2.10 Positioning the Cable Clamp .......................................................................................16
3 Standard Statements and Warranty ...........................................................................................17
Page 4
WEB VERSION
1 WARNINGS
Safety Instructions
WARNING: TO AVOID INJURY, DEATH OR PROPERTY DAMAGE, follow these safety instructions.
Electrical hazard!
• The installation, commissioning and maintenance of the charging station must only be performed by
correctly trained, qualified and authorized personnel who are knowledgeable of and responsible for the
compliance with existing standards and installation regulations.
• If the specifications for the location are not followed, this can result in death, injury or equipment damage!
• The pedestal must always be fitted with two charging stations!
Use of this manual
This installation manual is intended for qualified personnel only.The information and instructions in the
manual about selecting the location, installation and connection of the charging station must be adhered to.
EPCM1-OF3:Quantity
Pedestal Body
M8 100mm Expansion Screw
M6 20mm Screw
M6 Spring Washer
M6 Flat Washer
M8 16mm Screw
M8 Flat Washer
M40 Cable Gland
M8 Spring Washer
M5 22mm Screw
Junction of Pedestal
Connector Base
Screwdriver
Installation Manual
1
4
14
14
14
16
6
2
6
10
1
2
1
1
EPCM2-OF3:Quantity
Mounting Template
1
EPCM3-OF3:Quantity
Cord Management
System
1
4
Page 5
2 INSTALLATION
WEB VERSION
2.1 Making Drill Holes
1. Mark the 4 holes on the concrete foundation using the base-plate of the pedestal. Make sure that
the connection cable is located precisely underneath the opening in the base-plate.
2. Drill the 4 mounting holes:
Diameter: 10 mm.
Drill-hole minimum depth: 84 mm.
3. Hammer the anchors (not included) so that they are flush with the floor.
4. Thread the connection cables from the bottom through the pedestal upwards through
the cable opening.
11.0 in. (280.0mm)
4-Ø0.39 in. (Ø10.0 mm.)
6.1 in. (155.0 mm.)
5
Page 6
2 INSTALLATION
WEB VERSION
2.2 Anchoring
1. Position the pedestal (lower part) directly over the cable outlet.
2. Anchor the pedestal (lower part) to the foundation using 4 sets of M8 100 mm. expansion screws
(flat washer, spring washer and bolt were included).
3. Remove the 4 M6 20 mm. screws of wiring window on pedestal.
6
Page 7
2 INSTALLATION
WEB VERSION
2.3 Upper Part Installation
1. Connect the junction by 6 sets of M6x20 mm. screws with spring washer and flat washer.
2. Cap the upper part of pedestal with cable management structure.
7
Page 8
2 INSTALLATION
WEB VERSION
2.3 Upper Part Installation (Continued)
3. Fix the upper part with 6 sets of M6 20mm screws with spring washer and flat washer.
8
Page 9
2 INSTALLATION
WEB VERSION
2.4 Cable Gland Installation
1. Insert the 2 cable glands to the pedestal properly.
2. Fix 2 M8x16mm screws with 5 mm. thread length reserved for charger holder plate.
9
Page 10
2 INSTALLATION
WEB VERSION
2.5 Bracket Installation
1. Take off the wall-mounted bracket of 2 chargers, and fix it in the corresponding position on the
charger holder plate with 8 of M8x16 mm. screws.
10
Page 11
2 INSTALLATION
WEB VERSION
2.6 Connector Base Installation
1. Use 8 of M5x22 mm. screws to fix the 2 connector bases in the corresponding
position of charger holder plate.
11
Page 12
2 INSTALLATION
WEB VERSION
2.7 Mounting the Charging Station
1. Mount two (2) charging stations on the charger holder plate using four (4) of M5x12 mm. screws
on two sides of the charger (screws from chargers).
12
Page 13
2 INSTALLATION
WEB VERSION
2.8 Charger Holder Plate Installation
1. Hook the charger holder plate on the screws, and fix with 4 M8x16 mm. screws with spring
washer and flat washer.
13
Page 14
2 INSTALLATION
WEB VERSION
2.9 Connecting
1. Thread the connection cables from the side to cable gland.
14
Page 15
2 INSTALLATION
WEB VERSION
2.9 Connecting (Continued)
1. Perform the electrical connection and commissioning in accordance with the instructions
2. Fix the 4 M6x20 mm. screws of wiring window.
15
Page 16
2 INSTALLATION
WEB VERSION
2.10 Positioning the Cable Clamp
1. Pull on the cable of the cable management system to hold the cable clamp in your hand.
2. Remove the two screws as shown below.
3. Determine where to position the charging station cable clamp.
Recommendation: The cable portion between the clamp and the charging connector must
not touch the ground when the cable management system is completely retracted. The cable
should hang about 5 cm. (2 in.) above the ground.
4. Set the clamp over the band and reinsert the bolt and washer (M5 28mm) in it by adjusting the
torque of your tool to 13.3 in-lbs.
5. Let the cable retract itself. Verify the clearing between the charging station cable and the ground.
6. Return the plug to the connector base.
16
Page 17
3 STANDARD STATEMENTS AND WARRANTY
WEB VERSION
FCC STATEMENT:
This device complies with Part 15 of the FCC Rules and ISED License-exempt RSS standard(s). Operation is subject
to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept
any interference received, including interference that may cause undesired operation. Changes or modifications not
expressly approved by Leviton could void the user’s authority to operate the equipment.
These limits are designed to provide reasonable protection against harmful interference in a commercial installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This Class A digital apparatus complies with Canadian CAN ICES-3(A)/NMB-3(A)
FCC SUPPLIER’S DECLARATION OF CONFORMITY:
This device manufactured by Leviton Manufacturing Co., Inc. 201 North Service Road, Melville, NY 11747.
www.leviton.com. This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
TRADEMARK DISCLAIMER:
Leviton and the Leviton logo are trademarks of Leviton Manufacturing Co., Inc. Use herein of third party trademarks,
service marks, trade names, brand names and/or product names are for informational purposes only, are/may be the
trademarks of their respective owners; such use is not meant to imply affiliation, sponsorship, or endorsement.
Specifications and price subject to change at any time without notice.
FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada should contact Leviton in writing at Leviton Manufacturing of
Canada ULC to the attention of the Quality Assurance Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9
or by telephone at 1 800 405-5320.
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale
by Leviton is free of defects in materials and workmanship under normal and proper use for 2 years from the purchase date.
Leviton’s only obligation is to correct such defects by repair or replacement, at its option. For details visit www.leviton.com or call 1-800-824-3005. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This
warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered
in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is
required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular
purpose, is limited to 5 years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without
limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty
obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
For Technical Assistance Call: 1-800-824-3005 (USA Only) or 1-800-405-5320 (Canada Only) www.leviton.com
LIMITED 2 YEAR WARRANTY AND EXCLUSIONS
17
Page 18
WEB VERSION
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.