less care Ultra G Series, LBSEG3072, LBSEG3472, LBSDG3472, LBSDG3072 Installation Instructions Manual

SHOWER DOORS • SHOWER ENCLOSURES
INSTALLATION INSTRUCTIONS
SHOWER DOORS:
LBSDG3072 LBSDG3072+LBSEG3072 LBSDG3072+LBSEG3472
LBSDG3472 LBSDG3472+LBSEG3072 LBSDG3472+LBSEG3472
www.lesscare.com
SHOWER ENCLOSURES:
LBSDG3072+LBSEG3072 LBSDG3472+LBSEG3072 LBSDG3072+LBSEG3472 LBSDG3472+LBSEG3472
Version 4.0
SHOWER DOORS • SHOWER ENCLOSURES
ULTRA-G
PREPARATION FOR INSTALLATION
PREPARATION FOR INSTALLATION
READ ALL INSTRUCTIONS BEFORE UNPACKING THE PRODUCT
2 PEOPLE ARE REQUIRED TO LIFT AND DURING ENTIRE INSTALLATION OF THIS PRODUCT
LessCare reserves the right to change, update, modify, alter, redesign this manual/product or its policies without prior notice!
It is your responsibility to visit website to download or contact customer service for the most updated version of the installation instructions.
LessCare shall not be liable for any injuries or property damages in connection with this product during installation or use of this product!
IMPORTANT UNPACKING INSTRUCTIONS:
When you have open top carton box lid, do not take shower glass doors or panels out before you read this and have this items in place. Have a soft cloth blanket min ¼" thick and make sure cloth blanket is bigger then your glass doors or panels in your working area place. Set this soft cloth blanket on the floor of working area. Take out shower glass doors or panels out from the Carton box and set it on the soft cloth blanket. Do not lean it on the wall or floor without the soft cloth blanket.
ATTENTION! Never set glass on floor or tile or solid floor or wall surface without a soft cloth blanket if you set it without soft cloth blanket it will
cause scratches to the tempered glass and this will cause it to shatter right away or when installed or when you start using it, improper handling causes scratches on the glass doors or panels. When installing glass doors or panels be sure your have inspected glass doors or panels fully before installing it. Do not install and Stop installation if you see or find scratches or chipped corners on your glass doors or panels. NEVER set glass doors or panels on its corners make sure the your floor is level with the soft cloth blanket when preparing glass doors or panels for installation.
After opening all boxes and packages, read this introduction carefully. Check that all of the needed parts are included in the package by checking all the components on the diagram of components. Examine boxes and packages for shipping damage. If the unit has been damaged or missing parts, please contact our customer support department immediately. Please note that LessCare will not replace any damaged products or missing parts after 2 business days of the order receipt.
VERY IMPORTANT! Double check all glass corners and four edges of all glass door and panels to make sure that all the glass are in perfect
condition and without any scratches or chipped corners. Do not try to install the shower door, if there is any scratches or chipped corners. Note, that you should consult your local building codes with questions on installation compliance standards. Building and plumbing codes may vary from state to state and location. LessCare is not responsible for code compliance standards for your project and will not accept any returns. Prior to installation, ensure that the installation surface is leveled and solid, and will be able to support the total weight of the unit. Also, make sure the walls are at the right angles. Irregular installation surface level or improper angle of side walls will result in serious problems during installation. Note, that some adjustments and drilling will be necessary during the installation process.
VERY IMPORTANT! Installation of this extremely heavy product to the wall requires minimum of 2" x 4" wood stud framing behind the wall.
INSTRUCTIONS THAT, IF IGNORED COULD RESULT IN SERIOUS INJURY OR DEATH
CAUSED BY INCORRECT HANDLING OR INSTALLATION OF THE PRODUCT.
THESE INSTRUCTIONS MUST BE OBSERVED FOR SAFE INSTALLATION!
LICENSED AND INSURED PROFESSIONAL CONTRACTOR IS REQUIRED TO INSTALL
THIS PRODUCT INCLUDING ASSISTANCE OF A SECOND PERSON DURING INSTALLATION
No modifications to the product are allowed. Modifications of any types to the product will result in serious injuries or may cause death.
IMPORTANT: Do not the handle on to the glass door until the instruction tells you to do so. Never lift the glass using the handle. Failure to do so will result in serious
personal injury and could cause damages to the glass. Professional graded glass suction cups are highly recommended while handling extremely heavy glass. This product must be installed on a finished threshold and against finished walls only. This product is intended for residential use only.
TOOLS REQUIRED
Soft Cloth or Blanket
Safety Glass LevelKnife Caulk Gun Drill Hammer
Silicone Tape
Measure
Pencil/Marker Philips/Straight
Screwdriver
OTHER TOOLS MAY BE REQUIRED
www.lesscare.com
Drill Bit
ø = 5/16"
Drill Bit ø = 1/8"
Soft Wood
Shim
1
SHOWER DOORS • SHOWER ENCLOSURES
SHOWER DOOR MUST BE INSTALLED FIRST
SHOWER DOOR MUST BE INSTALLED FIRST
ULTRA-G
CONFIGURATION STYLES
Min. Threshold Requirement
Min. Threshold Requirement
Min. Threshold Requirement
Min. Threshold Requirement
Shower door
Please use Diagram A for assembly reference.
Pages: 6-12
Shower door with Stationary Panel (Straight Installation)
Please use Diagram A and Diagram B for assembly reference.
Pages: 6-12, 14-19
Shower Door with Stationary Panel (Enclosure Installation)
Please use Diagram A and Diagram B for assembly reference.
Pages: 6-12, 14-19
Threshold Requirement (Size): 7/8"
SAFETY IMPORTANT NOTE: Installation of shower or bathtub door requires to be installed
only on smooth and flat surface of both walls and threshold base (shower base or bathtub).
2
www.lesscare.com
DIAGRAM A
9
8
1
2
3
10
16
SHOWER DOORS • SHOWER ENCLOSURES
ULTRA-G
SHOWER DOOR COMPONENTS
MODELS:
LBSDG3072 LBSDG3472
4
6
7
11
12
13
14
5
15
Item# Item#Qty
1
Wall profile for glass door
2
Glass profile for glass door
3
Side anti-water strip
4
Upper pivot assembly
5
Lower pivot assembly
6
Anti-water strip
7
Handle
8
Bottom anti-water strip
9
Washer for screw
1 pc 1 pc 1 pc 1 pc 1 pc 1 pc 1 pc 1 pc
5 pcs
17
10
Round head screw M3.5x13
11
Screw decorative cover
12
Round head screw M5x60
13
8mm (5/16") wall anchor
14
Round head screw M4x12 with Washer
15
Countersunk Screw M4x40 (optional)
16
Countersunk screw M4x30
17
Glass door
18
Allen key (1 - 3mm, 1 - 4mm)
18
QtyDescription Description
5 pcs 5 pcs 7 pcs 7 pcs 4 pcs
1 pc
2 pcs
1 pc
2 pcs
This door has 1" out-of-plumb adjustment
www.lesscare.com
3
SHOWER ENCLOSURE/STATIONARY PANEL COMPONENTS
DIAGRAM B
19
20
23
28
29
30
26
25
21
30
24
22
GLASS
PROFILE
27
SHOWER DOORS • SHOWER ENCLOSURES
ULTRA-G
MODELS:
LBSEG3072 LBSEG3472
IMPORTANT: Stationary glass with profile has
been factory pre-assembled. Do not try to detach the stationary glass panel with profile (20).
Item# Item#Qty
19
Wall profile for stationary glass panel
20
Stationary glass panel with profile
21
Round head screw M4x60
22
Shelf bracket (for wall)
23
Shelf bracket (for stationary glass panel)
24
Glass shelf
1 pc 1 pc
7 pcs
4 pc 2 pc 2 pc
25
Washer for screws
26
Round head screw M3.5x13
27
Screw decorative cover
28
Countersunk screw M5x30
29
Bottom bracket
30
8mm (5/16") wall anchor
QtyDescription Description
4 pcs 4 pcs 4 pcs 1 pcs 1 pcs 8 pcs
This panel has 1" out-of-plumb adjustment
4
www.lesscare.com
4A
4B
SHOWER DOORS • SHOWER ENCLOSURES
ULTRA-G
PIVOT ASSEMBLY COMPONENTS
4D
4
4C
5C
5E
4E
5F
4F
Item# QtyDescription
4A
Upper Pivot retainer
4B
Countersunk screw M6x14
4C
Pivot body
4D
Plastic washer
4E
Gasket
4F
Back plate
4G
Countersunk screw M6x14
5D
4G
1 pc 1 pc 1 pc 2 pc 2 pc 1 pc 2 pc
5
5G
Item# QtyDescription
5A
5B
5A
Lower Pivot retainer
5B
Countersunk screw M6x14
5C
Pivot body
5D
Plastic washer
5E
Gasket
5F
Back plate
5G
Countersunk screw M6x14
1 pc 1 pc 1 pc 2 pc 2 pc 1 pc 2 pc
Upper Pivot Assembly and Lower Pivot Assembly Disclaimer
Upper and lower pivot assemblies are reversible. For left opening installation Upper Pivot Assembly (4) is used as upper pivot and Lower Pivot Assembly (5) as lower pivot. If you plan to open shower door to the right side, use Lower Pivot Assembly (5) as upper pivot and Upper Pivot Assembly (4) as lower pivot.
NOTE: After installation of all pivots you will have one Countersunk screw M6x14(5B or 4B) unused, because only installation of top
pivot requires that screw. Countersunk screw M6x14(5B or 4B) is optional during Installation of Lower pivot assembly (5 or 4) .
www.lesscare.com
5
SHOWER DOORS • SHOWER ENCLOSURES
ULTRA-G
INSTALLATION STEPS
Single Shower Door Assembly and Installation
NOTE: Use parts from Diagram A for Single
Shower door assembly and installation.
a
1
+0.0
b
1
c
Installation requires minimum of 2" x 4" wood stud framing behind the wall.
d
13
Shower Base
Figure 1
1. Wall profile and Pivot retainers installation
1.1 Place the Wall Profile For Glass Door (1) vertically against the wall
and set it to the shower base or the threshold.
Using a level to level the wall profile upright mark 7 pre-drilled holes on the wall, using a pencil or marker, to prepare for drilling.
Now, drill 7 holes in the wall using 8mm (5/16") Drill Bit. Apply silicone into the holes on the wall. Insert seven 8mm (5/16") Wall anchors (13) and hammer them in.
See Figure 1 for details