Leviton RE151-RN Installation Manual

Page 1
TM
SINGLE POLE SWITCH
Cat. No. RE151 - Rated: 15A-120/277V AC
3-WAY SWITCH
Cat. No. RE153 - Rated: 15A-120/277V AC
INSTALLATION
PK-93713-10-02-2A
English
WARNING: TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH ELECTRICAL CODES AND REGULATIONS.
CAUTION: USE THIS DEVICE WITH COPPER OR COPPER CLAD WIRE ONLY. NOTE: This device uses a self-grounding clip that provides an automatic ground connection only when installed in a properly grounded
metal wallbox.
1. WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE
POWER IS OFF BEFORE WIRING!
2. Connect wires per appropriate WIRING DIAGRAM, using one of the wiring methods below. NOTE: Quickwire™ terminals accept #14 AWG solid copper wires ONLY!. Back and side wire terminal screws accept up to #12 AWG
copper or copper clad wire.
3A. TO QUICKWIRE™: Remove insulation per strip gauge on device approx. 5/8" (1.6 cm). Insert straight #14 AWG solid copper wires into
round Quickwire™ holes. To replace or rewire after Quickwiring, gently press the tip of a small screwdriver in the release slot and back the wire out gradually.
3B. TO BACKWIRE: Remove insulation per strip gauge on device approx. 5/8" (1.6 cm). Insert straight wires under clamps of appropriate
terminal screws. Tighten screws rmly.
3C. TO SIDE WIRE: Remove insulation approx. 3/4" (1.9 cm). Loop wires clockwise 3/4 turn around terminal screws. Firmly tighten screws
over wire loops.
3D. The GROUND terminal on this device may be wired in the traditional side wire method or as follows: Slide wire straight between screw
head and tab and insert into hole per FIGURE 1 (no looping of wire required). Firmly tighten screw over wire.
4. Mount device with "TOP" up using long mounting screws.
5. Snap RenuTM Screw-less wallplate directly onto device strap with Leviton logo properly oriented.
6. Restore power at circuit breaker or fuse. Installation is complete. NOTE: Your device may include color options. To change color of the face see COLOR CHANGE gures.
SINGLE POLE / UNIPOLAIRE / UNIPOLAR
Load
RE151
3
2
2
2
Brass Screw
vis laiton
Tornillo de Latón
Charge
Carga
FIGURE 1 / FIGURE 1 / FIGURA 1
Top view / Vue du dessus / Vista superior
Ground Insert Hole
Orifice d’insertion
GROUND INSERT HOLE
Tab
Languette
Lengüeta
Orificio para insertar
Ground Screw
Vis de terre
Tornillo a Tierra
Conductor
Fil
Conductor
Neutral (White)
Neutre (Blanc)
Neutro (Blanco)
Line 120/277VAC, 60 Hz
Ligne 120/277 V c.a., 60 Hz
Línea 120/277VCA, 60Hz
Line Hot (Black)
Ligne actif (noir)
Linea Fase (Negro)
3
Ground (Green Screw)
Terre (vis verte)
Tierra (Tornillo Verde)
1
Black Screw
vis noire
Tornillo negro
2
Brass Screw
vis laiton
Tornillo de Latón
3
Ground (Green Screw)
Terre (vis verte)
Tierra (Tornillo Verde)
COLOR CHANGE / CHANGEMENT DE COULEUR / CAMBIO DE COLOR
TOP
TOP
Push in sides at tabs and pull to release face
Serrer les côtés au niveau des pattes pour dégager la face
Presione en los lados de las pestañas y jale para soltar la cara
Insert the bottom hinge tabs, then pivot and snap on the new face to attach
Insérer les pattes inférieures et faire basculer le haut pour l’enclencher la face
Inserte la punta de la base de las pestañas, gire y presione la cara nueva para unir
3-WAY / À TROIS VOIES / 3-VÍAS
RE153RE153
3 3
2
2
1
2
2
1
Load
Charge
Carga
Line Hot (Black)
Ligne actif (noir)
Linea Fase (Negro)
Line 120/277VAC, 60 Hz
Ligne 120/277 V c.a., 60 Hz
Línea 120/277VCA, 60Hz
Neutral (White)
Neutre (Blanc)
Neutro (Blanco)
TOP
TOP
Leviton warrants to the original consumer purchaser and not for the benet of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for ve years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such ve year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 201 North Service Road, Melville, New York 11747. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and tness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and tness for a particular purpose, is limited to ve years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment,
lost sales or prots or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only) www.leviton.com
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Loading...