Lenovo 6Gb SAS Host Bus Adapter User Manual

6Gb SAS Host Bus Adapter
Product Guide
The 6Gb SAS Host Bus Adapter (HBA) is an economical storage enabler to attach RAID-capable external storage enclosures and provide 3 Gbps or 6 Gbps tape storage connectivity for data archiving applications to achieve a higher level of performance.
The PCIe small form-factor 6Gb SAS HBA is based on the LSI SAS2008 controller and can handle medium to large capacity server storage applications by connecting an 8-lane PCI Express adapter with one external x4 SFF-8088 connector and four internal SATA connectors.
The 6Gb SAS Host Bus Adapter is shown in Figure 1 (with the 3U bracket removed).
Figure 1. 6Gb SAS Host Bus Adapter
Did you know?
6 Gbps SAS 2.0 technology has been introduced to address data off-load bottlenecks in the direct-access storage environment. This new throughput doubles the transfer rate of the previous generation. SAS 2.0 is designed for backward compatibility with 3 Gbps SAS as well as with 3 Gbps SATA hard drives and tape drives.
Click here to check for updates
6Gb SAS Host Bus Adapter 1
Part number information
Table 1 shows the part number to order these HBAs.
Withdrawn: This adapter is now withdrawn from marketing.
Table 1. Part number and feature code for ordering
Description Part number Feature code
6Gb SAS HBA 46M0907 5982
Part number 46M0907 includes the following items:
One 6Gb SAS Host Bus Adapter with full-height (3U) bracket attached
Low-profile (2U) bracket
Documentation package
Features and specifications
The 6Gb SAS Host Bus Adapter has the following specifications:
SAS Controller: LSI SAS2008
Eight SAS/SATA ports (four external, four internal)
Up to 6 Gbps per port data transfer rate
Four internal SATA x1 connectors
One external SAS x4 connector (SFF-8088)
PCI Express x8 2.0 host interface
MD2 small form factor
High performance I/O Processor: PowerPC 440 @ 533 MHz
UEFI support
RAID levels: None (uses RAID as provided by external disk enclosures)
Maximum endpoint devices: 512
Power consumption: 13.5 W
The 6Gb SAS Host Bus Adapter has the following key features:
Connection to supported internal and external tape drives
Connection to supported external storage controllers
Power management support
Support for SSP, SMP, STP and SATA protocols - flexible to optimize costs
Environmentally friendly due to low power consumption
LSI Fusion-MPT architecture drives more than 290,000 I/Os per second
End-to-End CRC with Advanced Error Reporting
T-10 Protection Model for early detection of and recovery from data corruption
Spread Spectrum Clocking for EMI reductions
6Gb SAS Host Bus Adapter 2
Server support
The 6Gb SAS Host Bus Adapter is supported in servers as listed in the following tables.
Support for System x and dense servers with Xeon E5/E7 v4 and E3 v5 processors
Table 1. Support for System x and dense servers with Xeon E5/E7 v4 and E3 v5 processors
Part number Description
46M0907 6Gb SAS HBA N N N N N N N
Support for servers with Intel Xeon v3 processors
Table 2. Support for servers with Intel Xeon v3 processors
Part number Description
46M0907 6Gb SAS HBA Y N N N N N N
x3250 M6 (3943)
x3250 M6 (3633)
x3550 M5 (8869)
x3650 M5 (8871)
x3850 X6/x3950 X6 (6241, E7 v4)
nx360 M5 (5465, E5-2600 v4)
sd350 (5493)
x3100 M5 (5457)
x3250 M5 (5458)
x3500 M5 (5464)
x3550 M5 (5463)
x3650 M5 (5462)
x3850 X6/x3950 X6 (6241, E7 v3)
nx360 M5 (5465)
6Gb SAS Host Bus Adapter 3
Support for servers with Intel Xeon v2 processors
Table 3. Support for servers with Intel Xeon v2 processors
Part number Description
46M0907 6Gb SAS HBA Y Y Y Y Y N N N N N N Y N
Support for servers with Intel Xeon v1 processors
Table 4. Support for servers with Intel Xeon v1 processors
Part number Description
46M0907 6Gb SAS HBA Y Y Y Y Y Y Y Y Y Y Y Y
See the ServerProven Web site for the latest information about the adapters supported by each System x server type: http://www.lenovo.com/us/en/serverproven/xseries/controllers/matrix.shtml
x3500 M4 (7383, E5-2600 v2)
x3530 M4 (7160, E5-2400 v2)
x3550 M4 (7914, E5-2600 v2)
x3630 M4 (7158, E5-2400 v2)
x3650 M4 (7915, E5-2600 v2)
x3650 M4 BD (5466)
x3650 M4 HD (5460)
x3750 M4 (8752)
x3750 M4 (8753)
x3850 X6/x3950 X6 (3837)
x3850 X6/x3950 X6 (6241, E7 v2)
dx360 M4 (E5-2600 v2)
nx360 M4 (5455)
x3100 M4 (2582)
x3250 M4 (2583)
x3300 M4 (7382)
x3500 M4 (7383, E5-2600)
x3530 M4 (7160, E5-2400)
x3550 M4 (7914, E5-2600)
x3630 M4 (7158, E5-2400)
x3650 M4 (7915, E5-2600)
x3690 X5 (7147)
x3750 M4 (8722)
x3850 X5 (7143)
dx360 M4 (7912, E5-2600)
6Gb SAS Host Bus Adapter 4
Internal tape support
The 6Gb SAS Host Bus Adapter supports connectivity to the internal tape drives listed in the following table.
Table 5. Internal tape drives
Part number Description
43W8478 Half High LTO Gen 3 SAS Tape Drive
44E8895 Half High LTO Gen 4 SAS Tape Drive
49Y9898 Half-High LTO Generation 5 SAS Tape Drive
00D8924 Half High LTO Ultrium Gen 6 Internal SAS Tape Drive
43W8480 DDS Gen 5 SATA Tape Drive
Internal tape drives are connected to the 6Gb SAS HBA using the internal SAS or SATA cable supplied with the tape drive.
Note: The adapter does not support internal disk drives.
6Gb SAS Host Bus Adapter 5
External storage system support
The adapter supports connectivity to the following 6 Gbps SAS external storage systems:
Table 6. External storage systems
Part number Description
IBM Storwize for Lenovo (mini-SAS HD interface)
6096CU2 IBM Storwize V3500 3.5-inch Dual Control Storage Controller Unit
6096CU3 IBM Storwize V3500 2.5-inch Dual Control Storage Controller Unit
6099L2C IBM Storwize V3700 3.5-inch Storage Controller Unit
6099S2C IBM Storwize V3700 2.5-inch Storage Controller Unit
6099T2C IBM Storwize V3700 2.5-inch DC Storage Controller Unit
6194L2C IBM Storwize V5000 LFF Control Enclosure
6194S2C IBM Storwize V5000 SFF Control Enclosure
The cables needed to connect the adapter (mini-SAS connector) to IBM Storwize units (mini-SAS HD connector) are listed in the following table.
Table 7. SAS cables for IBM Storwize connectivity
Part number Description
SAS cables for IBM Storwize (mini-SAS HD to mini-SAS)
00MJ162 0.6m SAS Cable (mSAS HD to mSAS)
00MJ163 1.5m SAS Cable (mSAS HD to mSAS)
00MJ166 3m SAS Cable (mSAS HD to mSAS)
For more information about IBM Storage products, see the list of Lenovo Press Product Guides listed in the following web page:
https://lenovopress.com/storage/san/ibm
For a detailed listing of supported end-to-end storage configurations, see the System Storage Interoperation Center (SSIC) website:
http://ibm.com/systems/support/storage/ssic
6Gb SAS Host Bus Adapter 6
External tape support
The adapter can be used for connectivity to the external tape backup units listed in the following table.
Table 8. External tape backup units
Part number Description
External tape enclosures (mini-SAS interface)
61901UX IBM Multimedia Backup Enclosure
Backup drives for IBM Multimedia Backup Enclosure (mini-SAS interface)
00NV402 6190 HH LTO5 SAS Tape Drive
00NV404 6190 HH LTO6 SAS Tape Drive
Tape backup units (mini-SAS interface)
6160S5E IBM TS2250 Tape Drive Model H5S
6160S6E IBM TS2260 Tape Drive Model H6S
6160S6X IBM TS2360 Tape Drive Model S63
6171S4R IBM TS2900 Tape Autoloader w/LT04 HH SAS Drive
6171S5R IBM TS2900 Tape Autoloader w/LT05 HH SAS Drive
6171S6R IBM TS2900 Tape Autoloader w/LT06 HH SAS Drive
Tape libraries
61732UL IBM TS3100 Tape Library Model L2U (Driveless)
61734UL IBM TS3200 Tape Library Model L4U (Driveless)
SAS tape drive options for TS3100/TS3200 Tape Libraries (mini-SAS interface)
00NA121 6173 LTO Ultrium 4 SAS Drive Sled
00NA105 6173 LTO Ultrium 4 Half High SAS DriveV2 Sled
00NA109 6173 LTO Ultrium 5 SAS Drive Sled
00NA111 6173 LTO Ultrium 5 Half High SAS Drive Sled
00NA117 6173 LTO Ultrium 6 Half High SAS Drive Sled
The cables needed to connect the adapter (mini-SAS connector) to external tape units (mini-SAS connector) are listed in the following table.
Table 9. SAS cables for tape drive connectivity (mini-SAS)
Part number Description
SAS cables (mini-SAS to mini-SAS)
39R6531 3m SAS Cable
39R6529 1m SAS Cable
For more information, see the list of Lenovo Press Product Guides in the Backup units category:
https://lenovopress.com/servers/options/backup
For a detailed listing of supported end-to-end storage configurations, see the System Storage Interoperation Center (SSIC) website:
http://ibm.com/systems/support/storage/ssic
6Gb SAS Host Bus Adapter 7
Operating system support
The adapter supports the following operating systems:
Microsoft Windows Server 2008 Foundation Microsoft Windows Server 2008 R2 Microsoft Windows Server 2008, Datacenter x64 Edition Microsoft Windows Server 2008, Datacenter x86 Edition Microsoft Windows Server 2008, Enterprise x64 Edition Microsoft Windows Server 2008, Enterprise x86 Edition Microsoft Windows Server 2008, Standard x64 Edition Microsoft Windows Server 2008, Standard x86 Edition Microsoft Windows Server 2008, Web x64 Edition Microsoft Windows Server 2008, Web x86 Edition Microsoft Windows Server 2012 Microsoft Windows Server 2012 R2 Red Hat Enterprise Linux 5 Server Edition Red Hat Enterprise Linux 5 Server with Xen x64 Edition Red Hat Enterprise Linux 5 Server x64 Edition Red Hat Enterprise Linux 6 Server Edition Red Hat Enterprise Linux 6 Server x64 Edition SUSE LINUX Enterprise Server 10 for AMD64/EM64T SUSE LINUX Enterprise Server 10 for x86 SUSE LINUX Enterprise Server 10 with Xen for AMD64/EM64T SUSE LINUX Enterprise Server 11 for AMD64/EM64T SUSE LINUX Enterprise Server 11 for x86 SUSE LINUX Enterprise Server 11 with Xen for AMD64/EM64T VMware ESX 4.1 VMware ESXi 4.1 VMware vSphere 5.0 (ESXi) VMware vSphere 5.1 (ESXi) VMware vSphere 5.5 (ESXi)
See the ServerProven Web site for the latest information about the specific versions and service packs supported: http://www.lenovo.com/us/en/serverproven/xseries/controllers/matrix.shtml. Click the check mark that is associated with the System x server in question to see details about the operating system support.
Operating environment
The 6Gb SAS Host Bus Adapter is supported in the following environment:
Temperature:
10 to 35 °C (50 to 95 °F) at an altitude of 0 to 914 m (0 to 3,000 ft)
10 to 32 °C (50 to 90 °F) at an altitude of 0 to 2,100 m (0 to 7,000 ft)
Humidity: 20% to 80%, non-condensing
Maximum altitude: 2,100 m (7,000 ft)
Warranty
One-year limited warranty. When installed in a supported System x® server, this adapter assumes the server's base warranty and any warranty upgrade.
6Gb SAS Host Bus Adapter 8
Related publications
For more information refer to the following documents:
US Announcement Letter
http://ibm.com/common/ssi/cgi-bin/ssialias?infotype=dd&subtype=ca&&htmlfid=897/ENUS110-013
6Gb SAS Host Bus Adapter Installation and User's Guide
http://ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-5084780
System x Configuration and Options Guide:
http://www.ibm.com/systems/xbc/cog/
IBM System Storage Interoperation Center (SSIC)
http://www.ibm.com/systems/support/storage/config/ssic
Related product families
Product families related to this document are the following:
Host Bus Adapters
6Gb SAS Host Bus Adapter 9
Notices
Lenovo may not offer the products, services, or features discussed in this document in all countries. Consult your local Lenovo representative for information on the products and services currently available in your area. Any reference to a Lenovo product, program, or service is not intended to state or imply that only that Lenovo product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any Lenovo intellectual property right may be used instead. However, it is the user's responsibility to evaluate and verify the operation of any other product, program, or service. Lenovo may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing, to:
Lenovo (United States), Inc. 1009 Think Place - Building One Morrisville, NC 27560 U.S.A. Attention: Lenovo Director of Licensing
LENOVO PROVIDES THIS PUBLICATION ”AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some jurisdictions do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you.
This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. Lenovo may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice.
The products described in this document are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. The information contained in this document does not affect or change Lenovo product specifications or warranties. Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third parties. All information contained in this document was obtained in specific environments and is presented as an illustration. The result obtained in other operating environments may vary. Lenovo may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you.
Any references in this publication to non-Lenovo Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this Lenovo product, and use of those Web sites is at your own risk. Any performance data contained herein was determined in a controlled environment. Therefore, the result obtained in other operating environments may vary significantly. Some measurements may have been made on development-level systems and there is no guarantee that these measurements will be the same on generally available systems. Furthermore, some measurements may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment.
© Copyright Lenovo 2018. All rights reserved.
This document, TIPS0776, was created or updated on February 10, 2018.
Send us your comments in one of the following ways:
Use the online Contact us review form found at:
http://lenovopress.com/TIPS0776
Send your comments in an e-mail to:
comments@lenovopress.com
This document is available online at http://lenovopress.com/TIPS0776.
6Gb SAS Host Bus Adapter 10
Trademarks
Lenovo, the Lenovo logo, and For Those Who Do are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at
http://www3.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both: Lenovo® ServerProven® System x® X5
The following terms are trademarks of other companies:
Intel® and Xeon® are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.
Linux® is a trademark of Linus Torvalds in the United States, other countries, or both.
Microsoft®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.
6Gb SAS Host Bus Adapter 11
Loading...