Leviton’s Programmer/Remote, Cat. No. RZCPG, is a
multi-functional device. It uses Z-WaveTM technology
to act as a programmer, zone or scene controller,
remote for setting up and operating your ViziaTM
RF network. This manual will guide you through
the understanding of your RZCPG functions as a
setup controller. Once your network is installed, your
RZCPG may also be used as a wireless controller for
controlling your lighting system.
Your RZCPG comes with batteries.
RZCPG
Programmer/Remote
1
Page 4
MENU NAVIGATION and ICONS
x1
Ba ck
MAIN MENU
1. Device List
2. Who Is...
3. Area
5. Settings
4. Profile
Home
1
ON
2
ON
3
ON
4
ON
OFF
OFF
OFF
OFF
x1
Stand By
-RZCPG-
Default Profile
1. Area #1
2. Area #2
3. Area #3
4. Area #4
Menu
Menu
Menu
Navigating screens and menus on your RZCPG is
accomplished using the following buttons:
LCD
Display
(HOME screen
depicted)
Left
Soft Key
Arrow
Buttons
(up, down,
left, right)
Right
Soft Key
Center
Button
"–"
Button
From the HOME Screen, pressing buttons 1, 2, 3, 4
will control the areas displayed.
The right soft key brings
you to the MAINMENU screen
bring you back to the previous screen.
The up and down arrow buttons allow you
to scroll through each screen and will move the
selection box (
NOTE: Selections are made on
each screen by pressing the
center button on the RZCPG
unless prompted otherwise.
2
from the HOME screen and is
used for saving and completing
tasks.
The left soft key is used to
1. Device List
) to each choice.
"+"
Button
CENTER BUTTON
Page 5
x1
Back(3
)
Area #1
Who Is
Bedroom
Bathroom
Hall
selected 3
x1
12:00 PM
Mon05.01.2006
Default Profil e
Stand By
x1
BackHome
AREA
<<
NEW
>>
<<
x1
All Devices
Dimmer #1
x1
PROFILE
<<
NEW
>>
SceneZone
x1
CancelSave
All Devices
1. All Devices
2. < ON
>
3. Default Fade
x1
All Devices
< ON >
x1
12:00 PM
Mon05.01.2006
Default Profil e
Stand By
x1
12:00 PM
Mon05.01.2006
Default Profil e
Stand By
x1
Back(3
)
All Devices
Dimmer #1
Switch #1
Switch #2
selected 1
Who Is
x1
Stand By
-RZCPG-
Default Profile
1. Area #1
2. Area #2
3. Area #3
4. Area #4
Menu
x1
Area #1
x1
Back
PROFILE
<<
NEW
>>
Home
Profile #1
Profile #2
>>
appears on various
NEW
screens as a prompt to create
something new (Area, Profile,
Event, etc.)
Single brackets
designate that more than one
choice is available. Use the left
and right side arrow buttons
to toggle between
choices.
Check boxes are used
when multiple selections are
available. Use the and
buttons to select and deselect
from a list.
Radio buttons are used
when an "either/or" single choice
is available. Scroll the selection
box to your choice and use the
button to select.
The Filter is used when
you wish to view only checked
devices, or only unchecked
devices from a list. Use the
right arrow button to toggle
between showing devices
checked, unchecked or all (no
filter).
Leviton also provides various icons that appear on
the screens to provide quick review of the state
of your network, selections made and to assist in
identification of devices (refer to Icon Description
chart).
3
Page 6
DESCRIPTION
Undefined device
Center button
Remote Control
Zone/Scene Controller (Single or Multibutton)
Dimmer
Switch
Thermostat
Buzzer OFF (indication)
Buzzer OFF
Buzzer ON
Error Indication
Filter (data on screen is filtered)
Battery Power
Single choice (radio button) - not chosen
Single choice (radio button) - chosen
Multiple selection (checkbox) - not selected
Multiple selection (checkbox) - selected
ICON
Certified
Z-Wave Compliant
by
x1
NO
INSTALL CHECKLIST
YES
START
INSTALLATION
CHECKLIST
Upon initial power up of the RZCPG, the VIZIATMRF
logo will appear briefly. You will then be prompted to
START INSTALLATION CHECKLIST. Press the right
soft key (YES) to begin Installation Checklist.
STARTUP
4
Page 7
INSTALLATION CHECKLIST
x1
Back
INSTALL CHECKLIST
1. Include Dim/Swch
2. Include Controller
3. Update Controller
4. Create Areas
5. Set Associations
Next Step
x1
Back
3.
Update Controller
4. Create Areas
5. Set Associations
6. Security
7. Install Complete
Next Step
INSTALL CHECKLIST
x1
Cancel
INCLUDE DIM/SWCH
Press button on
Dimmer/Switch
Leviton provides the Installation Checklist as a step
by step tool to setup your ViziaTMRF network and
recommends following these steps in order, specifically
if you are a first time user. System design will impact
performance, so it is necessary to include and update
your devices in a specific order to ensure overall system
performance and reliability. The Installation Checklist
steps are shown below. When a step is completed,
simply press the right soft key to select NEXT STEP
and the RZCPG will bring you to the next screen.
Using your RZCPG, follow these steps to set up
your ViziaRF
STEP 1
TM
network:
Include Dimmers/Switches
Pressing the center button
to select Include Dim/Swch
will bring you to the INCLUDE
DIM/SWCH
RZCPG into Inclusion Mode.
screen and put the
You will be prompted to press a
button on your Dimmer, Switch or
Plug-In Module. These devices
require a simple one step process (button press) to
include into the network (refer to individual device instruction sheet). Once the button is pressed on
your Dimmer, Switch or Plug-In Module, the RZCPG
will go through a communication process and assign
the node information for that device. The TEXT
EDITOR will display. You can now name your
NOTE: The RZCPG is by default assigned #1.
device.
5
Page 8
x1
TEXT EDITOR
Switch #2
Levito
Save? Press
n
Switch #2
Template
TEXT EDITOR
x1
BackNext Step
Node included!
Node ID# 2:
Bedroom
More? Press
INCLUDE DIM/SWCH
x1
TEXT EDITOR
Switch #2
Leviton
Bedroom
Abc
Save? Press
x1
Back
INSTALL CHECKLIST
1. Include Dim/Swch
2. Include Controller
3. Update Controller
4. Create Areas
5. Set Associations
Next Step
Menu
Menu
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
x1
Stand By
-RZCPG-
Default Profile
1. Area #1
2. Area #2
3. Area #3
4. Area #4
Menu
Menu
Menu
Using TEXT EDITOR you can
either assign a name from a list
of templates or assign a unique
name to your device.
NOTE: The right soft key will
toggle from Template to Abc to
ABC to abc to 123 and back to
Template again. This feature allows you to access
the template names or to select capital/undercase
letters and numerals to name your device.
To use the pre-made Templates,
with Template displayed, use the
up and down arrow buttons
to select a name. The RZCPG
offers a list of over 100 commonly
used names to choose from.
NOTE: The template names are
editable for customization if you
choose to alter them.
To create a unique name or modify text, under
ABC (or Abc, abc, 123) use the up and down arrow
buttons to change each letter or numeral and
side arrow buttons to navigate. The and
buttons can be used to insert and delete characters.
Once your template or created
name is displayed, press the
center button .Your device
has now been included in
the network with your chosen
name. The RZCPG will confirm
inclusion with the name displayed
and prompt you to continue to
INCLUDE DIM/SWCH
or to continue to the NEXT STEP by pressing the
right soft key .
STEP 2
NOTE: The INSTALL CHECKLIST
screen will appear with the
selection box around STEP 2
- Include Controller when NEXT
STEP is chosen from STEP 1.
6
Include Controller
by pressing the center button
Page 9
Press the center button on the
x1
Return
INCLUDE CNTRLLER
Place controller
in program mode
See Instruction sheet
Begin? Press
x1
BackNext Step
Node included!
Node ID #3:
Room Controller
INCLUDE CNTRLLER
More? Press
x1
Back
INSTALL CHECKLIST
1. Include Dim/Swch
2. Include Controller
3. Update Controller
4. Create Areas
5. Set Associations
Next Step
x1
Back(2)Who Is
UPDATE CNTRLS
Room Controller
Hall Controller
Menu
RZCPG to bring up the INCLUDE
CNTRLLER screen, where you will
be prompted to place the controller
in program mode.
NOTE: Leviton Controllers require
an inclusion process that differs
from Dimmers, Switches and PlugIn Modules. Controllers must be placed into program
mode before they can be included into the network
(refer to individual device instruction sheet).
NOTE: If no controllers are in system, use down arrow
button to skip to STEP 4.
Once your controller has been placed in program
mode, press the center button on the RZCPG. The
RZCPG will go through the communication process
and assign the node information for that device. The TEXT EDITOR will display where you can name your
device (refer to TEXT EDITOR pg. 6).
Once your name is displayed,
press the center button .The
RZCPG will confirm inclusion
and prompt you to continue to
INCLUDE CONTROLLER by
pressing the center button or
to continue to the NEXT STEP
by pressing the right soft key
NOTE: The confirmation process will take some time,
specifically in large networks. Remain close to the
controller until the confirmation is complete.
STEP 3
Update Controller
NOTE: The INSTALL CHECKLIST
screen will appear with the
selection box around STEP 3
- Update Controller when NEXT
STEP is chosen from STEP 2.
Press the center button to
bring up the UPDATE CNTRLS
screen where a list of all the
controllers in the network will be
displayed. With the selection box
around the first controller listed
press the center button .
7
Page 10
The RZCPG will prompt you to
x1
NOYES
UPDATE
Please stand within
3 ft from controller
and press YES
to continue
x1
Return
UPDATE
Node Updated!
Node ID #4
Room controller
x1
Cancel
CREATE AREA
Name: Area #1
Add Devices...
Save
x1
BackNext Step
AREA
<<
NEW
>>
x1
Back
INSTALL CHECKLIST
1. Include Dim/Swch
2. Include Controller
3. Update Controller
4. Create Areas
5. Set Associations
Next Step
stand within 3 feet of that controller.
Press the right soft key (YES)
to update your controller. NOTE:
It is important that you remain
within 3 ft. of the controller
you've selected from the list.
If you are unsure about which
controller you are updating
you can use the "Who Is"
command (see pg. 13).
Leviton controllers will blink
during the update process,
confirming you are updating
the correct controller. Update
only one controller at a time.
Once the RZCPG confirms UPDATE it will display
the updated node information. Press left soft
key (Return). Continue this process until all of
your controllers have been updated. Each time
you successfully update your controller it will be
removed from the list. Once all of your controllers
have been updated, press the right soft key to
continue to the NEXT STEP.
STEP 4
Create Areas
NOTE: The INSTALL
CHECKLIST screen will appear
with the selection box around
STEP 4 - Create Areas when
NEXT STEP is chosen from
STEP 2.
Press the center button to
bring up the AREA screen. With
<<
>>
NEW
selected press the
center button to bring up the
CREATE AREA screen. You
can now name your new area
by pressing the center button
(refer to TEXT EDITOR pg. 6).
Once you name your new area,
press the center button to
save the information and return
to the CREATE AREA screen.
8
Page 11
Scroll to and press the center
x1
Back(3
)
AREA #1
Bedroom
Bathroom
Hall
selected 1
Who Is
x1
BackNext Step
AREA
<<
NEW
>>
Area #1
x1
Stand By
-RZCPG-
Default Profile
1. Area #1
2. Area #2
3. Area #3
4. Area #4
Menu
4
ON
OFF
OFF
x1
Back
ASSOCIATION
Room Controller
Hall Controller
Den Controller
Next Step
x1
Back
INSTALL CHECKLIST
1. Include Dim/Swch
2. Include Controller
3. Update Controller
4. Create Areas
5. Set Associations
Next Step
1
ON
OFF
OFF
Menu
button to select Add Devices
which will bring up a list of the
dimmers and switches you
included in Step 1 to add to your
new area. Scroll to each device
check box and use the and
buttons to either add or subtract
each device from your area.
NOTE: You can use the
4 ON button on the bottom
of the RZCPG to select ALL
devices simultaneously. The 4
button deselects ALL
OFF
devices. This feature will work
whenever you encounter check
box lists.
Once you have checked the devices for your area
press the right soft key (Save). The AREA screen
will display with your newly created area and prompt
you to continue to create a new area by pressing the
center button to select
to the NEXT STEP by pressing the right soft key .
<<
NEW
>>
NOTE: You can use the 1 ON button and
button on the RZCPG to turn the lights
1 OFF
ON and OFF in an area that has the selection box
around it.
STEP 5
Set Associations
NOTE: The INSTALL CHECKLIST
screen will appear with the
selection box around STEP 5 -Set Associations when NEXT STEP is
chosen from STEP 4.
NOTE: If no controllers are in
system, use down arrow button
to skip to STEP 6.
Press the center button to bring
up the ASSOCIATION screen.
A list of controllers included in
Step 2 that support association will
be displayed.
Scroll to and press the center
button to select the controller
you wish to
associate an area or areas to.
or to continue
9
Page 12
The CONTROLLER ASSOC
x1
Back
SECURITY
1. Setup Password
2. < OPEN
>
Save
x1
Back
SECURITY
1. Setup Password
2. < RZCPG Lock
>
Save
x1
Back
2.
Include Controller
3. Update Controller
4. Create Areas
5. Set Associations
6. Security
Next Step
INSTALL CHECKLIST
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
x1
Cancel
CONTROLLER ASSOC
Dev: Room Controller
1. < Button 1
>
2. Area #1
3. Area ON/OFF
Save
screen will display with the
selection box around 1. Button
prompting you to select the
button on your controller that
you wish to associate an area to.
Use side arrow buttons to
toggle if applicable.
Scroll to 2. Area and choose an area you wish to
associate to the button you've selected. This will
allow the button on the chosen controller to control
the desired area.
Selecting 3. Area ON/OFF allows you to set an
AREA ON/OFF
on your controller (for SCENE commands refer to
or SCENE command to that button
Advanced Settings).
Once you are done press the right soft key
(Save) to complete. You will be prompted to
continue setting associations or to proceed to the
NEXT STEP
STEP 6
by pressing the right soft key .
Security
NOTE: The INSTALL
CHECKLIST screen will appear
with the selection box around
STEP 6 - Security when NEXT
STEP is chosen from STEP 5.
Press the center button to
bring up the SECURITY screen.
Press the center button to
select 1.Setup Password.
Enter password using four of the
eight buttons on the RZCPG
(1 ON, 1 OFF, 2 ON, 2 OFF etc.)
NOTE: The password you
choose MUSTbe4 characters
long.
You will be prompted to, and
must re-enter password.
Scroll to 2. and use the side
arrow buttons to toggle
between choices OPEN, RZCPG Lock and System Lock.
10
Page 13
Press right soft key (Save) to complete.
x1
INSTALL CHECKLIST
Installation Checklist
complete.
Press
button
to start using RZCPG.
x1
Stand By
-RZCPG-
Default Profile
1. Area #1
2. Area #2
3. Area #3
4. Area #4
Menu
x1
Back
3.
Update Controller
4. Create Areas
5. Set Associations
6. Security
7. Install Complete
Next Step
INSTALL CHECKLIST
NOTE: Selecting <RZCPG Lock> will lock the
RZCPG. When you return to the HOME screen you
will not have access to the MAIN MENU nor any
screens until you press the right soft key and
enter your password.
Selecting <System Lock> will only lock System
Setup, preventing one from changing how the
system is configured until the password is entered
upon prompt.
STEP 7
Install Complete
NOTE: The INSTALL
CHECKLIST screen will appear
with the selection box around
STEP 7 -Install Complete when
you save your security selection.
Press the center button to
receive your confirmation that
the INSTALL CHECKLIST is
now complete. Press the center
button again to start using
the RZCPG.
The HOME screen of the
RZCPG will be displayed.
11
Page 14
MAIN MENU SCREEN
x1
Ba ck
MAIN MENU
1. Device List
2. Who Is
3. Area
4. Profile
5. Settings
Home
x1
Ba ck
MAIN MENU
2. Who Is
3. Area
4. Profile
5. Settings
Home
6. System Setup
x1
Back
WHO IS...
Press button on unit
Acquiring node info
x1
Back
WHO IS...
This is node #7
Dimmer Scene Cap
RT Slave
Name: Hall dimmer
Press
x1
Ba ck (8
)
DEVICE LIST
Who Is
Bedroom
Bathroom
Hall
RZCPG
R
C
Room Controller
OFF
x1
Stand By
-RZCPG-
Default Profile
1. Area #1
2. Area #2
3. Area #3
4. Area #4
Menu
Pressing the right soft key while on the HOME
screen will bring up the MAINMENU screen where
you can navigate through the various selections to
edit or change settings.
DEVICE LIST
Selecting 1. Device List from the
MENU screen will bring you to
the DEVICE LIST screen where
a list devices included in the
network will appear. From this
list you can rename devices by
pressing the center button to
select a device and using TEXT EDITOR (pg.6), control ON/OFF and adjust intensity
levels. NOTE: Pressing the 2 OFF button with
the selection box around a dimming device will
bring up the DEVICE CONTROL menu where you
can use the and buttons to precisely raise
or lower the level with slide control, which will be
displayed at the bottom.
WHO IS
Selecting 2. Who Is from the
MENU screen will bring you to
the WHO IS... screen where you
can identify your devices. Simply
press a button on a network
included device to obtain the node
information.
After the information is received
by the RZCPG, it will display the
device ID and the NAME assigned
to the device you activated.
12
Page 15
AREA
1
ON
OFF
4
ON
OFF
x1
Back
PROFILE
<<
NEW
>>
Home
x1
Cancel
NEW PROFILE
Name: Profile #1
Save
Button: 1
Area: Area #1
Action: ON/OFF
x1
Back
PROFILE
<<
NEW
>>
Home
Profile #1
Profile #2
Profile #3
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Selecting 3. Area from the MENU screen will bring
you to the AREA screen. You can create a new
area, rename an existing area, modify devices
in an area or delete an area (refer to Step 4 of
INSTALLATION CHECKLIST - Create Areas pg.9).
PROFILE
Selecting 4. Profile from the MENU screen will bring
you to the PROFILE screen. Up to 16 profiles can
be created to control different areas of your house
with your RZCPG. Each device may be controlled by
assigning an area to one of the four buttons on the
RZCPG. NOTE: Default profile will control the first
four areas created with ON/OFF control using the 1
ON , 1 OFF
4 OFF
buttons respectively.
With the selection box around
<<
>>
NEW
button . You can name your
new profile by pressing the center
button to select Name:(refer
to TEXT EDITOR pg. 6).
Once you name your new profile,
press the center button to
save and scroll to Button. Use
side arrow buttons to
toggle between button choices.
The displayed button will be the
button on your controller that
your profile will react to.
Scroll to Area and use side arrow
buttons to choose the area
you wish to affect with this profile.
Scroll to Action and use side
arrow buttons to choose
an ON/OFF or SCENE (1-255)
command. Scene commands will
also give you a Fade option. Use
side arrow buttons to toggle
between fade choices DEFAULT,
IMMEDIATE, or 1 SECOND thru
127 MINUTES.
Press the right soft key (Save) to complete.
through 4 ON ,
press the center
13
Page 16
The HOME screen will display
x1
Stand By
-RZCPG-
Default Profile
1. Area #1
2. Area #2
3. Area #3
4. Area #4
Menu
x1
Stand By
-RZCPG-
Default Profile
1. Area #1
2. Area #2
3. Area #3
4. Area #4
Menu
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
x1
Ba ck
SETTINGS
1. Contrast
2. Buzzer
3. Security
4. Battery Level
Home
x1
Cancel
BUZZER
Save
Buzzer ON
x1
Cancel
CONTRAST
Save
050 %
x1
Stand By
-RZCPG-
Default Profile
1. Area #1
2. Area #2
3. Area #3
4. Area #4
Menu
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
with your newly created profile.
Use the side arrow buttons
to toggle between profiles when
on the HOME screen. Default Profile will display when none
are selected. Use the button
to deselect a profile.
SETTINGS
Selecting 5. Settings from the
MAIN MENU screen will bring you to the SETTINGS screen.
CONTRAST
Sets the contrast for your
RZCPG LCD screen as follows:
1. Select Contrast.
2. Use the and
buttons to adjust
the percentage of contrast.
3. Press right soft key
(Save) to complete.
BUZZER
Turns the buzzer on the RZCPG keypad ON or
. When the buzzer is ON, a beep will be heard
OFF
when pressing the keypad. When the buzzer
is OFF, a click will be heard when pressing the
keypad. The default setting is buzzer ON. Adjust the
buzzer as follows:
1. Select Buzzer.
2. Use the side arrow
buttons to turn buzzer ON
or OFF.
3. Press right soft key
14
(Save) to complete.
Page 17
SECURITY
x1
Back
BATTERY LEVEL
Home
- 2.88 +
x1
Back
SYSTEM SETUP
1. Install Checklist
2. Advanced
Home
x1
NO
ADVANCED
Advanced
Settings?
YES
Sets the password and lock level for your RZCPG
or System (refer to INSTALLATION CHECKLIST
- Security pg. 11).
BATTERY LEVEL
Displays the battery level for your
RZCPG as follows:
1. Select Battery Level.
SYSTEM SETUP
Selecting 7. System Setup
from the MAIN MENU screen
will bring you to the SYSTEM SETUP screen.
Selecting 1. Install Checklist
brings you to the Installation
Checklist (refer to pg. 5).
NOTE: This feature is not
available on secondary remotes.
Selecting 2. Advanced will
prompt you to continue with
Advanced Settings. Pressing
the right soft key (YES) will
bring you to the ADVANCED
screen.
NOTE: If you are unsure about any of the
following ADVANCED SETTINGS consult
ViziaRF application guide or visit our
website at www.ViziaRF.com.
15
Page 18
x1
Back
ADVANCED
1. Network
2. Association
3. HAI Setup
4. RTS Devices
5. Utilities
Home
x1
Back
NETWORK
1. Include Node
2. Exclude Node
3.
Ntwk Rediscovery
4. Update Devices
5. Remove Failed
Home
x1
Back
NETWORK
5. Remove Failed
6. Join Network
7. RZCPG Utils
8. Replace Node
9. Dev Properties
Home
NETWORK
x1
BackHome
NTWK REDISCOVERY
Powerlevel -6DB
To change powerlevel
press [4 OFF
]
Start? Press
x1
Cancel
FAILED NODE
Building Node List
Complete...65%
x1
Ba ck
REMOVE FAILED
Home
Bedroom
Bathroom
Hall
Room Controller
Selecting 1. Network from the ADVANCED screen
will bring you to the NETWORK screen.
1. Include Node
(refer to INSTALLATION CHECKLIST pg. 5)
2. Exclude Node
Use this option to remove a device from the
network (refer to the individual device
instruction sheet for details).
3. Network Rediscovery
This feature is used for updating your network,
specifically if nodes have moved or the network
environment has changed.
It will optimize the mesh
network to ensure overall
system routing integrity.
4. Update Controllers
(refer to INSTALLATION
CHECKLIST - Update
Controllers pg. 8).
5. Remove Failed
Use this option to detect
devices that are nonoperational and require
removal from the network.
Once the list is generated, you
will press the center button
to select a device to
remove. Press the right soft
key (YES) to remove the
device from the network.
6. Join as Secondary
This feature allows you to
join this Leviton RZCPG
16
Page 19
as a secondary remote to
x1
NOYES
JOIN AS SECONDARY
WARNING!
This step will erase
all the data
Continue?
x1
NO
REMOVE FAILED
YES
Bedroom
Node 2
Remove?
x2
NOYES
JOIN AS SECONDARY
Would you like
to start building
node list?
x1
BackHome
RZCPG UTILS
1.
Get Data
2.
Send Data
3.
Update DB (Man)
4.
Update DB (Aut)
x1
BackHome
TX DATA
When prompted
on receiving unit
press one of the
group buttons
the network. Press the right
soft key (YES) after the
prompt to continue. NOTE:
This step will erase any
existing data in the remote.
You will then be required to
include this remote with your
primary controller. Follow
the controller inclusion/
replication process of
your primary controller
(for RZCPG see pg. 7). This
secondary remote will prompt
you to start building the
node list. Press right soft key
(YES) to complete.
A confirmation (version) screen
will display the same Home ID
as the primary, a new Node
ID, a new serial number and
an x2 designation at the top.
NOTE: The secondary remote will be populated
with only the device data of the primary remote
(not Areas, Profiles). You can create new Areas
and Profiles with your secondary remote. If you
wish to duplicate the secondary RZCPG remote
with the primary RZCPG remote's application
information, use RZCPG Utilities.
7. RZCPG Utilities
This feature allows you
to duplicate all necessary
network data from a primary
RZCPG remote into your
secondary RZCPG remotes.
1.Get Data is selected from
the receiving RZCPG
remote to retrieve the
selected data (Areas,
Profiles,) from the sending
RZCPG remote.
2.SEND data is selected
from the primary RZCPG
remote to transfer the
17
Page 20
data. Follow the prompts to
x1
Cancel
FAILED NODE
Building Node List
Complete...65%
x1
Ba ck
REPLACE NODE
Home
Bedroom
Bathroom
Hall
Room Controller
x1
Ba ck
REPLACE NODE
Home
Prepare replacing
controller or press
button on slave
when prompted
Start? Press
x1
BackNext Step
Node replaced!
Node ID# 8:
Garage
More? Press
REPLACE NODE
x1
BackHome
RX DATA
Setup Data
Areas
Profiles
Start? Press
Select receive items
complete this process.
NOTE: Update DB (no. 3
and 4) are only available on
secondary RZCPG remotes.
3. Update DB (Man) is used
to manually perform a
database update (devices in the network, their
names and types) for a secondary remote that
has joined the network. It will require you to
press buttons on each individual device you
wish to update in your secondary remote.
4.Update DB (Aut) is used to perform an
automatic database update (devices in
the network, their names and types) for a
secondary remote that has joined the network.
8. Replace Node
Use this option to replace
non-operational devices in
the network. Once the list is
generated, you will press the
center button to select
a device to replace. You will
be prompted to prepare the
controller to be replaced or
to press a button on a slave
device to be replaced when
prompted. The button press
will occur after you initiate
the replacement process by
pressing the center button
on the RZCPG. After
replacement you can name the replacing device
(refer to TEXT EDITOR
pg. 6). Once your name is saved, you will receive
confirmation that the node has been replaced.
18
Page 21
x1
Back
ASSOCIATION
Room Controller
Hall Controller
Den Controller
Home
x1
Back(4
)
PROPERTIES
RZCPG
R
C
Bedroom
Hall
Home
Room Controller
x1
Back
PROPERTY
Name: RZCPG
NID: 001 Cntrl Room
Portable Remote
Home
Mfg. by Leviton
9. Device Properties
x1
Back
RTS DEVICES
1. Set Routes
2. Set Hail
3. Update Routes
Home
x1
Back(3
)
HAI SETUP
Home
Bedroom
Hall
Room Controller
This feature will display information about
a particular device (Name, Node ID and Description) when selected from the list.
Selecting 2. Association from
the ADVANCED screen will
bring you to the ASSOCIATION
screen. NOTE: Consult ViziaRF
application guide for advanced
ASSOCIATION options.
Selecting 3. HAI Setup from
the ADVANCED screen will
bring you to the HAI SETUP
screen. This feature allows for
the creation of subscriptions
for devices when setting up a
PC interface (refer to ViziaRF application guide).
Selecting 4. RTS Devices from
the ADVANCED screen will
bring you to the RTS DEVICES
screen. This is a network
optimization feature which can
enhance performance and
communication ability (refer to
ViziaRF application guide).
ASSOCIATION
HAI SETUP
RTS DEVICES
19
Page 22
UTILITIES
x1
BackHome
UTILITIES
1. Who Is
2. Version
3. Rediscovery
4. Dev Properties
5. Reset
x1
BackHome
UTILITIES
3. Rediscovery
4. Device Property
5. Reset
6. Test ZW
7. Test CR
x1
Back
VIZIA RF V1.09
Z-Wave 2.06
Dec 7 2006
HID: 00989680
NID: 1
S/N: 007358DH
Menu
x1
Cancel
Save
REDISCOVERY PL
-3 DB
+/– to adjust
x1
RESET
ALL DATA
WILL BE
LOST
PROCEED?
NOYES
Selecting 5. Utilities from the ADVANCED screen
will bring you to the UTILITIES screen.
1. Who Is...
(refer to WHO Is... pg.13).
2. Version
This feature displays the
ViziaTMRF and Z-WaveTM
versions, the Home ID, Node
ID and Serial No. of your
RZCPG. You can also access
this screen by pressing the up arrow button
while on the HOME screen.
3. Rediscovery PL
This feature allows you to
change the power level used for
network rediscovery (refer to
Network Rediscovery pg. 19).
4. Device Properties
(refer to Device Properties
pg. 22).
5. Reset
Resets your RZCPG back to
factory default and erases any
programmed information from
the remote. NOTE: Resetting
the RZCPG to factory default
does not reset your devices. If you want to
factory reset your devices refer to the individual
device instruction sheet for that device.
6. Test ZW
WARNING: For factory use only! DO NOT USE.
7. Test CR
WARNING: For factory use only! DO NOT USE.
20
Page 23
NOTES
Page 24
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and
not for the benefit of anyone else that this product at the
time of its sale by Leviton is free of defects in materials
and workmanship under normal and proper use for five
years from the purchase date. Leviton’s only obligation
is to correct such defects by repair or replacement, at
its option, if within such five year period the product is
returned prepaid, with proof of purchase date, and a
description of the problem to Leviton Manufacturing
Co., Inc., Att: Quality Assurance Department, 59-25
Little Neck Parkway, Little Neck, New York 11362-2591.
This warranty excludes and there is disclaimed liability
for labor for removal of this product or reinstallation. This
warranty is void if this product is installed improperly or in
an improper environment, overloaded, misused, opened,
abused, or altered in any manner, or is not used under
normal operating conditions or not in accordance with
any labels or instructions. There are no other or implied
warranties of any kind, including merchantability
and fitness for a particular purpose, but if any implied
warranty is required by the applicable jurisdiction,
the duration of any such implied warranty, including
merchantability and fitness for a particular purpose, is
limited to five years. Leviton is not liable for incidental,
indirect, special, or consequential damages, including