Leuze ACR 300i Installation guide

TECHNICAL DATA
ACR 300i
Electrical data
ACR300i Installation guide
Operating voltage U Residual ripple < 5 Vss Current consumption (no I/O) ≤ 200 mA
All inputs 2 pcs, PNP / NPN High > UB - 1 V, Low < 3 V Input resistance > 20 kOhm Encoder input High > 4 V Outputs 4 pcs, PNP / NPN Inputs / Outputs selectable 4 pcs Maximum output current (per output) 50 mA, Ejector (Pin 12 / RDBU) 100 mA Short-circuit protection (all outputs) Yes Inductive load Typ.: Relais 17 K / 2 H, Pneumatic valve 1.4 K / 190 mH Reverse-polarity protection, U Interfaces VISOR
®
Power-on Delay Typ. 13 s after Power on
Optical data
Number of pixels, chip size, pixel size ACR 300i...:1280 (H) x 1024 (V), 1/1.8", 5,3 µm square
ACR 300i
Vision Sensor
Technology CMOS (mono / colour) Integrated scan illumination 8 LEDs (except C-Mount) White, Red (620 nm), IR (850 nm) Integrated lens, focal length 12 mm, focal position adjustable
Lens (adjustable to innity) ACR 300i, 12 mm
Min. scan distance [mm] 30 Min. eld of view X x Y [mm] 16 x 13
Mechanical data
Length x width x height 65 mm x 45 mm x 45 mm (without plug)
50136796 14.07.2017-00 www.leuze.com/en/usa
Weight Approx.. 160 g
Vibration / shock EN 60947-5-2
Ambient operating temperature 0 °C .... 50 °C (80 % air humidity, noncondensing)
Storage temperature -20 °C ... 60 °C (80 % air humidity, noncondensing)
Enclosure rating IP 65/67
Plug connection 24V DC and I/O: M12 12-pin; LAN: M12 4-pin; Data: M12 5-pin
Housing material Aluminium, plastic
SAFETY INSTRUCTIONS FIELD OF VIEW / OBJECT DISTANCE
Read operating instructions before start-up. Connection, assembly, setting and start-up only by trained personnel. No safety component according to EU machi­nery directives (not suited for the protection of personnel). Not for outdoor use.
Adapters providing eld wiring means are available from the manufacturer. Refer
to manufacturers information. The device shall be supplied from a class 2 rated power supply.
24 V DC, -25 % / +10 %
Yes
Ethernet (LAN), RS422 / RS232, depends on model
INTENDED USE
Sensor is used for the optical, non-contact detection of objects.
COMPONENTS SUPPLIED
ACR 300i Vision Sensor, CD with PC software, installation guide, mounting clamp
(MB-2 300), allen key, screwdriver, and protective cap for Ethernet plug.
ALIGNMENT
Arrangement for bright-eld illumination Arrangement for dark-eld illumination
VISION-SENSOR ACR 300i - ACR...
MECHANICAL INSTALLATION
MB-2 300 (50136487)
(Content of delivery)
MB-1 300
(50136486)
Subject to change
VISION-SENSOR C-MOUNT ACR 300i - ACR...
ELECTRICAL CONNECTION
1
DATA Cable
4
2
Direct connection
3
LAN Cable
5
Network connection
LAN Cable
Power / I/O Cable
LED DISPLAY
1
Pwr Green (Operating voltage)
A
Yellow (Result 1)
B
Yellow (Result 2)
C
Yellow (Result 3)
I/O
CONNECTION SOCKET
3
PIN COL. USE PIN COL. USE
1 BN + Ub (24V DC) 7
M12
FOCUSSING SCREW
2
Focus Clockwise = higher distance
Counter Clockwise = lower distance
2
BK IN / OUT, LED B 2 BU GND 82GY IN / OUT, LED C 3 WH IN (external trigger) 9 RD OUT (ext. illumination) 4 GN READY
2
5
PK IN / OUT (advanced: encoder B+) 11 GYPK VALID
A - coded
*1 Ready: Ready for next ext. trigger. *2 Switchable input - output
*3 VALID: shows available results *4 All LEDs are set without taking into account any timing function (e.g. trigger delay). For shielded cables use shield.
DATA (RS422) M12 CONNECTION SOCKET
4
62YE IN / OUT 12 RDBU OUT (ejector, max. 100mA), LED A
1
10 VT IN (adv.: encoder A+)
LAN M12 CONNECTION SOCKET
5
PIN COL. USE
RS422 RS232
1 BN RxD+ Rx 2 WH RxD- NC 3 BU TxD+ NC
A - coded
4 BL TxD- Tx 5 GR GND GND
D - coded
EXAMPLE ACR 300I - PNP MODE EXAMPLE ACR 300I - NPN MODE
Network-
switch
3
PIN USE
1 TxD+
2 RxD+ 3 TxD­4 RxD-
4
4
4
Subject to change
Loading...