LevelOne GVT-4001 User Manual

Copper to Fiber
Stand-Alone Media Converter
User Manual
Part No. Model No. Description
531063 FVT-4001
531052 FVT-4002
531071 FVT-4301
531404 GVT-4000
531402 GVT-4001
10/100Base-TX to 100Base-FX SC, Multi-mode 2km
10/100Base-TX to 100Base-FX ST, Multi-mode 2km
10/100Base-TX to 100Base-FX SC, Single-mode 30km
10/100/1000Base-T to SFP mini-GBIC, 3.3V
10/100/1000Base-T to 1000SX SC, Multi-mode 550m
Ver. 1.00 - 0610
Table of Contents
1. INTRODUCTION................................................1
1.1. FEATURES........................................................... 1
1.2. PACKAGE CONTENTS.......................................... 2
2. HARDWARE DESCRIPTION............................3
2.1. FRONT PANEL .....................................................3
2.2. REAR PANEL.......................................................4
2.3. LED INDICATORS................................................ 5
2.4. DIP-SWITCH........................................................ 7
3. CABLING...........................................................9
4. SPECIFICATION..............................................11
5. OPTIONAL SFP MODULES............................13

1. Introduction

LevelOne media converters are Fast Ethernet 100Base-TX to 100Base-FX and 1000Base-T to 1000Base-SX/LX converters to provide the flexibility required in network integration. The TX port auto-sense connection speed, auto-negotiates half/full duplex modes and auto-selects MDIX media type. The fiber connectors come with multimode or singlemode, SC, ST or SFP connector to provide necessary connection interface and distance capabilities. LevelOne have designed 19” racks to organize media converters the smart way by providing a single power supply. With the Plug-and-play technology, the converter is easy to set-up and run. For simple, cost-effective network design, LevelOne converter series is the perfect solution to bridge the complex network infrastructure.

1.1. Features

Fast Ethernet Module
Comply with IEEE 802.3, 802.3u, and 802.3x standards. Convert between UTP cabling and Fiber-optic cabling. One RJ-45 connector, Auto-MDI/MDIX for UTP port. Support 10/100 Mbps Auto-negotiation for UTP port. Fiber cabling connectivity up to 30Km. Store-and-forward switching to separate two collision domains. One fiber connector (SC/ ST) for 100Base-FX. 4DIP-switches to set the operation mode Link- Lost-Forwarding function.
1
Gigabit Ethernet Module
Comply with IEEE 802.3, 802.3u, and 802.3x, IEEE 802.3ab,
1000BaseT, 802.3z, 1000BaseSX/LX standards
Convert between UTP cabling and Fiber-optic cabling. One RJ-45 connector, Auto-MDI/MDIX for UTP port. Support 10/100/1000 Mbps Auto-negotiation for UTP port Fiber cabling connectivity up to 70Km. Store-and-forward switching to separate two collision domains. One fiber connector (SC / SFP) for 1000Base-SX/LX DIP-switches to set the operation mode function. Link- Lost-Forwarding function.

1.2. Package Contents

- Stand-alone Media Converter
- Power Adapter DC 9V, 0.7A
- User Manual
Compare the contents of your converter module with the checklist above. If any item is damaged or missing, please contact your local dealer for service.
2
3

2. Hardware Description

Front Panel

2.1.
FVT-4001 / FVT-4002 / FVT-4301
GVT-4000
GVT-4001
1
2
(1) RJ-45 Port (3) DIP-Switch (2) LED (4) Fiber/SFP Connector
3
4

2.2. Rear Panel

Power Adapter: DC 9V, 0.7A The rear panel contains a power socket. This power socket accepts
DC9V voltage and minimum 0.7A supplied current.
4

2.3. LED Indicators

Fast Ethernet Module
LED Status Meaning
PWR Green Power on
100
LK/ACT (UTP)
LK/ACT (Fiber)
FDX/COL (UTP)
FDX/COL (Fiber)
Green 100Mbps UTP Speed OFF 10 Mbps UTP Speed Green The unit is linking with it’s link partner. Blinks The unit is transmitting or receiving packets Off No device attached Green The unit is linking with it’s link partner. Blinks The unit is transmitting or receiving packets Off No device attached Orange The UTP port is operating in full-duplex mode. Blinks Collision of Packets occurs in the port. Off Half-duplex mode or no device attached Orange The fiber port is operating in full-duplex mode. Blinks Collision of Packets occurs in the port. Off Half-duplex mode or no device attached
5
Gigabit Ethernet Module
LED Status Meaning
PWR Green Power on
Green 1000Mbps UTP Speed
SPD
LNK/ACT (UTP)
FDX/COL (UTP)
LNK/ACT (Fiber)
FDX/COL (Fiber)
Orange 100Mbps UTP Speed OFF 10Mbps UTP Speed Green The unit is linking with its link partner. Blinks The unit is transmitting or receiving packets Off No device attached Orange The UTP port is operating in full-duplex mode. Blinks Collision of Packets occurs in the port. Off Half-duplex mode or no device attached Green The unit is linking with its link partner.
Blinks
Off No device attached Orange The fiber port is operating in full-duplex mode. Blinks Collision of Packets occurs in the port. Off Half-duplex mode or no device attached
The unit is transmitting or receiving packets from FX devices.
6

2.4. DIP-switch

The DIP-switch is used to configure operation mode for LLF (Link Lost Forwarding) and operation mode for UTP/Fiber port. The default value of DIPswitch is OFF.
Fast Ethernet Module
No Status Description
ON UTP 100Mbps Full Duplex mode
1
OFF UTP Auto-Nego ON Fiber in Half Duplex
2
OFF Fiber in Full Duplex ON LLF Enable
3
OFF LLF Disable ON Pure converter mode
4
OFF Switch Converter mode
Gigabit Ethernet Module
No Status Description
ON Fiber in 1000Mbps Full Duplex
1
OFF Fiber Auto-Negotiation ON UTP LLF Enable
2
OFF UTP LLF Disable ON Fiber LLF Enable
3
OFF Fiber LLF Disable
7
Link Lost Forwarding: When LLF is enable, allow UTP link failures to be reported to the fiber side and also allow Fiber link failure to be reported to the UTP side. Therefore, A link loss forward feature is provided in both UTP and Fiber side.
Pure Converter mode (Fast Ethernet Module): When pure converter mode is enabling (on), it operates with the minimum latency. The transmission flow does not wait until entire frame is ready, but instead it forwards the received data immediately after the data being received. And TP port should be forced at 100M in this application. When DIP-Switch is in Switch Converter mode (off), the converter function is same as Switch Hub.
Note:
Please don’t change the DIP-switch setting when UTP or fiber port is transmitting or receiving data. It may cause some data error.
8

3. Cabling

Fast Ethernet Module
Twisted-pair segment can be use unshielded twisted pair (UTP)
or shielded twisted pair (STP) cabling. The cable must comply with the IEEE 802.3u 100Base TX standard for Category 5. The cable between the converter and the link partner (switch, hub, workstation, etc.) must be less than 100 meters (328 ft.) long.
Fiber segment using multi-mode connector type must use 50 or
62.5/125 um multi-mode fiber cable. You can connect two devices up to a 2-kilometer (6,562 ft.) distance.
Fiber segment using single-mode connector type must use
8/125 or 9/125 um single-mode fiber cable. You can connect two devices in the distance of 30 Kilometers in full duplex operation. For half-duplex operation, the recommended maximum distance is 412 meters (1,352 ft.)
Gigabit Ethernet Module
Using four twisted-pair, Category 5 cabling for RJ-45 port
connection. The cable between the converter and the link partner (switch, hub, workstation, etc.) must be less than 100 meters (328 ft.) long.
Fiber segment using multi-mode connector type must use 50 or
62.5/125 um multi-mode fiber cable. You can connect two devices up to 550m distances.
Fiber segment using single-mode connector type must use
8/125 or 9/125 um single-mode fiber cable. You can connect two devices in the distance of 10 Kilometers in full duplex operation. For half-duplex operation, the recommended maximum distance is 412 meters (1,352 ft.)
9
Optical Fiber
Module Name Wavelength
100Base-FX Fiber SC MM 1310 (nm) -18 (dB) -30 (dB) 100Base-FX Fiber ST MM 1310 (nm) -18 (dB) -30 (dB) 100Base-FX Fiber SC SM 1310 (nm) -6 (dB) -34 (dB) 1000Base-SX Fiber SC MM 850 (nm) -10 (dB) -17 (dB)
Module Name
100Base-FX Fiber SC MM 12 (dBm) 2 (Km) 100Base-FX Fiber ST MM 12 (dBm) 2 (Km) 100Base-FX Fiber SC SM 28 (dBm) 30(Km) 1000Base-SX Fiber SC MM 7 (dBm) 550 (m)
Avg. Power Loss Budget
Avg. Launch Power
Max. FDX Fiber Distance
Avg. Sensitivity
Fiber Size (um)
62.5/125 50/125
62.5/125 50/125
9/125 8/125
62.5/125 50/125
10

4. Specification

Fast Ethernet Module
Standard
Connector Switch
architecture
Fiber parameters
Transparent packet
Link Lost Forward
DIP Switch
LED Power DC9V / 0.7A Dimension 119mm x 85mm x 26mm EMI & safety CE, FCC Class A
IEEE802.3 10BASE-T IEEE802.3u 100BASE-TX/100BASE-FX IEEE802.3x Flow Control and Back pressure Fiber: Duplex ST/SC RJ-45 Socket: CAT-3/5 (10/100Mbps) Twisted Pair cable, Auto MDI/MDI-X, Auto-Negotiation
Store and Forward Fiber Core: Multi-Mode (62.5/125um, 50/125um)
Single-Mode (8/125um, 9/125um)
Wavelength: 1310nm(Multi-mode)
1310nm(Single-mode)
Fiber Distance: Multi-Mode Fiber 2KM
Single-Mode Fiber (30 KM) 64 to 1600 Bytes for Non-VLAN Ethernet packet UTPÎFiber: If UTP port link down, then converter will forced
fiber to link down. Fiber Î UTP: If Fiber port link down, the media converter will force UTP port to link down. DIP Switch 1: UTP Auto-Nego / 100Mbps Full Duplex mode DIP Switch 2: Fiber Full/Half Duplex DIP Switch 3: LLF (Link Lose Forwarding) Disable/Enable DIP Switch 4: Switch Converter / Pure converter mode Power, UTP (100Mbps, LK/Act, FDX/COL) Fiber (LK/Act, FDX/COL)
11
Gigabit Ethernet Module
IEEE802.3 10BASE-T IEEE802.3u 100BASE-TX/100BASE-FX
Standard
Connector Switch
architecture Fiber
parameters Transparent
packet Link Lost
Forward
DIP Switch
LED Power DC9V / 0.7A
Dimension 119mm x 85mm x 26mm EMI & safety CE, FCC Class A
IEEE 802.3ab 1000BaseT IEEE 802.3z 1000BaseSX/LX standards IEEE802.3x Flow Control and Back pressure (only for GVT-5001 and Giga Fiber port in Auto-Nego mode) Fiber: SC / SFP RJ-45 Socket: CAT-5 (10/100/1000Mbps or pure 1000Mbps) Twisted Pair cable, Auto MDI/MDI-X, Auto-Negotiation
Store and Forward Fiber Core: Multi-Mode (62.5/125um, 50/125um)
Wavelength: 1310nm(Multi-mode) Fiber Distance: 550M (Multi-Mode Fiber)
64 to 1536 Bytes for Ethernet packet UTPÎFiber: If UTP port link down, then converter will forced
fiber to link down. Fiber Î UTP: If Fiber port link down, the media converter will force UTP port to link down. DIP Switch 1: Fiber Auto-Nego/1000Mbps Full Duplex mode DIP Switch 2: UTP ÎFiber LLF Disable/Enable DIP Switch 3: FiberÎ UTP LLF Disable/Enable Power, UTP (SPD, LK/ACT, FDX) Fiber (LK/Act, FDX/COL)
12

5. Optional SFP Modules

GVT-4000 supports 3.3V mini-GBIC module
Part No. Model No. Description
570622 GVT-0300
Mini-GBIC SFP transceiver Multi-Mode, 550m
551071 GVT-0301
551072 GVT-0302
Mini-GBIC SFP transceiver Single-Mode, 10km
Mini-GBIC SFP transceiver Single-Mode, 70km