Leviton Programmer Remote User Manual

Page 1
Programmer/Remote
Compatible with enabled products!
TM
1
O
N
2
O
N
3
O
N
4
O
N
+
O
F
F
O
F
F
O
F
F
O
F
F
Cat. RZCPG
USER GUIDE
Page 2
TABLE OF CONTENTS
INTRODUCTION .......................................................1
MENU NAVIGATION & ICONS .............................2–4
STARTUP...................................................................4
INSTALLATION CHECKLIST ...................................5
Include Dimmers/Switches ....................................5
TEXT EDITOR .......................................................6
Include Controller ...........................................6, 7
Update Controller ............................................7, 8
Create Areas ....................................................8, 9
Set Associations ...........................................9, 10
Security ........................................................10, 11
Install Complete.................................................11
MAIN MENU SCREEN ............................................12
DEVICE LIST ...........................................................12
WHO IS.. .............................................................12
AREA ..................................................................13
PROFILE .......................................................13, 14
SETTINGS ..........................................................14
CONTRAST ....................................................14
BUZZER .........................................................14
SECURITY ......................................................15
BATTERY LEVEL ...........................................15
SYSTEM SETUP (Advanced Settings) ............15
NETWORK ...............................................16–19
ASSOCIATION ...............................................19
HAI SETUP ....................................................19
RTS DEVICES ...............................................19
UTILITIES .......................................................20
Page 3
INTRODUCTION
1
O
N
2
O
N
3
O
N
4
O
N
+
O
F
F
O
F
F
O
F
F
O
F
F
Leviton’s Programmer/Remote, Cat. No. RZCPG, is a multi-functional device. It uses Z-WaveTM technology to act as a programmer, zone or scene controller, remote for setting up and operating your ViziaTM RF network. This manual will guide you through the understanding of your RZCPG functions as a setup controller. Once your network is installed, your RZCPG may also be used as a wireless controller for controlling your lighting system.
Your RZCPG comes with batteries.
RZCPG
Programmer/Remote
1
Page 4
MENU NAVIGATION and ICONS
x1
Ba ck
MAIN MENU
1. Device List
2. Who Is...
3. Area
5. Settings
4. Profile
Home
1
ON
2
ON
3
ON
4
ON
OFF
OFF
OFF
OFF
x1
Stand By
-RZCPG-
Default Profile
1. Area #1
2. Area #2
3. Area #3
4. Area #4
Menu
Menu
Menu
Navigating screens and menus on your RZCPG is accomplished using the following buttons:
LCD Display
(HOME screen depicted)
Left
Soft Key
Arrow
Buttons
(up, down,
left, right)
Right Soft Key
Center Button
"–"
Button
From the HOME Screen, pressing buttons 1, 2, 3, 4 will control the areas displayed.
The right soft key brings you to the MAIN MENU screen
bring you back to the previous screen.
The up and down arrow buttons allow you to scroll through each screen and will move the
selection box (
NOTE: Selections are made on
each screen by pressing the center button on the RZCPG unless prompted otherwise.
2
from the HOME screen and is used for saving and completing tasks.
The left soft key is used to
1. Device List
) to each choice.
"+" Button
CENTER BUTTON
Page 5
x1
Back(3
)
Area #1
Who Is
Bedroom Bathroom Hall
selected 3
x1
12:00 PM
Mo n 05. 01.2 00 6
Default Pr ofil e
Stand By
x1
Back Home
AREA
<<
NEW
>>
<<
x1
All Devices
Dimmer #1
x1
PROFILE
<<
NEW
>>
Scene Zone
x1
Cancel Save
All Devices
1. All Devices
2. < ON
>
3. Default Fade
x1
All Devices
< ON >
x1
12:00 PM
Mon 05.01.200 6
Default Pr ofil e
Stand By
x1
12:00 PM
Mon 05.01.200 6
Default Pr ofil e
Stand By
x1
Back(3
)
All Devices
Dimmer #1 Switch #1 Switch #2
selected 1
Who Is
x1
Stand By
-RZCPG-
Default Profile
1. Area #1
2. Area #2
3. Area #3
4. Area #4
Menu
x1
Area #1
x1
Back
PROFILE
<<
NEW
>>
Home
Profile #1 Profile #2
>>
appears on various
NEW
screens as a prompt to create something new (Area, Profile,
Event, etc.)
Single brackets
designate that more than one choice is available. Use the left and right side arrow buttons
to toggle between choices.
Check boxes are used when multiple selections are available. Use the and buttons to select and deselect from a list.
Radio buttons are used when an "either/or" single choice is available. Scroll the selection box to your choice and use the
button to select.
The Filter is used when you wish to view only checked devices, or only unchecked devices from a list. Use the right arrow button to toggle between showing devices checked, unchecked or all (no filter).
Leviton also provides various icons that appear on the screens to provide quick review of the state of your network, selections made and to assist in identification of devices (refer to Icon Description
chart).
3
Page 6
DESCRIPTION
Undefined device
Center button
Remote Control
Zone/Scene Controller (Single or Multibutton)
Dimmer
Switch
Thermostat
Buzzer OFF (indication)
Buzzer OFF
Buzzer ON
Error Indication
Filter (data on screen is filtered)
Battery Power
Single choice (radio button) - not chosen
Single choice (radio button) - chosen
Multiple selection (checkbox) - not selected
Multiple selection (checkbox) - selected
ICON
Certified
Z-Wave Compliant
by
x1
NO
INSTALL CHECKLIST
YES
START
INSTALLATION
CHECKLIST
Upon initial power up of the RZCPG, the VIZIATMRF logo will appear briefly. You will then be prompted to START INSTALLATION CHECKLIST. Press the right soft key (YES) to begin Installation Checklist.
STARTUP
4
Page 7
INSTALLATION CHECKLIST
x1
Back
INSTALL CHECKLIST
1. Include Dim/Swch
2. Include Controller
3. Update Controller
4. Create Areas
5. Set Associations
Next Step
x1
Back
3.
Update Controller
4. Create Areas
5. Set Associations
6. Security
7. Install Complete
Next Step
INSTALL CHECKLIST
x1
Cancel
INCLUDE DIM/SWCH
Press button on Dimmer/Switch
Leviton provides the Installation Checklist as a step by step tool to setup your ViziaTMRF network and recommends following these steps in order, specifically if you are a first time user. System design will impact performance, so it is necessary to include and update your devices in a specific order to ensure overall system performance and reliability. The Installation Checklist steps are shown below. When a step is completed, simply press the right soft key to select NEXT STEP and the RZCPG will bring you to the next screen.
Using your RZCPG, follow these steps to set up your ViziaRF
STEP 1
TM
network:
Include Dimmers/Switches
Pressing the center button to select Include Dim/Swch will bring you to the INCLUDE
DIM/SWCH
RZCPG into Inclusion Mode.
screen and put the
You will be prompted to press a button on your Dimmer, Switch or Plug-In Module. These devices require a simple one step process (button press) to include into the network (refer to individual device instruction sheet). Once the button is pressed on your Dimmer, Switch or Plug-In Module, the RZCPG will go through a communication process and assign the node information for that device. The TEXT
EDITOR will display. You can now name your NOTE: The RZCPG is by default assigned #1.
device.
5
Page 8
x1
TEXT EDITOR
Switch #2 Levito
Save? Press
n
Switch #2
Template
TEXT EDITOR
x1
Back Next Step
Node included! Node ID# 2: Bedroom
More? Press
INCLUDE DIM/SWCH
x1
TEXT EDITOR
Switch #2 Leviton
Bedroom
Abc
Save? Press
x1
Back
INSTALL CHECKLIST
1. Include Dim/Swch
2. Include Controller
3. Update Controller
4. Create Areas
5. Set Associations
Next Step
Menu
Menu
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
x1
Stand By
-RZCPG-
Default Profile
1. Area #1
2. Area #2
3. Area #3
4. Area #4
Menu
Menu
Menu
Using TEXT EDITOR you can either assign a name from a list of templates or assign a unique name to your device.
NOTE: The right soft key will toggle from Template to Abc to
ABC to abc to 123 and back to Template again. This feature allows you to access
the template names or to select capital/undercase letters and numerals to name your device.
To use the pre-made Templates,
with Template displayed, use the up and down arrow buttons to select a name. The RZCPG offers a list of over 100 commonly used names to choose from. NOTE: The template names are editable for customization if you choose to alter them.
To create a unique name or modify text, under ABC (or Abc, abc, 123) use the up and down arrow
buttons to change each letter or numeral and side arrow buttons to navigate. The and buttons can be used to insert and delete characters.
Once your template or created name is displayed, press the center button .Your device has now been included in the network with your chosen name. The RZCPG will confirm inclusion with the name displayed and prompt you to continue to
INCLUDE DIM/SWCH
or to continue to the NEXT STEP by pressing the
right soft key .
STEP 2
NOTE: The INSTALL CHECKLIST
screen will appear with the selection box around STEP 2
- Include Controller when NEXT STEP is chosen from STEP 1.
6
Include Controller
by pressing the center button
Page 9
Press the center button on the
x1
Return
INCLUDE CNTRLLER
Place controller in program mode See Instruction sheet
Begin? Press
x1
Back Next Step
Node included! Node ID #3: Room Controller
INCLUDE CNTRLLER
More? Press
x1
Back
INSTALL CHECKLIST
1. Include Dim/Swch
2. Include Controller
3. Update Controller
4. Create Areas
5. Set Associations
Next Step
x1
Back(2)Who Is
UPDATE CNTRLS
Room Controller
Hall Controller
Menu
RZCPG to bring up the INCLUDE CNTRLLER screen, where you will
be prompted to place the controller in program mode.
NOTE: Leviton Controllers require an inclusion process that differs from Dimmers, Switches and Plug­In Modules. Controllers must be placed into program mode before they can be included into the network
(refer to individual device instruction sheet). NOTE: If no controllers are in system, use down arrow
button to skip to STEP 4. Once your controller has been placed in program
mode, press the center button on the RZCPG. The RZCPG will go through the communication process and assign the node information for that device. The TEXT EDITOR will display where you can name your device (refer to TEXT EDITOR pg. 6).
Once your name is displayed, press the center button .The RZCPG will confirm inclusion and prompt you to continue to INCLUDE CONTROLLER by pressing the center button or to continue to the NEXT STEP by pressing the right soft key NOTE: The confirmation process will take some time, specifically in large networks. Remain close to the controller until the confirmation is complete.
STEP 3
Update Controller
NOTE: The INSTALL CHECKLIST
screen will appear with the selection box around STEP 3
- Update Controller when NEXT STEP is chosen from STEP 2.
Press the center button to bring up the UPDATE CNTRLS screen where a list of all the controllers in the network will be displayed. With the selection box around the first controller listed press the center button .
7
Page 10
The RZCPG will prompt you to
x1
NO YES
UPDATE
Please stand within 3 ft from controller and press YES to continue
x1
Return
UPDATE
Node Updated! Node ID #4 Room controller
x1
Cancel
CREATE AREA
Name: Area #1 Add Devices...
Save
x1
Back Next Step
AREA
<<
NEW
>>
x1
Back
INSTALL CHECKLIST
1. Include Dim/Swch
2. Include Controller
3. Update Controller
4. Create Areas
5. Set Associations
Next Step
stand within 3 feet of that controller. Press the right soft key (YES) to update your controller. NOTE:
It is important that you remain within 3 ft. of the controller you've selected from the list. If you are unsure about which controller you are updating you can use the "Who Is" command (see pg. 13). Leviton controllers will blink during the update process, confirming you are updating the correct controller. Update only one controller at a time.
Once the RZCPG confirms UPDATE it will display the updated node information. Press left soft key (Return). Continue this process until all of your controllers have been updated. Each time you successfully update your controller it will be removed from the list. Once all of your controllers have been updated, press the right soft key to continue to the NEXT STEP.
STEP 4
Create Areas
NOTE: The INSTALL CHECKLIST screen will appear
with the selection box around
STEP 4 - Create Areas when NEXT STEP is chosen from STEP 2.
Press the center button to bring up the AREA screen. With
<<
>>
NEW
selected press the center button to bring up the CREATE AREA screen. You can now name your new area by pressing the center button
(refer to TEXT EDITOR pg. 6).
Once you name your new area, press the center button to save the information and return to the CREATE AREA screen.
8
Page 11
Scroll to and press the center
x1
Back(3
)
AREA #1
Bedroom Bathroom Hall
selected 1
Who Is
x1
Back Next Step
AREA
<<
NEW
>>
Area #1
x1
Stand By
-RZCPG-
Default Profile
1. Area #1
2. Area #2
3. Area #3
4. Area #4
Menu
4
ON
OFF
OFF
x1
Back
ASSOCIATION
Room Controller Hall Controller Den Controller
Next Step
x1
Back
INSTALL CHECKLIST
1. Include Dim/Swch
2. Include Controller
3. Update Controller
4. Create Areas
5. Set Associations
Next Step
1
ON
OFF
OFF
Menu
button to select Add Devices which will bring up a list of the dimmers and switches you included in Step 1 to add to your new area. Scroll to each device check box and use the and buttons to either add or subtract each device from your area.
NOTE: You can use the 4 ON button on the bottom
of the RZCPG to select ALL devices simultaneously. The 4
button deselects ALL
OFF
devices. This feature will work whenever you encounter check box lists. Once you have checked the devices for your area press the right soft key (Save). The AREA screen will display with your newly created area and prompt you to continue to create a new area by pressing the center button to select to the NEXT STEP by pressing the right soft key .
<<
NEW
>>
NOTE: You can use the 1 ON button and
button on the RZCPG to turn the lights
1 OFF
ON and OFF in an area that has the selection box around it.
STEP 5
Set Associations
NOTE: The INSTALL CHECKLIST
screen will appear with the selection box around STEP 5 - Set Associations when NEXT STEP is chosen from STEP 4.
NOTE: If no controllers are in system, use down arrow button to skip to STEP 6.
Press the center button to bring up the ASSOCIATION screen. A list of controllers included in Step 2 that support association will be displayed.
Scroll to and press the center button to select the controller you wish to
associate an area or areas to.
or to continue
9
Page 12
The CONTROLLER ASSOC
x1
Back
SECURITY
1. Setup Password
2. < OPEN
>
Save
x1
Back
SECURITY
1. Setup Password
2. < RZCPG Lock
>
Save
x1
Back
2.
Include Controller
3. Update Controller
4. Create Areas
5. Set Associations
6. Security
Next Step
INSTALL CHECKLIST
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
x1
Cancel
CONTROLLER ASSOC
Dev: Room Controller
1. < Button 1
>
2. Area #1
3. Area ON/OFF
Save
screen will display with the selection box around 1. Button prompting you to select the button on your controller that you wish to associate an area to. Use side arrow buttons to toggle if applicable.
Scroll to 2. Area and choose an area you wish to associate to the button you've selected. This will allow the button on the chosen controller to control the desired area.
Selecting 3. Area ON/OFF allows you to set an
AREA ON/OFF
on your controller (for SCENE commands refer to
or SCENE command to that button
Advanced Settings). Once you are done press the right soft key
(Save) to complete. You will be prompted to continue setting associations or to proceed to the
NEXT STEP
STEP 6
by pressing the right soft key .
Security
NOTE: The INSTALL CHECKLIST screen will appear
with the selection box around
STEP 6 - Security when NEXT STEP is chosen from STEP 5.
Press the center button to bring up the SECURITY screen. Press the center button to select 1. Setup Password. Enter password using four of the eight buttons on the RZCPG
(1 ON, 1 OFF, 2 ON, 2 OFF etc.) NOTE: The password you
choose MUST be 4 characters long.
You will be prompted to, and must re-enter password.
Scroll to 2. and use the side arrow buttons to toggle between choices OPEN, RZCPG Lock and System Lock.
10
Page 13
Press right soft key (Save) to complete.
x1
INSTALL CHECKLIST
Installation Checklist complete. Press
button
to start using RZCPG.
x1
Stand By
-RZCPG-
Default Profile
1. Area #1
2. Area #2
3. Area #3
4. Area #4
Menu
x1
Back
3.
Update Controller
4. Create Areas
5. Set Associations
6. Security
7. Install Complete
Next Step
INSTALL CHECKLIST
NOTE: Selecting <RZCPG Lock> will lock the RZCPG. When you return to the HOME screen you will not have access to the MAIN MENU nor any screens until you press the right soft key and enter your password.
Selecting <System Lock> will only lock System Setup, preventing one from changing how the system is configured until the password is entered upon prompt.
STEP 7
Install Complete
NOTE: The INSTALL CHECKLIST screen will appear
with the selection box around STEP 7 - Install Complete when you save your security selection.
Press the center button to receive your confirmation that the INSTALL CHECKLIST is now complete. Press the center button again to start using the RZCPG.
The HOME screen of the RZCPG will be displayed.
11
Page 14
MAIN MENU SCREEN
x1
Ba ck
MAIN MENU
1. Device List
2. Who Is
3. Area
4. Profile
5. Settings
Home
x1
Ba ck
MAIN MENU
2. Who Is
3. Area
4. Profile
5. Settings
Home
6. System Setup
x1
Back
WHO IS...
Press button on unit
Acquiring node info
x1
Back
WHO IS...
This is node #7 Dimmer Scene Cap RT Slave Name: Hall dimmer
Press
x1
Ba ck (8
)
DEVICE LIST
Who Is
Bedroom Bathroom Hall
RZCPG
R
C
Room Controller
OFF
x1
Stand By
-RZCPG-
Default Profile
1. Area #1
2. Area #2
3. Area #3
4. Area #4
Menu
Pressing the right soft key while on the HOME screen will bring up the MAIN MENU screen where you can navigate through the various selections to edit or change settings.
DEVICE LIST
Selecting 1. Device List from the MENU screen will bring you to
the DEVICE LIST screen where a list devices included in the network will appear. From this list you can rename devices by pressing the center button to select a device and using TEXT EDITOR (pg.6), control ON/OFF and adjust intensity levels. NOTE: Pressing the 2 OFF button with the selection box around a dimming device will bring up the DEVICE CONTROL menu where you can use the and buttons to precisely raise or lower the level with slide control, which will be displayed at the bottom.
WHO IS
Selecting 2. Who Is from the MENU screen will bring you to
the WHO IS... screen where you can identify your devices. Simply press a button on a network included device to obtain the node information.
After the information is received by the RZCPG, it will display the device ID and the NAME assigned to the device you activated.
12
Page 15
AREA
1
ON
OFF
4
ON
OFF
x1
Back
PROFILE
<<
NEW
>>
Home
x1
Cancel
NEW PROFILE
Name: Profile #1
Save
Button: 1 Area: Area #1 Action: ON/OFF
x1
Back
PROFILE
<<
NEW
>>
Home
Profile #1 Profile #2 Profile #3
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Selecting 3. Area from the MENU screen will bring you to the AREA screen. You can create a new area, rename an existing area, modify devices in an area or delete an area (refer to Step 4 of
INSTALLATION CHECKLIST - Create Areas pg.9).
PROFILE
Selecting 4. Profile from the MENU screen will bring you to the PROFILE screen. Up to 16 profiles can be created to control different areas of your house with your RZCPG. Each device may be controlled by assigning an area to one of the four buttons on the RZCPG. NOTE: Default profile will control the first four areas created with ON/OFF control using the 1
ON , 1 OFF 4 OFF
buttons respectively.
With the selection box around
<<
>>
NEW
button . You can name your new profile by pressing the center button to select Name: (refer
to TEXT EDITOR pg. 6).
Once you name your new profile, press the center button to save and scroll to Button. Use side arrow buttons to toggle between button choices. The displayed button will be the button on your controller that your profile will react to.
Scroll to Area and use side arrow buttons to choose the area you wish to affect with this profile.
Scroll to Action and use side arrow buttons to choose an ON/OFF or SCENE (1-255) command. Scene commands will also give you a Fade option. Use side arrow buttons to toggle between fade choices DEFAULT,
IMMEDIATE, or 1 SECOND thru 127 MINUTES.
Press the right soft key (Save) to complete.
through 4 ON ,
press the center
13
Page 16
The HOME screen will display
x1
Stand By
-RZCPG-
Default Profile
1. Area #1
2. Area #2
3. Area #3
4. Area #4
Menu
x1
Stand By
-RZCPG-
Default Profile
1. Area #1
2. Area #2
3. Area #3
4. Area #4
Menu
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
x1
Ba ck
SETTINGS
1. Contrast
2. Buzzer
3. Security
4. Battery Level
Home
x1
Cancel
BUZZER
Save
Buzzer ON
x1
Cancel
CONTRAST
Save
050 %
x1
Stand By
-RZCPG-
Default Profile
1. Area #1
2. Area #2
3. Area #3
4. Area #4
Menu
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
with your newly created profile. Use the side arrow buttons
to toggle between profiles when on the HOME screen. Default Profile will display when none are selected. Use the button to deselect a profile.
SETTINGS
Selecting 5. Settings from the MAIN MENU screen will bring you to the SETTINGS screen.
CONTRAST
Sets the contrast for your RZCPG LCD screen as follows:
1. Select Contrast.
2. Use the and
buttons to adjust the percentage of contrast.
3. Press right soft key (Save) to complete.
BUZZER
Turns the buzzer on the RZCPG keypad ON or
. When the buzzer is ON, a beep will be heard
OFF
when pressing the keypad. When the buzzer is OFF, a click will be heard when pressing the keypad. The default setting is buzzer ON. Adjust the buzzer as follows:
1. Select Buzzer.
2. Use the side arrow
buttons to turn buzzer ON or OFF.
3. Press right soft key
14
(Save) to complete.
Page 17
SECURITY
x1
Back
BATTERY LEVEL
Home
- 2.88 +
x1
Back
SYSTEM SETUP
1. Install Checklist
2. Advanced
Home
x1
NO
ADVANCED
Advanced Settings?
YES
Sets the password and lock level for your RZCPG or System (refer to INSTALLATION CHECKLIST
- Security pg. 11).
BATTERY LEVEL
Displays the battery level for your RZCPG as follows:
1. Select Battery Level.
SYSTEM SETUP
Selecting 7. System Setup from the MAIN MENU screen will bring you to the SYSTEM SETUP screen.
Selecting 1. Install Checklist brings you to the Installation
Checklist (refer to pg. 5). NOTE: This feature is not
available on secondary remotes. Selecting 2. Advanced will
prompt you to continue with Advanced Settings. Pressing the right soft key (YES) will bring you to the ADVANCED screen.
NOTE: If you are unsure about any of the
following ADVANCED SETTINGS consult ViziaRF application guide or visit our website at www.ViziaRF.com.
15
Page 18
x1
Back
ADVANCED
1. Network
2. Association
3. HAI Setup
4. RTS Devices
5. Utilities
Home
x1
Back
NETWORK
1. Include Node
2. Exclude Node
3.
Ntwk Rediscovery
4. Update Devices
5. Remove Failed
Home
x1
Back
NETWORK
5. Remove Failed
6. Join Network
7. RZCPG Utils
8. Replace Node
9. Dev Properties
Home
NETWORK
x1
Back Home
NTWK REDISCOVERY
Powerlevel -6DB
To change powerlevel
press [4 OFF
]
Start? Press
x1
Cancel
FAILED NODE
Building Node List
Complete...65%
x1
Ba ck
REMOVE FAILED
Home
Bedroom Bathroom Hall Room Controller
Selecting 1. Network from the ADVANCED screen will bring you to the NETWORK screen.
1. Include Node
(refer to INSTALLATION CHECKLIST pg. 5)
2. Exclude Node
Use this option to remove a device from the network (refer to the individual device
instruction sheet for details).
3. Network Rediscovery
This feature is used for updating your network, specifically if nodes have moved or the network environment has changed. It will optimize the mesh network to ensure overall system routing integrity.
4. Update Controllers
(refer to INSTALLATION CHECKLIST - Update Controllers pg. 8).
5. Remove Failed
Use this option to detect devices that are non­operational and require removal from the network. Once the list is generated, you will press the center button
to select a device to remove. Press the right soft key (YES) to remove the device from the network.
6. Join as Secondary
This feature allows you to join this Leviton RZCPG
16
Page 19
as a secondary remote to
x1
NO YES
JOIN AS SECONDARY
WARNING!
This step will erase
all the data
Continue?
x1
NO
REMOVE FAILED
YES
Bedroom
Node 2
Remove?
x2
NO YES
JOIN AS SECONDARY
Would you like
to start building
node list?
x1
Back Home
RZCPG UTILS
1.
Get Data
2.
Send Data
3.
Update DB (Man)
4.
Update DB (Aut)
x1
Back Home
TX DATA
When prompted on receiving unit press one of the
group buttons
the network. Press the right soft key (YES) after the prompt to continue. NOTE:
This step will erase any existing data in the remote.
You will then be required to include this remote with your primary controller. Follow
the controller inclusion/ replication process of your primary controller (for RZCPG see pg. 7). This
secondary remote will prompt you to start building the node list. Press right soft key
(YES) to complete. A confirmation (version) screen will display the same Home ID as the primary, a new Node ID, a new serial number and an x2 designation at the top. NOTE: The secondary remote will be populated with only the device data of the primary remote (not Areas, Profiles). You can create new Areas and Profiles with your secondary remote. If you wish to duplicate the secondary RZCPG remote with the primary RZCPG remote's application information, use RZCPG Utilities.
7. RZCPG Utilities
This feature allows you to duplicate all necessary network data from a primary RZCPG remote into your secondary RZCPG remotes.
1. Get Data is selected from the receiving RZCPG remote to retrieve the selected data (Areas, Profiles,) from the sending RZCPG remote.
2. SEND data is selected from the primary RZCPG remote to transfer the
17
Page 20
data. Follow the prompts to
x1
Cancel
FAILED NODE
Building Node List
Complete...65%
x1
Ba ck
REPLACE NODE
Home
Bedroom Bathroom Hall Room Controller
x1
Ba ck
REPLACE NODE
Home
Prepare replacing
controller or press
button on slave when prompted
Start? Press
x1
Back Next Step
Node replaced! Node ID# 8: Garage
More? Press
REPLACE NODE
x1
Back Home
RX DATA
Setup Data Areas Profiles
Start? Press
Select receive items
complete this process.
NOTE: Update DB (no. 3
and 4) are only available on
secondary RZCPG remotes.
3. Update DB (Man) is used to manually perform a database update (devices in the network, their names and types) for a secondary remote that has joined the network. It will require you to press buttons on each individual device you wish to update in your secondary remote.
4. Update DB (Aut) is used to perform an automatic database update (devices in the network, their names and types) for a secondary remote that has joined the network.
8. Replace Node
Use this option to replace non-operational devices in the network. Once the list is generated, you will press the center button to select a device to replace. You will be prompted to prepare the controller to be replaced or to press a button on a slave device to be replaced when prompted. The button press will occur after you initiate the replacement process by pressing the center button on the RZCPG. After replacement you can name the replacing device
(refer to TEXT EDITOR pg. 6). Once your name is saved, you will receive
confirmation that the node has been replaced.
18
Page 21
x1
Back
ASSOCIATION
Room Controller Hall Controller Den Controller
Home
x1
Back(4
)
PROPERTIES
RZCPG
R
C
Bedroom Hall
Home
Room Controller
x1
Back
PROPERTY
Name: RZCPG NID: 001 Cntrl Room Portable Remote
Home
Mfg. by Leviton
9. Device Properties
x1
Back
RTS DEVICES
1. Set Routes
2. Set Hail
3. Update Routes
Home
x1
Back(3
)
HAI SETUP
Home
Bedroom Hall Room Controller
This feature will display information about a particular device (Name, Node ID and Description) when selected from the list.
Selecting 2. Association from the ADVANCED screen will bring you to the ASSOCIATION screen. NOTE: Consult ViziaRF
application guide for advanced ASSOCIATION options.
Selecting 3. HAI Setup from the ADVANCED screen will bring you to the HAI SETUP screen. This feature allows for the creation of subscriptions for devices when setting up a PC interface (refer to ViziaRF application guide).
Selecting 4. RTS Devices from the ADVANCED screen will bring you to the RTS DEVICES screen. This is a network optimization feature which can enhance performance and communication ability (refer to
ViziaRF application guide).
ASSOCIATION
HAI SETUP
RTS DEVICES
19
Page 22
UTILITIES
x1
Back Home
UTILITIES
1. Who Is
2. Version
3. Rediscovery
4. Dev Properties
5. Reset
x1
Back Home
UTILITIES
3. Rediscovery
4. Device Property
5. Reset
6. Test ZW
7. Test CR
x1
Back
VIZIA RF V1.09
Z-Wave 2.06
Dec 7 2006
HID: 00989680 NID: 1 S/N: 007358DH
Menu
x1
Cancel
Save
REDISCOVERY PL
-3 DB
+/– to adjust
x1
RESET
ALL DATA
WILL BE
LOST
PROCEED?
NO YES
Selecting 5. Utilities from the ADVANCED screen will bring you to the UTILITIES screen.
1. Who Is...
(refer to WHO Is... pg.13).
2. Version
This feature displays the
ViziaTMRF and Z-WaveTM versions, the Home ID, Node ID and Serial No. of your RZCPG. You can also access this screen by pressing the up arrow button while on the HOME screen.
3. Rediscovery PL
This feature allows you to change the power level used for network rediscovery (refer to
Network Rediscovery pg. 19).
4. Device Properties
(refer to Device Properties pg. 22).
5. Reset
Resets your RZCPG back to factory default and erases any programmed information from the remote. NOTE: Resetting the RZCPG to factory default does not reset your devices. If you want to factory reset your devices refer to the individual device instruction sheet for that device.
6. Test ZW
WARNING: For factory use only! DO NOT USE.
7. Test CR
WARNING: For factory use only! DO NOT USE.
20
Page 23
NOTES
Page 24
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing
Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591.
This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied
warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied
warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental,
indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies
provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
For additional information, contact Leviton’s Techline
at 1-800-824-3005 or visit Leviton’s website at
www.Leviton.com (www.ViziaRF.com)
DI-104-RZCPG-20A-X1
Page 25
This page is NOT to be printed in the booklet
DOCUMENTATIONDOCUMENTATION
LEVITON INSTRUCTION SHEET/MANUALLEVITON INSTRUCTION SHEET/MANUAL
SPECIFICATIONSSPECIFICATIONS
LG 12/19/06
Helvetica
DI-104-RZCPG-20A-X1
Black
N/A
Final fold size:Final fold size:
40 lb. offset
Overall size:Overall size:
5.75" x 6" (Printer Spread)
5.75" x 3" (booklet - saddle stitch)
Paper size:Paper size:
Saddle Stitch
OVERALL SIZE
6"
2 3
5.75"
3"
Booklet
5.75"
FINAL SIZE
Cat. No.