Heat
TPA048H4 4 TON
Up−Flow Indoor Coils + Furnaces Up−Flow Coils + Furnaces
49,000 46,000 29,600 14.50 12.00 8.20 7.20 4085 3805 3475 3.54 2.50 CX34−60D−6F
4
G60UHV−60D−135 Factory TXV
49,000 46,000 29,800 14.50 12.00 8.20 7.20 4085 3835 3520 3.52 2.48 CX34−60D−6F
4
G61MPV−60D−135 Factory TXV
49,000 46,000 29,800 14.50 12.00 8.20 7.20 4085 3835 3520 3.52 2.48 CX34−60D−6F
4
G71MPP−60D−135 Factory TXV
49,000 46,500 29,800 14.00 12.00 8.20 7.20 4085 3835 3520 3.56 2.48 CX34−49C−6F
4
G60UHV−60C−110 Factory TXV
49,000 46,500 30,000 14.00 12.00 8.20 7.20 4085 3875 3555 3.52 2.48 CX34−49C−6F
4
G61MPV−60C−090 Factory TXV
49,000 46,500 30,000 14.00 12.00 8.20 7.20 4085 3875 3555 3.52 2.48 CX34−49C−6F
4
G71MPP−60C−090 Factory TXV
49,000 46,500 30,000 14.00 12.00 8.20 7.20 4085 3875 3555 3.52 2.48 CX34−49C−6F
4
G61MPV−60C−110 Factory TXV
49,000 46,500 30,000 14.00 12.00 8.20 7.20 4085 3875 3555 3.52 2.48 CX34−49C−6F
4
G71MPP−60C−110 Factory TXV
49,000 46,500 30,000 14.00 12.00 8.20 7.20 4085 3880 3560 3.52 2.46 CX34−49C−6F
4
G61MPV−60C−111 Factory TXV
49,000 46,500 30,200 14.00 12.00 8.20 7.20 4085 3920 3610 3.48 2.44 CX34−49C−6F
4
G61MPV−60C−091 Factory TXV
49,500 46,000 29,600 14.50 12.00 8.20 7.20 4125 3765 3440 3.58 2.52 CX34−62D−6F
4
G60UHV−60D−135 Factory TXV
49,500 46,500 29,800 14.50 12.00 8.20 7.20 4125 3820 3510 3.56 2.48 CX34−49C−6F
4
G60UHV−60C−090 Factory TXV
49,500 46,500 29,800 14.50 12.00 8.20 7.20 4125 3805 3485 3.58 2.50 CX34−62D−6F
4
G61MPV−60D−135 Factory TXV
49,500 46,500 29,800 14.50 12.00 8.20 7.20 4125 3805 3485 3.58 2.50 CX34−62D−6F
4
G71MPP−60D−135 Factory TXV
50,000 47,000 30,000 14.50 12.00 8.20 7.20 4165 3690 3395 3.74 2.58 CX34−62C−6F
4
G60UHV−60C−110 Factory TXV
50,000 47,000 30,200 14.50 12.00 8.20 7.20 4165 3690 3400 3.74 2.60 CX34−62C−6F
4
G60UHV−60C−090 Factory TXV
50,000 47,000 30,200 14.50 12.00 8.20 7.20 4165 3735 3445 3.68 2.56 CX34−62C−6F
4
G61MPV−60C−090 Factory TXV
50,000 47,000 30,200 14.50 12.00 8.20 7.20 4165 3735 3445 3.68 2.56 CX34−62C−6F
4
G71MPP−60C−090 Factory TXV
50,000 47,000 30,200 14.50 12.00 8.20 7.20 4165 3725 3435 3.70 2.58 CX34−62C−6F
4
G61MPV−60C−110 Factory TXV
50,000 47,000 30,200 14.50 12.00 8.20 7.20 4165 3725 3435 3.70 2.58 CX34−62C−6F
4
G71MPP−60C−110 Factory TXV
50,000 47,000 30,200 14.50 12.00 8.20 7.20 4165 3730 3440 3.70 2.58 CX34−62C−6F
4
G61MPV−60C−111 Factory TXV
50,000 47,500 30,400 14.00 12.00 8.20 7.20 4165 3775 3490 3.68 2.56 CX34−62C−6F
4
G61MPV−60C−091 Factory TXV
Down−Flow Indoor Coils Down−Flow Coils
47,500 47,500 30,600 13.00 11 .0 0 7.70 6.70 4320 3855 3555 3.62 2.52
3
CR33−50/60C−F
2
91M02
47,500 47,500 30,600 13.00 11 .0 0 7.70 6.70 4320 3855 3555 3.62 2.52
3
CR33−60D−F
2
91M02
Down−Flow Indoor Coils + Furnaces Down−Flow Coils + Furnaces
48,000 46,500 29,800 14.50 12.00 8.20 7.20 4000 3665 3345 3.72 2.60 CR33−60D−F
4
G60DFV−60D−135
2
91M02
48,000 46,500 30,000 14.00 12.00 8.20 7.20 4000 3665 3355 3.72 2.62 CR33−50/60C−F
4
G60DFV−60C−090
2
91M02
48,000 47,000 30,200 14.00 12.00 8.20 7.20 4000 3745 3445 3.68 2.56 CR33−50/60C−F
4
G61MPV−60C−090
2
91M02
48,000 47,000 30,200 14.00 12.00 8.20 7.20 4000 3745 3445 3.68 2.56 CR33−50/60C−F
4
G71MPP−60C−0902 91M02
48,000 47,000 30,200 14.00 12.00 8.20 7.20 4000 3735 3435 3.68 2.58 CR33−50/60C−F
4
G61MPV−60C−110
2
91M02
48,000 47,000 30,200 14.00 12.00 8.20 7.20 4000 3735 3435 3.68 2.58 CR33−50/60C−F
4
G71MPP−60C−1102 91M02
48,000 47,000 30,200 14.00 12.00 8.20 7.20 4000 3740 3440 3.68 2.58 CR33−50/60C−F
4
G61MPV−60C−111
2
91M02
48,000 47,000 30,400 13.00 11 .0 0 7.70 7.00 4365 3785 3490 3.64 2.56 CR33−50/60C−F
4
G61MPV−60C−091
2
91M02
48,500 47,000 30,200 14.00 12.00 8.20 7.20 4040 3680 3385 3.74 2.62 CR33−50/60C−F
4
G60DFV−60C−110
2
91M02
48,500 47,000 30,000 14.00 12.00 8.20 7.20 4040 3690 3385 3.74 2.60 CR33−60D−F
4
G61MPV−60D−135
2
91M02
48,500 47,000 30,000 14.00 12.00 8.20 7.20 4040 3690 3385 3.74 2.60 CR33−60D−F
4
G71MPP−60D−1352 91M02
NOTE − When used with gas furnaces, a dual−fuel control (i.e. FM21) or a control system with dual−fuel capabilities (i.e. Harmony III, LZP−2 or LZP−4) must be used (ordered extra).
1
Certified in accordance with USE certification program which is based on ARI Standard 210/240 with 25 ft. of connecting refrigerant lines;
Cooling Ratings − 95_F outdoor air temperature and 80_F db/67_F wb entering indoor coil air.
High Temperature Heating Ratings − 47_F db/43_F wb outdoor air temperature and 70_F db entering indoor coil air.
Low Temperature Heating Ratings − 17_F db/15_F wb outdoor air temperature and 70_F db entering indoor coil air.
2
Factory installed expansion valve or RFC on indoor unit MUST be replaced with valve specified (if equipped).
3
Blower must be capable of time−off blower delay. Indoor Blower Off Delay Relay (58M81) is recommend for field installation.
4
Blower control must be set for a time−off blower delay.