2D-code hand-held scanner (Extended Range optics with large operating range)Part no.
IT 1910i ER-3with RS 232, PS/2 and USB interface50122436
2D-code hand-held scanner (Full Range optics with very large operating range)Part no.
IT 1980i FR-3with RS 232, PS/2 and USB interface50130497
IT 1910i / IT 1980i - 032015/09
Remarks
Operate in accordance
with intended use!
The product may only be put into
operation by competent persons.
Only use the product in accor-
dance with the intended use.
Hand-held scanner with integrated decoder for high-contrast codes suitable for
industrial use.
Data transmission via configurable RS 232 interface.
Or keyboard-wedge operation via PS/2 or USB interface.
A Laser aperture
B Laser warning sign
C Laser information sign with laser parameters
ACA
B
IT 1910i / IT 1980i2D-code hand-held scanner suitable for industrial use
Laser safety notices
ATTENTION, LASER RADIATION – LASER CLASS 2
Never look directly into the beam!
The device fulfills the EN 60825-1:2007 safety regulations for a product in laser class 2 as well as the U.S. 21 CFR 1040.10 regulations
with deviations corresponding to "Laser Notice No. 50" from June 24th, 2007.
Never look directly into the laser beam or in the direction of reflecting laser beams!
If you look into the beam path over a longer time period, there is a risk of injury to the retina.
Do not point the laser beam of the device at persons!
Interrupt the laser beam using a non-transparent, non-reflective object if the laser beam is accidentally directed towards a person.
When mounting and aligning the device, avoid reflections of the laser beam off reflective surfaces!
CAUTION! Use of controls or adjustments or performance of procedures other than specified herein may result in hazardous light
exposure.
Observe the applicable statutory and local laser protection regulations.
The device must not be tampered with and must not be changed in any way.
There are no user-serviceable parts inside the device.
Repairs must only be performed by Leuze electronic GmbH + Co. KG.
NOTICE
Laser information and warning signs firmly attached to the device.
IT 1910i / IT 1980i - 03
IT 1910i / IT 1980i
Switching off the computer
Information on switching off and shutting down the connected computer - which must always be performed before connecting
peripheral devices, such as a scanner - can be found in the appropriate operating instructions for your computer.
Connecting the IT 1910i / IT 1980i
The adjacent figure shows the position of the cable connection on the scanner. The
individual steps for installing the cable on the scanner are described in the following.
1.To secure the interface cable to the scanner, proceed as follows:
Loosen the Phillips screw on the cable interlock on the bottom of the hand-held
scanner and, to open, push the cable interlock in the direction of the arrow to the
end position (). Insert the RJ 41 connector into the socket on the bottom of the
hand-held scanner until the connector engages.
2.To close, push the cable interlock back and secure the cable interlock by tightening
the Phillips screw ().
3.Connect the interface cable to the appropriate connection socket on the computer.
4.You may need a power supply unit for supplying voltage; alternatively, you can use
a cable which supplies voltage from the computer system. Use the pin assignments
(see "Electrical connection" on page 1) to select the appropriate cable for your
application.
5.Connect the power supply unit to the power socket (not necessary if voltage is supplied from the computer).
6.Check the operational readiness of the scanner by pointing the scanning surface
towards a flat surface and pulling the trigger. A red target pattern as well as the red
illumination should now be visible. Now scan a sample label.
The scanner emits an audible signal to confirm that the label has been read; if necessary, the data are now passed on to the computer.
Parameterization
The hand-held scanner can always be configured using bar codes. To do this, the bar code must first be selected on the package
insert and then the trigger actuated in order to read the code. The configuration is then immediately accepted and executed.
Several of the most important configurations are listed in the following.
A second option is to configure the hand-held scanner with the USB and RS 232 interfaces with the aid of the EZ Config PC
program. You can download and install this program from our homepage at www.leuze.com
The program can be used to make settings and transfer them to the hand-held scanner. The configuration can also be stored so
that it can be reused at a later time.
More information can also be found in the user's guide.
The standard applications are described and summarized below.
Notice!
Additional information on the device and short instructions can be found on the Internet at www.leuze.com.
.
IT 1910i / IT 1980i - 032015/09
IT 1910i / IT 1980i2D-code hand-held scanner suitable for industrial use
Resetting the IT 1910i / IT 1980i to factory settings
To reset all parameters to factory settings, scan the adjacent
bar code.
Attention!
All settings are lost!!!
Trigger
To activate the read process, a trigger signal is to be sent via the serial RS 232 interface or USB interface (COM port emulation
only). The command is to be sent at the set baud rate, parity, and data and stop bits.
The command for activation is: SYN T CR ASCII decimal values: 022; 084; 013
To cancel read readiness, send a deactivation.
The command for deactivation is: SYN U CRASCII decimal values: 022; 085; 013
Following a successful read operation, the hand-held scanner deactivates itself.
The second option is activation via the built-in trigger button.
Configuration for the Leuze standard protocol
Scan the adjacent 2D-code. The hand-held scanner is set to the following transmission parameters:
RS 232 transmission with 9,600 baud, 8 data bits, 1 stop bit, no parity,
prefix <STX>, postfixes <CR><LF>.
IT 1910i / IT 1980i - 03
IT 1910i / IT 1980i
Connecting the IT 1910i / IT 1980i to the serial PC interface
Voltage supply via power supply unit with RS232 cable (part no. 50114517)
Required parts:
1xIT 1910i ER-3 or IT 1980i FR-3
1x 50114517 KB 232-1 IT190x
1x 50114525Power supply unit
Notice!
Cable KB 232-1 IT190x (part no. 50114517) uses TTL-level
(0V…5V) for data transmission. As an alternative to this,
cable KB 232-2 IT190x (part no. 50115105) can be used.
This cable works with the regular RS232 level (-12V…+12V)
and therefore features a higher interference rejection. Both
cables are connection compatible.
Procedure:
1.Switch off the PC.
2.Connect the interface cable to a free COM port (RS 232) on the computer, to the hand-held scanner as well as to the power
supply unit (if present).
3.Switch the PC back on.
4.Scan the adjacent bar code. The hand-held scanner is
set to the following transmission parameters:
RS 232 transmission with 115,200 baud, 8 data bits, 1
stop bit, no parity, postfixes <CR><LF>.
5.If necessary, adjust the transmission parameters of the
used COM port to those of the hand-held scanner.
Attention!
We recommend connecting the hand-held scanner directly to a PC or to the MA 21 or MA 41… connection units. If
connecting to other components, please note that a voltage level range is maintained on the data lines!
IT 1910i / IT 1980i - 032015/09
IT 1910i / IT 1980i2D-code hand-held scanner suitable for industrial use
Connecting the IT 1910i / IT 1980i to the MA 21
Required parts:
1xIT 1910i ER-3 or IT 1980i FR-3
1x 50114517 KB 232-1 IT190x
1x 50035421KB 021 Z
1x 50030481MA 21 100
Pin assignments KB021 Z:
Core color:SignalTerminal in the MA 21:
Brown(RXD)26
White(TXD)27
Blue(GND)28
Red(VCC)30
Black(GND)31
Bare (shield)(PE)21
Procedure:
1.Connect cable KB 021 Z to the MA 21… acc. to the above pin assignments.
2.Connect the interface cable to cable KB 021 Z.
3.Scan the adjacent 2D code.
The hand-held scanner is set to the following transmission parameters:
RS 232 transmission with 9,600 baud, 7 data bits, 1 stop bit, even parity, postfixes
<CR><LF>.
Connecting the IT 1910i / IT 1980i to the MA 2xxi
Required parts:
1xIT 1910i ER-3 or IT 1980i FR-3
1x 50114517 KB 232-1 IT190x
1x 50113397KB JST-HS-300
1xMA 2xxi for the respective fieldbus system
Procedure:
1.Connect cable KB JST-HS-300 to the system connector on the MA 2xxi.
2.Connect the interface cable to cable KB JST-HS-300.
3.Scan the adjacent 2D code.
The hand-held scanner is set to the following transmission parameters:
RS 232 transmission with 9,600 baud, 8 data bits, 1 stop bit, no parity, postfixes
<CR><LF>.
IT 1910i / IT 1980i - 03
Disconnect
IT 1910i / IT 1980i
Connecting the IT 1910i / IT 1980i to the PS/2 interface
The operation of the hand-held scanner in keyboard emulation mode is described in this section. With this operating mode, a PC
keyboard is emulated. The read data are written directly into the currently activated program. The data can thereby be further
processed in all standard programs.
Required parts:
1x IT 1910i ER-3 or IT 1980i FR-3
1x 50114519KB PS2-1 IT190x
Procedure:
1.Switch off the PC.
2.Disconnect the keyboard.
3.Plug in the hand-held scanner between the keyboard
and the PC.
4.Switch the PC back on.
5.Scan the 2D code shown below.
IT 1910i / IT 1980i - 032015/09
IT 1910i / IT 1980i2D-code hand-held scanner suitable for industrial use
Connecting the IT 1910i / IT 1980i to the USB interface (keyboard emulation)
Operating the hand-held scanner in keyboard emulation mode on a USB port is described in this section. With this operating
mode, a PC keyboard is emulated. The read data is written directly into the currently activated program. The data can therefore
be further processed in all standard programs.
Required parts:
1xIT 1910i ER-3 or IT 1980i FR-3
1x 50114521 KB USB-1 IT190x (3 m, straight)
or
1x 50114523 KB USB-2 IT190x (5 m, spiral)
Procedure:
1.Plug the hand-held scanner into a free USB port.
2.The scanner acknowledges this connection with a
beep.
3.Scan the adjacent 2D code.
Connecting the IT 1910i / IT 1980i to the USB interface (COM port emulation)
The operation of the hand-held scanner as a serial interface on a USB port is described in this chapter. With this operating mode,
a COM interface is emulated. The read data are sent to a new COM interface. The drivers with which this COM interface is emulated can be downloaded from our homepage at www.leuze.com
expect data via COM interfaces.
Required parts:
1xIT 1910i ER-3 or IT 1980i FR-3
1x 50114521 KB USB-1 IT190x (3 m, straight)
or
1x 50114523 KB USB-2 IT190x (5 m, spiral)
Procedure:
1.Install the USB serial driver
(current version available at www.leuze.com)
2.Plug the hand-held scanner into a free USB port.
3.The scanner acknowledges this connection with a
beep.
4.Scan the adjacent 2D code.
5.Open a terminal program or your program for the
serial interface, select the new COM port, and
make the following settings: baud rate 115,200, 8
data bits, 1 stop bit, no parity, postfix <CR>.
.
. Thus, the data can be processed further in programs which
IT 1910i / IT 1980i - 03
IT 1910i / IT 1980i
IT 1910i / IT 1980i - 032015/09
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.