Leuze electronic IT 1900 User Manual

Page 1
5 V DC
A Cable entry:
depending on the cable, max. Ø 20mm, cable-Ø 5mm
Specifications and description
IT 1900 2D-code hand-held scanner
Dimensioned drawing
en 01-2011/04 50115720
z Hand-held scanner for Data-Matrix Codes
and Bar Codes
z Large reading field for the detection of high-
contrast codes
z Robust trigger button z Built-in decoder z Read-display z RS 232, USB and PS/2 interface z Operating temperature from 0 through 50°C z Larger reading field through higher resolu-
tion and improved decoding
Accessories
z RS 232 cable
part no. 50115105
z TTL-RS 232 cable
part no. 50114517
z PS/2 cable
part no. 50114519
z USB cable, 3m
part no. 50114521
z USB helix cable, 5m
part no. 50114523
z Power supply unit
part no. 50114525
We reserve the right to make changes • PAL_IT1900_en.fm
Electrical connection
for RS 232 cable
9-pin Sub-D Signal
2TXD 4 3RXD 5 5 GND external 3 7CTS 6 8RTS 8 9 5V DC internal 7
for USB cable
USB type A Signal IT 1900 RJ41
15VDC7 2Data -10 3Data +9 4GND3
for PS/2 cable
Mini DIN connector Mini DIN socket Signal IT 1900 RJ41
1-PC Data4 22NC 33GND3 445VDC7 5-PC Clock5 66NC
- 1 KB Data 8
-5KB Clock6
Connection for power supply
unit
IT 1900 RJ41
Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 info@leuze.de • www.leuze.com
IT 1900 - 01
Page 2
IT 1900g HD-2 IT 1900g SR-2
Typ. read distance 1) [mm]
0 200 400 600100 300 500 700
5 Mil (0.127 mm)
Code 39
PDF 417
Data Matrix
QR Code
UPC
13 Mil (0.330 mm)
20 Mil (0.508 mm)
6,7 Mil (0.170 mm)
10 Mil (0.254 mm)
20 Mil (0.508 mm)
Code 39
IT 1900g ER-2
1) Dependent on code module
Typ. read distance
1)
[mm]
Typ. read distance
1)
[mm]
IT 1900
Specifications
Electrical data
Operating voltage U Power consumption max. 2,3W
B
4…5.5VDC
Interfaces
Interface type RS 232, PS/2 and USB Trigger via button or serial command
Code types
2D codes Data Matrix ECC 200, MaxiCode, PDF417, MicroPDF, QR Code,
Bar codes 2/5 Interleaved, Code 39, Code 128, Code 93, Codabar, UPC/
Aztec, Aztec Mesas, Code 49, EAN/UCC Composite
EAN, Codablock, GS1 Databar
Optical data
Optical system high-resolution pixel array 838x640 Symbol contrast PCS 20% minimum Light source integrated diffuse LED, wavelength 617nm ± 18nm Read direction omnidirectional, various tilt and rotational angles
up to 45°
Mechanical data
Weight 147 g (without cable) Dimensions 104x71 x 160 mm Shock resistance 50 falls from a height of 1.8m
Environmental data
Ambient temp. (operation/storage) 0°C … +50°C/-40 °C … +70 °C Relative air humidity 0 … 95% (non-condensing) Protection class IP 41
Reading field
5 Mil
Code 39
(0.127 mm)
13 Mil
UPC
(0.330 mm)
6,7 Mil (0.170 mm)
10 Mil (0.254 mm)
20 Mil (0.508 mm)
20 Mil (0.508 mm)
Code 39
PDF 417
Data Matrix
QR Code
0 200 400 600100 300 500 700
5 Mil
Code 39
(0.127 mm)
UPC
Code 39
6,7 Mil
PDF 417
(0.170 mm)
Data Matrix
QR Code
0 200 400 600100 300 500 700
10 Mil (0.254 mm)
13 Mil (0.330 mm)
20 Mil (0.508 mm)
20 Mil (0.508 mm)
Tables
Diagrams
2D code hand-held scanner (special optics for very small codes) Part No.
IT 1900g HD-2 with RS 232, PS/2 and USB interface 50114507
2D-code hand-held scanner (standard range) Part No.
IT 1900g SR-2 with RS 232, PS/2 and USB interface 50114509
2D code hand-held scanner (special optics with large range) Part No.
IT 1900g ER-2 with RS 232, PS/2 and USB interface 50114504
IT 1900 - 01 2011/04
Order guide
Remarks
Ergonomically shaped hand­held scanner with integrated decoder for high-contrast codes.
Data transmission via config­urable RS 232 interface.
Or keyboard-wedge opera­tion via PS/2 or USB inter­face.
Page 3
Cable latch
IT 1900
IT 1900 2D-code hand-held scanner
Switching off the computer
Information on switching off and shutting down the connected computer - which must always be performed before connecting peripheral devices, such as a scanner - can be found in the appropriate operating instructions for your computer.
Connecting the IT 1900
Shown in the adjacent figure is the location of the cable connection and trigger button of the scanner. The individual steps for installing the cable on the scanner are described below.
1.To secure the interface cable to the scanner, proceed as follows: Insert the RJ 41 connector into the socket on the bottom of the hand-held scanner until the connector engages. Connect the interface cable to the appropriate connection socket on the com­puter.
2.You may need a power supply unit for supplying voltage; alternatively, you can use a cable which supplies voltage from the computer system. Use the pin assignments (see "Electrical connection" on page 1) to select the appropriate cable for your application.

3.Connect the power supply unit to the power socket (not necessary if voltage is supplied from the computer).

4.Check the operational readiness of the scanner by pointing the scanning sur­face towards a flat surface and pulling the trigger. A red target line as well as the red illumination should now be visible. Now scan a sample label. The scanner emits an audible signal to confirm that the label has been read; if necessary, the data are now passed on to the computer.
Configuration
The hand-held scanner can always be configured using bar codes. To do this, the barcode must first be selected on the package insert and then the trigger actuated in order to read the code. The configuration is then immediately accepted and executed.
Several of the most important configurations are listed in the following.
A second option is to configure the hand-held scanner with the USB and RS232 interfaces with the aid of the EZ Config PC program. You can download and install this program from our homepage at www.leuze.de The program can be used to make settings and transfer them to the hand-held scanner. The configuration can also be stored so that it can be reused at a later time.
Further information on this can be found in the User's Guide for the IT 1900/1902.
The standard applications are described and summarised below.
Notice!
Additional information on the device and short instructions can be found on the Internet at www.leuze.de.
.
Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 IT 1900 - 01 info@leuze.de • www.leuze.com
Page 4
IT 1900
Resetting the IT 1900 to factory settings
To reset all parameters to factory settings, scan the adjacent barcode.
Attention!
All settings are lost!!!
Trigger
To activate the read process, a trigger signal is to be sent via the serial RS 232 interface or USB interface (COM port emulation only). The command is to be sent at the set baud rate, parity, and data and stop bits.
The command for activation is: SYN T CR ASCII decimal values: 022; 084; 013
To cancel read readiness, send a deactivation.
The command for deactivation is: SYN U CR ASCII decimal values: 022; 085; 013
Following a successful read operation, the IT 1900 deactivates itself.
The second option is activation via the built-in trigger button.
Configuration for the Leuze standard protocol
Scan the adjacent 2D code. The IT 1900 is set to the following transmission parameters: RS 232 transmission with 9,600 baud, 8 data bits, 1 stop bit, no parity, prefix <STX>, terminators <CR><LF>.
IT 1900 - 01 2011/04
Page 5
IT 1900 2D-code hand-held scanner
Connecting the IT 1900 to the serial PC interface
With voltage supply via PIN 9 for RS232 cable (part. no. 50114517)
required parts:
1x IT 1900g XX-2
1x 50114517 KB 232-1 IT190x
With voltage supply via power supply unit with cable RS232 (part no. 50114517)
required parts:
1x IT 1900g XX-2
1x 50114517 KB 232-1 IT190x
1x 50114525 Power supply unit
Notice!
The KB 232-1 IT190x cable (part. no. 50114517) uses TTL level (0 V…5V) for data transmission. Alternatively, the KB 232-2 IT190x cable (part. no. 50115105) can be used which works with the regular RS232 level (-12 V…+12V) and
therefore features a higher interference rejection. Both cables are connection compatible.
Procedure:

1.Switch off the PC.

2.Connect the interface cable to a free COM port (RS 232) on the computer, to the IT 1900 as well as to the power supply unit (if
present).

3.Switch the PC back on.

4.Scan the adjacent barcode.
The IT 1900 is set to the following transmission parame­ters: RS 232 transmission with 115,200 baud, 8 data bits, 1 stop bit, no parity, terminators <CR><LF>.

5.If necessary, adjust the transmission parameters of the used COM port to those of the IT 1900.

Attention!
We recommend connecting the IT 1900 directly to a PC or to the MA 21 or MA 41… connector units. If connecting to other components, please note that the voltage level range is maintained on the data lines!
Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 IT 1900 - 01 info@leuze.de • www.leuze.com
Page 6
Connecting the IT 1900 to the MA 41 DP-K or MA 41 IS
required parts:
1x IT 1900g XX-2
1x 50114517 KB 232-1 IT190x
1x 50114525 Power supply unit
1x 50035421 KB 021 Z
1x 50033638 MA 41 DP-K for Profibus (for Interbus: 50028994 MA 41 IS
or 50030085 MA 41 IS PDP)
Pin assignments KB 021 Z: Core colour: signal terminal in the MA 41: brown (RXD) 2 white (TXD) 1 blue (GND) 4 red (VCC) black (GND) bare (shield) (PE) 21
Procedure:

1.Connect cable KB 021 Z to the MA 41… acc. to the above pin assignments.

2.Connect the interface cable to cable KB 021 Z.

3.Scan the adjacent 2D code.
The IT 1900 is set to the following transmission parameters: RS 232 transmission with 9600 baud, 8 data bits, 1 stop bit, no parity, terminators <CR><LF>.
IT 1900
Connecting the IT 1900 to the MA 21
required parts:
1x IT 1900g XX-2
1x 50114517 KB 232-1 IT190x
1x 50035421 KB 021 Z
1x 50030481 MA 21 100
Pin assignments KB021 Z: Core colour: signal terminal in the MA 21: brown (RXD) 26 white (TXD) 27 blue (GND) 28 red (VCC) 30 black (GND) 31 bare (shield) (PE) 21
Procedure:

1.Connect cable KB 021 Z to the MA 21… acc. to the above pin assignments.

2.Connect the interface cable to cable KB 021 Z.

3.Scan the adjacent 2D code.
The IT 1900 is set to the following transmission parameters: RS 232 transmission with 9600 baud, 7 data bits, 1 stop bit, even parity, terminators <CR><LF>.
IT 1900 - 01 2011/04
Page 7
Disconnect
IT 1900 2D-code hand-held scanner
Connecting the IT 1900 to the MA 2xxi
required parts:
1x IT 1900g XX-2
1x 50114517 KB 232-1 IT190x
1x 50113397 KB JST-HS-300
1x MA 2xxi for the respective fieldbus system
Procedure:

1.Connect the KB JST-HS-300 cable to the system connectors in the MA 2xxi.

2.Connect the interface cable to cable KB JST-HS-300.

3.Scan the adjacent 2D code. The IT 1900 is set to the following transmission parameters:
RS 232 transmission with 9600 baud, 8 data bits, 1 stop bit, no parity, terminators <CR><LF>.
Connecting the IT 1900 to the PS/2 interface
The operation of the IT 1900 in keyboard emulation mode is described in this section. A PC keyboard is emulated in this operating mode. The data which are read in are written directly to the currently activated program. Thus, the data can be processed further in all standard programs.
required parts:
1x IT 1900g XX-2
1x 50114519 KB PS2-1 IT190x
Procedure:

1.Switch off the PC.

2.Disconnect the keyboard.

3.Plug in the IT 1900 hand-held scanner between the
keyboard and the PC.

4.Switch the PC back on.

5.Scan the 2D code shown below.

Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 IT 1900 - 01 info@leuze.de • www.leuze.com
Page 8
IT 1900
Connecting the IT 1900 to the USB interface (keyboard emulation)
The operation of the IT 1900 in keyboard-emulation mode on a USB port is described in this section. A PC keyboard is emulated in this operating mode. The data which are read in are written directly to the currently activated program. Thus, the data can be processed further in all standard programs.
required parts:
1x IT 1900g XX-2
1x 50114521 KB USB-1 IT190x (3m, straight)
or
1x 50114523 KB USB-2 IT190x (5m, spiral)
Procedure:

1.Plug the IT 1900 hand-held scanner into a free USB port.

2.The scanner acknowledges this connection with a beep.

3.Scan the adjacent 2D code.

Connecting the IT 1900 to the USB interface (COM-port emulation)
The operation of the IT 1900 as a serial interface on a USB port is described in this chapter. A COM interface is emulated in this operating mode. The data which are read in are sent to a new COM interface. The driver with which you emulate this COM inter­face can be downloaded from our homepage at www.leuze.de. Thus, the data can be processed further in programs which expect data via COM interfaces.
required parts:
1x IT 1900g XX-2
1x 50114521 KB USB-1 IT190x (3m, straight)
or
1x 50114523 KB USB-2 IT190x (5m, spiral)
Procedure:
1.Install the USB serial driver
(current version at www.leuze.com

2.Plug the IT 1900 hand-held scanner into a free USB port.

3.The scanner acknowledges this connection with a beep.

4.Scan the adjacent 2D code.

5.Open a terminal program or your program for the serial
interface, select the new COM port, and make the following settings: baud rate 38,400, 8 data bits, 1 stop bit, no parity, terminator <CR>.
).
IT 1900 - 01 2011/04
Loading...