Note: These instructions must be read fully before commencing use of the heater.
Please retain these instructions for future reference.
FOR INDOOR USE ONLY
Levanté - DN4 5FB, UK
LEV0549_ECOPANELS_Instructions Manual.indd 1 03/07/2018 14:17
LEV0549/Page 1 of 8/Issue 1/07.18
levante-products.com
IMPORTANT SAFEGUARDS
Before use, please read and follow these instructions carefully, even if you feel you are familiar with the product. They contain important information concerning the operation, safety and maintenance when using the product. Please retain these instructions for future use and reference.
When first installed you may experience a burning smell or a little smoke, this is normal and will fade within a few minutes.
The surface temperature of this heater can be very hot, do not touch when the heater is turned on.
Only connect the product if the voltage indicated on the product label(s) corresponds with the mains voltage.
The heater must not be located directly below a wall socket.
Do not unplug the product by pulling on the cord. To unplug grasp the plug, not the cord.
This product has an overheat protection safeguard that turns off the heater whenever it begins to overheat. If it does overheat switch off the heater, remove mains plug from wall socket and allow to cool down for 45 minutes. The heater will work again when cooled. Carefully check prior to using again that the reason for overheating was not curtains, clothing, furniture etc covering any of the heaters air vents.
Turn off the appliance and unplug from socket when not in use. Allow to cool down prior to cleaning. Use a damp cloth for clean and a dry cloth to dry. Do not use cleaning chemicals.
Do not use the product in areas where petrol, paint or flammable liquids are used or stored.
If the power cord is damaged it must be replaced by a service agent or a equivalent qualified electrician. Do not continue to use until repaired, as it may cause a hazard.
This appliance is not intended to be used by young children or disabled persons unless they have been adequately supervised by a responsible adult to ensure the appliance is used correctly and safely.
Young children should be supervised to ensure they do not play with the product.
To protect against fire, electrical shock and injury to persons, do not immerse the appliance power cord or plug in water or other liquid.
This appliance is intended for use indoor only. Avoid overheating do not cover the heater with towels, curtains, clothing etc.
Never use the heater to dry clothing or similar items, or handle the plug with wet hands.
Ensure the heater is installed so that the switches and other controls cannot be touched by a person in the bath or shower.
Ensure the appliance is securely fixed to the wall and is correctly positioned level. The appliance should be placed no less than 150mm from a barrier/wall on all sides - top, bottom, left and right.
Always unplug, wait for appliance to cool down, and store if not to be used for prolonged periods of time.
Models covered by this instruction guide:
ECOPANELS500
Suggested room size: up to 5m Dimensions: 385 x 280 x 72mm
ECOPANELS1000
Suggested room size: 5 - 10m Dimensions: 540 x 280 x 72mm
ECOPANELS1500
Suggested room size: 10 - 15m Dimensions: 790 x 280 x 72mm
ECOPANELS2000
Suggested room size: 15 - 20m Dimensions: 1140 x 280 x 72mm
LEV0549_ECOPANELS_Instructions Manual.indd 2 03/07/2018 14:17
- 500W c/w digital programmer
- 1000W c/w digital programmer
- 1500W c/w digital programmer
- 2000W c/w digital programmer
2
2
2
2
Warning
In order to avoid overheating, do not cover the heater.
LEV0549/Page 2 of 8/Issue 1/07.18
levante-products.com
INSTALLATION GUIDE
1. When mounting the heater on to the wall ensure the heater is unplugged from the mains socket and all power switches are turned off. A suitable wall mounting area requires at least 150mm of empty clearance on ALL four sides.
3. Position the bracket on the wall in the desired location and mark the holes on the wall for drilling, making sure the bracket is level. Drill holes to a suitable depth and secure the mounting bracket to the wall with the four mounting screws supplied. For masonry walls use the wall plugs with screws provided.
2. Detach the mounting bracket from the back of the panel heater by pushing down on the top bracket and then pulling the top brackets out. The bottom section will then slide down and out, releasing the mounting bracket.
4. Hang up the heater on the brackets and secure; Firstly locate the heater onto the lower bracket and push back to locate and click the upper brackets into position. Check heater is secure and plug heater into mains socket.
LOT20 Compliant
Item Symbol Value Unit
HEAT OUTPUT - ECOPANELS500
Nominal Heat Output P
Minimum Heat Output (Indicative) P
Maximum Continuous Heat Output P
HEAT OUTPUT - ECOPANELS1000
Nominal Heat Output P
Minimum Heat Output (Indicative) P
Maximum Continuous Heat Output P
HEAT OUTPUT - ECOPANELS1500
Nominal Heat Output P
Minimum Heat Output (Indicative) P
Maximum Continuous Heat Output P
HEAT OUTPUT - ECOPANELS2000
Nominal Heat Output P
Minimum Heat Output (Indicative) P
Maximum Continuous Heat Output P
AUXILIARY ELECTRICITY CONSUMPTION
At Nominal Heat Output el
At Minimum Heat Output el
In Standby Mode el
0.50 kW
nom
0.25 kW
min
0.48 kW
max,c
1.00 kW
nom
0.50 kW
min
0.90 kW
max,c
1.50 kW
nom
0.75 kW
min
1.40 kW
max,c
2.00 kW
nom
1.00 kW
min
1.90 kW
max,c
N/A kW
max
N/A kW
min
0.00 kW
SB
Item Unit
Type of heat input, for electric storage local space heaters only (Select one)
Manual Heat Charge Control, with Integrated Thermostat [No]
Manual Heat Charge Control with Room and/or Outdoor Temperature Feedback [No]
Electronic Heat Charge Control with Room and/or Outdoor Temperature Feedback [No]
Fan Assisted Heat Output [No]
Type of heat output/room temperature control (Select one)
Single Stage Heat Output and No Room Temperature Control [No]
Two or More Manual Stages, No Room Temperature Control [No]
With Mechanical Thermostat Room Temperature Control [No]
With Electronic Room Temperature Control [No]
Electronic Room Temperature Control Plus Day Timer [No]
Electronic Room Temperature Control Plus Week Timer [Yes]
Other control option (Multiple selections possible)
Room Temperature Control, with Presence Detection [No]
Room Temperature Control, with Open Window Detection [Yes]
With Distance Control Option [No]
With Adaptive Start Control [No]
With Working Time Limitation [No]
With Black Bulb Sensor [No]
LEV0549/Page 3 of 8/Issue 1/07.18