Leviton 47605-ACS, 47605-TRS User Manual

Page 1
47605-ACS 47605-TRS
Instructions for Use Directives d’utilisation Instrucciones de uso
125 VAC Junction Box Kit (with surge protection)
Kit de Caja de Unión de 125 Vca (con supresión)
125 VAC JUNCTION BOX KIT DESCRIPTION
The AC Junction Box Kit, with surge supprestion is an accessory for Leviton’s Structured MediaTM Center (SMC), t features one 15 Amp Industrial Grade SPD (Surge Protection Device) receptacle housed in a white metal enclosure which drops into an opening in the bottom of the SMC. The unit has several cable entry knockouts for power service connections.
OPERATION
The supplied SPD receptacle provides sensitive equipment with protection from transient voltage surges. A green indicator light on the face of the unit, when continuously lit, indicates surge protection
is in a󰀨ect. When the indicator light is o󰀨, the receptacle is no longer providing suppresion. When protection is lost an audible alarm will beep continuously. The alarm may be shut o󰀨 by following the instructions on
the face of the receptacle.
NOTE: The audible alarm can only be shut o󰀨 once and cannot be reset.
CAUTION: ASSEMBLIES MUST BE INSTALLED IN ACCORDANCE WITH ALL
APPLICABLE NEC AND CEC REQUIREMENTS. WHEN AN ALARM CONDITION OCCURS, SURGE PROTECTION IS NO LONGER IN EFFECT AND THE OUTLET NEEDS TO BE REPLACED IMMEDIATELY! DO NOT ATTEMPT TO REPLACE OUTLET WHILE THE CIRCUIT IS ENERGIZED! ELECTRICAL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN. IF THE OUTLET IS NOT REPLACED, IT WILL FUNCTION ONLY AS A CONVENTIONAL OUTLET WITHIN ITS RATING.
© 2020 Leviton Manufacturing Co., Inc. Customer Support: 800.824.3005 International: +1.425.486.2222 Web: www.leviton.com
IMPORTANT SAFETY INSTRUCTIONS––READ BEFORE INSTALLING
Carefully read all installation instructions before beginning your intended
installation. If you do not understand any part of them, consult a qualified electrician. This unit must be installed and/or used in accordance with appropriate electrical codes and regulations.
WARNING: TO AVOID FIRE, SHOCK, OR DEATH: TURN OFF POWER AT
CIRCUIT BREAKERS OR FUSES. TEST CIRCUIT TO MAKE SURE THAT THE POWER IS OFF BEFORE WIRING!
WARNING: THIS DEVICE IS INTENDED FOR SINGLE BRANCH CIRCUIT
INSTALLATIONS ONLY.
WARNING: USE THIS DEVICE ONLY WITH COPPER OR COPPER-CLAD WIRE!
INSTALLATION
1. When positioning the SMC on the wall, ensure the adequate space is provided
for the Junction Box Kit and any associated AC wiring.
2. Remove the rectangular knockout in the bottom of the SMC.
3. Remove a cable entry knockout (A) for electrical service to the Junction Box.
User supplied conduit ttings or cable clamps (B) are recommended to ready the
cable entry holes for electrical wiring. (FIgure 1)
4. Install electrical wiring. An independant 15 Amp circuit should be used to provide
power to the Junction Box Kit.
a. Wire the surge suppressor receptacle as shown in Figure 2.
b. On receptacle, loosen Silver terminal screw (labled “LINE” and “WHITE
WIRE” on the back of the unit). Remove insulation from the white (AC
NEUTRAL) wire according to “strip gauge” on back of device, about 1/2” and
insert the wire into either of the LINE holes marked “WHITE WIRE”. Tighen the SILVER terminal screw rmly.
DI-026-47605-20C
Page 2
c. On recptacle, loosen BRASS colored terminal screw (labeled “LINE” and
“HOT WIRE” on the back of the unit). Remove insulation from the black (AC
LINE) wire according to “strip gauge” on back of device, about 1/2” and insert
the wire into either LINE hole marked “HOT WIRE”. Tighten the BRASS terminal screw rmly.
d. Connect the GREEN or GREEN/YELLOW wire (with insulation stripped
as with the previous wires in step b and c) or BARE AC GROUND wire to the GREEN screw terminal on the receptacle.
5. Drop the Junction Box housing into the opening in the SMC. Attach the Junction Box to the SMC with the four, #6 x 3/8-inch, thread-forming screws provided. Tighten all screws securely.
6. Place the wired receptacle into the housing. Verify that all wiring connections are completely inside the hosuing, without being pinched or otherwise damaged.
7. Attach the receptacle to the Junciton Box with the two, #6-32 X 1/2 inch screws provided.
8. Attach the Decora-style wallplate to the mounted receptacle, using the two provided screws.
9. Safety plugs are included with the unit to keep wire clippings and other foreign matter out of the outlets during installation and when outlets are not in use.
For technical support regarding the 125 VAC Junction Box Kit, please contact Power Quality at 1-800-648-3332; or, for technical assistance regarding the Structured Media Center, please contact technical support at Leviton Voice and Data: 1-800-824-3005.
To view pictures, descriptions, specications, or instruction sheets for the parts
described in this instruction sheet, please visit our website at: www.leviton.com
DI-026-47605-20C
Loading...