Single Pole Wide View Motion Activated Light Control
Ratings: 120VAC, 60Hz 300W 2.5A Resistive, 150W LED and CFL, 1/6HP
Cat. Nos. IPSN2, IPVN2 - INDOOR USE ONLY
WARNINGS
• TO AVOID FIRE, SHOCK OR DEATH: TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING!
• TO AVOID PERSONAL INJURY OR PROPERTY DAMAGE, DO NOT install to
control a receptacle, or a load in excess of the specified rating.
• To be installed and/or used in accordance with electrical codes and regulations.
• If you are not sure about any part of these instructions, consult an electrician.
INSTALLATION
Mounting LocationFeatures
• Cat. Nos. IPSN2 and IPVN2 have a sensing area of coverage of 30 ft x 30 ft
and a sensing angle of 180°. See coverage diagram for details.
• Adjustable ambient light (IPSN2 only) and time delay controls are located on the front of the device. See adjustment setting section for details.
• Indicator light alerts the user of device status.
• Adjustable time delay setting for 30 seconds, 5 minutes, 15 minutes and 30 minutes.
• The device responds to temperature changes and care should be taken when mounting the device.
• DO NOT mount directly above a heat source, in a location where hot or cold drafts will blow directly on the sensor, or where unintended motion (e.g., hallway traffic) will be within sensor's field-of-view.
Installation
WARNING: TO AVOID FIRE, SHOCK OR DEATH, turn off power at circuit breaker or
fuse and test that the power is off before wiring.
1. Identify your wires (most common):
NOTE: Neutral wire is required for operation. If the wiring in the wall box does not
resemble this configuration, consult an electrician.
LINE
GROUND
GROUND
LOAD
NEUTRAL
CAUTIONS
• Clean outer surface gently with damp cloth only. DO NOT use soaps or cleaning liquids.
• No user serviceable components. DO NOT attempt to service or repair.
• Use this device WITH COPPER CLAD WIRE ONLY.
PK-A3325-10-00-2A
You Will Need:
• Slotted/Phillips screwdriver
• Pencil
• Electrical tape
• Cutters
• Pliers
• Ruler
2. Wire.
Working on one connection at a time, connect wires as shown.
NOTE: Make sure the line and load are properly oriented or the device will not work.
NOTE: Neutral connection is required.
LINE
GROUND
LOAD
NEUTRAL
ENGLISH
3. Test.
• Restore power.
• Wait 5 seconds for sensor to power up.
• IPSN2: lights will automatically turn ON after power is applied.
• IPVN2: press push pad. Lights should turn ON.
NOTE: If lights do not turn ON, refer to the "What to do if..." section.
5. To adjust settings
• Remove wallplate and sensor face (see section "Changing Your Device Cover".)
• Adjust dials with small screwdriver.
4. Default Dial Settings
Time Ambient
(5 min.) (15 min.)
1 2
0 3
(30 sec.) (30 min.)
NOTE: For IPVN2 California Title 24 applications, set the Time setting to 0, 1 or 2.
6. Dial Descriptions Automatic ON Mode (default setting):
Time Dial
Setting
0 30 seconds after no movement is detected
1 5 minutes after no movement is detected
2 15 minutes after no movement is detected
3 30 minutes after no movement is detected
(IPSN2 only)
Light Level
Low
1 2
0 3
Lights will remain on for . . .
Some light
Most lightManual ON
NOTE: For representation purposes, IPSN2 shown.
7a. Mode Description - IPVN2
Modes When to use this setting Time
Vacancy When Manual On, Automatic
Off lighting control is desired.
(manual ON mode)
Turns light
on when...
Any Push the pad.
OR
Move around within 30 seconds of the light turning off.
Ambient
Light Level
Lights will turn on . . .
(IPSN2 Only)
0
Auto ON is disabled.
1 when there is very little ambient light
2 when there is some ambient light
3 when there is a lot of ambient light
Light turns off when...
If no motion is detected for the duration of the programmed time period. OR Push the pad.
30ft
9.1m
1.4m
2.1m
7b. Mode Descriptions - IPSN2
Modes
Occupancy When automatic On/
Manual Mode
When to use this
setting
Off lighting control is desired.
To bypass Auto On function temporarily
Anytime Any 0-Off Push the pad.
Time
Amount of Ambient Light
Present
Any 1 – light will turn on
automatically if room is darkest 2 – light will turn on automatically
if room has more light 3 – light will turn on automatically
if room has the most light
Turns light
on when...
Walk into the view of the sensor when the light is off and it is darker
than the ambient light level set. OR Push the pad.
Light turns off when...
If no motion is detected for the duration of the programmed time period.
Push the pad to turn off the light. NOTE: any motion detected will be ignored until no motion has been detected for the programmed time period.
If no motion is detected for the duration set in the programmed time period. OR Push the pad.
8. Mount.
Turn off power at circuit breaker before completing the installation.
• Gently push wires into wall box. Screw light control to box.
• Install wallplate base and snap on Decora® wallplate.
• Restore power.
Sensing Area Coverage
1. Horizontal field of view:
6ft
1.8m
6ft
1.7m
9.1m
9. Manual Operation
• Press push pad to manually turn on the load. Internal time will activate and turn off load when set time out expires.
• Press and release push pad to manually turn off load.
NOTE: For IPSN2 ,using the push pad to turn off the load will temporarily bypass Auto On.
2. Vertical field of view:
27ft
8ft
2.6m
6ft
1.7m
4ft
1.2m
8.4m
30ft
9.1m
lens
locator light (will flash any time motion is detected)
push
pad
7ft
4ft
30ft
Changing your device color
Remove Replace
What to do if...
Issue
Lights do not operate with push pad and LED indicator does not blink when motion is present
Lights do not switch ON when motion is detected - IPSN2
Lights always stay ON
Lights do not turn ON - IPVN2
FCC STATEMENT: This device complies with Part 15 of the FCC Rules. Operation is subject to following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation of the device. This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving Antenna. • Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/tv technician for help.
FCC CAUTION: Any changes or modifications not expressly approved by Leviton Manufacturing Co., Inc., could void the user's authority to operate the equipment.
FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada should contact Leviton in writing at Leviton Manufacturing of Canada Ltd to the attention of the Quality Assurance Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 or by telephone at 1-800-405-5320.
LIMITED 5 YEAR WARRANTY For Leviton’s limited product warranty, go to www.leviton.com. For a printed copy of the warranty,call 1-800-824-3005.
Patents covering this product, if any, can be found on www.leviton.com/patents.
© 2020 Leviton Mfg. Co., Inc.
Make this adjustment
• verify wiring connections to sensor
• motion is beyond sensing range - move closer to switch
• adjust the light level adjustment clockwise. If the light was manually turned off, ensure the sensor does not see any activity (motion) for the duration programmed in the time setting.
• check time delay settings and compare to how long the lights stay ON
• make sure no motion occurs in coverage area for time selected by covering the lens
• check that switch is not installed near a heat source (like stove, lights, heat vents) or detecting motion from an adjacent area (like hallway traffic) and if it is, relocate it
• make sure that control is installed correctly
• make sure the power is ON
• check to make sure the light bulb is functional
For Technical Assistance Call: 1-800-824-3005 (USA Only)
or 1-800-405-5320 (Canada Only) www.leviton.com
PK-A3325-10-00-2A