LEO AJm150, AJm90S, AJM150L, AJm90, AJm110 User guide

SS
Anti-Rust
SS Shaft
Copper & Cold-rolled
SELF-PRIMING JET PUMPS
AJm
CONTENTS
1. Applications
3. Technical Data
4. Implementation Standards
5. Safety Precautions
6. Product Structure
7. Pipeline Installation
8. Electrical Connection
9. Start-up and Maintenance
10. Troubleshooting
....................................
............................
................................
..........................
............................
.........................
......................
..............................
................
................
2
2
2
3
3
5
6
8
10
11
AJm
Self-priming Jet Pumps
Symptom Cause Corrective Action
Motor works intermittently or the stator winding is burned out
The impeller is jammed or under overload operation for a long time.
Incorrect grounding, broken cable or the electric pump is hit by lightning.
Clear sundries in the pump chamber; operate the pump under the rated flow as much as possible.
Seek for the reason, and replace winding coils.
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Attention!
If the appliance or the supply cord is damaged, it must be repaired by manufacturer, its service agent or qualified person.
Meaning of crossed –out wheeled dustbin: Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact you local government for information regarding the collection systems available.
112
AJm
Self-priming Jet Pumps
Before installation, you should carefully read this manual, and pay attention to safety cautions and instructions in this manual. Our factory is neither responsible for nor is reliable for paying compensation for personal injury, pump damage and other property losses caused by violation of safety cautions.
1. Applications
1) It is applicable to household water supply, equipment support, well water lifting, pipeline pressurization, garden watering, vegetable greenhouse watering, fish farming and poultry raising, etc..
2) Transfer clean water and other non-corrosive liquids with low viscosity; do not transport inflammable, explosive, gasified liquids and liquids containing solid particles or fibers. The PH of water must between 6.5 and
8.5.
Remark:
This series of pump could be transformed into automatic water pump, which is realized through external automatic plant that is composed of pressure switch, pressure tank, etc.. Function features of the automatic pump are as follows: when the power is on, turn on the water tap and the pump will start working automatically; when the water tap is turned off, the pump will stop working automatically. If a water tower is used along with the automatic pump, connect to the upper limit switch and the pump will start or stop working automatically with water level in the water tower.
2. Model Description
AJ m x x
Feature: S-Stainless steel pump body Rated power(x 10W) Single phase motor, m for single phase only LEO3.0 Series Jet Pump
3. Technical Data
Max. flow: 140L/min Max. head: 90m Output power: 0.3~2.2kW Max. Suction: 9m Insulation class: IPX4 Protection class: F Max. ambient temperature: +40 Max. liquid temperature: +60
10. Troubleshooting
Check the pump after power cut-off.
Symptom Cause Corrective Action
a. repair switch contact or replace the switch; b. replace the safety fuse; c. check and tighten the power connector; d. repair or replace cables
Replace with a same type capacitor (send to the maintenance point for repair).
Replace the bearing (send to the maintenance point for repair).
Turn rotating shaft of the fan blade terminal with screw driver to let it rotate flexibly or demount the pump body to clear sundries.
Replace winding coils (send to the maintenance point for repair).
Invert two-phase wirings of the motor (three-phase motor).
Re-fill the pump with water.
Replace the impeller (send to the maintenance point for repair).
Check sealing of various joints of the inlet pipelines.
Adjust installation height of the pump.
Start up the pump after ice is melted.
Replace the damaged parts(send to the maintenance point for repair).
Select suitable pump. Apply the pipe with the stipulated
diameter, and make the inlet pipe short.
Clean pipeline, foot valve or pump chamber, clean foreign materials.
The motor can not be started
The motor is in operation, but no water is discharged
Insufficient pressure
Single-phase power supply (three-phase electric motor): a. poor connection of the power switch; b. fuse is burned out; c. loose power cable; d. phase failure of the cable.
Capacitor is burned out.
The rotating shaft and bearing are jammed.
Impeller is jammed.
Stator winding is damaged.
Incorrect direction of pump rotation.
The pump is not fully filled with water.
The impeller is damaged.
Leakage of the suction pipe.
Water level is too low.
Freeze caused by accumulated water in the pipeline or the chamber.
Water that is too hot can result in the failure of plastic parts.
Incorrect pump type. The inlet pipeline is too long or with
too many bends, pipe diameter is not selected as required.
Inlet pipeline, filter screen or pump chamber is blocked by foreign materials.
112
AJm
Self-priming Jet Pumps
9. Start-up and Maintenance
Do not start up the pump before the pump chamber is filled with water. Do not touch the electric pump unless its power has been cut off for at least 5 minutes. Do not dismount the pump body unless water in the pump chamber is empted.
Rotate the fan blade before start­up, check whether the pump ro tation is flex ib le and then unscrew the water-filling plug, fill the pump chamber with clean water from the water injection hole, then tighten the plug screw after the air has been completely discharged. Set the valve in a smaller flow in start-up and adjust to the required flow after water discharging (working range is displayed on the nameplate).
Attention:
The pump chamber should be filled with water before first use and water
1 .)
refilling is unnecessary in the future. In case no water is discharged after being started for more than 5 minutes
2).
with water filled, turn off the electric pump, re-fill water or check whether the inlet pipeline has leakages. In case of any frost and ice damages, please open the drain plug to empty
3).
water in the pump chamber. When start up the pump again, open the drain plug, fill water and tighten it and then the pump is usable.
4).
In case not use for a long time, water in the pump should be emptied. The pump body, impeller and support should be cleaned and coated with anticorrosive oil before they are put in a ventilated and dry place for use. In case the pump is halted for a long time, start it up again according to
5).
above diagram.
6).
In summer or when the ambient temperature is high, pay attention to ventilation, avoid dew on electrical parts which will result in electrical faults. In case the motor is hot or abnormal, cut off the power immediately and
7).
check faults according to the following table.
4. Implementation Standards
IEC/EN 60335-1 Household and similar electrical appliances--safety Part1: General requirements. IEC/EN 60335-2-41 Household and similar electrical appliances--safety Part2-41:Particular requirements for pump. 2006/95/EC Low voltage directive
5. Safety Precautions
1. To ensure normal and safety operation of the electric pump, read the manual carefully before use.
l
ua
n
a
M
ON
OFF
1
1
0
0
2. The electric pump should have reliable grounding to prevent short circuit; for safety, leakage protection switch should be equipped and be careful no to wet the power plug; socket should be connected in damp - proof area.
3. Do not touch the electric pump while working; do not wash, swim near working area or let livestock into the water to avoid accidents .
4. Avoid splashing pressured water to the electric pump as well as prevent the pump immersed by water.
310
AJm
Self-priming Jet Pumps
5. Keep the pump in ventilation.
OFF
6. In case ambient temperature is lower than 4or the pump is not used for a long time, empty liquid the pipeline system to avoid ice cracking of the pump chamber. Do not operate the pump for a long time without water in it.
OFF
7. The pumped liquid maybe hot and under high pressure, before moving and demounting the bump, valves in both sides of the bump should be turned off first and then empty liquids in the pump and pipelines so as not to be scalded.
8. Do not transfer any inflammable, explosive or gasified liquids that beyond the stipulation.
6) Automatic device(Pressure switch)
While using the automatic pump, in case it still operates after turning off
6.1 .)
the water tap, lower down power cut-off pressure of the pressure switch on the premise of pipeline without leakage, namely, rotate the variable screw nut II in counterclockwise direction (-) to acquire lower closing pressure. In case the pump is often enabled when the water tap is turned off
6.2).
(sometimes it is turned on and sometimes it is turned off), check whether pipeline and the bottom valve have leakages and pressure vessel pressure is normal, eliminate timely if any. In case the pressure switch is alternately turned on and turned off
6.3).
(frequent start) after turning on the water tap, increase power cut-off pressure of the pressure switch, namely, rotate the variable screw nut I in clockwise direction to acquire higher opening pressure.
9. Ensure the pump will not be accidently turned on while installing and maintaining; if not used for a long time, cut off the power first and then turn off valves in inlet and outlet of the pump.
AJm75
-6
Q 10 5 l/min
H 36-23 m
Hmax 40 m
V 180-220 ~
Hz 50
Hmin 23 m
kW 0.75
HP 1.0
In 6.0 A
-1
min
2900
Size 1" x 1"
IP X4
C 16 μF
VL 450 V
l CL F
Continuous duty Thermally protected
n.
www.leogroup.cn
10. Power supply should be in accordance with the voltage stated in the nameplate. If not used for a long time, put the pump in dry, ventilated and cool place under room temperature.
94
AJm
Self-priming Jet Pumps
8. Electrical Connection
Unless the power is off, do not wiring the junction box. The electric pump should have reliable grounding to prevent current leakage with leakage protection switch being equipped.
Electrical connection and protection should be conducted according to
1 .)
stipulations. Specification of working voltage is marked on the nameplate; please ensure the motor is in accordance with power supply.
2).
In case the working area of the electric pump is too far from the power supply, power transmission lines should be of a heavier gauge, otherwise the electric pump cannot work normally because the voltage drop is too dramatic. A rubber extension cable shall be applied for the electric pump in case of
3).
outdoor use. Check rotation of the motor (three-phase motor).
4).
5).
Check whether operation of the electric pump is normal, rotation is correct, which could be observed from the fan blade terminal, e.g. clockwise rotation means correct direction. In case the rotation is incorrect, cut off power and exchange the two power cables.
~2 20V ~2 20V ~3 80V ~3 80V
switch
fuse
junction box of the motor
pressure switch
junction box of the motor
magnetic thermal switch
switch
fuse
junction box of the motor
pressure switch
junction box of the motor
magnetic thermal switch
6. Product Structure
POS.
Part
1
Pump body
2
Diffuser
3
Impeller
4
Mechanical seal
5
Seal holder
6
Pump support
7
Bearing
8
Rotor
9
Spring washer
POS.
10 11 12 13 14 15 16 17 18
Part Fan cover Fan End plate Capacitor Capacitor box Terminal board Stator Bracket Cable holder
58
AJm
Self-priming Jet Pumps
7. Pipeline Installation
This product should be installed and maintained by personnel who is proficient in this manual and has special qualifications. Installation and operation should be in accordance with local regulations and recognized operation standards. Install pipelines properly as stipulated in the manual and meanwhile conduct frost protection measures for the pipeline.
Max. water temperature: + 40 Min. water temperature: +4
1. For pump installation, the inlet pipe should be as short as possible with the least turnings. The pump s h o u l d b e installed in ventilated and dry environment. It could b e i n s t a lled o u t s i d e , provided having proper covering to prevent rain and wind.
2. For pipeline use, valves should be instal led on inlet and outlet pipelines and the inlet pip eline should be installed with check valve.
5
4
6
7
3
1 2
8
Correct Installation Diagram
Incorrect Installation Diagram
B1 B2
A:
1. Drain Plug
2. Electric pump
3. Water tap
4. Outlet pipe
B: Installation precautions for inlet pipelines
1 .)
While installing the electric pump, do not use too soft rubber tube for the inlet pipeline, avoiding to be sucked flat. The foot valve should be vertically
2).
placed and installed 30cm from water bottom to avoid sucking in sands and stones (B2); Joints of the inlet pipelines should be
3).
sealed with the least elbows, no water can be sucked. Diameter of the inlet pipe should be
4).
A
B
at least in accordance with that of the water inlet, so as to avoid too much water loss which will influence outlet performance. Pay attention to drop of water level
5).
while using, the foot valve should not be above the water surface (B1). In case the inlet pipe is longer than
6).
10m or its lifting height exceeds 4m, the pipe diameter should exceed diameter of water inlet of the pump. Ensure the pumped will not be
7).
affected by pipeline pressures while installing the pipelines. Filter should be installed in inlet
8).
pipelines so as to avoid solid particles to enter into the electric pump.
C: Installation Precautions of the outlet pipeline
Pipe diameter of the outlet pipeline should be at least in accordance with that of the water outlet, so as to reduce its voltage drop, high flow rate and noise to the minimum.
5. Filling plug
6. Tie-in
7. Inlet pipe
8. Foot valve
76