HEARTH PRODUCTS
KITS AND ACCESSORIES
P/N 506033-36
Rev. NC, 11/2009
COUNTRY COLLECTION™ WOOD FIREPLACE INSERTS
INSTALLATION INSTRUCTIONS FOR INSTALLING BLOWER
KITS FOR USE WITH COUNTRY COLLECTION™ MODELS E260, C260, C310,
C160, CA160, C210 AND CA210 WOOD FIREPLACE INSERTS
KIT CONTENTS
1 ea. Blower Assembly
1 ea. Instruction Sheet
TOOLS NEEDED
5/32 Allen Wrench Or T Handle Wrench
9/16” Socket Wrench
9/16” Open End Wrench
5/16” Open End Wrench
Large Flat Head Screwdriver
GENERAL INFORMATION
This optional blower kit can be installed to improve hot air distribution
throughout the room.
variable speed control (rheostat) and an snap switch which will provide
automatic thermal activation of the blower, when desired (see Blower
Operation on Page 4).
If you encounter any problems, need clarification of these instructions or
are not qualified to properly install this kit, contact your local distributor
or dealer.
Read this instruction sheet in its entirety before beginning the installation.
ALL WARNINGS AND PRECAUTIONS IN THE INSTALLATION AND
OPERATION MANUAL PROVIDED WITH THE APPLIANCE APPLY TO
THESE INSTRUCTIONS.
BLOWER KITS
The room air circulation blower kit comes with a
Figure 1 - Kit Contents
BLOWER KITS FOR MODELS C160, CA160, C210 AND CA210
Cat. No. Model Description
H7907
H7908
H7909
H7910
H7911
H7912
H7913
H7914
H7915
H7916
WSINS-BLWR-B-SS Blower Insert Black
WSINS-BLWR-G-SS Blower Insert Gold
WSINS-BLWR-N-SS Blower Insert Nickle
WSINS-BLWR-BN-SS Blower Insert Brushed Nickel
WSINS-BLWR-BG-SS Blower Insert Brushed Gold
BLOWER KITS FOR MODELS E260, C260, AND C310
WLINS-BLWR-B-SS Blower Insert Black
WLINS-BLWR-G-SS Blower Insert Gold
WLINS-BLWR-N-SS Blower Insert Nickle
WLINS-BLWR-BN-SS Blower Insert Brushed Nickle
WLINS-BLWR-BG-SS Blower Insert Brushed Gold
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
SHUT DOWN THE INSERT AND ALLOW IT TO COMPLETELY COOL
BEFORE PROCEEDING.
WARNINGS
The blower must be plugged directly into a properly
grounded three-prong receptacle, 120 VAC, 60 Hz, single
phase. Do not cut or remove the grounding prong from
this plug. Do not route power cord under or in front of
appliance.
Installation must be in accordance with National Electrical Code, ANSI/NFPA 70 - latest edition. In Canada,
the current CSA C22-1 Canadian Electrical Code - latest
edition.
DANGER: Disconnect power before servicing blower.
1

INSTALLATION INSTRUCTIONS
Install Blower Assembly
Step 1. Remove the contents from the blower kit.
Step 2. Place grommet with power cord into lower slot on desired side
of insert. See Figure 2.
Figure 2
Step 3. Loosen the two blower mounting bolts below ash lip on both
sides of front of insert, with 9/16” wrench. See Figure 3.
Blower Mounting Slot
Figure 4
Step 5. Insert blower under the ash lip making sure that the slots in
the blower housing line up to the left side of bolts. Gently slide
blower housing from left to right over the loosened bolts until
you feel it hit a solid stop and the housing is centered under the
ash lip of the insert. See Figure 5.
Figure 3
Step 4. Notice the corresponding slots on the rear of blower cage. See
Figure 4.
Figure 5
Step 6. Visually inspect and confirm that the snap switch is flat against
the bottom side of the ash lip.
Step 7. After installing blower, If snap switch height adjustment is nec-
essary, remove blower, and with a 5/16” wrench, loosen snap
switch bracket nuts, and adjust up or down. When complete,
re-tighten bracket nuts and re-install blower.
Figure 6
2