Lennox International Inc. 10GCS, 12GCS User Manual

PRODUCT LITERATURE
¤
1998 LennoxIndustries Inc.
Dallas, Texas,USA
Armstrong #38152A054 503,969M
10GCS
£
*&6 *&6
6(5,(6
*$6  (/(&75,&
3$&.$*('
81,76
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
,I WKH LQIRUPDWLRQ LQ WKLV PDQXDO LV QRW IROORZHG H[DFWO\ D ILUH RU H[SORVLRQ PD\ UHVXOW FDXVLQJ SURSHUW\ GDPDJH SHUVRQDO LQMXU\ RU GHDWK
Do notstoreoruse gasoline orother flammable vapors and liquids in the vicinity of this or any other ap­pliance.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
12GCS
:$51,1*
WHAT TO DO IF YOU SMELL GAS:
- Do not try to light any appliance.
- Extinguish any open flames.
- Do not touch any electrical switch; do not
use any phone in your building.
- Immediately call your gas supplier from a neighbor’sphone. Followthe gass upplier’s instructions.
- If you cannot reach your gas supplier, call the fire department.
3DJH
Parts Arrangement
CONDENSER FAN
CONDENSER COIL
BLOWER
BLOWER MOTOR
COMPRESSOR
HEAT EXCHANGER
ASSEMBLY
PRESSURE SWITCH
GAS
MANIFOLD
GAS V ALVE
BURNER BOX
COMBUSTION
AIR BLOWER
CONTROL BOX SECTION
FIGURE 1
Any additions, changes,or conversions required in order for the appliance to satisfactorilymeet the ap-
plication needs must be made by a Lennox service technician using factory specified and approved parts.
WARNING
Product contains fiberglass wool. Disturbing the insulation in this product during
installation, maintenance, or repair will expose you to fiberglass wool dust. Breathing this may cause
Anyadditions, changes,or conversionsrequired inor­der for the applicnace to satisfactorily meet the ap­plication needs must be made by a Lennox service technicain usingfactory specifiedand approvedparts.
IMPORTANT
lung cancer. (Fiberglass wool is known to the State of California to cause cancer.)
Fiberglass wool may also cause respiratory, skin, and eye irritation.
To reduce exposure to this substance or for further information, consult material safety data sheets availablefromaddressshown below,or contactyour supervisor.
Lennox Industries Inc. P.O. Box 799900
Dallas, TX 75379-9900
Important Directions
Keep the area clean and free of combustible material, gaso­line, andother flammable vapors and liqu ids. Theflow of com­bustion and ventilation air must not be obstructed from enter­ing the furnace or condenser coil. Do not permit overhanding structures or shrubs to obstruct conden ser fan discharge, combustion air inlet or vent outlet.