Lenovo 7159A1X, 7159-HD1 operation manual

Lenovo ThinkSystem NE1032 RackSwitch
Product Guide
The Lenovo ThinkSystem NE1032 RackSwitch is a 1U rack-mount 10 Gb Ethernet switch that delivers lossless, low-latency performance with feature-rich design that supports virtualization, Converged Enhanced Ethernet (CEE), high availability, and enterprise class Layer 2 and Layer 3 functionality. The switch delivers line-rate, high-bandwidth switching, filtering, and traffic queuing without delaying data.
The NE1032 RackSwitch has 32x SFP+ ports that support 1 GbE and 10 GbE optical transceivers, active optical cables (AOCs), and direct attach copper (DAC) cables. The switch helps consolidate server and storage networks into a single fabric, and it is an ideal choice for virtualization, cloud, and enterprise workload solutions.
The Lenovo ThinkSystem NE1032 RackSwitch is shown in the following figure.
Figure 1. Lenovo ThinkSystem NE1032 RackSwitch
Did you know?
The NE1032 RackSwitch provides reliable, high-performance fabric for traditional, converged, and hyperscale solutions.
The NE1032 RackSwitch runs the Lenovo Cloud Networking Operating System (CNOS) that provides a simple, open and programmable network infrastructure with cloud-scale performance. It delivers a software-defined Ethernet solution that is simple to manage and easy to deploy using common management tools, and it enables support of automation and orchestration applications for tight integration into the data center ecosystem.
The NE1032 RackSwitch supports the Open Network Install Environment (ONIE) which is a small Linux­based operating system that provides an open install environment for networking devices without operating systems.
Click here to check for updates
Lenovo ThinkSystem NE1032 RackSwitch 1
Key features
The NE1032 RackSwitch runs the Cloud NOS that provides a simple, open and programmable network infrastructure designed to scale for your business needs. Its intelligent, cloud-scale performance delivers a software-defined Ethernet solution that is simple to manage and easy to deploy using common management tools. Cloud NOS is based on open, industry standards for better data center interoperability, and it enables support of automation and orchestration applications for tight integration into the data center ecosystem.
With its high-performance architecture and support for an extensive set of routing protocols, Cloud NOS provides reliable, high-performance fabric for traditional, converged and hyperscale solutions. Cloud NOS can help you consolidate server and storage networks into a single fabric. Converged Enhanced Ethernet delivers value for your iSCSI and NAS enterprise storage environments.
The NE1032 RackSwitch is considered particularly suited for the following environments:
1 GbE or 10 GbE SFP+ connectivity for server, storage, or uplink switch connections
Cloud and virtualization solutions with VM-aware network automation and integration into Lenovo and third-party IT and cloud infrastructure management tools
Converged SAN and LAN network via NAS and iSCSI storage connectivity
Reduced I/O cost (CAPEX) with fewer adapters and cables to purchase Reduced complexity (OPEX) with fewer components to manage and lower energy cost
Hyperconverged solutions
Applications demanding better performance and lower latency
The NE1032 RackSwitch offers the following features and benefits:
High performance The 10 Gb NE1032 RackSwitch provides a combination of low latency, non-blocking line-rate switching, and ease of management with 640 Gbps throughput.
Lower power and better cooling The front-to-rear or rear-to-front cooling design of the NE1032 RackSwitch reduces data center air conditioning costs by having airflow match the servers in the rack. In addition, variable-speed fans help reduce power consumption.
Layer 3 functionality The NE1032 RackSwitch includes Layer 3 functionality, which provides security and performance benefits, as inter-VLAN traffic stays within the switch. This switch also provides the full range of Layer 3 protocols from static routes for technologies, such as Open Shortest Path First (OSPF) and Border Gateway Protocol (BGP) for enterprise customers.
Converged fabric The NE1032 RackSwitch supports Converged Enhanced Ethernet (CEE) which helps enable customers to combine storage, messaging traffic, VoIP, video, and other data on a common data center lossless Ethernet infrastructure. As a result, customers can deploy a single server interface for multiple data types, which can simplify the deployment and management of server network connectivity while maintaining the high availability and robustness that is required for storage transactions.
Fault tolerance The NE1032 RackSwitch offers redundant hot-swap hardware components, learns alternate routes automatically, and performs faster convergence if there is a link, switch, or power failure.
Seamless interoperability RackSwitch switches perform seamlessly with other vendors' upstream switches.
Lenovo ThinkSystem NE1032 RackSwitch 2
Automated VM-aware network provisioning The Lenovo CNOS Network Policy Agent, a ThinkAgile Network Orchestrator feature, gives increased visibility of the virtual infrastructure, including VM and virtual network information. It provides automated VM-aware provisioning by automatically configuring VLANs in the physical network based on the auto-discovered virtual network topology. The agent also performs ongoing dynamic updates to the physical network configuration in response to new VMs, updated VMs, and deleted VMs and virtual networks, eliminating errors with manual configuration. Note: The Network Policy Agent works with the Nutanix Acropolis Hypervisor (AHV) and Nutanix Acropolis software version 5.0.2 or higher.
Pro-active congestion monitoring Telemetry enables continuous monitoring of networking devices to detect potential congestion problems, such as packets dropped by the switch when ports are being used close to their line rate or switch buffers are being temporarily overflown (for example, in case of microbursts).
Zero Touch Provisioning Zero Touch Provisioning (ZTP) enables a switch to automatically provision itself using the resources available on the network, without manual intervention. ZTP automatically handles the process of upgrading the switch software image and installing configuration files.
Python Scripting Network administrators can create and execute local Python scripts on switches to make small programs that allow a switch to automatically provision itself, perform fault monitoring, upgrade the image files, or auto-generate configuration files. Administrators can also implement version control systems, automatically generate alerts, create custom logging tools, and automate the management of network devices.
REST API Programming The Lenovo REpresentational State Transfer (REST) Application Program Interface (API) enables network administrators to remotely configure and manage a Lenovo switch using REST and HyperText Transfer Protocol (HTTP). It also allows switch management integration into management applications, such as Lenovo xClarity.
Open Network Install Environment (ONIE) (Requires an optional license key)
The ONIE is a small Linux-based operating system that provides an open install environment for networking devices without operating systems. ONIE enables a network switch ecosystem for end users to choose among different Network Operating Systems by discovering NOS installer images and loading them onto the switch.
Components and connectors
The following figure shows the front (port-side) panel of the NE1032 RackSwitch.
Figure 2. Front panel of the NE1032 RackSwitch
Lenovo ThinkSystem NE1032 RackSwitch 3
The front panel of the NE1032 RackSwitch includes the following components:
32x SFP/SFP+ ports to attach SFP/SFP+ transceivers for 1 Gb or 10 Gb Ethernet connections or DAC cables and AOCs for 10 Gb Ethernet connections.
One RJ-45 10/100/1000 Mb Ethernet port for out-of-band management.
One Mini-USB RS-232 console port that provides another means to configure the switch.
One USB port for mass storage devices.
LEDs that display the status of the switch and the network.
Reset button.
Switch information pull-out tab.
The following figure shows the rear (non-port-side) panel of the NE1032 RackSwitch.
Figure 3. Rear panel of the NE1032 RackSwitch
The rear panel of the NE1032 RackSwitch includes the following components:
Two redundant hot-swap 770 W AC power supplies (each with the IEC 320-C14 power connector) Three N+1 redundant hot-swap fan assemblies
Lenovo ThinkSystem NE1032 RackSwitch 4
System specifications
The following table lists the NE1032 RackSwitch system specifications.
Note: The supported hardware options and software features listed in this product guide are based on the Lenovo Cloud Networking Operating System (CNOS) version 10.4.2. For details about specific CNOS software releases that introduced support for certain hardware options and software features, refer to the Change history of the particular software release that can be found at:
http://datacentersupport.lenovo.com/us/en/products/networking/rackswitch/NE1032/7159/downloads
Table 1. NE1032 RackSwitch system specifications
Component Specification
Form factor 1U rack mount
Ports 32x SFP/SFP+ ports
Media types 10 Gb Ethernet SFP+:
10 GbE short-range (SR) SFP+ transceivers 10 GbE long-range (LR) SFP+ transceivers 10 GbE extended-range (ER) SFP+ transceivers 10 GbE SFP+ active optical cables 10 GbE SFP+ DAC cables
1/10 Gb Ethernet SFP+:
1/10 GbE SX/SR SFP+ transceivers
1 Gb Ethernet SFP:
1 GbE short-wavelength (SX) SFP transceivers 1 GbE long-wavelength (LX) SFP transceivers 1 GbE RJ-45 SFP transceivers
Port speeds 10 GbE SFP+ transceivers, DAC cables and AOCs: 10 Gbps
1/10 GbE SFP+ transceivers: 1 Gbps or 10 Gbps 1 GbE SFP transceivers: 1 Gbps
Switching method Cut-through.
Data traffic types Unicast, multicast, broadcast.
Software features Lenovo Cloud Networking OS (CNOS):
Layer 2 switching, Layer 3 switching, virtual local area networks (VLANs), VLAN tagging, spanning tree protocol (STP), link aggregation (trunk) groups (LAGs), virtual LAGs (vLAGs), quality of service (QoS), IPv4/IPv6 management, IPv4/IPv6 routing, IPv4/IPv6 virtual router redundancy protocol (VRRP), IPv4/IPv6 policy-based routing (PBR), Converged Enhanced Ethernet, Network Policy Agent, Python scripting, REST API programming, Telemetry agent.
Performance Non-blocking architecture with wire-speed forwarding of traffic:
100% line-rate performance Up to 640 Gbps switching throughput As low as 760 ns port-to-port switching latency Up to 476 Million packets per second (Mpps) (64-byte packets) Up to 9,216-byte jumbo frames Buffer size: 12 MB
Scalability MAC address forwarding database entries: 208,000
VLANs: 4,095 (3,999 user-configurable; 96 reserved) Rapid Per VLAN Spanning Tree (RPVST) instances: 500 Multiple STP (MSTP) instances: 64 Link aggregation groups: 32 Active ports in a link aggregation group: 32 Maximum ingress ACL entries: 3,072 Maximum egress ACL entries: 512
Lenovo ThinkSystem NE1032 RackSwitch 5
Cooling Three N+1 redundant hot-swap fans. Rear (non-port side) to front (port side) or front to rear
airflow.
Power supply Two load-sharing, redundant hot-swap 770 W AC (100 - 240 V) power supplies (each power
supply has an IEC 320-C14 connector).
Hot-swap parts SFP/SFP+ transceivers, SFP+ DAC cables and AOCs, power supplies, fans.
Management ports
1x 10/100/1000 Mb Ethernet port (RJ-45); 1x RS-232 port (Mini-USB); 1x USB 2.0 port (for additional firmware, log, and configuration files storage).
Management interfaces
Industry standard command line interface (isCLI); SNMP v1, V2, and v3; REST API. Optional Lenovo XClarity for discovery, inventory, monitoring and events. Optional Lenovo Networking Content Pack for VMware vRealize Log Insight. Optional Lenovo Networking Neutron Plugin for OpenStack-based environments. Ansible support for IT automation. Ganglia support for telemetry analytics.
Security features Secure Shell (SSH); Secure Copy (SCP); Secure FTP (sFTP); user level security; Role-based
Access Control (RBAC); LDAP, RADIUS, and TACACS+ authentication; access control lists (ACLs); Trusted Platform Module (TPM) 1.2.
Hardware warranty
Three-year (Machine Type 7159) Customer Replaceable Unit limited warranty with 9x5 Next Business Day Parts Delivered. Optional warranty service upgrades are available through Lenovo: Technician Installed Parts, 24x7 coverage, 2-hour or 4-hour response time, 1-year or 2-year warranty and post-warranty extensions, 1-year or 3-year Remote Technical Support (RTS).
Software maintenance
Three-year software support and subscription is included in the base warranty. Optional 1­year and 2-year warranty extensions include software support and subscription.
Mean Time Between Failures (MTBF)
196,927 hours.
Dimensions Height: 44 mm (1.7 in.); width: 441 mm (17.3 in.); depth: 487 mm (19.2 in.)
Weight 10.7 kg (23.6 lb).
Component Specification
Lenovo ThinkSystem NE1032 RackSwitch 6
Models
The following table lists the NE1032 RackSwitch models.
Table 2. NE1032 RackSwitch models
Description
Part number
Machine Type-Model
Feature code
Lenovo ThinkSystem NE1032 RackSwitch (Rear to Front) 7159A1X 7159-HD1 AU3A
Lenovo ThinkSystem NE1032 RackSwitch (Front to Rear) 7159A2X 7159-HD2 AU39
The part numbers for the NE1032 RackSwitch models include the following items:
One NE1032 RackSwitch with two power supplies and three fan assemblies (rear-to-front airflow or front-to-rear airflow) Generic Rack Mount Kit (2-post) Console Cable Kit that includes the following items:
RJ-45 (plug) to RJ-45 (plug) serial cable (1 m) Mini-USB to RJ-45 (jack) adapter cable (0.2 m) with retention clip DB-9 to RJ-45 (jack) adapter
Electronic Publications Flyer
Configuration notes:
Power cables are not included and must be ordered together with the switch (see Power supplies
and cables for details).
QSFP+ and SFP/SFP+ transceivers and cables are not included and should be ordered together with the switch (see Transceivers and cables for details).
The NE1032 RackSwitch supports Features on Demand (FoD) license keys to enable additional features. The ONIE FoD option enables customers to download an ONIE boot loader and install it on the switch, and the Advanced Instrumentation Tools FoD option enables access to low-level switch diagnostics for advanced troubleshooting.
The following table lists the FoD upgrade options for the NE1032 RackSwitch.
Table 3. FoD upgrade options
Description
Part number
Feature code
Lenovo ThinkSystem NE1032 RackSwitch Advanced Instrumentation Tools 7ZN7A04281 AXDK
Lenovo ThinkSystem NE1032 RackSwitch ONIE Instrumentation Tools 7ZN7A04282 AXDJ
Lenovo ThinkSystem NE1032 RackSwitch 7
Transceivers and cables
With the flexibility of the NE1032 RackSwitch, customers can choose the following connectivity technologies:
For 1 GbE links, customers can use SFP transceivers with RJ-45 UTP cables for distances up to 100 meters.
For longer distances, the 1000BASE-SX transceiver supports distances up to 220 meters with
62.5 µ multimode fiber (OM1) and up to 550 meters with 50 µ multimode fiber (OM2), or the 1000BASE-LX transceiver supports distances up to 10 kilometers with single-mode fiber (1310 nm).
For 10 GbE links, customers can use 10 GbE SFP+ direct-attached copper (DAC) cables for distances up to 7 meters, or 10 GbE SFP+ active optical cables (AOCs) for distances up to 20 meters. The AOCs and DAC cables have SFP+ connectors on each end, and they do not need separate transceivers.
For longer distances, the 10GBASE-SR transceiver supports distances up to 300 meters over OM3 multimode fiber or up to 400 meters over OM4 multimode fiber. The 10GBASE-LR transceivers can support distances up to 10 kilometers on single mode fiber. For extended distances, the 10GBASE­ER transceivers can support distances up to 40 kilometers on single mode fiber.
The following table lists the supported cables and transceivers.
Table 4. Supported SFP/SFP+ transceivers and cables
Description
Part number
Feature code
Maximum quantity supported
SFP transceivers - 1 GbE
Lenovo 1000BASE-T (RJ-45) SFP Transceiver (no 10/100 Mbps support) 00FE333 A5DL 32
Lenovo 1000BASE-SX SFP Transceiver 81Y1622 3269 32
Lenovo 1000BASE-LX SFP Transceiver 90Y9424 A1PN 32
SFP+ transceivers - 10 GbE
Lenovo Dual Rate 1/10Gb SX/SR SFP+ Transceiver 00MY034 ATTJ 32
Lenovo 10GBASE-SR SFP+ Transceiver 46C3447 5053 32
Lenovo 10GBASE-LR SFP+ Transceiver 90Y9412 A1PM 32
Lenovo 10GBASE-ER SFP+ Transceiver 90Y9415 A1PP 32
Optical cables for 1 GbE SX SFP and 10 GbE SR SFP+ transceivers
Lenovo 0.5m LC-LC OM3 MMF Cable 00MN499 ASR5 32
Lenovo 1m LC-LC OM3 MMF Cable 00MN502 ASR6 32
Lenovo 3m LC-LC OM3 MMF Cable 00MN505 ASR7 32
Lenovo 5m LC-LC OM3 MMF Cable 00MN508 ASR8 32
Lenovo 10m LC-LC OM3 MMF Cable 00MN511 ASR9 32
Lenovo 15m LC-LC OM3 MMF Cable 00MN514 ASRA 32
Lenovo 25m LC-LC OM3 MMF Cable 00MN517 ASRB 32
Lenovo 30m LC-LC OM3 MMF Cable 00MN520 ASRC 32
SFP+ active optical cables - 10 GbE
Lenovo 1m SFP+ to SFP+ Active Optical Cable 00YL634 ATYX 32
Lenovo 3m SFP+ to SFP+ Active Optical Cable 00YL637 ATYY 32
Lenovo 5m SFP+ to SFP+ Active Optical Cable 00YL640 ATYZ 32
Lenovo ThinkSystem NE1032 RackSwitch 8
Loading...
+ 17 hidden pages