INSTALLATION INSTRUCTIONS FOR CONVERTING FROM PROPANE GAS (LP) TO NATURAL GAS (NG). FOR USE WITH THE RAVELLE 42 DIRECT VENT GAS FIREPLACE
KIT CONTENTS (See Figure 1):
1 ea. Nova SIT NG Regulator Kit (A) 1 ea. #30 NG main burner orifice (42,000 BTU’s) (B) 1 ea. Instruction Sheet
TOOLS NEEDED (See Figure 2):
5/32” Allen Wrench Or T-Handle Wrench Torx Bit (T20 with 1/4” shank and center hole) 1/2” Open End Wrench 7/16” Open End Wrench
RAVELLE 42™ GAS CONVERSION INSTRUCTIONS LP TO NG
AVERTISSEMENT
Cet équipement de conversion sera installé par une agence qualifiée de service conformément aux instruc­tions du fabricant et toutes exigences et codes applica­bles de l'autorisés avoir la juridiction. Si l'information dans cette instruction n'est pas suivie exactement, un feu, explosion ou production de protoxyde de carbone peut résulter le dommages causer de propriété, perte ou blessure personnelle de vie. L'agence qualifiée de service est esponsable de l'installation propre de cet
Figure 1 - Kit Contents
B
équipment. L'installation n'est pas propre et compléte jusqu'à l'opération de l'appareil converti est chéque suivant les critères établis dans les instructions de propriétaire provisionnées avec l'équipement.
CAT. NO. 75095, MODEL RAVL42-CK-LP TO NG
A
Figure 2 - Tools Needed
Fig. 2
WARNING
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer's instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency performing this installation is responsible for the proper installation of this kit and assumes responsibility for this conversion. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturers instructions supplied with the kit.
IMPORTANT CANADA
The conversion shall be carried out in accordance with the requirements of the provincial authorities having jurisdiction and in accordance with the requirements of the CAN/CSA B149.1 Installation code.
IMPORTANT LE CANADA SEULEMENT
La conversion devra être effectuée conformément aux recommandations des autorités provinciales ayant juridiction et conformément aux exigences du code d'installation CAN/CSA B149.1 .
IMPORTANT
The burner orifices provided in this kit are only for use at elevations of 0 to 2,000 feet (610 M) in the USA and 0 to 4,500 feet (0-1372 M) in Canada. At higher elevations the BTU input must be de-rated by 4% for every 1,000 feet (305 M) to maintain the proper ratio of gas to air. If the installer must convert the unit to adjust for varying altitudes, a deration information sticker must be filled out by the installer and adhered to the appliance at the time of the conversion. Contact your local gas supplier for deration requirements for your area.
1
Page 2
READ ALL THE STEPS BEFORE STARTING THE CONVERSION. INSTALLER NOTICE: THESE INSTRUCTIONS MUST BE LEFT WITH THE APPLIANCE.
This kit contains components required to convert this appliance from using Propane Gas to using Natural Gas as the only fuel. All of these components must be replaced in order for the unit to operate safely on Natural Gas.
When installing gas components use pipe joint compound or Teflon tape on all pipe fittings before installing (ensure propane resistant compounds are used, do not use pipe joint compounds on flare fittings).
INSTALLATION INSTRUCTIONS
TURN OFF THE GAS SUPPLY TO THE APPLIANCE.
Step 1. Using a Torx T20 or flat screwdriver, remove the Nova SIT LP
Regulator (flame height control) by removing the 3 screws sur­rounding it (see Figure 3) . Be sure to also remove the LP regulator diaphragm (see Figure 3).
Step 2. Install the Nova SIT NG Regulator (included in this kit) using the
3 new screws provided as shown in Figure 3.
Step 7 To remove the burner, slide the burner off the orifice and out of
the air shutter by shifting the burner to the right.
Remove the allen screws on the right side of burner.
Burner
Shared Screw Hole
Figure 3
Regulator
Diaphragm
Fill out & affix label from regulator kit to valve
Remove the allen screw securing the front left corner of the burner.
Screws
Figure 4
Step 8 Remove the pilot shield by removing the two allen screws (see
Figure 5).
Step 9 Reinstall screws to secure pilot assembly for pilot orifice conver-
sion.
Pressure
Regulator
Remove These Components
Step 3 Remove the glass by releasing the two upper spring latches, and
lifting up and out of the lower latches.
Step 4 Remove the right side burner support by removing the four allen
screws (see Figure 4). Note: The right front corner of the burner
shares a screw with the burner support.
Step 5 Remove the allen screw securing the front left corner of the
burner.
Step 6 Move the air shutter control lever all the way to the right (see
Figure 9).
2
NOTE: DIAGRAMS AND ILLUSTRATIONS ARE NOT TO SCALE.
5/32” allen screws
Figure 5
Page 3
Step 10 Using a 7/16” open-end wrench, loosen pilot stem a quarter of a
turn to the left, counter-clockwise (see Figure 6).
7/16” Wrench
Pilot Hood
Pilot Stem
Figure 6
Step 11 Slide the pilot orifice into the NG position by pushing it toward the
opposite side of the pilot stem. The top side of the orifice slider should appear silver. The gas supply is now lined up with the NG pilot orifice (See Figure 7).
Step 12 Tighten the pilot stem by turning it back to the right, making sure
the orifice slider stays pushed into the NG position.
Step 13 IMPORTANT: REINSTALL PILOT SHIELD
1/2” End Wrench
Burner Orifice
Figure 8
Step 15 Install burner, and make sure air shutter is 1/8” open. After Step
14, with the appliance lit and fully warmed up, evaluate the burner flame appearance and re-adjust air shutter for proper flame ap­pearance, if necessary.
Slide the pilot orifice into the NG position (silver)
Figure 7
Step 14 Using a 1/2” open-end wrench, remove burner orifice (see Figure
8). Replace with #30 NG burner orifice using Teflon pipe sealant
or pipe sealing compound.
Air Venturi ­Adjust to 1/8” Gap
Air Shutter
Air Shutter Control Lever
Expanded View of Air Shutter Con­trol Lever
Open Close
Figure 9 - Air Shutter
NOTE: DIAGRAMS AND ILLUSTRATIONS ARE NOT TO SCALE.
3
Page 4
Step 16. Turn on gas supply and test for gas leaks using a gas leak test
solution (see Test Procedure on Page 22 of the Installation and Operation Manual).
Step 17. Using a manometer, test the inlet and manifold gas pressure per
instructions in the Installation and Operation Manual (Page 22) and as shown in the following 2 tables.
Inlet Gas Supply Pressure
Fuel # Minimum Maximum Desired
Nat.
Gas
5" WC/po. C.E
(1.24 kPa)
10.5" WC/po. C.E (2.61 kPa)
7" WC/po. C.E
(1.74 kPa)
Manifold Gas Supply Pressure
Fuel # Low High
Natural
Gas
(Lo) 1.7" WC/po. C.E
(0.42 kPa)
(Hi) 3.5" WC/po. C.E
(0.87 kPa)
Step 18. Reinstall the log set and glass door assembly. See Page 20 (Log
Set Installation) and Page 34 (Door Assembly Installation) in the Installation and Operation Manual.
Step 19. Light the appliance per the lighting instructions label on appliance
(located below glass door) or lighting instructions on Page 28 of the Installation and Operation Manual. Inspect for proper pilot and burner flame appearances (see Figures 10 and 11). Also see Flame Color and Behavior and Inspect The Pilot System
For Proper Flame on Page 29 of the Installation and Operation Manual.
Figure 10 - Proper Pilot Flame Appearance
Soot at Flame Tip
Dark Orange Flame
No Blue Flame Center
IMPROPERLY
BURNING FLAME
Soot above Flame Tip
Ports on Pan
Burner Assembly
PROPERLY
BURNING FLAME
Figure 11 - Burner Flame Appearance
No Soot at Flame Tip
Semi-Transparent Yellow Flame
Blue Flame Center
NOTE: DIAGRAMS AND ILLUSTRATIONS ARE NOT TO SCALE.
Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.
Printed in U.S.A. © 2008 Lennox Hearth Products
P/N 775,241M REV. A 08/2008