Tools needed to install your Dimmer:
Slotted/Phillips Screwdriver Electrical Tape Pliers Pencil Cutters Ruler
Installing Dimmer by itself or with other devices:
If installing Dimmer in a single device application, proceed with the INSTALLING YOUR DIMMER section. If installing Dimmer in a multi­device application, proceed as follows:
MULTI-DEVICE APPLICATION
NOTE: 600W devices do not have break-off side sections. Derating is
still required in multi-gang installation (see chart). For 1000W devices: When ganging dimmers, the side sections of the
mounting strap must be removed. Use pliers to carefully bend side sections back and forth until they break off (see Figure). The side sections dissipate heat, so removing them requires a derating of the dimmer's capacity (see chart).
NOTE: You only need to remove side sections if installing with other dimmers or if it does not fit in wall box – not when installing with mechanical switches.
INSTALLING YOUR DIMMER
NOTE: Use check boxes when Steps are completed.
WARNING: To avoid fire, shock, or death; TURN OFF
POWER at circuit breaker or fuse and test that power is off
before wiring!
Removing existing switch: Remove existing
wallplate and switch mounting screws. Carefully pull switch from wall box. DO NOT remove wires attached to the switch at this time.
Identifying your wiring application (most common):
NOTE: If the wiring in the wall box does not resemble any of
these configurations, consult a qualified electrician.
Step 2
Preparing and connecting wires:
Step 4
Single-Pole Wiring Application (600W device depicted):
Step 1
Step 3
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFFONOFF
ONOFF
ONOFF
ONOFF
ONOFF
WARNINGS & CAUTIONS:
•To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are unsure about any part of these instructions, consult a qualified electrician.
•To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a transformer-operated appliance.
• Use with incandescent or 120V halogen fixtures only.
•Total minimum wattage must exceed 40W.
WARNINGS & CAUTIONS:
• Use only one (1) dimmer in a 3- or 4-way circuit. The switch(es) will turn the light on at the brightness level selected at the dimmer.
• Disconnect power at circuit breaker or fuse when servicing fixture.
• Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.
•Recommended to use with non-metallic wallplates.
Bend back and forth to remove side section
Remove all inner side sections
Do not remove outer side sections
• Make sure that the ends of the wires from the wall box are
straight (cut if necessary)
.
• Remove 5/8" (1.6 cm) of insulation from each wire in the wall box (shown).
For Single-Pole Application, go to Step 5a.
For 3-Way Application, go to Step 5b.
Cut
(if necessary)
More than
Cat. No. Single Two Devices 2 Devices
TGI
Ø
6-1L 600W 500W 400W
TGI1
Ø
-1L 1000W 800W 700W
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE
Step 5a
Black
Red
Neutral
Green
Ground
Red
This wire is used in 3-way installations only. For single pole installations, do not remove this insulating label.
4
3
1
2
Insert wires
straight then twist
clockwise
Electrical
Tape
2
4
3
1
2
4
1
5
3
3-Way
1. Line or Load
(See important
instruction below)
2. Neutral
3. Ground
4. First Traveler – note color
5. Second Traveler – note color
Single-Pole
1. Line (Hot)
2. Neutral
3. Ground
4. Load
IMPORTANT:
For 3-Way applications, note that one of the screw terminals from the old switch being removed will usually be a different color (Black) or labeled Common. Tag that wire with electrical tape and identify as the common (Line or Load) in both the dimmer wall box and 3-way wall box.
Strip Gage
(measure bare wire here)
5/8"
(1.6 cm)
Connect wires per WIRING DIAGRAM as follows:
Screw wire nuts on clockwise making sure no bare conductors show below the wire connectors. Secure each connector with electrical tape.
Green dimmer Ground lead to Green or bare copper wire in wall box.
Black dimmer lead to any wall box wire removed from old switch.
Red dimmer lead without insulating label to remaining wall box wire.
Remaining Red dimmer lead should have Red insulation label affixed. NOTE: If insulating label is not affixed to Red lead, use a small wire nut or electrical tape to cap off.
•Proceed to Step 6.
3-Way Wiring Application (600W device depicted):
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without
limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
Connect wires per WIRING DIAGRAM as follows:
Screw wire nuts on clockwise making sure no bare conductors show below the wire connectors. Secure each connector with electrical tape.
NOTE: Control can be installed on either the Load or Line side of the 3-way circuit.
Green dimmer Ground lead to Green or bare copper wire
in wall box.
Black dimmer lead to tagged (common) wall box wire identified when removing old switch.
Remove Red insulating label from Red lead.
Any Red dimmer lead to any of the remaining
wall box wires.
Remaining Red dimmer lead to remaining wall box wire.
Testing your Dimmer prior to completely mounting in wall box (1000W device depicted):
Dimmer Mounting (1000W device depicted):
TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.
Step 7
Restore Power: Restore power at circuit breaker or
fuse. Installation is complete.
OPERATION
NOTE: On the lighted models, indicator light will illuminate when
the dimmer is in the OFF position to facilitate access in the dark. NOTE: If using the dimmer in a 3-way application, the lights will
turn ON at brightness set on dimmer's touch pad. The lighting can be controlled from either the dimmer or the switch location.
TROUBLESHOOTING
• Lights Flickering
- Lamp has a bad connection.
- Lamp power is less than 40W.
- Wires not secured firmly with wire connectors.
• Light does not turn ON and ON/OFF LED does not turn ON
- Circuit breaker or fuse has tripped.
- Lamp is burned out.
- Lamp Neutral connection is not wired.
For non-standard wiring applications, refer
to Wire Nut and Conductor Size Chart
Step 5b
Hot (Black)
Neutral (White)
Load
Dimmer
3-Way Switch
Red
Black
Green
Ground
Green
Ground
Black
White
Red
Line
120VAC, 60Hz
Common Terminal
(Black Screw)
Step 6
Hot (Black)
Neutral (White)
Load
Black
Green
Ground
Black
White
Red
Line
120VAC, 60Hz
Red
Insulating
Label
Dimmer
Step 8
WIRE NUT / # OF CONDUCTOR
COMBINATION CHART
1- #12 w/ 1 to 3 #14, #16 or #18 2- #12 w/ 1 or 2 #16 or #18 1- #14 w/ 1 to 4 #16 or #18 2- #14 w/ 1 to 3 #16 or #18
Black
Red
Neutral
Green
Ground
Red
Tag
4
5
3
1
2
Step 5b cont'd
•Position all wires to provide room in wall box for device.
Partially secure device using long mounting screws provided.
• Restore power at circuit breaker or fuse.
•Move toggle handle up. Lights should turn ON. If lights do not turn ON, touch top touch pad to brighten the lights. Lights should brighten.
If lights still do not turn ON, refer to the TROUBLESHOOTING section.
ON/OFF:
Move toggle handle up – Lights will turn ON.
Move toggle handle down – Lights will turn OFF.
BRIGHTEN :
Touch top touch pad – Lights will BRIGHTEN.
DIM:
Touch bottom touch pad – Lights will DIM.
CLEANING:
To clean touch plate, wipe it with a clean damp cloth using clean water only, dry thoroughly.
Step 5a cont'd
Insert wires
straight then twist
clockwise
Electrical
Tape
PRODUCT INFORMATION
•For technical assistance, contact us at
1-800-824-3005
• Visit our website at
www.leviton.com
Touch Pad
Single-Pole Wiring Application (600W device depicted):
1000W device
depicted
NOTE: Dress wires with a bend as shown in diagram to relieve stress
when mounting device
• Installation may now be completed by firmly tightening mounting screws.
• Attach wallplate.