Leuze IT 3800g User Manual

Page 1
Leuze electronic
Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 www.leuze.de
We reserve the right to make changes • BP_IT3800g_gb.fm
z Hand-held scanner for barcodes z Large reading field for the detection of
codes
4,5 - 12 V
DC
Accessories
z TTL-RS 232-cable/ext for IT 4xxx
Part No. 501 04442
z TTL-RS 232-cable/PIN 9 for IT 4xxx
Part No. 501 04586
z PS/2-cable for IT 4xxx Part No. 501 03409 z USB-cable for IT 4xxx Part No. 501 03404 z Power supply unit for IT 4xxx
Part No. 501 03403
z Support for IT 3800g Part No. 501 07039
Dimensioned drawing
Electrical connection
for RS 232 cable / ext.
for RS 232 cable / PIN 9
for USB cable
for PS/2 cable
9-pin Sub-D Signal
Connection for power
supply unit
IT 3800g RJ41
SH Shield SH 2
2TXD 6 3RXD 5 5GND 1 4 7CTS 9 8RTS 8
5VDC 2 7
9-pin Sub-D Signal IT 3800g RJ41
SH Shield 2
2TXD6 3RXD5 5GND4 7CTS9 8RTS8 95VDC7
USB type A Signal IT 3800g RJ41
15VDC7+3 2 Data - 10 3Data +2 4GND4
Mini DIN connector Mini DIN socket Signal IT 3800g RJ41
1 - PC Data 6 22NC 33GND4 445VDC7 5 - PC Clock 5 66NC
- 1 KB Data 8
-5KB Clock9
IT 3800g Hand-held barcode scanner
IT 3800g - 02
Part No. 501 07087
Page 2
Leuze electronic
IT 3800g - 02 0705
Specifications
Reading field
Electrical data
Operating voltage U
B
4.5 … 12VDC
Power consumption max. 1.8W
Interfaces
Interface type TTL-RS 232, PS/2 and USB Trigger via button
Code types
Bar codes 2/5 Interleaved, Code 39, Code 128, Code 93, Codabar,
UPC/EAN, RSS, Codablock
Optical data
Optical system 3648 linear Imager Contrast 20% (black/white) Light source integrated diffuse LED 630nm Read distance 13 … 460mm (UPC 100%) Read angle various tilt and rotational angles up to 65°
Mechanical data
Housing UL94V0 grade Weight 159g (without cable) Dimensions 150x 112 x 79 mm Shock resistance 50 falls from a height of 1.5m
Environmental data
Ambient temp. (operation) -0°C … +50°C Ambient temp. (storage) -40°C … +60°C Relative air humidity 0 … 95% (non-condensing) Protection class IP 41
IT 3800g Module or cell from to
Bar codes 5mil / 0.127mm 50mm 200mm
7.5mil / 0.19mm 40 mm 300 mm 10mil / 0.25mm 30mm 380 mm 13mil / 0.33mm 10mm 460 mm 15mil / 0.38mm 30mm 560 mm 20mil / 0.5mm 30mm 660 mm
Order guide
Hand-held scanner for barcodes (standard range) Part No.
IT 3800g 15E IT 3800g with TTL-RS 232, KBW and USB interface 501 07041
Tables
Diagrams
Remarks
Ergonomically shaped hand­held scanner with integrated decoder for barcodes.
Data transmission via config­urable RS 232 interface.
Or keyboard-wedge opera­tion via PS/2 or USB inter­face.
IT 3800g
Page 3
Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 IT 3800g - 02 www.leuze.de
Leuze electronic
Switching off the computer
Information on switching off and shutting down the connected computer - which must always be performed before connecting peripheral devices, such as a scanner - can be found in the appropriate operating instructions for your computer.
Connecting the IT 3800
Shown in the adjacent figure are the individual steps for installing the cable on the scanner; these steps are described in the following.
1.To secure the interface cable to the scanner, proceed as follows: plug the RJ 41 connector into the socket on the bottom of the hand-held scanner.
2.Connect the interface cable to the appropriate connection socket on the computer.
3.You may need a power supply unit for supplying voltage; alternatively, you can use a cable which supplies voltage from the computer system. Use the pin assignments (see "Electrical connection" on page 1) to select the appropriate cable for your application.
4.Connect the power supply unit to the power socket (not necessary if volt­age is supplied from the computer).
5.Use the code for the respective application to configure the hand-held scanner, see chapter "Configuration".
6.Check the operational readiness of the scanner by pointing the scanning surface towards a flat surface and pulling the trigger. A red target line should now be visible. Now scan a sample label. The scanner emits an audible signal to confirm that the label has been read; if necessary, the data are now passed on to the computer.
Configuration
The hand-held scanner can always be configured using bar codes. To do this, the barcode must first be selected on the package insert and then the trigger actuated in order to read the code. The configuration is then immediately accepted and executed.
Several of the most important configurations are listed in the following.
A second option is to configure the hand-held scanner with the USB and RS 232 interfaces with the aid of the VisualMenu PC program. You can download and install this program from our homepage at
www.leuze.de
. The program can be used to make settings and transfer them to the hand-held scanner. The configuration can also be stored so that it can be reused at a later time.
Further information on this can be found in the User's Guide for the IT 3800g.
The standard applications are described and summarised below.
Notice!
Additional information on the device and short instructions can be found on the Internet at www.leuze.de.
Resetting the IT 3800g to factory settings
To reset all parameters to factory settings, scan the adjacent barcode.
Attention!
All settings are lost!!!
You may then continue making settings or operation of the device.
Cable latch
IT 3800g Hand-held barcode scanner
Page 4
IT 3800g - 02 0705
Leuze electronic
Trigge r
To activate the read process, a trigger signal is to be sent via the serial RS 232 interface or USB interface (COM port emulation only). The command is to be sent at the set baud rate, parity, and data and stop bits.
The command for activation is: SYN T CR ASCII decimal values: 022; 084; 013
To cancel read readiness, send a deactivation.
The command for deactivation is: SYN U CR ASCII decimal values: 022; 085; 013
Following a successful read operation, the IT 3800g deactivates itself.
The second option is activation via the built-in trigger button.
Configuration for the Leuze standard protocol
To set the Leuze standard protocol, you must first reset the scanner to factory settings and then individually define each of the transmission parameters using a barcode
Procedure:
1.Scan the adjacent barcode.
The IT 3800g is reset to factory settings.
2.Successively scan the 4 barcodes shown below. Each read
operation is confirmed by a beep.
The IT 3800g is set to the following transmission parameters: RS 232 transmission with 9,600 baud, 8 data bits, 1 stop bit, no parity, prefix <STX>, terminators <CR><LF>.
9600 Bd
Ter m i na l I D
Prefix STX
Postfix CR/LF
IT 3800g
Page 5
Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 IT 3800g - 02 www.leuze.de
Leuze electronic
Connecting the IT 3800g to the serial PC interface
With voltage supply via PIN 9 with TTL-RS232-cable/PIN9 IT 4xxx Part No. 501 04586
required parts:
1x 501 07 041 IT 3800g 15E
1x 501 04 586 Cable TTL-RS232/PIN9
With voltage supply via power supply unit with cable RS232/ext IT 4xxx Part No. 501 04442
required parts:
1x 501 07 041 IT 3800g 15E
1x 501 04 442 Cable TTL-RS232/ext
1x 501 03 403 Power supply unit
Procedure:
1.Switch off the PC.
2.Connect the interface cable to a free COM port
(RS 232) on the computer, to the IT 3800g as well as to the power supply unit.
3.Switch the PC back on.
4.Scan the adjacent barcode.
The IT 3800g is set to the following transmission parameters: RS 232 transmission with 38,400 baud, 8 data bits, 1 stop bit, no parity, terminators <CR><LF>.
5.If necessary, adjust the transmission parameters of the used COM port to those of the IT 3800g.
Attention!
We recommend connecting the IT 3800g directly to a PC or to the MA 21 or MA 41… connector units. If connecting to other components, please note that a voltage level range of -12 … +12V is maintained on the data lines!
IT 3800g Hand-held barcode scanner
Page 6
IT 3800g - 02 0705
Leuze electronic
Connecting the IT 3800g to the MA 41 DP-K or MA 41 IS
required parts:
1x 501 07 041 IT 3800g 15E
1x 501 04 442 Cable TTL-RS232/ext
1x 501 03 403 Power supply unit
1x 500 35 421 KB 021 Z
1x 500 33 638 MA 41 DP-K for Profibus (for Interbus: 500 28 994 MA 41 IS
or 500 30 085 MA 41 IS PDP)
Pin assignments KB 021 Z: Core colour: signal terminal in the MA 41: brown (RXD) 2 white (TXD) 1 blue (GND) 4 red (VCC) black (GND) bare (shield) (PE) 21
Procedure:
1.Connect cable KB 021 Z to the MA 41… acc. to the above pin
assignments.
2.Connect the interface cable to cable KB 021 Z.
3.Scan the adjacent barcode.
The IT 3800g is reset to factory settings.
4.Successively scan the 3 barcodes shown below. Each read operation is confirmed by a beep.
The IT 3800g is set to the following transmission parameters: RS 232 transmission with 9,600 baud, 8 data bits, 1 stop bit, no parity, terminators <CR><LF>.
9600 Bd
Ter m i na l I D
Postfix CR/LF
IT 3800g
Page 7
Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 IT 3800g - 02 www.leuze.de
Leuze electronic
Connecting the IT 3800g to the MA 21
required parts:
1x 501 07 041 IT 3800g 15E
1x 501 04 586 Cable TTL-RS232/PIN9
1x 500 35 421 KB 021 Z
1x 500 30 481 MA 21 100
Pin assignments KB021 Z: Core colour: signal terminal in the MA 21: brown (RXD) 26 white (TXD) 27 blue (GND) 28 red (VCC) 30 black (GND) 31 bare (shield) (PE) 21
Procedure:
1.Connect cable KB 021 Z to the MA 21… acc. to the above pin
assignments.
2.Connect the interface cable to cable KB 021 Z.
3.Scan the adjacent barcode.
The IT 3800g is reset to factory settings.
4.Successively scan the 4 barcodes shown below. Each read operation is confirmed by a beep.
The IT 3800g is set to the following transmission parameters: RS 232 transmission with 9,600 baud, 7 data bits, 1 stop bit, even parity, terminators <CR><LF>.
9600 Bd
Ter m i na l I D
7 data bits, even parity, 1 stop bit
Postfix CR/LF
IT 3800g Hand-held barcode scanner
Page 8
IT 3800g - 02 0705
Leuze electronic
Connecting the IT 3800g to the PS/2 interface
The operation of the IT 3800g in keyboard emulation mode is described in this section. A PC keyboard is emulated in this operating mode. The data which are read in are written directly to the currently activated program. Thus, the data can be processed further in all standard programs.
required parts:
1x 501 07 041 IT 3800g 15E
1x 501 03 409 PS/2 cable
Procedure:
1.Switch off the PC.
2.Disconnect the keyboard.
3.Plug in the IT 3800g hand-held scanner
between the keyboard and the PC.
4.Switch the PC back on.
5.Scan the barcodes shown below.
IBM PCs and compatible PCs, postfix
Keyboard layout for Germany/Austria
Disconnect
IT 3800g
Page 9
Leuze electronic GmbH + Co. KG Post-box 1111 D-73277 Owen-Teck Tel. +49 7021 5730 IT 3800g - 02 www.leuze.de
Leuze electronic
Connecting the IT 3800g to the USB interface (keyboard emulation)
The operation of the IT 3800g in keyboard-emulation mode on a USB port is described in this section. A PC keyboard is emulated in this operating mode. The data which are read in are written directly to the currently activated program. Thus, the data can be processed further in all standard programs.
required parts:
1x 501 07 041 IT 3800g 15E
1x 501 03 404 USB cable
Procedure:
1.Plug the IT 3800g hand-held scanner into a free USB
port.
2.The scanner acknowledges this connection with a beep.
3.Scan the barcodes shown below.
USB keyboard emulation with CR LF
Keyboard layout for Germany/Austria
IT 3800g Hand-held barcode scanner
Page 10
IT 3800g - 02 0705
Leuze electronic
Connecting the IT 3800g to the USB interface (COM-port emulation)
The operation of the IT 3800g as a serial interface on a USB port is described in this chapter. A COM interface is emulated in this operating mode. The data which are read in are sent to a new COM interface. The driver with which you emulate this COM interface can be downloaded from our homepage at
www.leuze.de
. Thus, the data can be processed further in programs which expect data
via COM interfaces.
required parts:
1x 501 07 041 IT 3800g 15E
1x 501 03 404 USB cable
Procedure:
1.Plug the IT 3800g hand-held scanner into a free USB
port.
2.The scanner acknowledges this connection with a beep.
3.Scan the barcode shown below.
4.Install the USB serial driver when you are prompted to do
so by Windows.
5.Open a terminal program or your program for the serial
interface, select the new COM port, and make the follow­ing settings: baud rate 38,400, 8 data bits, 1 stop bit, no parity, terminator <CR>.
USB COM-port emulation
IT 3800g
Loading...