System Overview ..................................................................................................................... 5
Remember When … ....................................................................................................................................5
Welcome Back to Simplicity. ........................................................................................................................ 5
What experience is Prerequisite? ................................................................................................................ 5
What is needed? ..........................................................................................................................................5
What is not needed? ....................................................................................................................................6
Control Station Operation .......................................................................................................7
Play Mode ....................................................................................................................................................7
DMX Snapshot Record Mode ......................................................................................................................7
Record Example:..........................................................................................................................................8
Take control PCB .......................................................................................................................................10
2 Channel Analog Fader PCB ....................................................................................................................10
ANA-2-DMX Scene Processor PCB...........................................................................................................10
System Design Considerations ............................................................................................ 11
Place HHR or DMX-512 IN jacks near DMX stations.................................................................................11
Power Supply Requirements...................................................................................................................... 11
Current Calculation Examples:...................................................................................................................12
System Cable Requirements................................................................................................. 13
Cross Referenced Analog Compatible Cable Types: .................................................................................13
What is ground? .........................................................................................................................................14
Keep COM and GND separate. .................................................................................................................14
Make star or daisy chain connections. .......................................................................................................14
LIMITED TWO YEAR WARRANTY AND EXCLUSIONS ..............................................................38
Page 4 of 40
Leviton Remembrance Control Stations
Page 5
User Guide
SYSTEM OVERVIEW
Remember When …
Remember when anyone could add a house light channel or a submaster to a lighting control system by wiring a
slide pot to a diode and attaching it to which ever dimmers they wanted to control? Remember when control
stations could be set up as independents, or group them with masters all without having to have a lap top, memorize
DMX-512, know Windows 95 or battle the great configuration labyrinths envisioned by dyslexic software engineers?
Everything was modular and simple. There was not a central “brain” that required programming, and there was not
the hidden central processor costs and LAN limitations of most conventional architectural control systems.
Welcome Back to Simplicity.
This control system uses 3 small printed circuit board and 2 standard control protocols – DMX-512 and 0-10VDC as
tools to create complex configurations in the simplest and least expensive way.
The three PCB’s are:
• An on/off Take Control card
• A break-away, configurable, 0-10 VDC fader board.
• A 6 Channel 0-10VDC to DMX512 Scene Processor.
What experience is Prerequisite?
The only principles a designer needs to understand is:
• Take Control
• Master
• Slave
• Independent
• Snapshot DMX stream
• Pile-On (highest takes precedence)
Previous experience with 0-10VDC, diode patching and/or DMX-512 control protocols and control wiring is helpful,
but not essential.
What is needed?
• 0-10 VDC or DMX-512 Dimmers/Ballast’s
• A DMX-512 Control Console for developing Scenes (DMX stations only)
• A +12to +16 VDC Power Supply or Analog Stations (This power supply is not required when used in conjunction
with a DMX Station. See page 3 for current requirements)
• 10V/5VA bell transformer for DMX Stations (The DMX station will provide 150mA of +V to drive several
Analog Stations).
Leviton Remembrance Control Stations
Page 5 of 40
Page 6
User Guide
• Standard NEMA Gang Boxes
• Imagination
What is not needed?
• A PC, DOS, Windows. Configuration files, disks or download cables. Station thumbwheel settings, A central
processing cabinet. Lots of patience.
Page 6 of 40
Leviton Remembrance Control Stations
Page 7
CONTROL STATION OPERATION
Play Mode
ActionResult
• Press the ON/OFF (Panic) button toThe LED will light, indicating the
activate the station.station is active. An Entry or Panic
station will automatically activate a scene.
• Adjust Master Fader if applicable.The Master Fader Proportionally
controls all channel levels.
• Adjust Channel Fader if applicable.Channel Faders may control one
light, a group of lights, or an entire scene.
User Guide
• Press the ON/OFF (Panic) button toThe lights will fade out and the
turn off the lights.LED will turn off.
DMX Snapshot Record Mode
(For DMX control stations only)
ActionResult
• Insure JP1 Jumper is out onThe remove jumper on JP1 puts the
ANA2DMX ProcessorProcessor in DMX Snapshot mode.
• Insure Record Lock is off.Record Lock disables any attempt to
record scenes, D19 LED on
ANA2DMX Processor will be Orange if able
to record. Green if unable to record.
NOTE
Record Lock can be activated any of 3 ways:
1. Jumper JP1 shorted on 2 Channel Analog PCB on station.
2. Jumper JP2 shorted on ANA2DMX processor on station.
3. REC LOCK terminal on ANA2DMX processor on station driven with external +10VDC signal.
Leviton Remembrance Control Stations
Page 7 of 40
Page 8
User Guide
• Turn off all control stations.This insures only console levels will
be recorded.
• Bring up the desired scene or look onThis is the scene that will be
the main console recorded.
• Go to the DMX control station.This gets the station ready to be put
Slide Master Fader all the way up to full.in record mode.
Slide all the channel faders down to out.
• Push and hold the ON/OFF button when
turning the station “ON”
• Count to 5 (approximately 5 seconds)
(continue to hold the ON/OFF Button).mode. (LED on ANA2DMX PCB turns green).
• Slide the Channel Fader up to full whereThis snapshots the DMX-512 data
the scene is to be recorded. (continue tostream, saving the entire scene under
hold the ON/OFF Button).the proportional control of the
• Release the ON/OFF button.This exits Record Mode.
The Green LED will light.
This puts the Station into record
channel fader that slid to full. The LED on the
ANA2DMX Processor will blink red when it is
finished recording the scene.
Record Example:
To record scene into fader 1: (assuming REC LOCK is off)
Action
• Slide master fader to full, channel faders to out.
• Push & hold ON/OFF button when it goes from OFF to ON.
• Count out loud while continuing to hold ON/OFF button:
“One one thousand”
“Two one thousand”
“Three one thousand”
“Four one thousand”
“Five one thousand”
• Slide channel fader 1 to full.
• Release ON/OFF button.
Page 8 of 40
Leviton Remembrance Control Stations
Page 9
DMX Channel Mode
(for DMX control stations only)
ActionResult
• Install Jumper JP1 on ANA2DMX PCB.This puts processor in channel mode.
• Dial up the starting address onThis selects the DMX start address for
rotary Switches SW1, SW2, & SW3fader A1.
• For fader channel single patternFaders 1-6 will respond to DMX channels
• To replace the incoming DMX channelThe fader channels will replace the
levels with the fader levels, install JP5appropriate incoming DMX channel levels.
• For 4 channel operation install JP6 onThis puts the processor in 4 channel on
ANA2DMX Processor.wraparound mode.
• For 6 & 12 channel operation removeThis puts the processor in 6 channel on
JP6 on ANA2DMX Processor.wraparound mode.
Leviton Remembrance Control Stations
Page 9 of 40
Page 10
User Guide
COMPONENT FUNCTIONS
Take control PCB
The take control PCB has a single switch for ON/OFF operation. The take control PCB requires +12 to +16 Volts
DC 25mA connected across +V and common to operate. The PCB provides a regulated +10.6 VDC source when
the ON/OFF switch is activated (turned on) and O Volts when off.
Pressing the ON/OFF switch sends a +10VDC pulse out the T/C terminal on TB1 and down the T/C wire to reset
any other stations connected to the T/C wire and TB1. The Take Control line determines and connects the stations
you want to respond in a group. Not connecting the take control line makes the stations or groups respond
independently of each other.
When the ON led is lit, +10VDC is available on the VOUT terminal. The VOUT signal can be used to activate a
single analog channel, or when used with prep cable PRP-31316-02, it can be used to activate several channels at
once. The VOUT signal’s most common application is to implement Panic or Entry Stations. See the Wiring Diagrams
for Entry or Panic stations for more details.
2 Channel Analog Fader PCB
The Fader PCB is a breakable PCB array that can be easily be configured for 1-12 channels with or without a
master fader. The input/output bussed connector scheme of J1/P1 passes DC power, analog 0-10V levels, and
take control across the control station to the terminal block on the take control card, or to a header for the ANA-2DMX PCB. All 0-10V analog channels are buffered by an op-amp and diode blocked before leaving the PCB.
ANA-2-DMX Scene Processor PCB
The ANA-2-DMX PCB utilizes six 0-10 VDC analog control inputs to proportionally drive 6 DMX submaster scenes
that pile-onto each other and to the incoming DMX signal whether active or inactive. To record a scene, first bring
up the desired look on the console running to the DMX IN terminal. Next, slide the master to full and the channels
to off. Push and hold the ON/OFF button to ON for about 5 seconds on the station, putting the station in record
mode. Finally, slide the fader up to full for the channel you wish to record the scene into. As long as the record
lockout is not enabled, the scene will be saved onto that channel, and will proportionally fade relative to the slide
pot. For user convenience, the record lockout function which disables re-recording scenes is available on the DMX
terminal Block, as a jumper on the ANA-2-DMX PCB itself, and also as a jumper on the 2 channel fader PCB.
Record lock is perfect for setting up house light channels or looks, and then disabling the record function for
patrons. A DMX bypass relay is provided in the event of a power supply failure.
Page 10 of 40
Leviton Remembrance Control Stations
Page 11
User Guide
SYSTEM DESIGN CONSIDERATIONS
Place HHR or DMX-512 IN jacks near DMX stations
Place a Hand Held Remote Jack from the control console or a DMX-512 IN Jack where the console could be
plugged in near any station that will be used to snapshot scenes on a frequent basis. This way scenes can be
activated from the console in the same place they are to be recorded.
Power Supply Requirements
DMX Station Current Supply:
(+V/COM power supply source for a single station connected to a single 10V/5VA transformer)
Station TypeSupply CurrentCatalog No.# of Gang
4 Channel DMX Station150mA017-RMB81-104 4
6 Channel DMX Station150mA018-RMB81-106 5
12 Channel DMX Station100mA019-RMB81-112 8
12 Channel DMX station connected to qty 2-10V/5VA transformers. (transformers connected to separate
AC1/AC2 inputs)250ma.
NOTE
The +V/COM current through a DMX station should not exceed 750mA.
Analog Station Current Demands:
+V power supply requirements for a single station (+12 to +16 VDC)
Current demand calculation for qty 3, 6 channel stations connected in a group: T/C connected between stations,
therefore only one station can be on at a time.
All DMX-512 lines ............................................. Belden # 9829 cable
All Analog lines ................................................. Alpha # 1898/x C cable
1000 feet MAX!!Where x = the # of conductors
All AC1 and AC2 lines ....................................... 18 gauge 600V wire
Cross Referenced Analog Compatible Cable Types:
Belden 8489 (4 conductor)
Belden 8467 (7 conductor)
Belden 8466 (12 conductor)
Belden 8619 (19 conductor) (color code does not match)
National # NQ-418J (4 conductor)
User Guide
National # NQ-718J (7 conductor)
National # NQ-1018J (10 conductor)
National # NQ-1918J (19 conductor) (color code does not match)
Cable Derating Requirements:
Smaller gauges of multi conductor Alpha wire can be used for short runs with a minimum number of stations if
following list of the criteria is met:
Alpha #1896 (20 gauge conductors) can be used if:
1. The total analog cable length for the system does not exceed 300 Feet. AND
2. The maximum number of stations is 6.
Alpha #1774 thru #1180 (22 gauge conductors) can be used if:
1. The total analog cable length for the system does not exceed 100 Feet. AND
2. The maximum number of stations is 4.AND
3. The maximum number of channels is 6.
Leviton Remembrance Control Stations
Page 13 of 40
Page 14
User Guide
ELIMINATE GROUND LOOPS
What is ground?
This control system, like most other control systems requires a common reference for the electronics to function
properly. This reference is typically denoted as Common or Ground. Control voltages are measured with respect to
this ground reference, just like the height of a person would normally be measured with respect to the ground they
are standing on. Without a proper common reference, the electronics can not make accurate voltage measurements,
and therefore will not function correctly.
Keep COM and GND separate.
The ANA 2DMX PCB has 2 different control references. COM (Analog Common) and GND (Digital Ground). The
two are nearly the same, except COM is the reference for all the analog control levels and GND (digital ground) is
the reference for the digital electronics and the incoming power supply. COM and GND should never be connected
together with external wiring. Never place This control systems control lines in conduit with other wires, or flickering
problems could occur.
Make star or daisy chain connections.
In this electronics system, it is important for all the COM signals to be connected in a start or daisy-chain configuration,
as opposed to a ring o loop configuration. The reason is that a ring or loop configuration usually acts like a big
antenna which is excited and aggravated by adjacent power lines. Apply the following rules:
DMX daisy-chain configuration rules:
(multiple DMX Stations connected in serial along one DMX-512 line)
1. Do not connect COM between DMX stations.
2. Use a separate power supply for each DMX station.
3. Daisy-chain the DMX-512 signal as normal, connecting the shield drain to DGND.
DMX bridge rules:
(2 or more DMX Stations tied together with COM, each processing its’ own DMX-512 line)
1. Tie stations together using COM
2. Use a separate 10V/5VA transformer for each DMX Station
3. Connect the shield drain wire to DGND on the DMX-1 station.
4. Do not connect the shield drain wire to DGND on additional DMX stations (DMX-2, 3, 4 _). Leave the DGND
Terminals or DMX IN/OUT empty. The DMX shield can be passed through the station location, but it should
not touch or connect to anything in the box.
Page 14 of 40
Leviton Remembrance Control Stations
Page 15
User Guide
ADVANCED TOPICS
Use of blocking (steering) Diodes.
What is a Diode?
A diode is a one-way valve. It allows current to flow in a forward direction, but not in a reverse direction. The input
is the anode, or un-banded end of the part; and the output is the cathode, or banded end of the part. When the input
(anode) is at a voltage potential higher than the output (cathode), current will pass from the input to the output until
it fills up the output connection to nearly the same voltage level as available on the input connection. When the
output voltage rises higher than the input voltage, the part shuts off
Analog Channel Grouping
Use 1N4148 or 1N914 diodes to select multiple Analog Channels to be controlled by a single fader, Entry, or Panic
station. This is done by connecting the banded end (cathode) of the diodes to each of the Analog Channels to be
controlled. Tie the un-banded ends together, and to the single VOUT or A (1-6) single fader control line that is to
control the channels. The diodes will keep the channels to be controlled separate except when the source channel
is active. The 1N4148 or 1N914 is considered a signal diode. It is excellent for quick linear response in low-current
applications, however it has a tendency to fail in high current applications.
Master/Slave Take Control
Un 1N4004 diodes to create Master/Slave take Control relationships between control stations. This is implemented
by attaching the un-banded end (anode) to the master station, and the banded end (cathode) to the slave station(s).
The master station will now be able to take control away from the slave station(s), but the slave station(s) will not be
able to take control away from the master station. The master station will act as an independent from the slave(s)
stations point of view. The slave station will also be unable to record presets if the master station is a DMX station,
as the record operation is a function of the take control circuit. The 1N4004 is considered a rectifier diode, and is
excellent for high-current applications, like the take control circuitry, but it would perform poorly as a signal diode,
because it requires significant current to operate properly.
Leviton Remembrance Control Stations
Page 15 of 40
Page 16
User Guide
ADDENDUM
Concerning New REMEMBRANCE Preset Stations:
Wiring Details
8 Preset Station:Refer to 8 Channel Analog Station Wiring Diagram and Colortran
(8-1028, 8-1148, 8-1188)Colortran Production Drawings for connection details of this Preset
Station in your specific system.
4 Preset Station:Refer to Colortan Production Drawings for connection
(8-1024, 8-1144)details of this Preset Station in your specific system. Note
the following control wire mapping.
Station Terminal A2 = Preset #1 (usually System A1)
Station Terminal A3 = Preset #2 (usually System A2)
Station Terminal A6 = Preset #3 (usually System A3)
Station Terminal A7 = Preset #4 (usually System A4)
Station Terminal +V = +V for system
Station Terminal COM = COM for system
Station Terminal T/C = T/C as applicable in system design.
Jumper Settings
NOTE
Connect Station Terminal A1 to Station Terminal A2 on 4 preset
stations to activate Preset 1 on power up.
JP3 IN:Enable Snapshot Record feature from this Station DMX-512 Scene
Snapshot Record may be enabled if T/C is connected to recording
processor (either i series e control module, or REMEMBRANCE ANA2DMX
processor). The station will also activate presets, and take control away
from other stations connected to its’ T/C line. Refer to Colortan Production
Drawings for connection details, and refer to the snapshot record procedure
below for operational details. The “OFF” LED will stay red while the “OFF”
switch is pressed.
JP3 OUT:Disable Snapshot Record from this station. The station will only activate
presets, and take control away from other stations connected to its’ T/C.
Line. The OFF LED will pulse red when the “OFF” switch is pressed.
JP5 IN:Activate Preset 1 on power up. Preset 1 will automatically turn on when
power is applied to the station.
JP5OUT:Activate OFF on power up. All preset will be off when power is applied to
the control station.
Page 16 of 40
Leviton Remembrance Control Stations
Page 17
User Guide
Preset Station DMX-512 Snapshot Record Procedure
1. JP3 must be installed on this station.
2. Activate DMX-512 scene from control console or DMX-512 portion of control station. On i series e racks, or
i series e Quad racks, a relative fade time for the preset may be assigned by setting DMX channels 511 and
512 to the same control level as follows:
3. Turn off all other control sources, so only DMX-512 generated scene is active.
4. Press and hold the “OFF” Button. The “OFF” LED will turn and stay red.
5. Continue pressing the OFF switch for at least 5 seconds. If the preset station is connected to an i series e
rack, the lights will dim when the snapshot mode has been enabled. If the station is connected to an ANA2DMX
processor, wait an extra second or two to insure that the processor is in snapshot mode.
6. While holding the OFF switch, press the preset switch where you would like the DMX512 scene stored.
7. Continue to hold the OFF button for another second or until the lights return to their normal levels.
8. Release the OFF button.
Leviton Remembrance Control Stations
Page 17 of 40
Page 18
User Guide
MASTER
ON / OFF
Remembrance
MASTER
ON / OFF
Remembrance
COM
+V
T/C
VOUT
A1
A2
A3
COM
+V
T/C
VOUT
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
10VACX
10VACY
REC LOCK
DMX OUT+
DMX OUT-
DGND OUT
DMX IN+
DMX IN-
DGND IN
A
MASTER
ON / OFF
Remembrance
COM
+V
T/C
VOUT
A1
A2
A3
B
ROOM 1
3 CHANNEL ANALOG
CAT. NO. 003-RMB81-3
COMBINE ROOMS
MASTER
ON / OFF
Remembrance
COM
+V
T/C
VOUT
A1
A2
A3
A
MASTER
ON / OFF
Remembrance
COM
+V
T/C
VOUT
A1
A2
A3
B
ROOM 2
CHANNEL ANALOG
CAT. NO. 003-RMB81-3
10V/5VA FXMR
BY OTHERS
A/V BOOTH MASTER STATION
12 CHANNEL DMX STATION CAT. NO. 019-RMB81-112
SLAVE STATIONS
LOCKOUT
COMBINE ROOMS
MASTER
ON / OFF
Remembrance
COM
+V
T/C
VOUT
A1
A2
A3
A
MASTER
ON / OFF
Remembrance
COM
+V
T/C
VOUT
A1
A2
A3
B
ROOM 3
3 CHANNEL ANALOG
CAT. NO. 003-RMB81-3
COMBINE ROOMS
MASTER
ON / OFF
Remembrance
COM
+V
T/C
VOUT
A1
A2
A3
A
MASTER
ON / OFF
Remembrance
COM
+V
T/C
VOUT
A1
A2
A3
B
ROOM 4
3 CHANNEL ANALOG
CAT. NO. 003-RMB81-3
COMBINE ROOMS
120VAC
CONTROL CONSOLE
DMX-512 BELDEN 9829 BY OTHERS
DMX-512 BELDEN 9829 BY OTHERS
DIMMER
RACK
ROOM 1
ROOM 2
ROOM 4
ROOM 3
A/V BOOTH
AIR WALLS
A
A
A
A
B
B
B
B
NOTE
SAMPLE SYSTEM CONFIGURATIONS
Page 18 of 40
Multi-Purpose Room With A/V Control Booth
Use Alpha #1898 wire between
all control stations.
Leviton Remembrance Control Stations
Page 19
COM
+V
T/C
VOUT
A1
A2
COM
+V
T/C
VOUT
A1
A2
A3
A4
A5
A6
A7
A8
COM
+V
T/C
VOUT
A1
A2
COM
+V
T/C
VOUT
HOUSE DOWNLIGHTS
VESTIBULE
NSI CAT. NO. N2408
VESTIBULE
ENTRY STATION
CAT. NO. 010-RMB81-21
HOUSE RIGHT
TWO CHANNEL
ANALOG STATION
CAT. NO. 002-RMB81-2
HOUSE LEFT
TWO CHANNEL
ANALOG STATION
CAT. NO. 002-RMB81-2
PODIUM
SANCTUARY WASH
SOLOIST
CHOIR
BABTISMAL
HOUSE CHANDELIER
HOUSE DOWNLIGHTS
VESTIBULE
SANCTUARY (MASTER STATION)
8 CHANNEL ANALOG STATION
CAT. NO. 007-RMB81-8
MASTER
ON / OFF
Remembrance
ON / OFF
Remembrance
ON / OFF
Remembrance
ON / OFF
Remembrance
DMX -
DMX -
DMX +
DMX +
MCPX
MCPX
+ 15V
+ 15V
REM +
REM +
REM -
REM-
1
2
3
4
COM
COM
1
2
3
4
COM
COM
NOTE
User Guide
Small Church (All Analog Stations)
Leviton Remembrance Control Stations
Use Alpha #1898 wire between
all control stations.
Page 19 of 40
Page 20
User Guide
MASTER
ON / OFF
Remembrance
MASTER
ON / OFF
Remembrance
COM
+V
T/C
VOUT
A1
A2
A3
COM
+V
T/C
VOUT
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
COM
+V
T/C
VOUT
10VACX
10VACY
REC LOCK
DMX OUT+
DMX OUT-
DGND OUT
DMX IN+
DMX IN-
DGND IN
A
MASTER
ON / OFF
Remembrance
COM
+V
T/C
VOUT
A1
A2
A3
B
MASTER
ON / OFF
Remembrance
COM
+V
T/C
VOUT
A1
A2
A3
3 CHANNEL ANALOG STATIONS
CAT. NO. 003-RMB81-3
HOUSELIGHT
STATIONS
3 ENTRY STATIONS
CAT. NO. 010-RMB81-21
ENTRY (CLEANING)
STATIONS
10V/5VA FXMR
BY OTHERS
CONTROL BOOTH
12 CHANNEL DMX STATION
CAT. NO. 019-RMB81-112
REHERSAL
LIGHTS
HOUSE
LIGHTS
ENTRY
ENTRY STATION
CAT. NO. 010-RMB81-21
HOUSELIGHT /
ENTRY STATIONS
LOCKOUT
HOUSELIGHT /
ENTRY STATIONS
LOCKOUT
120VAC
CONTROL CONSOLE
DMX-512 BELDEN 9829 BY OTHERS
DMX-512 BELDEN 9829 BY OTHERS
DIMMER
RACK
ON / OFF
Remembrance
MASTER
ON / OFF
Remembrance
COM
+V
T/C
VOUT
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
COM
+V
T/C
VOUT
STAGE MANAGERS PANEL
12 CHANNEL ANALOG STATION
CAT. NO. 019-RMB81-112
ENTRY STATION
CAT. NO. 010-RMB81-21
ON / OFF
Remembrance
COM
+V
T/C
VOUT
B
ON / OFF
Remembrance
COM
+V
T/C
VOUT
B
ON / OFF
Remembrance
COM
+V
T/C
VOUT
B
ON / OFF
Remembrance
NOTE
Theater With Houselights / Rehearsal Lights
Page 20 of 40
Use Alpha #1898 wire between
all control stations.
Leviton Remembrance Control Stations
Page 21
User Guide
MASTER
ON / OFF
Remembrance
COM
+V
T/C
VOUT
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
AC1
AC2
REC LOCK
DMX OUT+
DMX OUT-
DGND OUT
DMX IN+
DMX IN-
DGND IN
10V/5VA FXMR
BY OTHERS
CONTROL BOOTH
12 CHANNEL DMX STATION
CAT. NO. 019-RMB81-112
MASTER
ON / OFF
Remembrance
COM
+V
T/C
VOUT
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
HEAD USHERS PANEL
12 CHANNEL ANALOG STATION
CAT. NO. 009-RMB81-12
120VAC
CONTROL CONSOLE
DMX2DMX1
BELDEN #9829
BY OTHERS
DRAIN WIRE PASSES
TRHROUGH STATION
LOCATION, BUT IS
INSULATED FROM
STATION AND
ENCLOSURE
BELDEN #9829
BY OTHERS
ALPHA #1898/15C
BY OTHERS
MASTER
ON / OFF
Remembrance
COM
+V
T/C
VOUT
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
AC1
AC2
REC LOCK
DMX OUT+
DMX OUT-
DGND OUT
DMX IN+
DMX IN-
DGND IN
10V/5VA FXMR
BY OTHERS
STAGE MANAGERS PANEL
12 CHANNEL DMX STATION
CAT. NO. 019-RMB81-112
MASTER
ON / OFF
Remembrance
COM
+V
T/C
VOUT
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
PODIUM / DESIGNERS REMOTE
12 CHANNEL ANALOG STATION
CAT. NO. 009-RMB81-12
120VAC
DIMMER
RACKS
NOTE
Dual DMX-512 Bridge
Leviton Remembrance Control Stations
Use Alpha #1898 wire between
all control stations.
Page 21 of 40
Page 22
User Guide
WIRING DIAGRAMS
ON / OFF
Remembrance
FRONT VIEW
REAR VIEW
5/16"
ELECTRONICS
NO K/O
ACCESS
1"
TB1
A6
10
A5
9
A4
8
A3
7
A2
6
A1
5
VOUT
4
T/C
3
+V
2
COM
1
TERMINAL BLOCK
ORANGE
NO CONNECT
WHITE
RED
BLACK
3 1/2"
FAIR
K/O
ACCESS
BEST
K/O
ACCESS
BEST
K/O
ACCESS
FAIR
K/O
ACCESS
2 GANG
3-1/2" DEEP
BACK BOX
BY OTHERS
FAIR
K/O
ACCESS
FAIR
K/O
ACCESS
ALPHA
1898/5C
BY OTHERS
GREEN-VOUT FROM
ENTRY STATION /
PANIC STATION
ANALOG
CONTROL
HARNESS
TO OTHER
STATIONS
OR TO
0-10V DIMMERS
Page 22 of 40
SIDE VIEW
1 Channel Analog Station (Cat. No. 001-RMB81-001)
Leviton Remembrance Control Stations
Page 23
ON / OFF
FRONT VIEW
Remembrance
TB1
A6
10
A5
9
A4
8
A3
7
BLUE
A2
6
ORANGE
A1
5
NO CONNECT
VOUT
4
WHITE
T/C
3
RED
+V
2
BLACK
COM
1
ALPHA
1898/6C
BY OTHERS
ANALOG
CONTROL
HARNESS
TO OTHER
STATIONS
OR TO
0-10V DIMMERS
User Guide
REAR VIEW
5/16"
ELECTRONICS
NO K/O
ACCESS
SIDE VIEW
1"
TERMINAL BLOCK
3 1/2"
FAIR
K/O
ACCESS
BEST
K/O
ACCESS
BEST
K/O
ACCESS
FAIR
K/O
ACCESS
2 GANG
3-1/2" DEEP
BACK BOX
BY OTHERS
FAIR
K/O
ACCESS
FAIR
K/O
ACCESS
GREEN-VOUT FROM
ENTRY STATION /
PANIC STATION
2 Channel Analog Station (Cat. No. 002-RMB81-002)
Leviton Remembrance Control Stations
Page 23 of 40
Page 24
User Guide
ON / OFF
FRONT VIEW
MASTER
Remembrance
TB1
A6
10
A5
9
A4
8
BROWN
A3
7
BLUE
A2
6
ORANGE
A1
5
NO CONNECT
VOUT
4
WHITE
T/C
3
RED
+V
2
BLACK
COM
1
ALPHA
1898/7C
BY OTHERS
ANALOG
CONTROL
HARNESS
TO OTHER
STATIONS
OR TO
0-10V DIMMERS
REAR VIEW
5/16"
ELECTRONICS
NO K/O
ACCESS
SIDE VIEW
1"
TERMINAL BLOCK
3 1/2"
FAIR
K/O
ACCESS
BEST
K/O
ACCESS
BEST
K/O
ACCESS
FAIR
K/O
ACCESS
4 GANG
3-1/2" DEEP
BACK BOX
BY OTHERS
FAIR
K/O
ACCESS
FAIR
K/O
ACCESS
GREEN-VOUT FROM
ENTRY STATION /
PANIC STATION
Page 24 of 40
3 Channel Analog Station (Cat. No. 003-RMB81-003)
Leviton Remembrance Control Stations
Page 25
ON / OFF
FRONT VIEW
MASTER
Remembrance
TB1
A6
10
A5
9
YELLOW
A4
8
BROWN
A3
7
BLUE
A2
6
ORANGE
A1
5
NO CONNECT
VOUT
4
WHITE
T/C
3
RED
+V
2
BLACK
COM
1
ALPHA
1898/8C
BY OTHERS
User Guide
ANALOG
CONTROL
HARNESS
TO OTHER
STATIONS
OR TO
0-10V DIMMERS
REAR VIEW
5/16"
ELECTRONICS
NO K/O
ACCESS
SIDE VIEW
1"
TERMINAL BLOCK
3 1/2"
FAIR
K/O
ACCESS
BEST
K/O
ACCESS
BEST
K/O
ACCESS
FAIR
K/O
ACCESS
4 GANG
3-1/2" DEEP
BACK BOX
BY OTHERS
FAIR
K/O
ACCESS
FAIR
K/O
ACCESS
GREEN-VOUT FROM
ENTRY STATION /
PANIC STATION
4 Channel Analog Station (Cat. No. 004-RMB81-004)
Leviton Remembrance Control Stations
Page 25 of 40
Page 26
User Guide
ON / OFF
FRONT VIEW
MASTER
Remembrance
TB1
GRAY
A6
10
VIOLET
A5
9
YELLOW
A4
8
BROWN
A3
7
BLUE
A2
6
ORANGE
A1
5
NO CONNECT
VOUT
4
WHITE
T/C
3
RED
+V
2
BLACK
COM
1
ALPHA
1898/10C
BY OTHERS
ANALOG
CONTROL
HARNESS
TO OTHER
STATIONS
OR TO
0-10V DIMMERS
REAR VIEW
5/16"
ELECTRONICS
NO K/O
ACCESS
SIDE VIEW
1"
TERMINAL BLOCK
3 1/2"
FAIR
K/O
ACCESS
BEST
K/O
ACCESS
BEST
K/O
ACCESS
FAIR
K/O
ACCESS
5 GANG
3-1/2" DEEP
BACK BOX
BY OTHERS
FAIR
K/O
ACCESS
FAIR
K/O
ACCESS
GREEN-VOUT FROM
ENTRY STATION /
PANIC STATION
Page 26 of 40
5 Channel Analog Station (Cat. No. 005-RMB81-005)
Leviton Remembrance Control Stations
Page 27
ON / OFF
FRONT VIEW
MASTER
Remembrance
TB1
GRAY
A6
10
VIOLET
A5
9
YELLOW
A4
8
BROWN
A3
7
BLUE
A2
6
ORANGE
A1
5
NO CONNECT
VOUT
4
WHITE
T/C
3
RED
+V
2
BLACK
COM
1
ALPHA
1898/10C
BY OTHERS
User Guide
ANALOG
CONTROL
HARNESS
TO OTHER
STATIONS
OR TO
0-10V DIMMERS
REAR VIEW
5/16"
ELECTRONICS
NO K/O
ACCESS
SIDE VIEW
1"
TERMINAL BLOCK
3 1/2"
FAIR
K/O
ACCESS
BEST
K/O
ACCESS
BEST
K/O
ACCESS
FAIR
K/O
ACCESS
5 GANG
3-1/2" DEEP
BACK BOX
BY OTHERS
FAIR
K/O
ACCESS
FAIR
K/O
ACCESS
GREEN-VOUT FROM
ENTRY STATION /
PANIC STATION
6 Channel Analog Station (Cat. No. 006-RMB81-006)
Leviton Remembrance Control Stations
Page 27 of 40
Page 28
MASTER
ON / OFF
Remembrance
FRONT VIEW
REAR VIEW
A12
A2
A10
A9
A8
A7
A6
A5
A4
A3
A2
A1
VOUT
T/C
+V
COM
10
9
8
7
6
5
4
3
2
1
GRAY
VIOLET
YELLOW
BROWN
BLUE
ORANGE
NO CONNECT
WHITE
RED
BLACK
GREEN-VOUT FROM
ENTRY STATION /
PANIC STATION
ALPHA
1898/12C
BY OTHERS
TAN
PINK
6
5
4
3
2
1
TB1
TB2
ANALOG
CONTROL
HARNESS
TO OTHER
STATIONS
OR TO
0-10V DIMMERS
SIDE VIEW
ELECTRONICS
TERMINAL BLOCK
BEST
K/O
ACCESS
BEST
K/O
ACCESS
FAIR
K/O
ACCESS
NO K/O
ACCESS
FAIR
K/O
ACCESS
FAIR
K/O
ACCESS
FAIR
K/O
ACCESS
6 GANG
3-1/2" DEEP
BACK BOX
BY OTHERS
5/16"
3 1/2"
1"
User Guide
Page 28 of 40
Leviton Remembrance Control Stations
8 Channel Analog Station (Cat. No. 007-RMB81-008)
Page 29
MASTER
ON / OFF
Remembrance
FRONT VIEW
REAR VIEW
A12
A2
A10
A9
A8
A7
A6
A5
A4
A3
A2
A1
VOUT
T/C
+V
COM
10
9
8
7
6
5
4
3
2
1
GRAY
VIOLET
YELLOW
BROWN
BLUE
ORANGE
NO CONNECT
WHITE
RED
BLACK
GREEN-VOUT FROM
ENTRY STATION /
PANIC STATION
ALPHA
1898/14C
BY OTHERS
RED/YEL
RED/GRN
TAN
PINK
6
5
4
3
2
1
TB1
TB2
ANALOG
CONTROL
HARNESS
TO OTHER
STATIONS
OR TO
0-10V DIMMERS
SIDE VIEW
ELECTRONICS
TERMINAL BLOCK
BEST
K/O
ACCESS
BEST
K/O
ACCESS
FAIR
K/O
ACCESS
NO K/O
ACCESS
FAIR
K/O
ACCESS
FAIR
K/O
ACCESS
FAIR
K/O
ACCESS
7 GANG
3-1/2" DEEP
BACK BOX
BY OTHERS
5/16"
3 1/2"
1"
User Guide
Leviton Remembrance Control Stations
10 Channel Analog Station (Cat. No. 008-RMB81-010)
Page 29 of 40
Page 30
MASTER
ON / OFF
Remembrance
FRONT VIEW
REAR VIEW
A12
A2
A10
A9
A8
A7
A6
A5
A4
A3
A2
A1
VOUT
T/C
+V
COM
10
9
8
7
6
5
4
3
2
1
GRAY
VIOLET
YELLOW
BROWN
BLUE
ORANGE
NO CONNECT
WHITE
RED
BLACK
GREEN-VOUT FROM
ENTRY STATION /
PANIC STATION
ALPHA
1898/16C
BY OTHERS
WHT/BLK
RED/BLK
RED/YEL
RED/GRN
TAN
PINK
6
5
4
3
2
1
TB1
TB2
ANALOG
CONTROL
HARNESS
TO OTHER
STATIONS
OR TO
0-10V DIMMERS
SIDE VIEW
ELECTRONICS
TERMINAL BLOCK
BEST
K/O
ACCESS
BEST
K/O
ACCESS
FAIR
K/O
ACCESS
NO K/O
ACCESS
FAIR
K/O
ACCESS
FAIR
K/O
ACCESS
FAIR
K/O
ACCESS
8 GANG
3-1/2" DEEP
BACK BOX
BY OTHERS
5/16"
3 1/2"
1"
User Guide
Page 30 of 40
12 Channel Analog Station (Cat. No. 009-RMB81-012)
Leviton Remembrance Control Stations
Page 31
ON / OFF
Remembrance
FRONT VIEW
TB1
GREEN
VOUT
4
WHITE
T/C
3
RED
+V
2
BLACK
COM
1
ALPHA
1898/4C
BY OTHERS
ANALOG / DMX STATION TERMINATION REFERENCE
CONNECT AS
DESIRED TO
TERMINALS ON
APPROPRIATE
ANALOG
STATION.
CONTROL FOR
CHANNELS 1
THRU 12 SHOWN.
CONNECTED
ANALOG
CHANNELS
WILL GO TO
FULL WHEN
PANIC SWITCH
IS PRESSED
ANALOG
CONTROL
HARNESS
TO OTHER
STATIONS
OR TO
0-10V DIMMERS
User Guide
PRP-31316-02 IS CALLED OUT SEPERATELY.
SHOWN HERE FOR REFERENCE ONLY.
ACTIVE DMX-512 IN
AND RECORD DISABLED
OR CHANNEL MODE
SOLID GREEN= PLAY MODE WITH
NO DMX IN AND
RECORD DISABLED
OR CHANNEL MODE
SOLID YELLOW= PLAY MODE WITH
NO DMX IN AND
RECORD ENABLED
DIAGNOSTIC
LED
FUNCTION
LED
Note:
Terminal Blocks
are plugable
JUMPER SETTINGS
JP1 * OFF = SCENE SAVER MODE
ON = CHANNEL MODE
JP2 * OFF = RECORD ENABLE (SS MODE ONLY)
ON = RECORD LOCKOUT (SS MODE ONLY)
JP3 * OFF = STATION ALWAYS OUTPUTS DMX-512
ON = NO DMX OUTPUT WHEN STATION IS OFF
JP4 * OFF = CHANNEL MODE SINGLE SEQUENCE
ON = CHANNEL MODE DUAL REPEAT SEQUENCE
JP5 * OFF = CHANNELS PILE ONTO DMX-512 IN
ON = CHANNELS REPLACE DMX-512 IN LVLS.
JP6 * OFF = 6 CHANNEL STATION
ON = 4 CHANNEL STATION
JP7 RESERVED
* DEFAULT
SETTING
User Guide
4 Channel DMX-512 Station (Cat. No. 017-RMB81-104)
Leviton Remembrance Control Stations
Page 33 of 40
Page 34
User Guide
MASTER
5/16"
NO K/O ACCESS
FAIR
K/O
ACCESS
8 GANG
3-1/2" DEEP
BACK BOX
BY OTHERS
ON / OFF
FRONT VIEW
EDWARDS #590
DORMEYER #DCT 5-120
OTHERS MAY APPLY
120 VAC
BY OTHERS
DMX-512 IN
FROM CONSOLE
PUSH
1
5
2
4
3
5 PIN XLR
FRONT VIEW
10 VAC 5VA
LISTED CLASS 2
TRANSFORMER
BY OTHERS
DRAIN WIRE
WHITE/BLUE
BLUE/WHT
DMX-512 START ADDRESS
(CHANNEL MODE ONLY)
Note:
Terminal Blocks
are plugable
DRAIN WIRE
GND
9
WHITE/BLUE
DMX-
8
IN
OUT
DMX+
GND
DMXDMX+
RECL
AC1
AC2
BLUE/WHT
7
DRAIN WIRE
6
WHITE/BLUE
5
BLUE/WHT
4
3
2
1
DMX
DMX
18 GAUGE 600V WIRE
BY OTHERS
BELDEN 9829
BY OTHERS
LED
BELDEN 9829
BY OTHERS
TB3
REAR VIEW
DRAIN WIRE
WHITE/BLUE
BLUE/WHT
Remembrance
TB1
GRAY
A6
10
VIOLET
A5
9
YELLOW
A4
8
BROWN
A3
7
BLUE
A2
6
ORANGE
A1
5
NO CONNECT
VOUT
4
WHITE
T/C
3
RED
+V
2
BLACK
COM
1
TO DIMMER RACK
DMX-512 OUT
SHIELD
DATA DATA +
1
5 PIN XLR
FRONT VIEW
MODULE
ELECTRONICS
1 1/2"
2"
3 1/2"
TERMINAL BLOCK
BEST
K/O
ACCESS
BEST
K/O
ACCESS
FAIR
K/O
ACCESS
FAIR
K/O
ACCESS
FAIR
K/O
ACCESS
SIDE VIEW
ANALOG
ALPHA
1898/10C
BY OTHERS
GREEN-VOUT FROM
ENTRY STATION /
PANIC STATION
JUMPER SETTINGS
JP1 * OFF = SCENE SAVER MODE
ON = CHANNEL MODE
JP2 * OFF = RECORD ENABLE (SS MODE ONLY)
ON = RECORD LOCKOUT (SS MODE ONLY)
JP3 * OFF = STATION ALWAYS OUTPUTS DMX-512
ON = NO DMX OUTPUT WHEN STATION IS OFF
JP4 * OFF = CHANNEL MODE SINGLE SEQUENCE
ON = CHANNEL MODE DUAL REPEAT SEQUENCE
JP5 * OFF = CHANNELS PILE ONTO DMX-512 IN
ON = CHANNELS REPLACE DMX-512 IN LVLS.
JP6 * OFF = 6 CHANNEL STATION
ON = 4 CHANNEL STATION
JP7 RESERVED
BLINKING RED= RECORD MODE
5
2
4
3
LED
DIAGNOSTIC
LED
FUNCTION
BLINKING YELLOW = PLAY MODE WITH
BLINKING GREEN = PLAY MODE WITH
SOLID GREEN= PLAY MODE WITH
SOLID YELLOW= PLAY MODE WITH
CONTROL
HARNESS
TO OTHER
STATIONS
OR TO
0-10V DIMMERS
* DEFAULT
SETTING
ACTIVE DMX-512 IN
AND RECORD ENABLED
ACTIVE DMX-512 IN
AND RECORD DISABLED
OR CHANNEL MODE
NO DMX IN AND
RECORD DISABLED
OR CHANNEL MODE
NO DMX IN AND
RECORD ENABLED
Page 34 of 40
6 Channel DMX-512 Station (Cat. No. 018-RMB81-106)
Leviton Remembrance Control Stations
Page 35
MASTER
ON / OFF
Remembrance
FRONT VIEW
REAR VIEW
A12
A11
A10
A9
A8
A7
A6
A5
A4
A3
A2
A1
VOUT
T/C
+V
COM
10
9
8
7
6
5
4
3
2
1
GRAY
VIOLET
YELLOW
BROWN
BLUE
ORANGE
NO CONNECT
WHITE
RED
BLACK
GREEN-VOUT FROM
ENTRY STATION /
PANIC STATION
ALPHA
1898/16C
BY OTHERS
BELDEN 9829
BY OTHERS
18 GAUGE 600V WIRE
BY OTHERS
EDWARDS #590
DORMEYER #DCT 5-120
OTHERS MAY APPLY
120 VAC
BY OTHERS
BELDEN 9829
BY OTHERS
BELDEN 9829
BY OTHERS
DMX-512 IN
FROM CONSOLE
5 PIN XLR
FRONT VIEW
TO DIMMER RACK
DMX-512 OUT
5 PIN XLR
FRONT VIEW
WHT/BLK
RED/BLK
RED/YEL
RED/GRN
TAN
PINK
6
5
4
3
2
1
TB1
TB3TB3
TB2
ANALOG
CONTROL
HARNESS
TO OTHER
STATIONS
OR TO
0-10V DIMMERS
DMX-512 START ADDRESS
(CHANNEL MODE ONLY)
DMX-512 START ADDRESS
(CHANNEL MODE ONLY)
GND
DMX-
DMX+
GND
DMX-
DMX+
RECL
AC1
AC2
9
8
7
6
5
4
3
2
1
DRAIN WIRE
WHITE/BLUE
BLUE/WHT
DRAIN WIRE
WHITE/BLUE
BLUE/WHT
DMX
OUT
DMX
IN
DRAIN WIRE
WHITE/BLUE
BLUE/WHT
DRAIN WIRE
WHITE/BLUE
BLUE/WHT
SHIELD
DATA-
DATA+
GND
DMX-
DMX+
GND
DMX-
DMX+
RECL
AC1
AC2
9
8
7
6
5
4
3
2
1
DRAIN WIRE
WHITE/BLUE
BLUE/WHT
DRAIN WIRE
WHITE/BLUE
BLUE/WHT
DMX
OUT
DMX
IN
1
5
4
2
3
1
5
4
2
3
10 VAC 5VA
LISTED CLASS 2
TRANSFORMER
BY OTHERS
PUSH
SIDE VIEW
ELECTRONICS
MODULE
TERMINAL BLOCK
BEST
K/O
ACCESS
BEST
K/O
ACCESS
FAIR
K/O
ACCESS
FAIR
K/O
ACCESS
FAIR
K/O
ACCESS
FAIR
K/O
ACCESS
8 GANG
3-1/2" DEEP
BACK BOX
BY OTHERS
5/16"
3 1/2"
1 1/2"
2"
NO K/O ACCESS
LED
LED
BLINKING RED= RECORD MODE
BLINKING YELLOW = PLAY MODE WITH
ACTIVE DMX-512 IN
AND RECORD ENABLED
BLINKING GREEN = PLAY MODE WITH
ACTIVE DMX-512 IN
AND RECORD DISABLED
OR CHANNEL MODE
SOLID GREEN= PLAY MODE WITH
NO DMX IN AND
RECORD DISABLED
OR CHANNEL MODE
SOLID YELLOW = PLAY MODE WITH
NO DMX IN AND
RECORD ENABLED
DIAGNOSTIC
LED
FUNCTION
LED
Note:
Terminal Blocks
are plugable
Note:
Terminal Blocks
are plugable
JUMPER SETTINGS
JP1 * OFF = SCENE SAVER MODE
ON = CHANNEL MODE
JP2 * OFF = RECORD ENABLE (SS MODE ONLY)
ON = RECORD LOCKOUT (SS MODE ONLY)
JP3 * OFF = STATION ALWAYS OUTPUTS DMX-512
ON = NO DMX OUTPUT WHEN STATION IS OFF
JP4 * OFF = CHANNEL MODE SINGLE SEQUENCE
ON = CHANNEL MODE DUAL REPEAT SEQUENCE
JP5 * OFF = CHANNELS PILE ONTO DMX-512 IN
ON = CHANNELS REPLACE DMX-512 IN LVLS.
JP6 * OFF = 6 CHANNEL STATION
ON = 4 CHANNEL STATION
JP7 RESERVED
* DEFAULT
SETTING
User Guide
Leviton Remembrance Control Stations
12 Channel DMX-512 Station (Cat. No. 019-RMB81-112)
Page 35 of 40
Page 36
User Guide
ANALOG
CONTROL
HARNESS
FROM
ANALOG
STATION(S)
ALPHA
# 1898
BY OTHERS
NSI Cat. No. N2408
1:1 DIMMER
TERMINATION
ORANGE
BLUE
BROWN
YELLOW
BLACK
WHITE
NOT USED
GREEN
NOT USED
RED
Colortran Model ENR 96
8 Channel Houselight
DIMMER TERMINATION
1
2
3
4
COM
COM
DMXDMXDMX+
DMX+
MCPX
MCPX
+15V
+15V
REM+
REM+
REMREM-
1
2
3
4
COM
COM
Colortran Model ENR 12 OR 24 with
Universal Control Module # 166-902 (3)
1:1 (1-12) DIMMER TERMINATION
ORANGE
BLUE
BROWN
YELLOW
VIOLET
GRAY
PINK
TAN
ANALOG
CONTROL
HARNESS
FROM
ANALOG
STATION(S)
ALPHA
# 1898
BY OTHERS
RED/GRN
RED/YEL
RED/BLK
WHT/BLK
BLACK
WHITE
NOT USED
GREEN
NOT USED
RED
1
2
3
4
5
6
7
8
9
10
11
12
600
600
13
14
15
16
17
18
19
20
21
22
23
24
600
+V
600
TC2
TC3
TC4
NOTE:
CONNECT GREEN WIRE TO
VOUT ON ANALOG STATIONS
FOR THIS APPLICATION ONLY.
ANALOG
CONTROL
HARNESS
FROM
ANALOG
STATION(S)
ALPHA
# 1898
BY OTHERS
BLACK
PANIC
RED
GREEN
WHITE
Remembrance
CAT. NO. 011-RMB81-22
PN2222A
BOTTOM VIEW
GREEN
1K OHMS
VOUT
WHITE
NOT USED
1
2
CONTROL
3
IN
4
5
IN
6
B
LED
GND
E
C
BLACK
RED
ORANGE
BLUE
BROWN
YELLOW
VIOLET
GRAY
PINK
TAN
PANIC
7
8
9
10
11
12
13
HOUSE
14
LIGHTS
15
16
17
18
19
20
0-10V Analog Dimmer
Page 36 of 40
Leviton Remembrance Control Stations
Page 37
User Guide
Leviton Remembrance Control Stations
Page 37 of 40
Page 38
User Guide
WARRANTY
LIMITED TWO YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product
at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use
for two years from the purchase date. Leviton’s only obligation is to correct such defects by repair or
replacement, at its option, if within such two year period the product is returned prepaid, with proof of purchase
date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Service Department,20497 SW Teton Ave., Tualatin, Oregon 97062. All products returned to Leviton-NSI must have factory
authorization for return prior to shipping. The purchaser is responsible for completing and mailing to Leviton,
within 15 days of purchase, the warranty registration card enclosed with each product. This warranty excludes
and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if
this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or
altered in any manner, or is not used under normal operating conditions or not in accordance with any labels
or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for
a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any
such implied warranty, including merchantability and fitness for a particular purpose, is limited to two years.
Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation,
damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty
obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on
contract, tort or otherwise.