operating rooms / switch cabinets with mi nimum protection
class IP54.
The connection, commissioning and replacement of the AS-i
safety monitor requires knowledge of the connecting and
operating instructions as well as of the user manual for the
asimon configuration and diagnostics software (see accessories order guide).
Warning:
Dangerous electrical voltage!
May result in electrical shock and burns.
Before beginnin g work, disconnect the sys tem and device from
voltage.
Depending on the safety components selected for use, the
complete safety system may be clas sified as belonging to a
lower safety category!
Monitoring of safe AS-i slav es (e.g. emergency-shutdown switches)
within an AS-i system as assigned with the ASiMon configuration
software.
Depending on the de vice variant, the second OSS D is available as
safe AS-i output with or without relay.
For full system expan sion i n prot ective op eration , safe shutdow n with
a response time of maximum 40 ms. It is possible here to integrate up
to 31 safe AS-i slaves.
Mixed operation of standard and safe AS-i components is possible.
Multiple AS-i safety monitors can be used within an AS-i s ystem; if
necessary, they can together monitor a safe AS-i slave.
Approved for safe ty applications up to Category 4 a cc. to ISO
13849-1 PLe.
Be certain to maintain the specified safeguards; o nly in this way is
safe shutdown ensured in the case of failure.
Attention!z In addition to the system reaction time of max. 40ms, the reaction
times of the safe AS-interface sen sor slave, of the sensor being
used for monitorin g, of the safe A S-interface actuato r slave and
of the actuator used for this purpose must still be added.
Please note that additional reaction times may likewise arise
through the configuration of the safety monitor.
z The system reaction times of the daisy-chained AS-interface
components are added up when coupling AS-interface networks.
Electrical installation may only be performed by trained specialist
technicians.
Attention!
Each safe AS-interface slave is to be activated at least once per year
and the switching beh aviour of the out put circuits of th e AS-interf ace
safety monitor visually inspected.
After replacing a saf e AS-i slave, the n ew slave mu st be checke d for
proper function; after re placing an AS-i safety monitor , the new AS-i
safety monitor must be checked for proper function.
Supply lines, signal lines and the AS-i bus line are to be laid
separately from power supply lines.
Suitable spark extinction must be used with conta ctors in the switch
cabinet.
For drive motors and brakes, observe the instal lation notices in the
correspon ding operating instructions.
Maximum line leng th for the AS-i bus line is 10 0 m. For longer l ine
lengths, use AS-i repeaters.
Attention!
The AS-interface power supply unit for supplying the AS-interface
components must demonstrate safe mains separation acc. to
IEC 60742 a nd the ability to bridge brief main s fai lur es of up to 2 0ms.
The power supply unit for 24 V supply must also demonstrate safe
mains separation acc. to IEC 60742 and the ability to bridge brief
mains failures of up to 20ms.
off–
yellow, continuousstart-up/restart-disable active
yellow, flashingexternal test necessary / acknowledge-
offcontacts of the output switching element
green, continuouscontacts of the output switching element
green, flashingdelay time runs in event of Stop Category 1
offcontacts of the output switching element
red, continuouscontacts of the output switching element
red, flashingerror on level of the monitored AS-interface
simultaneously
flashing rapidly
ment / delay before start-up active
open
closed
closed
open
components
internal device error,
error message can be queried by means of
asimon software
580032ASM-SWCASM commissio ning set for ASM1, ASM1E and
50104078ASM1-PK ASM1 configuration cable
50104079ASM1-DK ASM1 device-replacement data cable
ASM2E
Contains: asimon configuration and diagno stics
software, connecting and operating instructions,
user manual for the software on CD, configuration
cable, device-replacem en t data cabl e