Leviton 6615-P Installation Instructions Manual

Page 1
• Disconnect wires from screw terminals or Quickwire™ slots (shown).
• Pull off pre-cut insulation from Dimmer leads.
• Make sure that the ends of the wires from the wall box are straight (cut if necessary).
• Remove 5/8" (1.6 cm) of insulation from each wire in the wall box (shown).
For Single-Pole Application, go to Step
5A.
For 3-Way Application, go to Step 5B.
Single Pole (One location) or 3-Way (Multi-location)
Electronic Low-Voltage Slide Dimmer
Cat. No. 6615-P
300W–120VAC, 60Hz
INSTALLATION INSTRUCTIONS
DI-00X-06615-02B
Tools needed to install your Dimmer:
Slotted/Philips Screwdriver Electrical Tape Pliers Pencil Cutters Ruler
Installing Dimmer by itself or with other devices:
If installing Dimmer in a single device application, proceed with the INSTALLING YOUR DIMMER section. If installing Dimmer in a multi­device application, proceed as follows:
MULTI-DEVICE APPLICATION
In multi-dimmer installations, the reduction of the dimmerʼs capacity is required. Refer to the chart for maximum load per dimmer.
MAXIMUM BULB WATTAGE
The maximum bulb wattage is determined by the efciency of the transformer in the low-voltage lighting system. Transformer efciencies will vary from different manufacturers; consider 80% efcient as average. Use the chart to determine maximum bulb wattage for typical transformer efciency ratings.
INSTALLING YOUR DIMMER
NOTE: Use check boxes when Steps are completed.
WARNING: To avoid re, shock, or death; TURN OFF
POWER at circuit breaker or fuse and test that power is off
before wiring!
Removing existing switch: Remove existing wallplate
and switch mounting screws. Carefully pull switch from wall
box. DO NOT remove wires attached to the switch at this time.
Identifying your wiring application (most
common):
NOTE: If the wiring in the wall box does not resemble any of
these congurations, consult a qualied electrician.
Step 2
Step 4
Step 1
Step 3
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
Single-Pole:
Look at the back of your switch. If there are 2 wires connected to two screw terminals (not including a green or bare copper wire used for grounding), you have a Single-Pole switch.
3-Way:
Look at the back of your switch. If there are 3 wires connected to three screw terminals (not including a green or bare copper wire used for grounding), you have a 3-Way switch. Note that one of the screw terminals will usually be a different color (black) or labeled Common. Tag that wire with electrical tape to identify.
WARNINGS:
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are unsure about any part of these instructions, consult a qualied electrician.
• To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, uorescent lighting, a motor- or a transformer-operated appliance.
• Use with electronic low-voltage transformers only. Do Not use to control a magnetic low-voltage transformer.
Use a Leviton magnetic low-voltage dimmer to control magnetic low-voltage transformers.
• This dimmer provides protection from overheating. An excessive load applied to the dimmer will cause the dimmer to overheat. The excess load must be removed to resume proper operation.
CAUTIONS:
• This dimmer requires a neutral wire connection. If a neutral wire is not in the wall box, consult a qualied electrician.
• Use only one (1) dimmer in a 3- or 4-way circuit. The switch(es) will turn the light on at the brightness level selected at the dimmer.
• Lighting xture and dimmer must be grounded.
• Disconnect power at circuit breaker or fuse when servicing xture.
• Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.
More than
Cat. No. Single Two Devices 2 Devices
6615-P 300W 300W 250W
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE
Tag Common
Screw Wire
Strip 5/8"
Cut
(if necessary)
Strip Gage
5/8"
Press in slot and pull out wire
Two More than
Rating Single Gang 2 Gang 300W 240W 200W 160W
MAXIMUM BULB WATTAGE AT 80% EFFICIENCY
Disconnecting switch wires and preparing wires:
Page 2
Connect wires per WIRING DIAGRAM as follows:
Screw wire nuts on clockwise making sure no bare
conductors show below the wire connectors. Secure each connector with electrical tape.
WARNING: CONNECT AN ELECTRONIC LOW-VOLTAGE
DIMMER ONLY TO THE PRIMARY (HIGH-VOLTAGE) SIDE OF A ELECTRONIC LOW-VOLTAGE TRANSFORMER.
NOTE: Dimmer can be installed on either the Load or Line side.
Green dimmer Ground lead to Green or bare copper
wire in wall box.
• Black dimmer lead to tagged (common) wall box wire identied
when removing old switch.
White dimmer lead to White Neutral wall box wire.
Remove Red insulating label from Red lead.
• Any Red dimmer lead to any of the remaining wall box wires.
Remaining Red dimmer lead to remaining wall box wire.
Testing your Dimmer prior to mounting in wall
box:
Dimmer Mounting:
TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.
Single-Pole Wiring Application using 3-Way
Dimmer:
Connect wires per WIRING DIAGRAM as follows:
Screw wire nuts on clockwise making sure no bare conductors
show below the wire connectors. Secure each connector with electrical tape.
WARNING: CONNECT AN ELECTRONIC LOW-VOLTAGE
DIMMER ONLY TO THE PRIMARY (HIGH-VOLTAGE) SIDE OF A ELECTRONIC LOW-VOLTAGE TRANSFORMER.
Green dimmer Ground lead to Green or bare copper wire in wall box.
• Black dimmer lead to any wall box wire removed from old
switch.
White dimmer lead to White Neutral wall box wire.
• Red dimmer lead without insulating label to remaining wall
box wire.
• Remaining Red dimmer lead should have Red insulation label afxed. Proceed to Step 6. NOTE: If insulating label is not afxed to Red lead, use a small wire nut or electrical tape to cap off. Proceed to Step 6.
3-Way Wiring Application:
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benet of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for ve years from the purchase date. Levitonʼs only obligation is to correct such defects by repair or replacement, at its option, if within such ve year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and tness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and tness for a particular purpose, is limited to ve years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or prots or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
• Restore power at circuit breaker or fuse.
• Carefully holding Dimmer as shown, slide control lever to highest postion. If lights are not ON, press rocker. Lights should turn ON to brightest level.
If lights do not turn ON, refer
to the TROUBLESHOOTING section.
Step 5b
Black
Ta
g
Red
Red
Neutral
Ground
Green
White
Step 6
Step 7
Installation may now be completed by carefully positioning all wires to provide room in wall box for dimmer. Mount dimmer into box with mounting screws supplied. Attach Decora® wallplate.
Restore Power: Restore power at circuit breaker or
fuse. Installation is complete.
OPERATION
NOTE: If using the dimmer in a 3-way application, the lights will
turn ON at the level the slider is set for both single pole and 3-way applications. The lighting can be controlled from either the dimmer or the switch location.
TROUBLESHOOTING
• Lights Flickering
- Lamp has a bad connection.
- Wires not secured rmly with wire connectors.
• Light does not turn ON
- Circuit breaker or fuse has tripped.
- Lamp is burned out.
- Lamp Neutral connection is not wired.
NOTE: If further information is needed in identifying the HOT wire in a 3-Way application, go to Leviton's website at www.leviton.com.
TOP
WIRE NUT / # OF COND.
COMBINATION CHART
1- #12 w/ 1 to 3 #14, #16 or #18 2- #12 w/ 1 or 2 #16 or #18 1- #14 w/ 1 to 4 #16 or #18 2- #14 w/ 1 to 3 #16 or #18
For non-standard wiring applications, refer to
Wire Nut and Conductor Size Chart
Black
Red
Neutral
Green
Ground
Red
This wire is used in 3-way installations only. For single pole installations, do not remove this insulating label.
White
Hot (Black)
Neutral (White)
Line 120VAC, 60 Hz
Black
Red
Dimmer
Green Ground
Red
Insulating
Label
Black
White
Electronic Low-Voltage Transformer
Primary
Side
White
Step 5a
Insert wires
straight then twist clockwise
Insert wires
straight then twist clockwise
TOP
DI-00X-06615-02B
ON: Push rocker switch ON. OFF: Push rocker switch OFF. BRIGHTEN: Raise slider control lever to
desired level of light. DIM: Lower slider control lever to desired
level of light.
Hot (Black)
Neutral (White)
Dimmer
3-Way Switch
Red
Black
Green
Ground
Green
Ground
Red
Line
120VAC, 60Hz
Common Terminal
(Black Screw)
Black
White
Electronic Low-Voltage Transformer
Primary
Side
White
Step 8
Electrical
Tape
Electrical
Tape
Step 5b cont'd