completed by tightening mounting screws into wall box. Attach wallplate.
Step 6
NOTES:
• If using a non-Leviton
Including Scene Capable Dimmer into Z-Wave™ Network:
Programmer/Controller
Cat. No. RZCPG
Programmer/Controller, refer to the Programmer/Controller
Step 7
Excluding Dimmer from Network:
instruction sheet for Including a device.
A) If using a Leviton Z-Wave™
Programmer/Controller, Cat. No. RZCPG, press the Menu button and scroll down to System Setup. Press the center button to select System Setup Menu. Press the
Menu Button
Center Button
center button to select Network.
B) While standing close to the
module (approx. 2-5 ft), press the center button to <Include> device in the network.
NOTE: Only one device may be included at a time. DO NOT
put multiple devices into the Inclusion mode at any time. While the Programmer/Controller is in the Inclusion mode and
C)
the Locator LED is ON on the dimmer, push the push pad to turn ON the dimmer. The Programmer/Controller will verify inclusion and the locator LED will turn OFF on the dimmer.
If the dimmer is flashing Amber while in the Inclusion mode,
the Programmer/Controller is still trying to communicate with the dimmer. Wait until the device stops flashing,then press push pad.
NOTE: If the locator LED on the dimmer turns solid Red while
including, there has been a communication error. Refer to Troubleshooting section.
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
NOTE: It is very important to accurately Exclude devices from the network when moving or removing a device from a Z-Wave™ network. This ensures that all information has been removed from your Primary Programmer/Controller’s information table and is not counted on to be a part of the mesh network.
A) If using a Leviton Z-Wave™ Programmer/Controller, Cat. No.
RZCPG, press the Menu button and scroll down to System Setup. Press the center button to select System Setup Menu. Press the center button to select Network.
B)
While standing close to the module, press the center button to <Exclude> device from the network.While the Programmer/ Controller is in the Exclusion mode and the locator LED is ON on the dimmer, press the push pad on the dimmer. The Programmer/ Controller will verify Exclusion and the locator LED will turn OFF on the dimmer.
If the dimmer is flashing Amber while in the Exlusion mode, the
Programmer/Controller is still trying to communicate with the dimmer. Wait until the device stops flashing, then press the push pad.
Protected under U.S. Patent Number 6,388,399 and patents pending and licensed under U.S. Patents Numbers 5,905,442, and 5,982,103
Step 9
OPERATION
NOTE: The locator light will illuminate when
the load is in the OFF position to facilitate access in the dark.
NOTE: If using the dimmer in a 3-way application, the lights will turn ON at brightness set on dimmer’s DIM/BRIGHT bar. The lighting can be controlled from either the dimmer or the remote location.
Push Pad (Default settings) Turn ON from OFF position:
Tap – Lights turn ON to preset level. Press and Hold – Lights turn ON to full bright.
Turn OFF from ON position:
Tap – Lights turn OFF.
DIM/BRIGHT Bar BRIGHTEN:
Press upper half of DIM/BRIGHT Bar – Lights brighten to desired level.
DIM:
Press lower half of DIM/BRIGHT Bar – Lights dim to desired level. If you continue to hold the lower half of the DIM/BRIGHT Bar, the lights will DIM to minimum level and then turn OFF. NOTE: When lights are OFF you can change the light level that the lights will turn ON to using the DIM/BRIGHT Bar.
If there is a power outage, when the power is restored the lights will return to the last setting before the power interruption.
Restore Power: Restore power at circuit breaker or
fuse. Installation is complete.
LED Brightness
Display
Push
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Pad
DIM/BRIGHT
Bar
Locator
Light
Air-Gap Switch: On the dimmer only,
engage the air-gap switch by gently pulling the bottom of the push pad until it lifts completely out of the frame and a click is heard and all LED’s are OFF (refer to Figure). This will cut power to the fixture to replace the bulb. After servicing is complete, push the push pad back for normal operation.
Cleaning: Clean with a damp cloth. DO NOT use chemical cleaners.
Gently lift bottom
of push pad out
ADVANCED PROGRAMMING FEATURES
Mode 1 – Set Minimum Brightness: Set the minimum brightness
level that the lights can dim to prior to turning full OFF.
Mode 2 – Set Dim-Lock: Set the brightness level that the lights will turn on to regardless of the previous light level at which they were turned OFF.
Mode 3 – Set Fade Rate: Set the amount of time (in seconds) that the lights will have to turn ON or OFF. Fade rates can be set to one of 7 different settings.
Advanced Features Summary
Mode Description Range Default
1 Set Min. Brightness 1-50% 25%
2 Set Dim-Lock Level 0-100%, 0=no lock 0
3 Select Fade Rate 1, 2, 3, 4, 5, 6 or 7 Preset #1
To Program:
NOTE: Have a flashlight handy if this dimmer
controls the only light source in the room.
1. On the dimmer only, engage the air-gap
switch by gently pulling the bottom of the push pad until it lifts completely out of the frame and a click is heard and all LED’s are OFF.
2. Press push pad back into frame and hold
push pad for 7 seconds until the locator light and the top LED (LED 1) starts blinking.
3. Upon releasing the push pad, the locator
light will continue to blink once per second indicating the dimmer is in Mode 1, Set Minimum Brightness mode. To change the current Minimum Brightness level from 1-50%, use the DIM/BRIGHT Bar. This setting will automatically be saved.
4. Tap the push pad to change to Mode 2, Set Dim-Lock Level mode. The
locator light will blink twice per second. To change the current Set Dim­Lock level from 1-100%, use the DIM/BRIGHT Bar. If this feature is not desired, press and hold the lower half of the DIM/BRIGHT Bar until no LED is lit. This setting will automatically be saved.
5. Tap the push pad to change to Mode 3, Set Fade Rate mode. The
locator light will blink 3 times per second. To change the current Fade Rate, use the DIM/BRIGHT Bar to move the LED to the desired preset level. This setting will automatically be saved by tapping the push pad to exit programming mode.
The LED Brightness Display is separated into 7 segments. Each LED represents a preset level with LED 1 (Preset 1) located at the top and LED 7 (Preset 7) located at the bottom. Refer to chart for settings and defaults.
NOTE: The dimmer will exit program mode after 3 minutes of in inactivity.
Fade Rate Presets
Preset LED** Fade On Fade Off
1* 1 Approx. 1.5s from full off Approx. 3s from full on 2*** 2 No Fade No Fade 3 3 No Fade Approx. 3s from full on 4 4 Approx. 0.5s from full off Approx. 3s from full on 5 5 Approx. 0.5s from full off Approx. 1.5s from full on 6 6 Approx. 1.5s from full off Approx. 5s from full on 7 7 Approx. 1.5s from full off Approx. 10s from full on
* default ** LED #1 is located at the top *** The press and hold feature for the 10 second delayed off
is disabled in this mode.
TROUBLESHOOTING
Lights Flickering
- Lamp has a bad connection.
- Wires not secured firmly under terminal screws of dimmer and/or remote.
- Local switch, ON
Light does not turn ON and Locator LED does not
turn ON
- Circuit breaker or fuse has tripped.
- Lamp is burned out.
- Lamp Neutral connection is not wired.
- Confirm that the device is being supplied from a 120V, 60Hz AC source ONLY.
- Confirm that unit is programmed properly. Repeat “TO INSTALL” section to verify that it has been included in the Z-Wave™ network.
Intermittent dimmer operation
- Minimum load is under 40W.
- Confirm that the Load being controlled does not exceed the 1000W dimmer limit.
Remote does not operate lights
- Ensure that total wire length does not exceed 300 ft.
For additional information, contact Leviton’s
Techline at 1-800-824-3005 or visit Leviton’s
website at www.ViziaRF.com
FCC COMPLIANCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving Antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/tv technician for help.
DI-000-RZI06-00C