Compressor − limited warranty for five years.
All other covered components − one year.
Refer to Lennox Equipment Limited Warranty certificate
included with unit for specific details.
Approvals
Certified in Accordance with the USE certification
program, which is based on ARI Standard 210/240−2005.
Sound rated in Lennox reverberant sound test room in
Accordance with test conditions included in ARI Standard
270-95.
Tested in the Lennox Research Laboratory environmental
test room.
Rated According to U.S. Department of Energy (DOE)
test procedures.
Units and components within bonded for grounding to
meet safety standards for servicing required by UL, NEC
and CEC.
Units are UL listed and CSA certified.
ISO 9001 Registered Manufacturing Quality System.
E
NERGY STAR® certified units are designed to use less
energy, help save money on utility bills, and help protect
the environment.
Applications
SEER up to 14.0.
3 through 5 ton.
Three−phase power supply.
Vertical air discharge allows concealment behind shrubs
at grade level or out of sight on a roof.
Matching add-on furnace indoor coils or air handlers
provide a wide range of cooling capacities and
applications. See ARI Ratings table.
See Indoor Coils and Air Handlers tab sections for unit
data.
Units shipped completely factory assembled, piped and
wired. Each unit test operated at the factory ensuring
proper operation.
Installer must set air conditioner, connect refrigerant lines
and make electrical connections to complete job.
For expanded ratings, see www.lennoxcommercial.com.
B
C
D
REFRIGERANT SYSTEM
Refrigerant
Non−chlorine, ozone friendly, R−410A.
Unit pre−charged with refrigerant. See Specification table.
Condenser Fan
B
Direct drive fan moves large air volumes uniformly
through entire condenser coil for high refrigerant cooling
capacity.
Vertical air discharge minimizes operating sounds and
eliminates damage to lawn and shrubs.
Fan motor has sleeve bearings and is inherently
protected.
Motor totally enclosed for maximum protection from
weather, dust and corrosion.
Rain shield on motor provides additional protection from
moisture.
Louvered steel top fan guard furnished as standard.
Fan service access accomplished by removal of top
panel.
E
F
TS − 3 to 5 Ton R−410A Air Conditioners / Page 2
FEATURES
REFRIGERANT SYSTEM − CONTINUED
Copper Tube/Enhanced Fin Coil
C
Lennox designed and fabricated coil.
Ripple-edged aluminum fins.
Copper tube construction.
Lanced fins provide maximum exposure of fin surface to
air stream resulting in excellent heat transfer.
Fin collars grip tubing for maximum contact area.
Flared shoulder tubing connections/silver soldering
construction.
Coil is factory tested under high pressure to ensure
leakproof construction.
Entire coil is accessible for cleaning.
PVC coated steel wire coil guard furnished as standard.
High Pressure Switch Kit
Protects the system from high pressure conditions that
can be a result of fan failure or a blocked/dirty coil.
Manual reset.
OPTIONS
Expansion Valve Kits
Must be ordered extra and field installed on certain indoor
units. See ARI Ratings tables.
Chatleff−style fittings.
Loss of Charge Kit
Helps protect the compressor from damage due to low
refrigerant charge conditions.
SPST, normally−closed switch, automatic reset switch
mounted on suction line.
Refrigerant Line Kits
Refrigerant lines (suction & liquid) are shipped refrigeration
clean. Lines are cleaned, dried, pressurized and sealed at
factory.
Suction line fully insulated.
Lines are stubbed at both ends.
Not available for −060 models and must be field fabricated.
Compressor
Copeland Scrollt Compressor
D
Compressor features high
efficiency with uniform suction
flow, constant discharge flow
and high volumetric efficiency
and quiet operation.
Compressor consists of two
involute spiral scrolls matched
together to generate a series of
crescent shaped gas pockets
between them.
During compression, one scroll
remains stationary while the
other scroll orbits around it.
Gas is drawn into the outer
pocket, the pocket is sealed as
the scroll rotates.
As the spiral movement
continues, gas pockets are pushed to the center of the
scrolls. Volume between the pockets is simultaneously
reduced.
When pocket reaches the center, gas is now at high
pressure and is forced out of a port located in the center of
the fixed scrolls.
During compression, several pockets are compressed
simultaneously resulting in a smooth continuous
compression cycle.
Continuous flank contact, maintained by centrifugal force,
minimizes gas leakage and maximizes efficiency.
Scroll compressor is tolerant to the effects of slugging and
contaminants. If this occurs, scrolls separate, allowing
liquid or contaminants to to be worked toward the center
and discharged.
Low gas pulses during compression reduces operational
sound levels.
Compressor motor is internally protected from excessive
current and temperature.
Compressor is installed in the unit on resilient rubber
mounts for vibration free operation.
Compressor Crankcase Heater
Protects against refrigerant migration that can occur
during low ambient operation.
OPTIONS
Compressor Low Ambient Cut−Off
Non-adjustable switch (low ambient cut-out) prevents
compressor operation when outdoor temperature is
below 35°F.
Compressor Sound Cover
A reinforced vinyl compressor cover containing a 1−1/2
inch thick batt of fiberglass insulation.
All open edges are sealed with a one−inch wide hook and
loop fastening tape.
Compressor Timed−Off Control
Kit prevents compressor short−cycling and allows time for
suction and discharge pressure to equalize.
Permits compressor start−up in an unloaded condition.
Automatic reset with 5 minute delay between compressor
shut−off and start−up.
TS − 3 to 5 Ton R−410A Air Conditioners / Page 3
FEATURES
Cabinet
E
Heavy gauge steel cabinet with five station metal wash
process.
Powder paint finish provides superior rust and corrosion
protection.
Painted base section.
Control box is conveniently located with all controls
factory wired.
Corner patch plate allows access to compressor
components.
Drainage holes are provided in base section for moisture
removal.
Refrigerant Line Connections, Electrical Inlets,
F
Service Valves
Sweat connection suction and liquid lines are located on
corner of unit cabinet.
Fully serviceable brass service valves prevent corrosion
and provide access to refrigerant system. Suction valve
can be fully shut off, while liquid valve may be front seated
to manage refrigerant charge while servicing system.
Refrigerant line connections and field wiring inlets are
located in one central area of cabinet for easy access. See
dimension drawing.
OPTIONS
Hail Guards
Constructed of louvered heavy gauge steel painted to
match cabinet.
Surrounds unit on all four sides to prevent damage to the coil.
Mounting Base
Provides permanent foundation for outdoor units.
High density polyethylene structural material is
lightweight, sturdy, sound absorbing and will withstand the
rigors of the sun, heat, cold, moisture, oil and refrigerant.
Will not mildew or rot.
Can be shipped singly or in packages of 6 to a carton.
Unit Stand-Off Kit
Black high density polyethylene feet are available to raise
unit off of mounting surface away from damaging
moisture.
Four feet are furnished per order number.
CONTROLS
OPTIONS
L Connection® Network
See L Connection Engineering Handbook Bulletin in
Controls section for details.
Low Ambient Control
Air conditioners operate satisfactorily down to 45°F
outdoor air temperature without any additional controls.
The Low Ambient Control Kit allows unit operation down
to 30°F.
Freezestat should be installed on compressors equipped
with a low ambient kit.
A compressor lock−out thermostat should be added to
terminate compressor operation below recommended
operation conditions.
Freezestat
Installs on or near the vapor line of the indoor coil or on the
suction line.
Senses suction line temperature and cycles the
compressor off when suction line temperature falls below
it’s setpoint.
Opens at 29°F and closes at 58°F.
Time Delay Relay Kit
Delays the indoor blower−off time during the cooling cycle.
See ARI Rating Tables for usage.
TS − 3 to 5 Ton R−410A Air Conditioners / Page 4
OPTIONAL CONVENTIONAL TEMPERATURE CONTROL SYSTEMS − FIElD INSTALLED
COMMERCIAL TOUCHSCREEN THERMOSTAT
Intuitive Touchscreen Interface − Two Stage Heating / Two Stage Cooling Conventional or
Heat Pump − Seven Day Programmable − Four Time Periods/Day − Economizer Output − Title 24
Remote sensors for C0STAT02AE1L can be applied in the following combinations: (1)
C0SNZN01AE1−, (2) C0SNZN73AE1−, (2) C0SNZN01AE1− and (1) C0SNZN73AE1−, (4)
C0SNZN01AE1−, (3) C0SNZN01AE1− and (2) C0SNZN73AE1.
DIGITAL NON−PROGRAMMABLE THERMOSTATS
Intuitive Interface − Automatic Changeover − Simple Up and Down Temperature Control