LevelOne media converters are Fast Ethernet 100Base-TX to
100Base-FX and 1000Base-T to 1000Base-SX/LX converters to
provide the flexibility required in network integration. The TX port
auto-sense connection speed, auto-negotiates half/full duplex
modes and auto-selects MDIX media type. The fiber connectors
come with multimode or singlemode, SC, ST or SFP connector to
provide necessary connection interface and distance capabilities.
LevelOne have designed 19” racks to organize media converters the
smart way by providing a single power supply. With the
Plug-and-play technology, the converter is easy to set-up and run.
For simple, cost-effective network design, LevelOne converter
series is the perfect solution to bridge the complex network
infrastructure.
1.1. Features
Fast Ethernet Module
Comply with IEEE 802.3, 802.3u, and 802.3x standards.
Convert between UTP cabling and Fiber-optic cabling.
One RJ-45 connector, Auto-MDI/MDIX for UTP port.
Support 10/100 Mbps Auto-negotiation for UTP port.
Fiber cabling connectivity up to 30Km.
Store-and-forward switching to separate two collision domains.
One fiber connector (SC/ ST) for 100Base-FX.
4DIP-switches to set the operation mode
Link- Lost-Forwarding function.
1
Gigabit Ethernet Module
Comply with IEEE 802.3, 802.3u, and 802.3x, IEEE 802.3ab,
1000BaseT, 802.3z, 1000BaseSX/LX standards
Convert between UTP cabling and Fiber-optic cabling.
One RJ-45 connector, Auto-MDI/MDIX for UTP port.
Support 10/100/1000 Mbps Auto-negotiation for UTP port
Fiber cabling connectivity up to 70Km.
Store-and-forward switching to separate two collision domains.
One fiber connector (SC / SFP) for 1000Base-SX/LX
DIP-switches to set the operation mode function.
Link- Lost-Forwarding function.
1.2. Package Contents
- Stand-alone Media Converter
- Power Adapter DC 9V, 0.7A
- User Manual
Compare the contents of your converter module with the checklist
above. If any item is damaged or missing, please contact your local
dealer for service.
2
3
2. Hardware Description
Front Panel
2.1.
FVT-4001 / FVT-4002 / FVT-4301
GVT-4000
GVT-4001
1
2
(1) RJ-45 Port (3) DIP-Switch
(2) LED (4) Fiber/SFP Connector
3
4
2.2. Rear Panel
Power Adapter: DC 9V, 0.7A
The rear panel contains a power socket. This power socket accepts
DC9V voltage and minimum 0.7A supplied current.
4
2.3. LED Indicators
Fast Ethernet Module
LED Status Meaning
PWR Green Power on
100
LK/ACT
(UTP)
LK/ACT
(Fiber)
FDX/COL
(UTP)
FDX/COL
(Fiber)
Green 100Mbps UTP Speed
OFF 10 Mbps UTP Speed
Green The unit is linking with it’s link partner.
Blinks The unit is transmitting or receiving packets
Off No device attached
Green The unit is linking with it’s link partner.
Blinks The unit is transmitting or receiving packets
Off No device attached
Orange The UTP port is operating in full-duplex mode.
Blinks Collision of Packets occurs in the port.
Off Half-duplex mode or no device attached
Orange The fiber port is operating in full-duplex mode.
Blinks Collision of Packets occurs in the port.
Off Half-duplex mode or no device attached
5
Gigabit Ethernet Module
LED Status Meaning
PWR Green Power on
Green 1000Mbps UTP Speed
SPD
LNK/ACT
(UTP)
FDX/COL
(UTP)
LNK/ACT
(Fiber)
FDX/COL
(Fiber)
Orange 100Mbps UTP Speed
OFF 10Mbps UTP Speed
Green The unit is linking with its link partner.
Blinks The unit is transmitting or receiving packets
Off No device attached
Orange The UTP port is operating in full-duplex mode.
Blinks Collision of Packets occurs in the port.
Off Half-duplex mode or no device attached
Green The unit is linking with its link partner.
Blinks
Off No device attached
Orange The fiber port is operating in full-duplex mode.
Blinks Collision of Packets occurs in the port.
Off Half-duplex mode or no device attached
The unit is transmitting or receiving packets from
FX devices.
6
2.4. DIP-switch
The DIP-switch is used to configure operation mode for LLF (Link
Lost Forwarding) and operation mode for UTP/Fiber port. The
default value of DIPswitch is OFF.
Fast Ethernet Module
No Status Description
ON UTP 100Mbps Full Duplex mode
1
OFF UTP Auto-Nego
ON Fiber in Half Duplex
2
OFF Fiber in Full Duplex
ON LLF Enable
3
OFF LLF Disable
ON Pure converter mode
4
OFF Switch Converter mode
Gigabit Ethernet Module
No Status Description
ON Fiber in 1000Mbps Full Duplex
1
OFF Fiber Auto-Negotiation
ON UTP LLF Enable
2
OFF UTP LLF Disable
ON Fiber LLF Enable
3
OFF Fiber LLF Disable
7
Link Lost Forwarding:
When LLF is enable, allow UTP link failures to be reported to the
fiber side and also allow Fiber link failure to be reported to the UTP
side. Therefore, A link loss forward feature is provided in both UTP
and Fiber side.
Pure Converter mode (Fast Ethernet Module):
When pure converter mode is enabling (on), it operates with the
minimum latency. The transmission flow does not wait until entire
frame is ready, but instead it forwards the received data immediately
after the data being received. And TP port should be forced at 100M
in this application. When DIP-Switch is in Switch Converter mode
(off), the converter function is same as Switch Hub.
Note:
Please don’t change the DIP-switch setting when UTP or fiber port is
transmitting or receiving data. It may cause some data error.
8
3. Cabling
Fast Ethernet Module
Twisted-pair segment can be use unshielded twisted pair (UTP)
or shielded twisted pair (STP) cabling. The cable must comply
with the IEEE 802.3u 100Base TX standard for Category 5. The
cable between the converter and the link partner (switch, hub,
workstation, etc.) must be less than 100 meters (328 ft.) long.
Fiber segment using multi-mode connector type must use 50 or
62.5/125 um multi-mode fiber cable. You can connect two
devices up to a 2-kilometer (6,562 ft.) distance.
Fiber segment using single-mode connector type must use
8/125 or 9/125 um single-mode fiber cable. You can connect two
devices in the distance of 30 Kilometers in full duplex operation.
For half-duplex operation, the recommended maximum distance
is 412 meters (1,352 ft.)
Gigabit Ethernet Module
Using four twisted-pair, Category 5 cabling for RJ-45 port
connection. The cable between the converter and the link
partner (switch, hub, workstation, etc.) must be less than 100
meters (328 ft.) long.
Fiber segment using multi-mode connector type must use 50 or
62.5/125 um multi-mode fiber cable. You can connect two
devices up to 550m distances.
Fiber segment using single-mode connector type must use
8/125 or 9/125 um single-mode fiber cable. You can connect two
devices in the distance of 10 Kilometers in full duplex operation.
For half-duplex operation, the recommended maximum distance
is 412 meters (1,352 ft.)
9
Optical Fiber
Module Name Wavelength
100Base-FX Fiber SC MM 1310 (nm)-18 (dB) -30 (dB)
100Base-FX Fiber ST MM 1310 (nm)-18 (dB) -30 (dB)
100Base-FX Fiber SC SM 1310 (nm)-6 (dB) -34 (dB)
1000Base-SX Fiber SC MM 850 (nm) -10 (dB) -17 (dB)
Module Name
100Base-FX Fiber SC MM 12 (dBm) 2 (Km)
100Base-FX Fiber ST MM 12 (dBm) 2 (Km)
100Base-FX Fiber SC SM 28 (dBm) 30(Km)
1000Base-SX Fiber SC MM 7 (dBm) 550 (m)
Avg. Power
Loss Budget
Avg. Launch
Power
Max. FDX
Fiber
Distance
Avg.
Sensitivity
Fiber Size (um)
62.5/125
50/125
62.5/125
50/125
9/125
8/125
62.5/125
50/125
10
4. Specification
Fast Ethernet Module
Standard
Connector
Switch
architecture
Fiber
parameters
Transparent
packet
Link Lost
Forward
DIP Switch
LED
Power DC9V / 0.7A
Dimension 119mm x 85mm x 26mm
EMI & safety CE, FCC Class A
IEEE802.3 10BASE-T
IEEE802.3u 100BASE-TX/100BASE-FX
IEEE802.3x Flow Control and Back pressure
Fiber: Duplex ST/SC
RJ-45 Socket: CAT-3/5 (10/100Mbps)
Twisted Pair cable, Auto MDI/MDI-X, Auto-Negotiation
Store and Forward
Fiber Core: Multi-Mode (62.5/125um, 50/125um)
Single-Mode (8/125um, 9/125um)
Wavelength: 1310nm(Multi-mode)
1310nm(Single-mode)
Fiber Distance: Multi-Mode Fiber 2KM
Single-Mode Fiber (30 KM)
64 to 1600 Bytes for Non-VLAN Ethernet packet
UTPÎFiber: If UTP port link down, then converter will forced
fiber to link down.
Fiber Î UTP: If Fiber port link down, the media converter will
force UTP port to link down.
DIP Switch 1: UTP Auto-Nego / 100Mbps Full Duplex mode
DIP Switch 2: Fiber Full/Half Duplex
DIP Switch 3: LLF (Link Lose Forwarding) Disable/Enable
DIP Switch 4: Switch Converter / Pure converter mode
Power, UTP (100Mbps, LK/Act, FDX/COL)
Fiber (LK/Act, FDX/COL)
Dimension 119mm x 85mm x 26mm
EMI & safety CE, FCC Class A
IEEE 802.3ab 1000BaseT
IEEE 802.3z 1000BaseSX/LX standards
IEEE802.3x Flow Control and Back pressure
(only for GVT-5001 and Giga Fiber port in Auto-Nego mode)
Fiber: SC / SFP
RJ-45 Socket: CAT-5 (10/100/1000Mbps or pure 1000Mbps)
Twisted Pair cable, Auto MDI/MDI-X, Auto-Negotiation
Store and Forward
Fiber Core: Multi-Mode (62.5/125um, 50/125um)
64 to 1536 Bytes for Ethernet packet
UTPÎFiber: If UTP port link down, then converter will forced
fiber to link down.
Fiber Î UTP: If Fiber port link down, the media converter will
force UTP port to link down.
DIP Switch 1: Fiber Auto-Nego/1000Mbps Full Duplex mode
DIP Switch 2: UTP ÎFiber LLF Disable/Enable
DIP Switch 3: FiberÎ UTP LLF Disable/Enable
Power, UTP (SPD, LK/ACT, FDX)
Fiber (LK/Act, FDX/COL)
12
5. Optional SFP Modules
GVT-4000 supports 3.3V mini-GBIC module
Part No. Model No. Description
570622 GVT-0300
Mini-GBIC SFP transceiver
Multi-Mode, 550m
551071 GVT-0301
551072 GVT-0302
Mini-GBIC SFP transceiver
Single-Mode, 10km
Mini-GBIC SFP transceiver
Single-Mode, 70km