Leonics BLUE-800 User Manual

USER’S GUIDE
CONTENT
1. SAFETY INSTRUCTIONS ........................................................................................... 1
1.1 Warning, caution and note ...................................................................................................... 1
1.2 Electrical safety ............................................................................................................................ 1
1.3 Safety instruction for installation and operation ............................................................ 2
1.4 Battery safety ................................................................................................................................ 3
3. FRONT AND REAR PANEL ........................................................................................ 4
3.1 Front panel .................................................................................................................................... 4
3.2 Rear panel ...................................................................................................................................... 6
4. INSTALLATION ......................................................................................................... 7
4.1 Preparation .................................................................................................................................... 7
4.2 Installation and operation ....................................................................................................... 7
5. OPERATION .............................................................................................................. 8
5.1 Turn on and turn o the UPS ................................................................................................. 8
5.2 Software installation .................................................................................................................. 8
5.3 Testing operation ........................................................................................................................ 8
5.4 Storage ........................................................................................................................................... 8
5.5 Battery replacement.................................................................................................................. 8
6. TROUBLESHOOTING ............................................................................................... 10
MICROPROCESSOR CONTROL AND
LINE INTERACTIVE UPS WITH STABILIZER
7. SPECIFICATIONS ...................................................................................................... 11
- 1 -
- 2 -
SAFETY INSTRUCTIONS
Please read carefully and follow this user’s guide carefully and completely.
Important: Please keep this user’s guide for reference in order to use the UPS properly and safety. This user’s guide consists of safety instructions, introduction, front and rear panel, installation, operation and troubleshooting.
For product safety, please check this product annually by our service qualied personnel or if there are any symptom of problems which are not mentioned in this guide or any queries, please contact your LEONICS distributors, LEONICS service center, send e-mail to marketing@lpsups.com or visit our website at www.leonics.com
For your convenience and quick reference for our service, pleas ll the requested informations in the blanks below: UPS Model: Serial Number: Purchased Date: Purchased From:
1.1 Warning, Caution and Note
To reduce risk of electrical shock hazards, and to make sure the inverter is safety installed, special symbols of Warning, Catuions and Note are used in this guide to highlight potential safety hazards and important safety information as follow:
Warning: Indicates a potentially hazardous situation or safety information important for human safety. Violation of warnings may result in death or serious injury and damage to the unit or other equipment.
Caution: Indicates a potentially hazardous situation or the information important for the protection of property. Violation of caution may result in minor or moderate injury and damage to the unit or other equipment.
" Note: Indicates useful additional information that helps you make better use of product and system.
1.2 Electrical Safety
Only qualied electricians allow to install and wiring this unit and system.
Periodically check your cable, outlets, terminal blocks and power source to make sure that they
are in good condition.
To reduce risk from electric shock, if you cannot nd the electrical ground ( ) of the building,
unplug UPS from AC power source before connect loads to the UPS. Then, plug in the UPS to AC power source.
Use ONLY one hand when plugging or unplugging the loads in order to avoid electric shock
from touching two surfaces with dierent potential.
It is recommended to connect the UPS to a three wires AC power source (two live wires and an
electrical ground) which connects to a protected circuit such as employs a fuse or circuit breaker.
1.3 Safety instruction for installation and operation
Caution: Before installing or using this unit, read all instructions and caution markings on the UPS and all connected loads, and all sections of this user guide.
Caution: Install this unit in a temperature and humidity controlled area with adequate air ow and away from chemical particles or ammable substances. Avoid installing the unit near radio transmission station, heat dissipation equipment and direct sunlight.
Caution: For AC power source connection, it is recommended to connect with a properly grounded power source which connects to a protected circuit such as employs a fuse or circuit breaker according to the electricity authority’s standards. The AC power source connection point must be a proper location and easyily accessible.
Caution: DO NOT connect the AC input cable into the AC output terminal. This may cause the unit damaged.
Caution: DO NOT block the ventilation grills and DO NOT put any objects on the top of the unit. Ensure that sucient ventilation is provided.
Caution: This UPS is not intended for use with life rescue equipment! A failure of the UPS might cause the life rescue equipment to fail and endanger human lives.
Caution: Periodically check your cable, terminal and power source to make sure that they are in good condition.
Warning: Risk of electric shock, DO NOT remove cover. No user serviceable parts inside, please refer servicing to qualied service personnel.
Warning: DO NOT work alone where there are electrically hazardous conditions.
Warning: Contact with live conductors will cause burns and dangerous electric shock. DO NOT touch any terminal or internal parts of the unit while the unit is operating.
The distance of minimum 30 cm. between the wall and the unit is necessary for adequate
ventilation and easy access for installation, operation and maintenance.
Use insulated tools to reduce your risk of electric shock.
Remove all jewelry or other metal objects such as rings, necklace, bracelets and watches when
installing this product.
Verify correct terminal block connections to prevent the damage occurs.
- 3 -
- 4 -
Before connecting the communication interface signal cable, turn o the UPS and disconnect the UPS from AC power source.
DO NOT clean the UPS with benzene, thinner or any solvent, use only soft cloth to clean the UPS
after it has been turned o.
Turn on the UPS before turn on all connected loads to prevent surge damage.
During a heavy rain storm, avoid using electrical appliances including the UPS to prevent
damage from lightning strike.
1.4 Battery Safety
Warning: Even the UPS is disconnected from AC power source, the UPS OUTPUT outlets may have hazardous voltage because of battery may continue supply power.
Warning: DO NOT dispose of battery in a re. They may be exploded.
Caution: DO NOT disassemble battery. They contains poisonous electrolyte which is harmful to your skin and eyes.
Caution: For battery replacement, replace battery with the same type and rating as originally installed battery.
Caution: The UPS contains sealed lead acid battery and must be recycled properly. For recycling, please return it to ypur local distributor or service center or contact your local recycling center for proper disposal information.
Caution: When the UPS has not been used for a long period of time or UPS is stored for an extended period of time, battery should be fully recharged every three months by plugging the UPS with the AC power source. Then, turn on the UPS and let the UPS charge battery for 6 hours.
INTRODUCTION
2.1 General
BLUE series is an uninterruptible power supply for oce automation equipment (computers and peripherals such as monitors, modem, printers, fax machines, etc). Its major function is to eliminate any power problems such as a blackout, brown out, sag, surge, spike, etc. that might cause malfunctions of the connected loads. It also provide automatic voltage regulator (AVR), surge suppressor and backup power system. The BLUE series UPS can be started when there is no utility power to supply power the connected loads in an emergency. It display the electrical status and operating status on LCD display and on computer's monitor via UPS monitoring software.
FRONT AND REAR PANEL
3.1 Front panel
When replacing a battery, use tools with insulated handles and remove any watch, rings or
other metal objects that you wear in order to avoid electric shock.
Loading...
+ 4 hidden pages