Leuze electronic IT 6300 DPM Quick Start User Manual

Page 1
Leuze electronic
IT 6300 DPM 2D-code hand-held scanner
Quick start user's guide
Page 2
Leuze electronic
Preface
We congratulate you on the purchase of one of the most powerful hand-held scanners. This document is intended to provide information on the handling and use of the IT 6300 DPM produced by Leuze electronic. It includes explanations of the most important information necessary for operation. In addition, the most important connection types are explained and information is provided on programming with the aid of codes. Additional information can be found in the online help system, which is installed together with the setup tool.
Contents
PREFACE ....................................................................................................................................................................... 2
CONTENTS .................................................................................................................................................................... 2
SCOPE OF DELIVERY ................................................................................................................................................ 3
IT 6300 P
INSTALLATION ........................................................................................................................................................... 3
Switching off the computer ....................................................................................................................................... 3
C
ONNECTING THE HAND-HELD SCANNER ...................................................................................................................... 3
Connecting the cable for the IT 6300....................................................................................................................... 4
Testing the scanner................................................................................................................................................... 4
SPECIFICATIONS ........................................................................................................................................................ 4
P
IN ASSIGNMENTS OF THE CONNECTION CABLE............................................................................................................. 4
TTL-RS232 cable/ext IT 6300 Part No. 501 05422 ................................................................................................ 4
PS2 cable/ext IT 6300 Part No. 50105424 ............................................................................................................. 5
USB cable IT 4xxx Part No. 50103404................................................................................................................... 5
R
EADING FIELDS ........................................................................................................................................................... 6
IT 6300 DPM............................................................................................................................................................ 6
RESETTING THE IT 6300 TO FACTORY SETTINGS ........................................................................................... 7
CONFIGURATION ....................................................................................................................................................... 7
IT 6300
With voltage supply via power supply unit with TTL-RS232 cable/ext IT 6300 Part No. 50105422........................ 8
Configuration for the Leuze standard protocol........................................................................................................ 9
IT 6300 IT 6300 IT 6300 IT6300 IT 6300 IT 6300 T T
TO PS2 INTERFACE ......................................................................................................................................... 12
RIGGER...................................................................................................................................................................... 15
ROUBLESHOOTING .................................................................................................................................................... 15
ART NO. 50105380............................................................................................................................... 3
ON THE SERIAL PC INTERFACE......................................................................................................................... 8
ON MA 41 DP-K OR MA 41 IS....................................................................................................................... 9
ON MA 41 DP-K OR MA 41 IS..................................................................................................................... 10
TO MA 21...................................................................................................................................................... 11
TO USB INTERFACE (KEYBOARD EMULATION) .............................................................................................. 13
TO USB INTERFACE (COM PORT EMULATION).............................................................................................. 14
TYPE OVERVIEW...................................................................................................................................................... 16
ACCESSORIES............................................................................................................................................................ 16
C
ONNECTING TO LEUZE MULTINET PLUS .................................................................................................................... 17
C
ONNECTING TO PROFIBUS ......................................................................................................................................... 17
ONNECTING TO INTERBUS......................................................................................................................................... 17
C
Short instructions IT 6300 Leuze electronic Page
2
Page 3
Leuze electronic
CODES FOR FAST CONFIGURATION .................................................................................................................. 18
Scope of delivery
IT 6300 Part No. 50105380
1. Hand-held scanner IT 6300 IDP 351 S
2. CD-ROM
An overview of the types can be found on page 16
For accessories, see page 16
Installation
Switching off the computer
Information on switching off and shutting down the connected computer - which must always be performed before connecting peripheral devices, such as a scanner - can be found in the appropriate operating instructions for your computer.
Connecting the hand-held scanner
Shown in the figure below are the individual steps for installing the cable on the scanner; these steps are described in the following.
Cable latch
Fastening clip
Short instructions IT 6300 Leuze electronic Page
3
Page 4
Leuze electronic
Connecting the cable for the IT 6300
1. To secure the interface cable to the scanner, proceed as follows: plug the RJ 41 connector into the socket on the bottom of the hand-held scanner, now use a Phillips screwdriver to secure the supplied clip for locking the cable.
2. Connect the interface cable to the appropriate connection socket on the computer.
3. You will need a power supply unit for the voltage supply. Connect this power supply unit to the interface cable.
4. Connect the power supply unit to the power socket.
5. Check the operational readiness of the scanner by pointing the scanning surface towards a flat surface and pulling the trigger. A green target line as well as the red illumination should now be visible. Now scan a sample label. The scanner emits an audible signal to confirm that the label has been read; if necessary, the data are now passed on to the computer.
Testing the scanner
The adjacent bar code is for testing the scanner, the module size is 0.5 mm (20 mil)
Code 39 bar code sample
Specifications
The technical data can be found in the data sheet for the IT 6300.
Pin assignments of the connection cable
TTL-RS232 cable/ext IT 6300 Part No. 501 05422
Pin assignments of the 9 pin D-sub socket (female) for cable 42206139-04
Pin number Signal Designation
1 Shield Shield 2 TX Transmit data 3 RX Receive data 5 GND Signal ground 7 CTS Clear to send 8 RTS Request to send
Pin at power supply unit
connection
1 VCC IN 4.5…12 V DC 2 GND Ground
Signal Designation
The proper power supply unit for the IT 6300 (230V/50Hz) has part no. 501 03403.
Short instructions IT 6300 Leuze electronic Page
4
Page 5
Leuze electronic
PS2 cable/ext IT 6300 Part No. 50105424
Pin assignments of the Mini DIN socket or connector for cable 42206416-01
Pin connector Pin socket Signal Designation
1 - PC data PC data line 2 2 NC Not used 3 3 GND Signal ground 4 4 VCC IN 5 Volts DC 5 - PC Clock PC clock line 6 6 NC Not used
- 1 KB Data Keyboard data line
- 2 KB Clock Keyboard clock line
Pin at power supply unit
connection
1 VCC IN 4.5…12 V DC 2 GND Ground
The proper power supply unit for the IT 6300 (230V/50Hz) has part no. 501 03403.
USB cable IT 4xxx Part No. 50103404
Pin assignments of USB type A connector for cable 42206132-03
USB type A connector Signal Designation
1 VCC IN 5 Volts DC 2 Data - Data line ­3 Data - Data line + 4 GND Signal ground
Pin at power supply unit
connection
1 VCC IN 4.5…12 V DC 2 GND Ground
Signal Designation
Signal Designation
The proper power supply unit for the IT 6300 (230V/50Hz) has part no. 501 03403.
Short instructions IT 6300 Leuze electronic Page
5
Page 6
Reading fields
IT 6300 DPM
Leuze electronic
Short instructions IT 6300 Leuze electronic Page
6
Page 7
Leuze electronic
Resetting the IT 6300 to factory settings
To reset all parameters to factory settings, scan the bar code shown below.
Attention: All settings are lost!!!
Configuration
The hand-held scanner can always be configured using bar codes. To do this, first select the bar code in the manual and then actuate the trigger button in order to read the code. The configuration is then immediately accepted and executed. Several of the most important configurations are listed in the following.
A second option is to configure the hand-held scanner with the USB and RS232 interfaces with the aid of the "6300 Series Setup Tool" PC program. You can download and install this program from our homepage at www.leuze.de. The program can be used to make settings and transfer them to the hand-held scanner. The configuration can also be stored so that it can be reused at a later time.
The standard applications are described in the following; each is summarised on a separate page.
Short instructions IT 6300 Leuze electronic Page
7
Page 8
Leuze electronic
IT 6300 on the serial PC interface
With voltage supply via power supply unit with TTL-RS232 cable/ext IT 6300 Part No. 50105422
Please connect the IT 6300 acc. to the adjacent figure.
Required parts: 1x 501 05 380 IT 6300 IDP 315S 1x 501 05 422 Cable TTL-RS232/ext for IT 6300 1x 501 03 403 Power supply unit
Pin assignments of the 9 pin D-sub socket (female) for cable 42206139-04
Pin number Signal Designation
1 Shield Shield 2 TX Transmit data 3 RX Receive data 5 GND Signal ground 7 CTS Clear to send 8 RTS Request to send
Pin at power supply unit
connection
1 VCC IN 4.5…12 V DC 2 GND Ground
Signal Designation
The proper power supply unit for the IT 6300 (230V/50Hz) has part no. 501 03403. RS 232 transmission with 38400 baud, 8 data bits, 1 stop bit, no parity, postfixes CR/LF.
Short instructions IT 6300 Leuze electronic Page
8
Page 9
Leuze electronic
Configuration for the Leuze standard protocol
Leuze standard protocol: RS 232 with 9600 baud, 8 data bits, 1 stop bit, no parity, prefix STX and postfixes CR/LF
Factory setting
Return the IT 6320 to the base station to apply the settings. This procedure is concluded with audible confirmation signals.
To configure the device, please scan the codes in the specified order. The read operation is confirmed by an audible signal.
RS 232 interface
RS 232 baud rate: 9600 baud d
Prefix STX e
The setup tool must be used in order to configure the prefix. The following settings must be performed:
Activate the Formatting Enabled check box.
Please enter \002 in the Leading Text field.
Select Full string and click Add.
Activate the CR/LF check box.
c
Short instructions IT 6300 Leuze electronic Page
9
Page 10
Leuze electronic
IT 6300 on MA 41 DP-K or MA 41 IS
RS 232 transmission with 9600 baud, 8 data bits, 1 stop bit, no parity, postfixes CR/LF.
Required parts: 1x 501 05 380 IT 6300 IDP 315 S 1x 501 05 422 Cable TTL-RS232/ext for IT 6300 1x 501 03 403 Power supply unit 1x 500 35 421 KB 021 Z 1x 500 33 638 MA 41 DP-K for Profibus
(for Interbus: 500 28 994 MA 41 IS or 500 30 085 MA 41 IS PDP)
Pin assignments KB021 Z
Core colour Signal Terminal in MA 41: brown (RXD) 2 white (TXD) 1 blue (GND) 4 red (VCC) black (GND) bare (shield) (PE) 21
 
Please connect the IT 6300 acc. to the figure below.
Configuration
Connection to MA41 in standard setting
Short instructions IT 6300 Leuze electronic Page
10
Page 11
Leuze electronic
IT 6300 to MA 21
RS 232 transmission with 9600 baud, 8 data bits, 1 stop bit, no parity, postfixes CR/LF.
Required parts: 1x 501 05 380 IT 6300 IDP 351S 1x 501 05 422 Cable TTL-RS232/PIN9 IT 6300 1x 501 03 403 Power supply unit 1x 500 35 421 KB 021 Z 1x 500 30 481 MA 21 100
Pin assignments KB021 Z
Core colour: Signal Terminal in MA 21: brown (RXD) 26 white (TXD) 27 blue (GND) 28 red (VCC) 30 black (GND) 31 bare (shield) (PE) 21
Please connect the IT6300 acc. to the figure below.
Configuration
Connection to MA21
with 9600 baud, 8 data bits, 1 stop bit, no parity,
postfixes CR/LF.
Please make these settings on the MA 21.
Short instructions IT 6300 Leuze electronic Page
11
Page 12
Leuze electronic
IT6300 to PS2 interface
The operation of the IT 6300 in keyboard-wedge mode is described in this chapter. A PC keyboard is emulated in this operating mode. The data which are read in are written directly to the currently activated program. Thus, the data can be processed further in all standard programs.
Required parts: 1x 501 05 380 IT 6300 IDP 351S 1x 501 05 424 Cable PS2 for IT 6300 1x 501 03 403 Power supply unit
Please connect the IT 6300 acc. to the adjacent figures.
To do this, proceed as follows:
1. Switch off the PC.
Disconnect
2. Disconnect the keyboard.
3. Plug in the IT 6300 hand-held scanner between the keyboard and the PC.
4. Switch the PC back on.
5. Scan the code shown below.
Configuration
PS2 keyboard emulation with CR LF
German keyboard
Short instructions IT 6300 Leuze electronic Page
12
Page 13
Leuze electronic
IT 6300 to USB interface (keyboard emulation)
The operation of the IT 6300 in keyboard-emulation mode on a USB port is described in this chapter. A PC keyboard is emulated in this operating mode. The data which are read in are written directly to the currently activated program. Thus, the data can be processed further in all standard programs.
Required parts: 1x 501 05 380 IT 6300 IDP 351S 1x 501 05 426 USB cable for IT 6300 1x 501 03 403 Power supply unit
Please connect the IT6300 acc. to the figures below.
To do this, proceed as follows:
1. Plug the IT 6300 hand-held scanner into a free USB port.
2. The scanner acknowledges this connection with a beep.
3. Scan the code shown below.
Configuration
USB keyboard emulation with CR LF
Short instructions IT 6300 Leuze electronic Page
13
Page 14
Leuze electronic
IT 6300 to USB interface (COM port emulation)
The operation of the IT 6300 as a serial interface on a USB port is described in this chapter. A COM interface is emulated in this operating mode. The data which are read in are sent to a new COM interface. The driver with which you emulate this COM interface can be found on the CD-ROM or can be downloaded from our homepage at www.leuze.de. Thus, the data can be processed further in programs which expect data via COM interfaces.
Required parts: 1x 501 05 380 IT 6300 IDP 351S 1x 501 05 426 USB cable for IT 6300 1x 501 03 403 Power supply unit
Please connect the IT 6300 acc. to the figures shown below.
To do this, proceed as follows:
1. Plug the IT 6300 hand-held scanner into a free USB port.
2. The scanner acknowledges this connection with a beep.
3. Scan the code shown below.
4. Install the USB serial driver when you are prompted to do so by Windows.
5. Open a terminal program or your program for the serial interface, select the new COM port, and make the following settings: baud rate 38400, 8 data bits, 1 stop bit and no parity. A CR is still transmitted as terminator.
Configuration
COM port emulation on the next free COM address with 38400 baud,
8 data bits, 1 stop bit, no parity and a CR as postfix.
Short instructions IT 6300 Leuze electronic Page
14
Page 15
Leuze electronic
Trigger
To activate the read process, a trigger signal is to be sent via the serial RS 232 interface or USB interface (COM port emulation only). The command is to be sent at the set baud rate, parity, and data and stop bits. The command for activation is: + To cancel read readiness, send a deactivation.
The command for deactivation is: Following a successful read operation, the IT 6300 deactivates itself.
The second option is to use the trigger button to establish read readiness.
Troubleshooting
For problem detection and troubleshooting, examine your scanner as follows:
1. Is the scanner supplied with power via the interface cable? For power to be supplied, the scanner and computer must be connected to one another before the scanner is commissioned, whereby the computer must provide a power supply of 5 volt DC for the scanner. Check the manual for your computer to ensure that the power supply is adequate for connecting your scanner.
2. Make certain that the interface cable is securely connected to the computer. You can find information on properly connecting the scanner in the manual for your computer. Support is also available from your technical staff.
ASCII decimal value: 043
- ASCII decimal value: 045
3. If your system operates with an external voltage supply, make certain that the power supply unit is securely connected to the scanner and power supply.
4. Check that the interface cable is securely connected to the handle of the scanner. To do this, loosen the Phillips screw on the end cap of the handle with a suitable screwdriver. Remove the cable fastening clip and pull out the cable. Now guide the cable back in and make certain that it is properly seated in the bracket. Remount the fastening clip and secure everything with the Phillips screw. With the IT 4600, please loosen the cable with a small pin: the plug is unlocked by inserting the pin into the hole in the side of the end cap.
5. If, even after performing all of these measures, the scanner is not ready for operation, replace the power supply unit with a different recommended power supply unit which you are certain functions properly.
6. Make certain that your scanner's interface is compatible with the computer. Further information on this topic can be found in the manual for your computer. Also check whether the scanner has been configured for the desired application. This information is described in the online help system for the setup tool.
7. Check whether the bar code labels which you would like to scan are of suitable quality and that the used bar code symbol is recognised by your scanner. Sample labels for testing are available from your dealer should you require precise information on the label details. Damaged bar code labels (crinkled, torn or soiled) may be recognised poorly or not at all by the scanner. If you suspect that the problem lies with the quality of the label, check the read readiness with a label of relatively good quality.
8. If the problems are still not corrected, please contact Leuze electronic.
Short instructions IT 6300 Leuze electronic Page
15
Page 16
Leuze electronic
Type overview
IT Reihe / IT series
Part No. Bezeichnung/Description Schnittstelle/Interface Bild/Picture
Industrie-Handleser (IP54) für direktmarkierte 2D-Codes
Industrial hand-held scanner (IP54) for DPM 2D-codes
50103405 IT 6300 IDP 351S
Alle Geräte werden ohne Kabel geliefert, Bitte separat bestellen! / All devices are delivered without cables, please order separately!
PS2 / USB / TTL RS232
Accessories
Zubehör für IT Reihe / Accessories for the IT series
IT 6300 IDP 315S
Part No. Bezeichnung/Description
50105424 PS2-Kabel/ext IT 6300
PS2 cable/ext for IT 6300
50105426 USB-Kabel/ext IT 6300
USB cable/ext for IT 6300
P/N no.
42206132-
02S
42206461-
01
Bild/Picture
-
-
50105422 TTL-RS232-Kabel/ext IT 6300
TTL-RS232 cable/ext for IT 6300
50103403 Netzteil für IT 4600/4800/IT4715/6300
Power supply for IT4600/4800/IT4715/6300
for ext. cable (5 V DC)
Short instructions IT 6300 Leuze electronic Page
42204253-
04
PS5U-4 + 77900508
X
X
16
Page 17
Connecting to Leuze multinet Plus
MA 21 100 Interface converter / Multinet slave Part No. 500 30 481
KB 021 Z Connection cable MA 21 to IT4600/4800 Part No. 500 35 421
Connecting to Profibus
MA 41 DP-K Profibus gateway Part No. 500 33 638
KB 021 Z Connection cable MA 21 to IT4600/4800 Part No. 500 35 421
Connecting to Interbus
MA 41 IS Interbus gateway Part No. 500 28 994
Leuze electronic
MA 41 IS PDP Interbus gateway with long data protocol Part No. 500 30 085
KB 021 Z Connection cable MA 21 to IT4600/4800 Part No. 500 35 421
Short instructions IT 6300 Leuze electronic Page
17
Page 18
Codes for fast configuration
Reset scanner to factory setting
Reboot scanner
Only activate setup 1 (default)
Leuze electronic
Only activate setup 2
Only activate setup 3
Only activate setup 4
Activate USB keyboard
Activate keyboard wedge (default)
Activate keyboard emulation
Short instructions IT 6300 Leuze electronic Page
18
Page 19
Activate USB-COM
Activate RS-232 interface
RS232: 9600 baud
RS232: 19200 baud
Leuze electronic
RS232: 38400 baud
RS232: 57600 baud
RS232: 115200 baud (default)
8 data bits, even parity, 1 stop bit
8 data bits, no parity, 1 stop bit (default)
8 data bits, odd parity, 1 stop bit
Short instructions IT 6300 Leuze electronic Page
19
Page 20
Hardware handshake RTS/CTS off (default)
Hardware handshake RTS/CTS on
Keyboard layout USA (default)
Keyboard layout Germany
Leuze electronic
Keyboard layout France
Leuze electronic GmbH+Co.KG
Postfach 1111 In der Braike 1 73277 Owen/ Teck, Germany Tel +49 (07021) 573-0 Fax +49 (07021) 573-199 E-mail: info@leuze.de
http://www.leuze.de
Kurzanleitung IT6300-v2.doc
06.2006
Short instructions IT 6300 Leuze electronic Page
20
Loading...