Leviton N600P-D20 User's Guide

Page 1
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that
WEB VERSION
LIMITED 2 YEAR WARRANTY AND EXCLUSIONS
this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for two years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such two year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton
Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability for labor for
removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions.
There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the
duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to two years. Leviton is not liable for incidental, indirect, special, or consequential
damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided
herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
For Technical Assistance Call:
1-800-824-3005
www.leviton.com
DDS 6000 / 6000+
PK-93381-10-00-0B
SATELLITE DIMMER PACKS
USER GUIDE
Software Revision 1.0 and above
Document Revised: 8-30-02
Copyright 2002
Page 1
PK-93381-10-00-0B
Page 2
Table of Contents
WEB VERSION
INTRODUCTION ................................................................................................................................................... 3
SPECIFICATIONS ................................................................................................................................................. 3
MOUNTING ........................................................................................................................................................... 3
AC POWER CABLE .............................................................................................................................................. 3
AC OUTPUT RECEPTACLES .............................................................................................................................. 3
PERMANENT CONNECTION ............................................................................................................................... 4
AC Input ...................................................................................................................................................... 4
AC Output ................................................................................................................................................... 4
LED INDICATORS ................................................................................................................................................. 4
CHANNEL FUSES ................................................................................................................................................ 4
MICROPLEX MULTIPLEX CONTROL WIRING ................................................................................................... 5
ANALOG 0-10 VDC CONTROL WIRING ............................................................................................................. 5
DMX512 MULTIPLEX CONTROL WIRING ........................................................................................................... 5
AUTO LAMP TEST ............................................................................................................................................... 5
INTERNAL CONFIGURATION DIP SWITCH SELECTION .................................................................................. 6
Softstart ...................................................................................................................................................... 6
NON DIM Channels (Relay Mode) ............................................................................................................. 6
AUTO SEQUENCING MODE ................................................................................................................................ 6
INSTALLATION AND OPERATION TIPS ............................................................................................................. 6
ADDRESSING ....................................................................................................................................................... 7
ADDRESSING
When using any of the multiplex control systems, the DIP switches on the front panel of the DDS 6000 must be set to assign the desired dimmer channels. The switches control the dimmer channels in groups of four. See the following chart for settings.
DIP SWITCH CHANNEL ASSIGNMENTS (1=up, 0=down)
CONTROL
1-4
13-16
25-28
37-40
49-52
61-64
73-76
85-88
97-100
109-112
121-124
133-136
145-148
157-160
169-172
181-184
193-196
205-208
217-220
229-232
241-244
253-256
265-268
277-280
289-292
301-304
313-316
325-328
337-340
349-352
361-364
373-376
385-388
397-400
409-412
421-424
433-436
445-448
457-460
469-472
481-484
493-496
505-508
1234567
0000000
1100000
0110000
1001000
0011000
1111000
0100100
1010100
0001100
1101100
0111100
1000010
0010010
1
110010
0101010
1011010
0000110
1100110
0110110
1001110
0011110
1111110
0100001
1010001
0001001
1101001
0111001
1000101
0010101
1110101
0101101
1011101
0000011
1100011
0110011
1001011
0011011
11110 11
0100111
1010111
0001111
110 1111
0111111
CONTROL
5-8
17-20
29-32
41-44
53-56
65-68
77-80
89-92
101-104
113-116
125-128
137-140
149-152
161-164
173-176
185-188
197-200
209-212
221-224
233-236
245-248
257-260
269-272
281-284
293-296
305-308
317-320
329-332
341-344
353-356
365-368
377-380
389-392
401-404
413-416
425-428
437-440
449-452
461-464
473-476
485-488
497-500
509-512
1234567
1000000
0010000
1110000
0101000
1011000
0000100
1100100
0110100
1001100
0011100
111110 0
0100010
1010010
0001010
1101010
0111010
1000110
0010110
1110110
0101110
1011110
0000001
1100001
0110001
1001001
0011001
1111001
0100101
1010101
0001101
1101101
01
11101
1000011
0010011
1110011
0101011
1011011
0000111
1100111
0110111
1001111
00 11111
1111111
CONTROL
9-12
21-24
33-36
45-48
57-60
69-72
81-84
93-96
105-108
117-120
129-132
141-144
153-156
165-168
177-180
189-192
201-204
213-216
225-228
237-240
249-252
261-264
273-276
285-288
297-300
309-312
321-324
333-336
345-348
357-360
369-372
381-384
393-396
405-408
417-420
429-432
441-444
453-456
465-468
477-480
489-492
501-504
1234567
0100000
1010000
0001000
1101000
0111000
1000100
0010100
1110100
0101100
1011100
0000010
1100010
0110010
1001010
0011010
1111010
0100110
1010110
0001110
1101110
011111 0
1000001
0010001
1110001
0101001
1011001
0000101
1100101
0110101
1001101
0011101
111110 1
0100011
1010011
0001011
1101011
0111011
1000111
0010111
1110 111
0101111
10 11111
Page 2
When the automatic sequencing feature is operating, the DIP switch selects the operating sequence pattern and speed. See the section on INTERNAL CONFIGURATION DIP SWITCH SELECTION for details.
Page 7
Page 3
INTERNAL CONFIGURATION DIP SWITCH SELECTION
WEB VERSION
Caution: The following procedures should be performed by qualified personnel only.
Remove all power and remove the cover of the dimmer pack. Locate and change configuration DIP switch settings on the firing card as indicated in the following section.
Softstart
The Softstart mode of operation forces at least a 1/10th second delay between the output being full OFF to the output being full ON to allow a more gradual warming of the lamp filaments. Thermal shock and inrush currents are reduced thereby increasing lamp life. Softstart should not be used when quick dimmer response is desired, such as chasing.
To activate Softstart, turn OFF switch number one (1) on the configuration DIP switch on the firing card. Moving this switch to ON will deactivate Softstart.
NOTE: The channels of the DDS 6000 configured for NON DIM operation will not be affected by softstart.
NON DIM Channels (Relay Mode)
Any of the channels of the DDS 6000 may be configured as NON DIM channels. This will cause the output of the channel to go to full ON whenever the input signal is over 15%. When the input signal drops to less than 10%, the channel output goes to full OFF. This is the equivalent of a zero-crossing solid state relay.
To configure a channel for NON DIM operation, simply move the respective switches on the configuration DIP switch to the OFF position on the firing cards as indicated below. Moving the switch to ON will restore dimming operation.
CHANNEL DIP SWITCH CHANNEL DIP SWITCH
1 3 OFF 2 4 OFF
3 5 OFF 4 6 OFF
AUTO SEQUENCING MODE
The DDS 6000 dimmers can be configured to perform stand alone Automatic Sequencing in place of Auto Lamp Test. This is useful for lighting displays and show windows. The four channels will automatically fade from one to another in a preprogrammed pattern and time selected by the front panel DIP switch whenever DIP switch #8 is up and no multiplex signal is detected. The analog control input will continue to operate while the dimmer is sequencing.
To enable Automatic Sequencing Mode move the switch on the internal configuration DIP switch #2 to OFF.
Front Panel DIP switch sequence settings (not internal DIP switch):
STEP TIME SWITCH 1, 2, 3 PATTERN SWITCH 4, 5, 6
1 SECOND OFF, OFF, OFF 2 CHAN BUILD OFF, OFF, OFF
3 SECOND ON, OFF, OFF 3 CHAN SEQUENCE ON, OFF, OFF
5 SECOND OFF, ON, OFF 3 CHAN BUILD OFF, ON, OFF
10 SECOND ON, ON, OFF 2 & 4 CHAN ALT ON, ON, OFF
15 SECOND OFF, OFF, ON 4 CHAN SEQUENCE OFF, OFF, ON
30 SECOND ON, OFF, ON 4 CHAN BUILD ON, OFF, ON
45 SECOND OFF, ON, ON 4 CHAN BUILD + OFF, ON, ON
60 SECOND ON, ON, ON 4 CHAN RANDOM ON, ON, ON
DIP switch #7 ON causes all above sequences to ping-pong.
INSTALLATION AND OPERATION TIPS
Care should always be taken to:
1) Keep all AC wiring away from control wiring.
2) We also recommend power up and performance checks be done one unit at a time. This can be a real
time saver should problems arise thus eliminating unnecessary isolation techniques to resolve problems.
Page 6
INTRODUCTION
Thank you for your decision to purchase a Leviton-NSI product.
The Leviton-NSI DDS 6000 represents a key part of a state of the art, integrated lighting control system. These dimmers may operate in a “stand alone” mode for automated lighting of displays or may be combined with a Leviton-NSI memory lighting console for total lighting control.
The DDS 6000 provides four channels of 1200 watts each. This dimmer is designed for portable or permanent use for entertainment or display lighting. Several DDS dimmer packs may be combined for more channels of lighting.
SPECIFICATIONS
Number of Channels: Four.
Output Capacity: 1200 Watts per channel.
Input Power: DDS 6000-15: 120 VAC, 1800 Watts Max. (One power source)
Dimmer Control System: Microprocessor digital phase control dimming or zero-crossing relay mode.
Load Filtering: 400 Micro-Second Rise Time.
Control Input Types: 0-10 VDC each channel on a 5-pin DIN connector.
Control Wiring: Class 2 low voltage.
Output Connections: 2 NEMA 5-15 outlet per channel.
Cooling System: Passive internal aluminum heatsinks.
Load Type: AC lighting (tungsten) loads only.
Enclosure Type: For indoor use only (Utilizer Dans Un Endroit A L'Abri).
Ambient Temperature: 100 degrees maximum.
DDS 6000-15: 240 VAC, 2400 Watts Max. (One power source) DDS 6000-20: 120 VAC, 2400 Watts Max. (One power source) DDS 6000 Plus -15: 120 VAC, 3600 Watts Max. (Two power sources) DDS 6000 Plus -15: 240 VAC, 4800 Watts Max. (Two power sources) DDS 6000 Plus -20: 120 VAC, 4800 Watts Max. (Two power sources)
Microplex multiplex signal (128 channel) on a 3-pin XLR type connector. DMX512 digital signal (512 channel) on a 5-pin XLR optional.
Screw terminals optional.
MOUNTING
The Leviton-NSI DDS 6000 dimmer pack is designed to be mounted vertically. Each dimmer pack is provided with two mounting flanges or ears designed for securing to the center of truss or attaching to other vertical surfaces.
Since the DDS 6000 depends upon convection cooling, room air flow must be insured. Keep the air vents located on front and each side of the dimmer pack clear of dust or any obstructions. In order for unit to cool properly the control receptacles must be oriented towards the floor.
If several units are to be operated in a small enclosed room, adequate ventilation must be provided to prevent the room temperature from exceeding 100 degrees Fahrenheit.
AC POWER CABLE
This is the main power cord(s) for your dimmer pack which ultimately carries all of the AC power consumed by lights connected to the dimmer pack. The DDS 6000 with the NEMA 5-15 plug is limited to 1800 Watts max., while the unit with the NEMA 5-20 plug will support 2400 Watts. The DDS 6000 Plus includes two cords, one per each two channels, which doubles the maximum capacity. The power cord(s) must be connected to a power source capable of supplying the total power drawn by the lights. (See SPECIFICATIONS for details on maximum power capability).
AC OUTPUT RECEPTACLES
The DDS 6000 has two AC receptacles for each channel. These receptacles provide power to the lamps in your lighting system. The amount of power supplied to these outlets controls the intensity of the lamps connected. Most 120VAC lamps and fixtures, and some transformer type low-voltage fixtures may be connected to these outlets.
Page 3
Page 4
C
HANNEL
O
C
C
C
O
6000
M
Y
Y
CO
2
D
J80
U
C
US
R
G
W
W
,
800
,
00W
OUTPU
G
L
800
L
L
L
L
800
L
L
L
LDDS 6000
5
0
6000
5DDS 6000
0
U
.
SS
8FUSES
3
S
USE ONLY
V
Y
S
USE ONLY
V
S
0-10VDC
UT
1
234
WEB VERSION
HANNEL
NE
TW
DDS
DIGITAL DIMMING SYSTE
1200 WATTS PER CHANNEL
INDOOR USE ONL
LISTE
2
MODE
- 1
DDS 6000 - 2
DDS PLUS - 1
PLUS - 2
LEVITON MFG. CO., INC. TUALATIN, O
AC LIGHTING ONL
NTROL WIRING CLASS
INPUT RATIN
120V, 60HZ, 1800
120V, 60HZ, 2400
2 @ 120V, 60HZ
1
W
2 @ 120V, 60HZ
24
NOT TO EXCEED 1
NOT TO EXCEED 2400W PER INPUT TOTA
IND. CONT. EQ.
The total lamp wattage connected to each channel must not exceed the rating of each channel (see SPECIFICATIONS). For inductive loads, the total lamp volt-amperes plus the volt-amperes of any ballast or transformer must not exceed the rating of each channel.
NOTE: Some inductive type loads, such as transformers, ballasts, and motors with poor factor power may cause the dimmer to output DC type current. This may cause the load to draw excessive current and overheat, causing damage to the transformer, ballast or motor. For this reason, it is necessary to insure any inductive loads are fused individually for their respective normal operating current.
HANNEL
HANNEL
T RATIN
120V, 60HZ, 1200W PER CHANNE
NOT TO EXCEED 1
W TOTA
120V, 60HZ, 1200W PER CHANNE
NOT TO EXCEED 2400W TOTA
120V, 60HZ, 1200W PER CHANNE
W PER INPUT TOTA
120V, 60HZ, 1200W PER CHANNE
FOUR
MICROPLEX MULTIPLEX CONTROL WIRING
Microplex is the control protocol used on most Leviton-NSI lighting consoles. This system uses a single three conductor cable to transmit up to 128 channels of dimmer control. For short distances (50 feet or less) a standard microphone cable may be used to carry both the control signal and the DC power source for Leviton­NSI control consoles. Longer distances may be accommodated with 18 gauge or better cable to reduce voltage losses of the power supply.
Connect the Microplex control cable to either of the three pin XLR jacks. Since both jacks are wired in parallel, another control cable may be connected between the remaining jack and another dimmer pack. Many dimmer packs may be “daisy chained” together in this manner.
Be sure to set the Channel Address DIP switch as required (see ADDRESSING).
Female Microplex
XRL Pin Configuration
2
3
1
MPX Data
+15 VDC
Common
ANALOG 0-10 VDC CONTROL WIRING
Each of the four channels of the DDS 6000 may be operated by an analog 0-10 VDC control voltage. This type of control will provide 0% intensity at 0 volts and 100% intensity at 10 volts. Any or all of the DDS 6000 dimmer channels may be operated in this manner simultaneously with any multiplex control input. Each dimmer will respond to the greater of any control inputs.
The analog control input uses a standard 5 pin DIN plug which is available from most electronics supply houses. Connect each if the positive channel control wires to the desired dimmer channel input pins of the plug. Connect the common (ground) control wire to the pin indicated on the diagram. Consult the documentation of the analog control console or device you are using for the proper connections. The control input impedance is 4.7K ohms.
Channel 4 Channel 1
Common
0-10V Input
2
3
45Channel 3 Channel 2
1
PERMANENT CONNECTION
The DDS 6000 is available as an optional DDS 6000 Plus - 20 terminal version. This version must be installed by qualified personnel.
AC Input
Conduit containing line conductors enters pack through one of the knockouts in the top end. The two 20A, 120V, 60Hz, 2 wire line circuits, A and B, are terminated to their respective terminals labeled Line and Line N. The terminals accept wire sizes 22-8 AWG CU and have a torque rating of 8 in-lbs. Line equipment grounding conductor, if a wire, terminates to the lug labeled GND. The ground lug accepts wire size 14-6 AWG CU and has a torque rating of 35 in-lbs. (14-10 AWG), 40 in-lbs. (8 AWG), and 45 in-lbs. (6 AWG).
AC Output
Conduit containing load conductors enters pack through one of the knockouts in the top end. The four 1200 W max., 120V, wire load circuits, 1 through 4, are terminated to their respective terminals labeled Load and Load N. Circuits 1 and 2 are supplied from input A, and circuits 3 and 4 from input B. The control power supply is also supplied by input A. Terminal rating are the same as indicated above for line terminals.
LED INDICATORS
The front panel indicator LEDs indicate the status of the relay.
RED — Indicates the firing card is receiving DC power.
GREEN — Steady indicates a multiplex control signal is being received.
YELLOW — Indicates a respective dimmer channel is active and the LED indicates relative intensity.
CHANNEL FUSES
Each channel is protected by a fuse to help prevent overload and damage to the power control devices used in the dimmer. Be sure to replace the fuse with the same type of rating. Replacement with the wrong fuse is dangerous and will void your warranty.
NOTE: Lamps may sometimes cause a temporary “short-circuit” when the filament burns out and cause the fuse to blow. This is normal and protects the internal dimmer circuitry from damage.
MULTIPLEX LOOP THR
FUSE
LEVITON MFG. CO., INC
12A, 250
NON-TIME-DELA
FUSE
TUALATIN, OREGON
PWRMPX
MPX ADDRE
INP
1234567
12A, 250
NON-TIME-DELAY
FUSE
DMX512 MULTIPLEX CONTROL WIRING
DMX512 is the United States Institute of Theater Technology (USITT) standard for the digital control of dimmers. Leviton­NSI DDS dimmer products can be converted from Microplex to DMX512 digital multiplex with a simple kit available from your dealer.
DMX512 is the preferred type of control wiring when many dimmer channels are used, because of the high update rate and the resistance to interference. It is recommended in locations subject to electrical noise. DMX512 only requires 3 wires to transmit lighting levels for as many as 512 relay or dimmer channels. Most of the Leviton-NSI lighting control consoles can optionally use this interface.
Connect the DMX512 cable from the control console to the male input connector. Another cable may be connected from the female connector to the male connector of another pack. Many dimmer packs may be “daisy chained” or connected together in this manner.
N / C
Be sure to set the Channel Address DIP switch as required (see ADDRESSING).
Female DMX512
XLR Pin Configuration
5N / C
4
3
DMX Data +
1
2
Common
DMX Data -
AUTO LAMP TEST
Whenever DIP switch #8 is in the OFF (down) position and there is no multiplex signal detected, all channel outputs will come to full intensity. The automatic sequencing feature must be disabled for this Auto Lamp test to operate.
Page 4
Page 5
Loading...