Lenovo 00WC035 User Manual

Lenovo Storage S3200
Product Guide
The Lenovo® Storage S3200 (shown in the following figure) is a versatile storage system that is designed to provide simplicity, speed, scalability, security, and high availability for small to large businesses. The S3200 SAN array delivers enterprise-class storage management technology in a cost-effective solution with a wide choice of host connectivity options, flexible drive configurations, and enhanced data management features.
Figure 1. Lenovo Storage S3200
The S3200 offers the flexible choice of storage connectivity protocols: 6/12 Gb SAS, 1 Gb or 10 Gb iSCSI, and 4/8/16 Gb Fibre Channel (FC). Converged Network Controller (CNC) design of the S3200 makes the selection of iSCSI or FC host connectivity (or both FC and iSCSI) as simple as attaching corresponding transceivers or 10 GbE SFP+ Direct-Attach Copper (DAC) cables to the SFP/SFP+ ports on the RAID controller.
The S3200 supports up to 192 drives with up to seven external expansion enclosures, and it offers flexible drive configurations with the choice of 2.5-inch and 3.5-inch drive form factors, 10K or 15K rpm SAS and
7.2K rpm NL SAS hard disk drives (HDDs) and self-encrypting drives (SEDs), and SAS solid-state drives (SSDs). The S3200 can be scaled up to 960 TB of raw storage capacity.
Did you know?
The S3200 supports Intelligent Real-time Tiering capabilities that help optimize system performance, reduce costs, and simplify management. The base software includes the ability to move data dynamically between SAS HDDs that are optimized for cost per IOPS and NL SAS HDDs that are optimized for cost per GB. With the optional software license, the S3200 supports hybrid tiering across HDDs and SSDs.
With flexibility of the Converged Network Controllers, the S3200 supports hybrid iSCSI and Fibre Channel connectivity at the same time.
The S3200 supports battery-free cache protection which reduces maintenance costs and provides permanent backup of unwritten cache data in case of power failure.
Click here to check for updates
Lenovo Storage S3200 1
Key features
Key features and benefits provided by the S3200 storage system include:
Versatile, scalable storage with a single controller, or dual active/active controller configurations for high availability and performance.
Flexible host connectivity to match diverse client needs with support for 6/12 Gb SAS (SAS controller) or 1/10 Gb iSCSI or 4/8/16 Gb FC connectivity (FC and iSCSI controller) or both iSCSI and FC at the same time.
6 Gb SAS drive-side connectivity with support for 12x 3.5-inch large form factor (LFF) or 24x 2.5­inch small form factor (SFF) drives in the controller enclosure; scalable up to 96 LFF drives per system with the attachment of Lenovo Storage E1012 expansion enclosure (12x LFF drives each) or up to 192 SFF drives per system with the attachment of Lenovo Storage E1024 expansion enclosure (24x SFF drives each) to satisfy growing needs for storage capacity and performance.
Flexibility in storing data on high performance SAS SSDs, performance-optimized enterprise SAS HDDs, or capacity-optimized enterprise NL SAS HDDs; mixing and matching drive types and form factors within a single system to perfectly meet performance and capacity requirements for various workloads.
Support for self-encrypting drives to allow clients to secure their sensitive data and to comply with various security regulations when required.
Rich set of standard functions available at no additional cost, including virtualized storage pools, snapshots, thin provisioning, rapid rebuild, real-time HDD tiering, and SSD read cache.
Optional licensed functions, including higher number of snapshots for more scalability, real-time SSD tiering for boosting IOPS performance, and asynchronous replication for 24x7 data protection and disaster recovery.
Intuitive, web-based GUI for easy system setup and management.
Designed to comply with NEBS and MIL-STD requirements.
Designed for 99.999% availability.
The S3200 is designed to support the complete range of data storage requirements, from highly utilized applications to high-capacity, low usage applications.
The following 3.5-inch drives are supported:
High performance solid-state drives (10 drive writes per day [DWD]): 400 GB Performance-optimized, enterprise class disk drives: 600 GB and 900 GB 10K rpm High-capacity, archival-class nearline disk drives: 2 TB, 4 TB, 6 TB, 8 TB, and 10 TB 7.2K rpm
The following 2.5-inch drives are supported:
High performance solid-state drives (3 DWD and 10 DWD): 400 GB, 800 GB, and 1.6 TB
High performance self-encrypting solid-state drives (10 DWD): 400 GB and 800 GB
Capacity-optimized solid-state drives (1 DWD): 3.84 TB
Performance-optimized, enterprise class disk drives
300 GB and 600 GB 15K rpm 600 GB, 900 GB, 1.2 TB, and 1.8 TB 10K rpm
High-capacity, archival-class nearline disk drives: 1 TB and 2 TB 7.2K rpm
Additional drives and expansion units are designed to be dynamically added with virtually no downtime, helping to quickly and seamlessly respond to ever-growing capacity demands.
Lenovo Storage S3200 2
The S3200 storage system is designed to offer high levels of system and data availability with the following technologies:
Dual-active RAID controllers with low latency cache mirroring
Dual-port drives (both HDDs and SSDs) with automatic drive failure detection and rapid RAID rebuild with global hot spares
Redundant hardware, including host ports, controller modules, and power supplies and fans
Hot-swappable and customer replaceable components, including controllers, power supplies with fans, and drives
Automated path failover support for the data path between the host and the drives with multipathing software
Non-disruptive controller firmware upgrades for dual controller configurations with multipathing
The following functions are included with every S3200:
Intelligent Real-time Tiering for HDDs : Storage tiering helps optimize storage use with intelligent data placement to improve system performance, reduce costs, and simplify management. The S3200 automatically and dynamically moves frequently accessed data to higher performing HDDs in the system without manually creating and managing storage tier policies.
RAID levels 0, 1, 5, 6, and 10 : Provide the flexibility to choose the level of data protection required.
Virtualized storage pools: Enables rapid, flexible storage provisioning and simple configuration
changes. Stored data is distributed across all drive groups in the pool (wide striping) which helps improve performance, lower latency, and achieve higher volume capacities. When a new drive group is added to the pool, the system performs automatic rebalancing to utilize all drives in the pool for better performance.
Thin provisioning: Optimizes efficiency by allocating drive storage space in a flexible manner among multiple applications, based on the minimum space required by each application at any given time. With thin provisioning, applications consume only the space they are actually using, not the total space that has been allocated to them, which allows clients to purchase storage they need today and add more as application requirements grow.
SSD Read Cache: An extension of the controller's cache to improve performance of read-centric workloads
Rapid RAID Rebuild : Helps significantly decrease the time to recover lost data by only rebuilding the stripe where the corruption occurred, not the empty space or other stripes
Snapshots: Enables creation of copies of data for backup, parallel processing, testing, and development, and have the copies available almost immediately. Base software supports up to 128 snapshot targets per system.
The S3200 storage capabilities can be expanded with optional licensed functions. Each optional S3200 function is licensed on a per-system basis and covers both controller enclosure and all attached expansion units.
Optional licensed functions include:
Intelligent Real-time Tiering for SSDs: The SSD tiering upgrade option allows the use of SSDs as read and write storage. Also, this option makes it easy and economical to deploy hybrid storage by dynamically moving frequently accessed data to SSDs in the system, resulting in flash drive performance without manually creating and managing storage tier policies.
Snapshots upgrade: The snapshot upgrade options increase the supported number of snapshot targets to 512 or 1,024 per system.
Lenovo Storage S3200 3
Asynchronous Replication: The asynchronous replication feature provides storage system-based data replication between two peers by using asynchronous data transfers over IP communication links.
The replication is done at predetermined intervals (Now, 1 hour, 12 hour, 24 hour) and does not require high-bandwidth network connection. For ultimate flexibility, S3200 asynchronous replication interoperates with Lenovo Storage S2200.
The asynchronous replication option must be acquired (or licensed) for both primary (local) and secondary (remote) systems.
The S3200 supports the following management interfaces:
Web-based graphical user interface (GUI) via HTTP that requires only a supported browser (Microsoft Internet Explorer, Google Chrome, or Mozilla Firefox), so there is no need for a separate console or plug-in
Command line interface (CLI) via Telnet or SSH or through Direct Connect USB
HTTP scripting interface with XML encoding
SNMP and e-mail notifications
Components and connectors
The following figure shows the front of the S3200 SFF chassis and E1024 drive expansion enclosure.
Figure 2. Front view of the S3200 SFF chassis and E1024 drive enclosure
The following figure shows the front of the S3200 LFF chassis and E1012 drive expansion enclosure.
Figure 3. Front view of the S3200 LFF chassis and E1012 drive enclosure
Lenovo Storage S3200 4
The following figure shows the rear of the S3200 with FC or iSCSI host interfaces with dual RAID controllers. Single RAID controller configurations are also supported.
Figure 4. Rear view of the S3200 with FC or iSCSI host interfaces
The following figure shows the rear of the S3200 with SAS host interfaces with dual RAID controllers. Single RAID controller configurations are also supported.
Figure 5. Rear view of the S3200 with SAS host interfaces
Lenovo Storage S3200 5
The following figure shows the rear of the E1012 and E1024 drive enclosures with dual I/O expansion modules. Single I/O module configurations are also supported with the single-controller S3200.
Figure 6. Rear view of the E1012 and E1024 drive enclosures
Note: The RAID controllers (shown in Figure 4 and Figure 5) and expansion modules (shown in Figure 6) have additional service ports with a specialized connector, and these ports are reserved for use by a Lenovo service technician.
System specifications
The following table lists the S3200 storage system technical specifications.
Table 1. System specifications
Components Specification
Form factor S3200 controller enclosure: 2U rack mount
E1012 or E1024 drive expansion enclosure: 2U rack mount
RAID controller configuration
Two types of controllers:
S3200 SAS controller S3200 FC and iSCSI controller
Single or dual RAID controller configurations supported. Single controller systems can be upgraded to dual controller non-disruptively. Both controllers in the system must be the same.
RAID levels RAID 0, 1, 5, 6, and 10
RAID controller cache
6 GB per controller. Battery-free cache protection with flash memory and supercapacitors. Low latency cache mirroring protection for dual controller configurations.
Drive bays Up to 192 SFF drive bays per system:
24 SFF drive bays in the S3200 controller enclosure 24 SFF drive bays in the E1024 drive expansion enclosure; up to 7x E1024 enclosures
Up to 96 LFF drive bays per system:
12 LFF drive bays in the S3200 controller enclosure 12 LFF drive bays in the E1012 drive expansion enclosure; up to 7x E1012 enclosures
Intermix of SFF and LFF enclosures is supported.
Drive technologies
SAS and NL SAS HDDs and SEDs; eMLC SAS SSDs. Intermix of HDDs and SSDs is supported. Intermix of SEDs with HDDs or SSDs is not supported.
Lenovo Storage S3200 6
Drive connectivity
Dual-ported 6 Gb SAS drive attachment infrastructure.
Controller enclosure with one or two RAID controllers (ports per one controller):
24x 6 Gb SAS internal drive ports (SFF chassis) 12x 6 Gb SAS internal drive ports (LFF chassis) 1x 6 Gb SAS x4 (Mini-SAS SFF-8088) expansion port for the attachment of the external drive enclosures
Drive expansion enclosure with one or two expansion modules (ports per one module):
24x 6 Gb SAS internal drive ports (SFF chassis) 12x 6 Gb SAS internal drive ports (LFF chassis) 2x 6 Gb SAS x4 (Mini-SAS SFF-8088) expansion ports (IN and OUT) for the daisy chained attachment of the external drive enclosures
Drives SFF drives:
400 GB, 800 GB, and 1.6 TB SAS SSDs (3 DWD and 10 DWD) 400 GB and 800 GB SAS SED SSDs (10 DWD)
3.84 TB SAS SSDs (1 DWD) 300 GB and 600 GB 15K rpm SAS HDDs 600 GB, 900 GB, 1.2 TB, and 1.8 TB 10K rpm SAS HDDs 1 TB and 2 TB 7.2K rpm NL SAS HDDs
LFF drives:
400 GB SAS SSDs (10 DWD) 600 GB and 900 GB 10K rpm SAS HDDs 2 TB, 4 TB, 6 TB, 8 TB, and 10 TB 7.2K rpm NL SAS HDDs
Storage capacity Up to 960 TB (96x 10 TB NL SAS HDDs)
Host connectivity S3200 SAS controller: 4x 6/12 Gb SAS host ports (Mini-SAS HD, SFF-8644)
S3200 FC and iSCSI controller: 4x SFP/SFP+ host ports with two built-in dual-port CNCs (each port on the same CNC must have the same connectivity type, different CNCs might have different connectivity types) CNC host port options (per each CNC on the RAID controller):
2x 1 Gb iSCSI SFP (1 Gb speed, UTP, RJ-45) 2x 10 Gb iSCSI SFP+ (1/10 Gb speeds, SW fiber optics, LC) 2x 8 Gb FC SFP+ (4/8 Gb speeds, SW fiber optics, LC) 2x 16 Gb FC SFP+ (4/8/16 Gb speeds, SW fiber optics, LC) 2x 10 Gb iSCSI SFP+ DAC cables
Host operating systems
Microsoft Windows Server 2012 and 2012 R2; Red Hat Enterprise Linux (RHEL) 6 and 7; SUSE Linux Enterprise Server (SLES) 10, 11, and 12; VMware vSphere 5.5 and 6.0.
Standard software features
Intelligent Real-time Tiering for HDDs, Virtualized Storage Pools, Thin Provisioning, SSD Read Cache, Rapid RAID Rebuild, Snapshots - up to 128 targets.
Optional software features
Intelligent Real-time Tiering for SSDs, Snapshots - up to 1,024 targets, Asynchronous Replication.
Performance Dual controller configuration:
Up to 120,000 random read IOPS (4 KB blocks) Up to 6.4 GBps sequential read throughput (512 KB blocks) Up to 5.3 GBps sequential write throughput (512 KB blocks)
Components Specification
Lenovo Storage S3200 7
Configuration maximums
Per system:
Maximum number of virtual storage pools: 2 (1 per controller) Maximum number of logical volumes (total/mapped): 2,048/1,024 Maximum logical volume size: 128 TB Maximum number of drives in a drive group: 16 Maximum number of drive groups: 32 Maximum global spares: 16 Maximum number of initiators: 8,192 (1,024 per port) Maximum number of hosts in a host group: 256 Maximum number of host groups: 32 Maximum number of initiators per host: 128 Maximum number of snapshots: 1,024 (requires an optional license) Maximum number of replication peers: 1 (requires an optional license) Maximum number of replication volumes: 32 (requires an optional license)
Cooling Redundant cooling with two fans that are built into power supplies.
Power supply Two redundant hot-swap 595 W AC power supplies.
Hot-swap parts RAID controllers, expansion modules, SFP/SFP+ transceivers, drives, power supplies/fans.
Management interfaces
Web-based graphical user interface (GUI); Telnet, SSH, or Direct Connect USB command-line interface (CLI); HTTP scripting with XML encoding; SNMP and e-mail notifications
Security features Secure Socket Layer (SSL), Secure Shell (SSH), self-encrypting drives (SEDs)
Warranty Three-year customer-replaceable unit, parts only limited warranty with 9x5 next business day.
Service and support
Optional warranty service upgrades are available through Lenovo: on-site support, 24x7 coverage, 4-hour response time, 1-year or 2-year warranty extensions, Hard Drive Retention.
Dimensions LFF chassis: Height: 87 mm (3.4 in), width: 447 mm (17.6 in), depth: 523 mm (20.6 in)
SFF chassis: Height: 89 mm (3.5 in), width: 447 mm (17.6 in), depth: 519 mm (20.5 in)
Weight S3200 LFF: Minimum: 18.4 kg (40.6 lb); Maximum: 28.2 kg (62.2 lb)
S3200 SFF: Minimum: 18.5 kg (40.8 lb); Maximum: 25.0 kg (55.2 lb) E1012: Minimum: 16.8 kg (37.0 lb); Maximum: 26.6 kg (58.6 lb) E1024: Minimum: 16.9 kg (37.2 lb); Maximum: 23.4 kg (51.6 lb)
Components Specification
Controller enclosures
The following table lists the relationship models of the S3200.
Table 2. Part numbers for ordering S3200 relationship models
Description Part number
LFF models
Lenovo Storage S3200 LFF Chassis SAS Single Controller, Rack Kit, 9x5NBD 64113B1*
Lenovo Storage S3200 LFF Chassis SAS Dual Controller, Rack Kit, 9x5NBD 64113B2
Lenovo Storage S3200 LFF Chassis FC/iSCSI Single Controller, Rack Kit, 9x5NBD 64116B1*
Lenovo Storage S3200 LFF Chassis FC/iSCSI Dual Controller, Rack Kit, 9x5NBD 64116B2
SFF models
Lenovo Storage S3200 SFF Chassis SAS Single Controller, Rack Kit, 9x5NBD 64113B3*
Lenovo Storage S3200 SFF Chassis SAS Dual Controller, Rack Kit, 9x5NBD 64113B4
Lenovo Storage S3200 SFF Chassis FC/iSCSI Single Controller, Rack Kit, 9x5NBD 64116B3*
Lenovo Storage S3200 SFF Chassis FC/iSCSI Dual Controller, Rack Kit, 9x5NBD 64116B4
* Not available for ordering in North America (United States and Canada).
Lenovo Storage S3200 8
The part number for the S3200 includes the following items:
One S3200 chassis with two power supplies and fans:
With one or two SAS RAID controllers installed With one or two FC and iSCSI RAID controllers installed
Two 4.3 m, 10 A/100 - 250 V, C13 to IEC 320-C14 Rack Power Cables Lenovo Storage SAN Rack Mount Kit: Rails 25-inch to 36-inch Lenovo 1.5 m USB console cable (USB to-Mini-USB) Getting Started Guide Warranty Flyer Important Notices Flyer Documentation CD-ROM
The following table lists the TopSeller models of the S3200.
Table 3. Part numbers for ordering S3200 TopSeller models
Description Part number
LFF models
S3200 LFF Dual FC/iSCSI Controller/4x 8Gb FC/Rack Kit/Base Warranty 6411E24*
SFF models
S3200 SFF Dual SAS Controller/4x 400GB SSDs/10x 600GB 10K HDDs/Rack Kit/Base Warranty 6411E25*
S3200 SFF Dual FC/iSCSI Controller/4x 8Gb FC/Rack Kit/Base Warranty 6411E29*
S3200 SFF Dual FC/iSCSI Controller/4x 8Gb FC/Rack Kit/Base Warranty 6411E37*
S3200 SFF Dual FC/iSCSI Controller/4x 8Gb FC/5x 300GB 15K HDDs/Rack Kit/Base Warranty 6411E26*
S3200 SFF Dual FC/iSCSI Controller/4x 8Gb FC/5x 600GB 10K HDDs/Rack Kit/Base Warranty 6411E27*
S3200 SFF Dual FC/iSCSI Controller/2x 8Gb FC/5x 900GB 10K HDDs/Rack Kit/Base Warranty 6411E28*
S3200 SFF Dual FC/iSCSI Controller/4x 8Gb FC/6x 600GB 10K HDDs/Rack Kit/Base Warranty 6411E36*
S3200 SFF Dual FC/iSCSI Controller/4x 8Gb FC/8x 600GB 10K HDDs/Rack Kit/Base Warranty 6411E33*
S3200 SFF Dual FC/iSCSI Controller/4x 8Gb FC/8x 900GB 10K HDDs/Rack Kit/Base Warranty 6411E31*
S3200 SFF Dual FC/iSCSI Controller/4x 8Gb FC/8x 900GB 10K HDDs/4x 400GB SSDs/Tiering 6411E2D
S3200 SFF Dual FC/iSCSI Controller/4x 16Gb FC/12x 600GB 10K HDDs/Rack Kit/Base Warranty 6411E35*
S3200 SFF Dual FC/iSCSI Controller/4x 16Gb FC/10x 600GB 10K HDDs/4x 400GB SSDs/Tiering 6411E34
* Not available for ordering in North America (United States and Canada).
Note: S3200 TopSeller models are country-specific; that is, not all listed models might be available for ordering in a particular country or area. Ask a Lenovo representative for specifics.
The S3200 TopSeller model part numbers include the following items:
One S3200 chassis with two power supplies and fans:
With two SAS RAID controllers installed With two FC/iSCSI RAID controllers installed (with 2x or 4x SFPs; see Table 3 for details) Without drives, or with HDDs, or with HDDs and SSDs (see Table 3 for details) Tiering license (part numbers 6411E2D and 6411E34 only)
Two 4.3 m, 10 A/100 - 250 V, C13 to IEC 320-C14 Rack Power Cables Lenovo Storage SAN Rack Mount Kit: Rails 25-inch to 36-inch Lenovo 1.5 m USB console cable (USB to Mini-USB) Getting Started Guide Warranty Flyer Important Notices Flyer Documentation CD-ROM
Lenovo Storage S3200 9