Operating voltage U
Power consumptionmax. 8W @ 9 VDC
B
3.7V DC internal battery9V DC
Li-ion battery
Capacity2.000mAh
Max. number of scans57.000
Max. operating time16h at 1 scan/s
Charging time at 9V DC4h for complete charge following complete discharge
RF data transmission
Frequency2.4 … 2.4835GHz (ISM band)
Typ. Range10m
Transmission speed720kBit/s
Frequency hopping, Bluetooth ® V1.2, Class 2
Interfaces
Interface typeTTL-RS 232, PS/2 and USB
Triggervia button or serial command
Optical system3648 linear imager
Contrast20% (black/white)
Light sourceintegrated diffuse LED 630nm
Read distance25 … 610mm (UPC 100%)
Read angleomnidirectional, various tilt and rotational angles up to 65°
Mechanical dataIT 3820IT 3820iST 2020
HousingUL94V0 grade
Weight261 g72g250g (without cable)
Dimensions157x 135 x81 mm157x 135 x81 mm79x 142 x109 mm
Shock resistance50 falls from a height
of 1.8m
50 falls from a height
of 2m
50 falls from a height
of 1m
Environmental data
Ambient temp. (operation)0°C … +50 °C-10°C … +50 °C0 °C … +50 °C
Ambient temp. (storage)-40°C … +60°C-40°C … +70°C-40°C … +60°C
Relative air humidity0 … 95%
Light sourceexempt group (in acc. with EN 62471)
Protection classIP41IP54IP41
CertificationsIEC 60950-1 (US-19800-UL)
Hand-held scanner for barcodes (standard range)Part No.
IT 3820 SR 0C0BEIT 3820 SR with RS 232/USB/PS/2 interface501 06242
IT 3820i SR E IT 3820i SR with RS 232/USB/PS/2 interface501 10471
Tables
Diagrams
Remarks
Operate in accordance with
intended use!
The product may only be put into
operation by competent persons.
Only use the product in accor-
dance with the intended use.
Ergonomically shaped handheld scanner with integrated
decoder for barcodes
Data transmission via configurable RS 232 interface.
Or keyboard-wedge operation via PS/2 or USB interface.
For a functional unit, an
IT 3820 hand-held scanner
and a ST 2020 base station
as well as a power supply
unit and corresponding cable
must be ordered.
Base station for Bluetooth transmissionPart No.
ST 2020-5BE ST 2020 with RS 232/USB/PS/2 interface
501 10663
(without cable)
IT 3820/3820i - 062014/07
Bluetooth is a trademark owned by
Bluetooth SIG, Inc., U.S.A. and
licensed to Hand-Held Products
Page 3
Connection for power sup-
ply unit
Connection for interface ca-
ble
IT 3820/3820iHand-held barcode scanner with Bluetooth data transmission
Switching off the computer
Information on switching off and shutting down the connected computer - which must always be performed before connecting
peripheral devices, such as a scanner - can be found in the appropriate operating instructions for your computer.
Connecting the IT 3820
Shown in the figure to the right are the locations for installing the cable on
the base station. The individual installation steps are described in the following.
1.To secure the interface cable to the scanner, proceed as follows:
plug the RJ 41 connector into the socket on the bottom of the base station until the cable clicks into place.
2.Connect the interface cable to the appropriate connection socket on
the computer.
3.You may need a power supply unit for voltage supply if you would like
to charge the hand-held scanner at the base station or if you use an
RS 232 interface. Use the pin assignments (see "Electrical connection"
on page 1) to select the appropriate cable for your application.
4.Connect the power supply unit to the power socket.
5.Use the code for the respective application to configure the hand-held
scanner, see chapter "Configuration".
6.Check the operational readiness of the scanner by pointing the scanning surface towards a flat surface and pulling the trigger. A green
target line as well as the red illumination should now be visible. Now scan a sample label.
The scanner emits an audible signal to confirm that the label has been read; if necessary, the data are now passed on to the
computer.
Configuration
The hand-held scanner can always be configured using bar codes. To do this, the barcode must first be selected on the package
insert and then the trigger actuated in order to read the code. The configuration is then immediately accepted and executed.
Several of the most important configurations are listed in the following.
A second option is to configure the hand-held scanner with the USB and RS 232 interfaces with the aid of the VisualMenu PC
program. You can download and install this program from our homepage at www.leuze.de
The program can be used to make settings and transfer them to the hand-held scanner. The configuration can also be stored so
that it can be reused at a later time.
The standard applications are described and summarised below.
Notice!
Additional information on the device and short instructions can be found on the Internet at www.leuze.de.
.
Resetting the IT 3820 to factory settings
To reset all parameters to factory settings, scan the adjacent
barcode.
Attention!
All settings are lost!!!
Return the IT 3820 to the base station to apply the settings. This procedure is concluded with audible confirmation signals.
You may then continue making settings or operation of the device.
To activate the read process, a trigger signal is to be sent via the serial RS 232 interface or USB interface (COM port emulation
only). The command is to be sent at the set baud rate, parity, and data and stop bits.
The command for activation is: SYN T CRASCII decimal values: 022; 084; 013
To cancel read readiness, send a deactivation.
The command for deactivation is: SYN U CRASCII decimal values: 022; 085; 013
Following a successful read operation, the IT 3820 deactivates itself.
The second option is activation via the built-in trigger button.
Configuration for the Leuze standard protocol
To set the Leuze standard protocol, you must first reset the scanner to factory settings and then individually define each of the
transmission parameters using a barcode
Procedure:
1.Scan the adjacent barcode.
The IT 3820 is reset to factory settings.
2.Return the IT 3820 to the base station to apply the settings.
This procedure is concluded with audible confirmation signals.
3.Successively scan the 4 barcodes shown below. Each read operation is confirmed by a beep.
The IT 3820 is set to the following transmission parameters: RS 232 transmission with 9,600 baud, 8 data bits, 1 stop bit, no parity, prefix <STX>, terminators <CR><LF>.
9600 Bd
Terminal ID
Prefix STX
Postfix CR/LF
IT 3820/3820i - 062014/07
Page 5
IT 3820/3820iHand-held barcode scanner with Bluetooth data transmission
Connecting the IT 3820 to the serial PC interface
With TTL-RS232 cable/PIN9 IT 4xxx Part No. 501 04586
required parts:
1x 501 06 242IT 3820 SR 0C0BE
1x 501 03 990Base station ST 2020
1x 501 04 586Cable TTL-RS232/PIN9
1x 501 03 989Power supply unit ST 2020
Procedure:
1.Switch off the PC.
2.Connect the interface cable to a free COM port
(RS 232) on the computer (3) and to the base station
(2).
3.Plug one end of the power supply unit cable into the
base station (4) and the other end into a free power
socket (5).
4.Switch the PC back on.
5.Scan the adjacent barcode.
The IT 3820 is set to the following transmission parameters:
RS 232 transmission with 115,200 baud, 8 data bits, 1 stop bit, no parity, terminators <CR><LF>.
6.Return the IT 3820 to the base station to apply the settings. This procedure is concluded with optical confirmation signals
(green LED on the ST 2020).
7.If necessary, adjust the transmission parameters of the used COM port to those of the IT 3820.
Attention!
We recommend connecting the IT 3820 directly to a PC or to the MA 21 or MA 41… connector units. If connecting to
other components, please note that a voltage level range of -14 … +14V is maintained on the data lines!
Connecting the IT 3820 to the MA 41 DP-K or MA 41 IS
required parts:
1x 501 06 242IT 3820 SR 0C0BE
1x 501 03 990Base station ST 2020
1x 501 04 586Cable TTL-RS232/PIN9
1x 501 03 989Power supply unit ST 2020
1x 500 35 421KB 021 Z
1x 500 33 638MA 41 DP-K for Profibus (for Interbus:500 28 994 MA 41 IS
or500 30 085 MA 41 IS PDP)
Pin assignments KB 021 Z:
Core colour:signalterminal in the MA 41:
brown(RXD)2
white(TXD)1
blue(GND)4
red(VCC)
black(GND)
bare (shield)(PE)21
Procedure:
1.Connect cable KB 021 Z to the MA 41… acc. to the above pin assignments.
2.Connect the interface cable to cable KB 021 Z. Connect the
interface cable and the power supply unit to the base station
(see "Connecting the IT 3820 to the serial PC interface").
3.Scan the adjacent barcode.
The IT 3820 is reset to factory settings.
4.Return the IT 3820 to the base station to apply the settings.
This procedure is concluded with audible confirmation signals.
5.Successively scan the 3 barcodes shown below. Each read operation is confirmed by a beep.
The IT 3820 is set to the following transmission parameters: RS 232 transmission with 9,600 baud, 8 data bits, 1 stop bit, no parity, terminators <CR><LF>.
9600 Bd
Terminal ID
Postfix CR/LF
IT 3820/3820i - 062014/07
Page 7
IT 3820/3820iHand-held barcode scanner with Bluetooth data transmission
Connecting the IT 3820 to the MA 21
required parts:
1x 501 06 242IT 3820 SR 0C0BE
1x 501 03 990Base station ST 2020
1x 501 04 586Cable TTL-RS232/PIN9
1x 501 03 989Power supply unit ST 2020
1x 500 35 421KB 021 Z
1x 500 30 481MA 21 100
Pin assignments KB021 Z:
Core colour:signalterminal in the MA 21:
brown(RXD)26
white(TXD)27
blue(GND)28
red(VCC)
black(GND)
bare (shield)(PE)21
Procedure:
1.Connect cable KB 021 Z to the MA 21… acc. to the above pin assignments.
2.Connect the interface cable to cable KB 021 Z. Connect the
interface cable and the power supply unit to the base station
(see "Connecting the IT 3820 to the serial PC interface").
3.Scan the adjacent barcode.
The IT 3820 is reset to factory settings.
4.Return the IT 3820 to the base station to apply the settings.
This procedure is concluded with audible confirmation signals.
5.Successively scan the 4 barcodes shown below. Each read operation is confirmed by a beep.
The IT 3820 is set to the following transmission parameters: RS 232 transmission with 9,600 baud, 7 data bits, 1 stop bit, even
parity, terminators <CR><LF>.
The operation of the IT 3820 in keyboard emulation mode is described in this section. A PC keyboard is emulated in this operating
mode. The data which are read in are written directly to the currently activated program. Thus, the data can be processed further
in all standard programs.
required parts:
1x 501 06 242IT 3820 SR 0C0BE
1x 501 03 990Base station ST 2020
1x 501 03 989Power supply unit ST 2020
1x 501 03 409 PS/2 cable
Procedure:
1.Switch off the PC.
2.Disconnect the keyboard.
3.Connect the cable for the ST 2020 base sta-
tion between the keyboard and the PC.
4.Switch the PC back on.
5.Scan the barcodes shown below.
6.Return the IT 3820 to the base station to apply
the settings. This procedure is concluded with
audible confirmation signals.
IBM PCs and compatible PCs, postfix
Keyboard layout for Germany/Austria
Notice!
To charge the IT 3820, the power supply unit must be plugged in and the hand-held scanner placed in the ST 2020
base station.
IT 3820/3820i - 062014/07
Page 9
IT 3820/3820iHand-held barcode scanner with Bluetooth data transmission
Connecting the IT 3820 to the USB interface (keyboard emulation)
The operation of the IT 3820 in keyboard-emulation mode on a USB port is described in this section. A PC keyboard is emulated
in this operating mode. The data which are read in are written directly to the currently activated program. Thus, the data can be
processed further in all standard programs.
required parts:
1x 501 06 242IT 3820 SR 0C0BE
1x 501 03 990Base station ST 2020
1x 501 03 989Power supply unit ST 2020
1x 501 03 404 USB cable
Procedure:
1.Connect the cable for the ST 2020 base station to a free
USB port.
2.The scanner acknowledges this connection with a beep.
3.Scan the barcodes shown below.
USB keyboard emulation with CR LF
Keyboard layout for Germany/Austria
Notice!
To charge the IT 3820, the power supply unit must be plugged in and the hand-held scanner placed in the ST 2020
base station.
Connecting the IT 3820 to the USB interface (COM-port emulation)
The operation of the IT 3820 as a serial interface on a USB port is described in this chapter. A COM interface is emulated in this
operating mode. The data which are read in are sent to a new COM interface. The driver with which you emulate this COM interface can be downloaded from our homepage at www.leuze.de
data via COM interfaces.
required parts:
1x 501 06 242IT 3820 SR 0C0BE
1x 501 03 990Base station ST 2020
1x 501 03 989Power supply unit ST 2020
1x 501 03 404 USB cable
Procedure:
1.Connect the cable for the ST 2020 base station to a free
USB port.
2.The scanner acknowledges this connection with a beep.
3.Scan the barcodes shown below.
4.Install the USB serial driver when you are prompted to
do so by Windows.
5.Open a terminal program or your program for the serial
interface, select the new COM port, and make the following settings: baud rate 38,400, 8 data bits, 1 stop bit,
no parity, terminator <CR>.
. Thus, the data can be processed further in programs which expect
USB COM-port emulation
Add CR Suffix
Notice!
To charge the IT 3820, the power supply unit must be plugged in and the hand-held scanner placed in the ST 2020
base station.
IT 3820/3820i - 062014/07
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.