Lennox SDVSS-25-35, VISN-25-35 User Manual

P/N 775222M REV. F 09/2011
INSTALLATION AND OPERATION
DIRECT-VENT VISION™
MODELS
US
Portland
OTL Report No. 050-S-16b-5
VISN-25/35 SDVSS-25/35
Ce manuel d’installation est disponible en francais, s implement en faire la demande. Numéro de la pièce 775222CF.
WARNING
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
AVERTISSEMENT
This Gas Stove is factory equipped for 35,000 BTU input and can be converted to 25,000 using a smaller orifice (provided in optional orifice kit P/N H5966).
UNE SURFACE VITRÉE CHAUDE PEUT
CAUSER DES BRÛLURES.
LAISSER REFROIDIR LA SURFACE
VITRÉE AVANT D'Y TOUCHER.
NE PERMETTEZ JAMAIS À UN ENFANT
DE TOUCHER LA SURFACE VITRÉE.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a quali­fied installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
INSTALLATEUR: Laissez cette notice avec l'appareil. CONSOMMATEUR: Conservez cette notice pour consul­tation ultérieure.
AVERTISSEMENT: Assurez-vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d’incindie ou d’explosion ou pour éviter tout dommage matériel, toute blessure ou la mort.
- Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir des téléphones se trouvant dans le bâtiment où vous trouvez.
• Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournis­seur.
• Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le service des incindies.
- L’installation et l’entretien doivent être assurés par un installateur ou un service d’entretien qualifié ou par le fournisseur de gaz.
CONGRATULATIONS!
When you purchased your new gas stove, you joined the ranks of thousands of individuals whose answer to their home heat­ing needs reflects their concern for aesthetics, efficiency and our environment. We extend our continued support to help you achieve the maximum benefit and enjoyment available from your new gas stove.
Thank you for selecting a Lennox Hearth Products gas stove as the answer to your home heating needs.
TABLE OF CONTENTS
Using this Manual ...................................................... 2
Safety and Warning Information ....................................3-4
Homeowner - Attaching Safety In Operation Warnings ............... 5
Orifice Size / Altitude Adjustment ....................................6
Smoke Detectors ........................................................ 6
The Gas Stove ........................................................... 6
Codes and Approvals ................................................... 7
Commonwealth Of Massachusetts Requirements ................. 7
New York City, New York (MEA) ...................................... 7
Pre-Installation...................................................... 8-10
Features ......................................................... 8
Packaging List ........................................................... 8
Ratings .......................................................... 8
Preparing Your Stove For Installation ...................... 9
Dimensions ..................................................... 9
Clearances to Combustibles ................................10
Installation ..........................................................11-12
Installing Door Trim And Spring Handle ..................11
Brick Panel, Log Set and Ember Installation .........12-13
Vent Installation ...................................................13-17
Venting .........................................................13
Residential and Mobile Home Installations ..............13
Vent Considerations ..........................................13
Vent Parts List .................................................14
Horizontal Vent Installation .................................14
Vertical Vent Installation ....................................15
Flue Restrictors ...............................................15
Horizontal Terminations .....................................16
Vertical Terminations ........................................16
Horizontal Vent Termination Locations ....................17
Gas Line Installation ..................................................18
Gas Pressure Requirements ................................18
LP and Natural Gas Supplies ...............................18
Installer - Attaching Safety In Operation Warnings .................. 19
Operating Instructions ............................................20-23
Pre-Lighting Checklist .......................................20
Lighting Instructions .....................................20-21
Flame Color and Behavior ...................................21
Air Shutter Adjustment .......................................22
Quiet Operation ...............................................22
Paint Curing ...................................................22
Optional Wall Thermostat ...................................22
Operating Options ............................................23
Millivolt Control System .....................................23
Maintenance and Servicing ......................................24-26
Maintenance Checklist .......................................24
Millivolt and Systems Checks ..............................24
Vent Pipe Maintenance ......................................24
Opening and Removing Door ...............................25
Glass Door Cleaning and Maintenance ...................25
Fuel Conversion ...............................................26
Troubleshooting ........................................................27
Blower Wire Harness Diagram ......................................28
Replacement Parts List ...............................................29
Accessories .............................................................30
Stove Labels ........................................................31-32
Product Reference Information ......................................34
USING THIS MANUAL
Please read and carefully follow all of the instructions found in this manual. Please pay special attention to the safety instructions provided in this manual.
PRODUCT IS SUBJECT TO CHANGE WITHOUT NOTICE
2
IMPORTANT SAFETY AND WARNING INFORMATION
WARNING
Young children should be carefully supervised when they are in the same room as the appliance. Tod­dlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces.
AVERTISSEMENT
Les jeunes enfants devraient être surveillés étroite­ment lorsqu’ils se trouvent dans la même pièce que l’appareil. Les tout petits, les jeunes enfants ou les adultes peuvent subir des brûlures s’ils viennent en contact avec la surface chaude. Il est recommandé d’installer une barrière physique si des personnes à risques habitent la maison. Pour empêcher l’accès à un foyer ou à un poêle, installez une barrière de sécurité; cette mesure empêchera les tout petits, les jeunes enfants et toute autre personne à risque d’avoir accès à la pièce et aux surfaces chaudes.
WARNING
Improper installation, adjustment, alteration, ser­vice or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
WARNING
AVERTISSEMENT
On ne devrait pas placer de vêtements ni d’autres matières inflammables sur l’appareil ni à prox­imité.
WARNING
Any safety screen or guard removed for servicing the appliance must be replaced prior to operating the appliance.
AVERTISSEMENT
Tout écran ou protecteur retiré pour permettre l’entretien de l’appareil doit être remis en place avant de mettre l’appareil en marche.
WARNING
Improper installation or use of this appliance can cause serious injury or death from fire, burns, explosion or carbon monoxide poisoning.
WARNING
Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition.
AVERTISSEMENT
Les enfants et les adultes devraient être infor-més des dangers que posent les températures de surface élevées et se tenir à distance afin d’éviter des brûlures ou que leurs vêtements ne s’enflamment.
Failure to comply with these installation instructions will result in an improperly installed and operating appliance, voiding its warranty. Any change to this appliance and/or its operating controls is danger­ous.
WARNING
Clothing or other flammable material should not be placed on or near the appliance.
WARNING
DO NOT ATTEMPT TO ALTER OR MODIFY THE CON­STRUCTION OF THE APPLIANCE OR ITS COMPO­NENTS. ANY MODIFICATION OR ALTERATION MAY VOID THE WARRANTY, CERTIFICATION AND LISTINGS OF THIS UNIT.
3
FOR YOUR SAFETY do not install or operate this appliance without
first reading and understanding this manual. Any installation or operation of the appliance deviating from that which is stated in this manual WILL void the warranty and may be hazardous.
INSTALLATION AND REPAIR SHOULD ONLY BE DONE BY
A QUALIFIED SERVICE TECHNICIAN. DO NOT ATTEMPT TO SERVICE THE APPLIANCE YOURSELF.
Do not make any make-shift compromises during installation.
Any modification or alteration may result in damage to the ap­pliance or dwelling and will void the warranty, certification and listings of this unit.
Failure to use manufacturer provided parts, variations in tech-
niques and construction materials or practices other than those described in this manual may create a fire hazard and void the limited warranty.
This gas appliance must be equipped for the proper fuel type
and altitude at which it will be operated. Any operation outside the parameters outlined in this manual may result in a hazard­ous condition and will void the warranty. Please carefully read the sections pertaining to these subjects and/or be sure your appliance is properly equipped.
Never use solid fuels such as wood, paper, cardboard, coal, or
any flammable liquids, etc., in this appliance.
Any grill, panel, or glass removed for service MUST be replaced
prior to operating the appliance. Do not operate the appliance with glass removed, cracked or broken.
These appliances are vented gas appliances. Do not burn wood
or other material in these appliances.
This appliance is only for use with the type of gas indicated on
rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil doit être utilisé uniquement avec les types de gaz
indiqués sur la plaque signalétique. Ne pas l'utiliser avec d'autres gaz sauf si un kit de conversion certifié est installé.
Hot while in operation. Do not touch. Severe Burns may result.
Keep children, clothing furniture, gasoline and other liquids having flammable vapors away.
L’appareil est chaud lorsqu’il fonctionne. Ne pas toucher
l’appareil. Risque de brûlures graves. Surveiller les enfants. Garder les vêtements, les meubles, l’essence ou autres liquides produisant des vapeur inflammables loin de l’appareil.
This appliance may be installed in an aftermarket, permanently
located, manufactured home (USA only) or mobile home, where not prohibited by local codes.
Cet appareil peut être installé dans une maison préfabriquée
(mobile) déjà installée à demeure si les règlements locaux le permettent.
Ensure clearances are in accordance with local installation
codes and the requirements of the gas supplier.
Dégagement conforme aux codes d'installation locaux et aux
exigences du foumisseunde gaz.
Plated surfaces must be cleaned with glass cleaner and a clean
soft cloth before firing the first time or fingerprints will remain permanently. NEVER use brass polish to clean gold or nickel, this will remove the plating!!!
When opening the lower door on the face while the appliance is
burning, pull at the far left or far right vent openings, because the door is hot during operation.
LHP, its employees, or any of its representatives assume no
responsibility for any damages caused by an inoperable, inad­equate, or unsafe condition as a result of any improper operation, service or installation procedures, whether direct or indirect.
Due to high temperatures, the appliance should be located out
of traffic and away from furniture and draperies.
En raison des températures élevées, l’appareil devrait être
installé dans un endroit où il y a peu de circulation et loin du mobilier et des tentures.
Provide adequate clearances around air openings and adequate
accessibility clearance for service and proper operation. Never obstruct the front openings of the appliance.
These appliances are designed to operate on natural or propane
gas only. The use of other fuels or combination of fuels will de­grade the performance of this system and may be dangerous.
These appliances are designed as supplemental heaters. There-
fore, it is advisable to have an alternate primary heat source when installed in a dwelling.
These appliances must not be connected to a chimney or flue
serving a separate solid fuel burning appliance.
Installation and repair should be done by a qualified service
person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpet­ing, bedding material, etcetera. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean.
L’installation et la réparation devrait être confiées à un technicien
qualifié. L’appareil devrait faire l’objet d’une inspection par un technicien professionnel avant d’être utilisé et au moins une fois l’an par la suite. Des nettoyages plus fréquents peuvent être nécessaires si les tapis, la literie, et cetera produisent une quantité importante de pous-sière. Il est essentiel que les com­partiments abritant les commandes, les brûleurs et les conduits de circulation d’air de l’appareil soient tenus propres.
Do not use these appliances if any part has been under water.
Immediately call a qualified, professional service technician to inspect the appliance and to replace any parts of the control system and any gas control which have been under water.
Ne pas utiliser cet appareil s’il a été plongé, même partielle-
ment, dans l’eau. Appeler un technicien qualifié pour inspecter l’appareil et remplacer toute partie du système de commande et toute commande qui a été plongée dans l’eau.
Only trim kit(s) supplied by the manufacturer shall be used in
the installation of this appliance.
Seules les trousses de garniture fournies par le fabricant doivent
être utilisées pour l’installation de cet appareil.
INSTALLER: THESE INSTRUCTIONS ARE TO REMAIN WITH THE
HOME OWNER!
4
HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY-IN-OPERATION WARNINGS
ATTACHING SAFETY-IN-OPERATION WARNINGS
Your gas stove has been furnished with safety instruction labels that are to be affixed to the opera­tion and control point of the gas stove. A safety instruction label should be affixed to the wall switch plate where the gas stove is turned on and off (See Figure A) or wall thermostat (See Figure B) and if used on the remote control handheld transmitter (Figure C). The warnings should already have been put in place when the gas stove initial set-up was completed. If they are not affixed at these spots, locate the multi-lingual adhesive labels provided with these instructions and proceed as follows:
1. Locate the wall switch or wall thermostat that controls the gas stove (verify the switch operates the gas stove by turning it on and off). Clean the wall switch plate or wall thermostat thoroughly to remove any dust and oils. Affix the label to the surface of the plate of the wall switch that controls the gas stove (Figure A) or the wall thermostat (Figure B). Choose the language primarily spoken in the home.
2. If a remote control is used to control the gas stove, locate the transmitter and clean it thoroughly to remove any dust and oils. Affix the label to the surface of handheld transmitter (Figure C). Choose the language primarily spoken in the home.
3. If you are unable to locate the labels, please call Lennox Hearth Products or your nearest Lennox Hearth Products dealer to receive additional safety instruction labels free of charge.
Cat. No. H8024 Replacement Label Kit
LENNOX HEARTH PRODUCTS 1-800-9-LENNOX
Note: English is red text on clear label. French and Spanish are white text on black label.
APPOSITION DES MISES EN GARDE RELATIVES À LA SÉCURITÉ D’UTILISATION
Votre foyer a été livré avec des étiquettes de sécurité qui doivent être collées à côté des dispositifs de contrôle du foyer. Une étiquette de sécurité doit être collée sur la plaque de l’interrupteur contrôlant l’allumage du foyer (voir Figure A) ou sur le thermostat mural (voir Figure B) et, le cas échéant, sur le boîtier de la télé- commande (Figure C). Les mises en garde auraient dû être collées au moment de l’installation initiale du foyer. Si ce n’est pas le cas, prenez les étiquettes adhésives multilingues fournies avec ces instructions et procédez comme suit:
1. Repérez l’interrupteur ou le thermostat mural qui contrôle le foyer (vérifiez que l’interrupteur contrôle le fonctionnement du foyer en le faisant basculer de Marche à Arrêt, et vice-versa). Nettoyez soigneusement la plaque murale de l’interrupteur ou le thermostat mural pour éliminer la poussière et les traces de graisse ou d’huile. Collez l’étiquette sur la surface de la plaque de l’interrupteur mural qui contrôle le foyer (Figure A) ou du thermostat mural (Figure B). Choisissez la langue qui est principalement parlée dans la résidence du propriétaire.
2. Si une télécommande est utilisée pour contrôler le foyer, nettoyez la soigneusement pour éliminer la poussière et les traces de graisse ou d’huile. Collez l’étiquette sur le boîtier de la télécommande (Figure C). Choisissez la langue qui est principale- ment parlée dans la résidence du propriétaire.
3. Si vous ne trouvez pas les étiquettes, veuillez appeler Lennox Hearth Products ou votre distribu­teur Lennox Hearth Products local pour recevoir gratuitement des étiquettes supplémentaires.
Étiquettes de remplacement, n° cat. H8024
LENNOX HEARTH PRODUCTS 1-800-9-LENNOX
Remarque : Le texte anglais est rouge sur un support transparent. Le texte français et espagnol est blanc sur un support noir.
COLOCACIóN DE ADVERTENCIAS DE SEGURIDAD EN OPERACIóN
Su chimenea incluye etiquetas de instrucciones de seguridad que deben colocarse en el punto de operación y control de la chimenea. Se debe colocar una etiqueta de instrucciones de seguridad en la placa del interruptor de pared desde el cual se enciende y se apaga la chimenea
(ver la Figura A) o en el termostato de pared (ver la Figura B) y en el transmisor de control remoto (Figura C) si
se usa. Las advertencias ya deben haberse colocado cuando se completó la instalación inicial de la chimenea. Si no están colocadas en estos lugares, encuentre las etiquetas adhesivas multilingües proporcionadas con estas instrucciones y prosiga de la siguiente manera:
1. Identifique el interruptor o el termostato de pared que controla la chimenea (verifique que el interruptor opera la chimenea encendiéndola y apagándola). Limpie bien la placa del interruptor o el termostato de pared para quitar el polvo y aceite. Pegue la etiqueta en la superficie de la placa del interruptor que controla la chimenea (Figura A) o en el termostato de pared (Figura B). Seleccione el idioma que más se habla en la casa.
2. Si se usa un control remoto para controlar la chimenea, encuentre el transmisor y límpielo bien para quitar el polvo y aceite. Pegue la etiqueta en la superficie del transmisor (Figura C). Seleccione el idioma que más se habla en la casa.
3. Si no puede encontrar las etiquetas, sírvase llamar a Lennox Hearth Products o al distribuidor de Lennox Hearth Products más cercano para recibir etiquetas de instrucciones de seguridad adicionales gratuitas.
Juego de etiquetas de repuesto - Nº de cat. H8024
LENNOX HEARTH PRODUCTS 1-800-9-LENNOX
Nota: La etiqueta en inglés es transparente con texto rojo. Las etiquetas en francés y español son negras con texto blanco.
Figure A
SAFETY LABEL
DIAGRAMS
DIAGRAMMES DES ÉTIQUETTES
DE SÉCURITÉ
Figure B
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
DIAGRAMAS DE ETIQUETAS
DE SEGURIDAD
Figure C
5
ORIFICE SIZE/ALTITUDE ADJUSTMENT
THE GAS STOVE
For altitudes above 2,000 feet (In Canada 4,500 FT/1370 M), the orifice should be de-rated by 4% for every 1,000 feet to maintain the proper ratio of gas to air. Improper orifice sizing may result in damage and unsafe conditions. Changing the orifice should only be done by a qualified service technician. Contact your Lennox Hearth Products dealer for proper orifice sizes (see Page 26 for more information).
SMOKE DETECTORS
Since there are always several potential sources of fire in any home, we recommend installing smoke detectors. If possible, install the smoke detector in a hallway adjacent to the room (to reduce the possibility of occasional false activation from the heat produced by the appliance). If your local code requires a smoke detector be installed within the same room, you must follow the requirements of your local code. Check with your local building department for requirements in your area.
• Must conform with all local, state and national installation codes. In the absence of local codes, the installation must conform with National Fuel Gas Code ANSI Z223.1 - latest edition, also known as NFPA 54 (In Canada, the current CAN/CSA B149.1 installation code). Refer to the National Fuel Gas Code and local zoning and code authorities for details on installation requirements.
• Mobile home installations must conform with the Mobile Home Con­struction and Safety Standard, Title 24 CFR, Part 3280 (in Canada CAN/CSA Z240 MH), or, when such a standard is not applicable, the Standard for Mobile Home Installations, ANSI A225.1 - latest edi­tion.
• Must be vented directly to the outside in accordance with the latest edition of the National Fuel Gas Code and must never be attached to a chimney serving a separate solid fuel burning appliance.
• Has been certified for use with either natural gas or propane.
• Is not for use with solid fuels.
• Is approved for sitting rooms and/or bedrooms.
6
CODES AND APPROVALS
COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS
Certification
Gas appliances must be tested and certified by a nationally recognized testing and certification laboratory to ANSI (American National Standard Institute) gas appliance safety standards.
This stove has been tested and certified by OMNI -Test Laboratories to ANSI Z21.88/CSA 2.33 Standard for Vented Gas Fireplace Heater and CGA
2.17-M91 and UL 307B Gas Burning Heating Appliances for Manufactured (Mobile) Homes in both USA and Canada.
It has met all necessary ANSI Standards and is fully certified for installa­tion in any community. If there are any questions or if you need further substantiation either write to or call your Lennox Hearth Products dealer. If you have further questions, please contact Lennox Hearth Products.
Check all local building and safety codes before installation. The instal­lation instructions and appropriate code requirements must be followed exactly and without compromise. In the absence of local codes the fol­lowing standards and codes must be followed.
The Installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54- latest
edition, or the Natural Gas and Propane Installation Code, CSA B149.1­latest edition.
The appliance, when installed, must be electrically grounded and wired in accordance with local codes or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70 - latest edition, or the Canadian Electrical Code, CSA C22.1 - latest edition.
(Massachusetts Approval #G3-0806-6)
These appliances are approved for installation in the US state of Mas­sachusetts if the following additional requirements are met:
• Install this appliance in accordance with Massachusetts Rules and Regulations 248 C.M.R. Sec. 5.08 2(a) through 2(e).
• Installation and repair must be done by a plumber or gas fitter licensed in the Commonwealth of Massachusetts.
• The flexible gas line connector used shall not exceed 36 inches (92 centimeters) in length.
• The individual manual shut-off must be a T-handle type valve.
Massachusetts Horizontal Vent Requirements
In the Commonwealth of Massachusetts, horizontal terminations installed less than seven (7) feet above the finished grade must comply with the following additional requirements:
• A hard wired carbon monoxide detector with an alarm and battery back-up must be installed on the floor level where the gas fireplace is installed. The carbon monoxide detector must comply with NFPA 720, be ANSI/UL 2034 listed and be ISA certified.
• A metal or plastic identification plate must be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade and be directly in line with the horizontal termination. The sign must read, in print size no less than one-half (1/2) inch in size, GAS
VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS.
NEW YORK CITY, NEW YORK (MEA)
Installation of these appliances are approved for installation in New York City in the US state of New York (MEA#: 138-07-E).
7
PRE-INSTALLATION
FEATURES
Installation Options
Residential Vented vertical and horizontal Manufactured (mobile) home Natural gas (NG) or propane (LP) Bedrooms Optional wall-mounted or remote thermostat
Venting
This appliance can be vented with Secure Vent™ direct-vent pipe by Security Chimneys™*. Coaxial pipe diameters are 6-5/8” outer and 4” inner. The combustion air for this stove is drawn from outside the house through the outer DV (direct-vent) pipe. Room air is not required for combustion.
Millivolt Valve
This appliance is operated with a millivolt valve and therefore burns even during a power outage.
Fuel
This appliance comes from the factory equipped to burn natural gas at a specified elevation. The appliance can be converted to burn LP gas (liquid propane) by changing the cassette (valve and pilot assembly) or installing a conversion kit. Only Lennox Hearth Products conversion kits can be used to convert from NG to LP or LP to NG. Contact your Lennox Hearth Products dealer for details.
Specifications
Pipe:Type - direct-vent Recommended manufacturer* Security™ Secure Vent* Diameter - 6-5/8” x 4” for all installations
When planning your installation, select the correct length of vent pipe for your particular requirements. Determine the minimum clearance to combustibles from the rear of the unit to the wall. It is also important to note the thickness of the wall. Before cutting the vent hole through the wall make sure that ALL vent and termination clearances (see Page
17) will be met.
Electrical
The standard fan motor requires 120 Volts AC for operation. The stove is not dependent on the fan or an outside electrical supply to operate.
WARNING - Electrical Grounding Instructions - This appliance is equipped with a three-prong (grounding) plug for your pro­tection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.
* Other approved chimney brand is Simpson Dura-Vent DV-GS.
RATINGS
NATURAL GAS LP GAS NATURAL GAS LP GAS
Max/Min Input BTUh 0-2,000 Feet (0-610 M
Manifold Pressure (IN. WC)
)u
35,000/23,000 35,000/23,500 25,000/17,500 25,000/18,000
Stove Packaging List
The gas stove comes with the following parts: 1 Stove Body with Burner Cassette 1 150 CFM Blower 1 Brick Panel 1 Log Set 1 Bag of Ember Material
1 Installation and Operation Manual
Options
• Wall-mounted or Remote Thermostat
• Painted, Gold, or Nickel Plated Door Trim and Grill Assembly (re­quired)
VISN-35 / SDVSS-35 VISN-25 / SDVSS-25
3.5 10.0 3.5 10.0
Min. Inlet Pressure (IN. WC)
Maximum heat output BTUs/hour-steady state 29,050 29,050 20,750 20,750
P4 Efficiency
Steady-State Efficiency v
O
rifice (DMS) 0-2,000 Feet (0-610 M)u
w
5.0 11 5.0 11
61.65% 65.74% 65.08% 66.56%
82-85% 82-85% 82-85% 82-85%
#34 (.111 IN). #50 (.070 IN). #42 (.093 IN). #53 (.059 IN).
uUnit factory equipped for 0-2000 FT/0-610 M, In Canada 0-4500 FT/0-1370 M
vThe Steady State Efficiency numbers based on maximum vent configuration.
wTested to CSA P.4.1-02 “Testing Method for Measuring Annual Fireplace Efficiency.
Electrical Rating: 120 VAC, 60 HZ, Less Than 2 Amps
8
Preparing Your Appliance For Installation
Dimensions
Read all instructions before beginning your installation. If instructions have not been read carefully, your installation could void your warranty and may create a serious fire, health, or other safety hazard.
The Lennox Hearth Products warranty will be voided if one of the fol­lowing occurs:
• Installation of any damaged stove or vent system component.
• Unauthorized modification of the direct-vent system.
• Installation other than as instructed by Lennox Hearth Products, Security Chimneys™, or Simpson Dura-Vent.
• Installation of any stove or vent system component not manufac­tured or approved by Lennox Hearth Products, Security Chimneys™, or Simpson Dura-Vent.
When planning the installation for your appliance, it’s necessary to consider the following:
• Where the unit is to be installed
• The vent system configuration to be used
• Gas supply (NG or LP)
• Electrical wiring
• Optional accessories (door trim/grill assembly and wall-mounted or remote thermostat)
The gas line attaches to the gas valve at the back of the stove 2-1/2” in from the left side of the stove and 8-1/2” up from the base of the unit. Test all gas connections for leaks with a gas leak test solution.
Top View
14-7/8”
(378mm)
Figure 2
Figure 1
Rear Vent Dimensions
Flue Collar
24-3/4”
(629mm)
Front View
18-1/2”
(470mm)
28”
(711mm)
32-1/2”
(826mm)
Figure 3
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
9
Clearances to Combustibles
Alcove dimensions
Minimum clearances to combustible materials in inches (millimeters):
Parallel Installation
2” (51 mm)
15” (381 mm)
Min.
24-1/4”
(616 mm)
Figure 4
Min.
Corner Installation
The minimum width between the alcove side walls is 51” 1295mm). The minimum height of the alcove is 46” (1168mm) and the maximum depth is 35” (889mm).
Alcove Dimensions
46”
(1168 mm)
Min.
35” (889 mm) Max.
51” (1295 mm) Min.
90°
5-5/8”
(143mm)
10”
(254mm)
8-7/8” (225mm)
10”
(254mm)
Figure 5
Pipe Clearances
All installations using a vertical termination cap must maintain one inch clearance between the direct-vent pipe and combustibles. For horizontal runs of pipe, one inch of clearance to combustibles on the sides and bottom and two inches on the top of the pipe is required. See Page 16 for allowable pipe configurations.
Figure 6
Floor Protection
A non-combustible hearth pad is not required. This stove may be installed on a combustible surface as long as the combustible material (such as carpeting) does not extend 1-1/2” (38 mm) vertically above the bottom of the base. Also, the floor beneath the stove must be stable, level, hard and strong enough to support the stove without a tipping hazard.
Carpet
1-1/2” Maximum
Leg on Combustible
Figure 7
10
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
INSTALLATION
Conversion from Standard 35,000 BTU To Optional 25,000 BTU Input
Installing Door Trim And Spring Handle
CAUTION: Always ensure that plated surfaces are clean and free of fingerprints before lighting stove. Fingerprints will leave permanent blemishes if left on plated surface when lit. When installation is complete, the trim should be gently cleaned with a soft cloth and either alcohol or glass cleaner. Do not overtighten nuts, overtightening can create visible dimples on the plated surface.
To install the trim on the door, first see Opening and Removing Door on Page 25. Slide the threaded studs on the trim through the holes in the door. Install the nuts on the studs to secure the trim to the door. Do not over tighten the nuts or they will snap the studs off. To install the spring handle, first close the door and screw the handle into the receiving nut. Then spray a household glass cleaner or water on the shaft of the handle to act as a lubricant. Next, twist the spring handle counterclockwise onto the shaft. Use a household glass cleaner or alcohol to remove any fingerprints prior to firing the stove.
To convert input from 35,000 BTUs to 25,000 BTU's, remove and replace the stock burner orifice with the #36 NG orifice supplied in the optional orifice kit P/N H5924. Pipe dope or other approved gas line sealant will need to be applied before inserting into bulkhead. The foil sticker sup­plied, stating Vision 25/SDVSS25, will need to be affixed over the model name Vision 35/SDVSS35 on the serial number label.
11
Brick Panel And Log Set Installation
If logs are not installed according to the log installation instruc­tions, flame impingement and improper combustion could occur and result in soot and/or excessive production of carbon monoxide (CO), a colorless, odorless, toxic gas.
The size and position of the log set is critical to achieve a safe, reliable and attractive flame pattern. Any attempt to use a differ­ent log set in the fireplace will void the warranty and will result in incomplete com- bustion, sooting and poor flame quality.
CAUTION: If the logs are not properly installed, your appliance will not function correctly.
Parts list: rear log, right log, left log, center log, brick panel (packaged
separately)
1. Remove the logs from the box and carefully unwrap them. The logs are fragile, so handle them with care.
2. Remove the brick retainer bracket from the upper left corner inside the stove.
Brick Retainer
5. Place ember material (rockwool) over ports. The ember material can be placed to obscure air holes, but do not cover the air holes.
* Fifty percent or less of ember material (rockwool) supplied should
be used in LP installations. Too much ember material will result in tall sooty flames.
Figure 10
6. The right front log (positioned with the black charred surface toward the front) should be placed on the peg protruding from the right side of the stove.
Figure 8
3. Install the brick panel and replace the brick retainer bracket.
4. Place the rear log on the back log supports. The charred surface of the log should face the front.
Figure 9
Log Inserts
Figure 11
7. Place the left log on burner supports with the charred surface facing up. The left log will only fit on the burner supports in one direction.
8. Place embers around the perimeter of the burner and sparingly in field of burner. Do not block air holes on the burner.
Left Log
Right Log
Embers
Figure 12
12
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
9. Set center log on support with charred surface toward you and rest against the rear log.
Figure 13
Vent Installation
Residential and Mobile Home Installations:
These are the minimum pieces required. Other parts may be required for your particular installation.
Minimum Components for Horizontal Installation:
Horizontal Termination Kit which includes:
• 1 6-5/8”x 6” Black Pipe
• 1 Riser Vent Terminal
• 1 Wall Penetration Heat Shield (Wall Thimble) (2 pcs)
• 1 Decorative Wall Trim (black)
• 1 Tube Mill-Pac
• Screws
Optional Components:
• 45º Elbow
• Vinyl Siding Shield for Riser Vent Terminal
• Vent Guard
• Snorkel Termination (36”)
• Snorkel Termination (14”)
• Wall Penetration Heat Shield
Vent Considerations
Venting:
This appliance has been tested and listed as a direct-vent heater system by OMNI-Test Laboratories, Portland, Oregon and is recommended for use with Security™ Secure Vent™ pipe*.
Important:
• Read all instructions carefully before starting the installation. Failure to follow these instructions may create a fire or other safety hazard and will void the warranty. Be sure to check for specific clearances to combustible requirements on Page 10.
Do not extend the venting system vertically or horizontally in excess of the distance prescribed on Page 16. Consult your
local building codes before beginning the installation.
Always maintain the proper air spaces between the vent pipe and nearby combustibles to prevent a fire hazard. Do not fill air spaces with insulation. Be sure to check the vent termina­tion clearance requirements from decks, windows, soffits, gas regulators, air supply inlets and public walkways, as specified in these installation instructions on Page 17 and local building codes.
This gas stove and vent system must be vented directly to
the outside of the building and never be attached to a chim­ney serving a separate solid fuel or gas-burning appliance.
Each direct-vent gas appliance must use its own separate vent system. Common vent systems are prohibited.
• This gas stove is recommended for use with Security™ Secure Vent pipe*. The appliances and vent manufacturers warranties will be voided and serious fire, health, or other safety hazards may result from any of the following actions:
- Installation of any damaged direct-vent component.
- Unauthorized modification of the direct-vent system.
- Installation of any vent component part not approved or manufactured by the approved vent manufacturer.
- Installation other than as instructed by Lennox Hearth Products and vent manufacturers instructions.
Twist-lock procedure: Four indentations on female ends of pipes and fittings are designed to slide straight onto male ends of adjacent pipes and fittings by orienting the four pipe indentations so they match and slide into the four entry slots. Push pipe sections completely together, then twist-lock one section clockwise approximately one-quarter turn until the two sections are fully locked. The female locking lugs will not be visible from the outside on the pipe or fittings. They may be located by examining the inside of the female ends.
Supports: Horizontal runs of vent must be supported every 3 feet. Wall straps are available for this purpose.
Pipe Sealing: If Simpson Dura-Vent pipe is used, the pipe must be sealed as follows: seal both the inner and outer pipes with a high temperature silicone sealant rated for at least 600º F (commonly know as “RTV”). Run a 1/8” bead of silicone around outside of male end of outer sleeve. Run a 1/8” bead of silicone about 1/4” from the end of the male inner pipe, which is found in the pipe to be attached above. Twist-lock the pipes or fittings together.
Female Locking Lugs
Sealant
Male Locking Lugs
Figure 14
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
13
Vent Parts List
Snorkel required for Vision 35 or
Secure Vent™ direct-vent pipe by Security Chimneys™* may be used with this appliance. Please see the lists below to verify the components avail­able from each direct-vent pipe manufacturer. Snorkel terminations are available for applications which may require vertical rise on the building exterior. The components listed below come in a galvanized finish. Most of the components are also available in a painted black finish. Add a “B” to the end of the part number when ordering if a black part is desired.
Security - Secure Vent 6-5/8”x 4” Pipe
Part Number Description
SV4LC 6” Pipe Length SV4L12 12” Pipe Length SV4L24 24” Pipe Length SV4L36 36” Pipe Length SV4L48 48” Pipe Length SV4LA 6” Pipe, Adjustable SV4LA12 12” Pipe, Adjustable SV4FA Flashing, 1/12 to 6/12 Roof Pitch SV4FB Flashing, 7/12 to 12/12 Roof Pitch SV4RSM Wall Radiation Shield SV4E46 45º Elbow SV4E90 90º Elbow SV4VS Vinyl Shield Protector SV4FC Storm Collar SV4CGV Vertical Termination Cap SV4BF Firestop SV4CHC Horizontal Termination Cap SV4STC36 Snorkel Termination Cap (36”) SV4STC14 Snorkel Termination Cap (14”)
SV4BM Wall Band
Simpson Dura-Vent GS 6-5/8”x 4” Pipe Part Number Description 908 6” Pipe Length 907 9” Pipe Length 906 12” Pipe Length 904 24” Pipe Length 903 36” Pipe Length 902 48” Pipe Length 911 11” to 14-5/8” Pipe, Adjustable 942 Wall Thimble 940 Rnd Support Box/Wall Thimble Cover 941 Cathedral Ceiling Support Box 943 Flashing, 0/12 to 6/12 Roof Pitch 943S Flashing, 7/12 to 12/12 Roof Pitch 945 45º Elbow 990 90º Elbow 950 Vinyl Siding Standoff 953 Storm Collar 963 Ceiling Firestop 988 Wall Strap 981 Snorkel Termination (36”) 982 Snorkel Termination (14”) 984 Horizontal Termination Cap 985 Horizontal Termination Cap (High Wind) 980 Vertical Termination Cap 991 Vertical Termination Cap (High Wind)
Horizontal Vent Installation
Venting terminals may not be recessed into a wall or siding.
1) Set the unit in the desired location. Check whether or not wall studs are in the way when the venting system is attached. If wall studs are in the way, you may want to adjust the location of the unit.
2) Assemble the desired combination of pipe and elbow to the appliance adaptor with pipe seams facing down. Offsetting the pipe seams as double seams in one place will cause the outer pipe to take an oval shape. The Horizontal Termination Kit comes with 18” of straight vent
- 6-5/8” black outer pipe and 4” inner vent.
3) With the pipe attached to the stove, slide the stove into its correct location and mark the wall to the dimensions of the wall thimble (9-1/4” x 10-1/4”). The center of the round hole should line up with the centerline of the horizontal pipe. (9-1/4” is side-to-side dimen­sion and 10-1/4” is vertical dimension) If the wall being penetrated is constructed of non- combustible material (i.e. masonry block or concrete), a 7” diameter hole is acceptable.
4) The horizontal run of vent should have a 1/4” rise for every 1 foot of run toward the termination. Never allow the vent to run downward. This could cause high temperatures and may present the possibility of a fire.
5) The location of the horizontal vent termination on an exterior wall must meet all local and national building codes and must not be blocked or obstructed. For External Vent Termination Locations, see Page 17.
Snorkel Terminations: For installations requiring a vertical rise on
the exterior of the building, 14-inch (356 mm) and 36-inch (914 mm) tall Snorkel Terminations are available, as well as the standard Riser Vent. Follow the same installation procedures as used for standard Horizontal Termination. NEVER install the snorkel upside down.
Typical parts needed for a horizontal installation.
14” Snorkel for Vision 35 Standard Horizontal for Vision 25
Wall Thimble
Decorative Wall Trim
Pipe Length max min
Vision 25 if horizontal run exceeds 3 feet.
Figure 15
14
Light Obstructor
Flue Restrictors
14” Snorkel
min 12”
Figure 16
Vertical Vent Installation
Important Notes
1. All vertically terminated vent installations use 6-5/8” x 4” Security™ Secure Vent™ pipe*.
2. If the vent passes through a ceiling or floor, a firestop - Simpson #963 or Security #SV4BF - is required.
3. If the vent passes through the roof, a roof flashing - Simpson #943 or 943S or Security #SV4FA or SV4FB - and storm collar
- Simpson #953 or Security #SV4FC - are required.
4. A 1-inch clearance from the vent pipe to combustible materials must be maintained.
5. A maximum of either two 45º elbows or two 90º elbows may be used. See Page 16 for allowable offsets.
6. The maximum system height is 30 feet (9.1M) and the minimum is 10 feet (3M).
Vertical Termination Cap
The flue restrictor settings shown in Figures 19 and 20 are for typical installations and may need to be adjusted from standard to take into account other variables in the installation to achieve proper combus­tion. See Flue Restrictor Guidelines on this page to assist you in making a proper flue restrictor adjustment.
This stove requires a balanced flue to ensure proper combustion. As such, flue restrictors may need to be installed depending on the vent configuration of your stove. The drawings on the following page show all the allowable pipe configurations for this appliance. To properly in­stall the flue restrictor, find your pipe configuration in the drawings on the following page and note which restrictor setting is recommended. The flue restrictor is shipped in the firebox of your stove. To install the restrictor, see Figure 18. Remove the two 5/32” allen head screws (A below). Using pliers, repeatedly bend the unwanted portion of the flue restrictor and discard. Install the flue restrictor using the two 5/32” allen head screws according to the diagram below. Install the flue restrictor screws in their original holes in the top of the firebox. Restrictor posi­tions are based on tests run in a laboratory.
Flue Restrictor Adjustment Guidelines
After the flue restrictors have been changed to the standard flue restrictor settings as shown in Figures 19 and 20, the burner flame appearance should be evaluated to determine if the 1, 2 or 3 flue restrictor standard settings were the correct adjustment for variables in your installation. Light the appliance and allow it to burn for 20 minutes on the high setting. See Flame Color and Behavior on Pages 21 and 22 to determine if you have a proper burner flame appearance. If the proper flame appearance cannot be achieved, the flue restrictor may need to be changed to a dif­ferent position (1, 2 or 3). See the following guidelines to determine if you need to readjust the flue restrictors.
Before proceeding, confirm the manifold and inlet gas pressure is correct, primary air shutter is properly adjusted, venting system connections are secure and not blocked and if you are at a high elevation, ensure unit has been properly derated:
Symptoms - Lack of Combustion Air
If the symptoms listed below are present, you may need to adjust the flue restrictor to a more open position.
Storm Collar
Roof - Maintain 1” Clearance to Combustibles
Framing 10”x 10”
Ceiling Firestop
Figure 17
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
• Flame appears yellow
• Floating Flames (lazy, ill defined, quiet, may roll)
• Sooting
Flashing
• Pilot becomes yellow and appliance shuts down
Symptoms - Excessive Combustion Air
If the symptoms listed below are present, you may need to adjust the flue restrictor to a more closed position.
• Low Flame
• Pilot pulls and appliance shuts down
Pipe
• Pilot flame ghosts
Length
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
(only used for Vision25 w/short horizontal run & no flue restrictor)
Hand break to remove unwanted restrictor
Position 1
Position 2
Figure 18
A
Position 3
Flue Restrictor
15
Horizontal Terminations
25'
12'
13'
14'
15'
16'
17'
18'
19'
20'
13'
14'
16'
17'
15'
2'
3'
6'
7'8'9'
10'
11'
12'
4'
5'
5'
6'
7'
8'
9'
10'
11'
3'
4'
1'
0'
1'
2'
0'
18'
19'
20'
21'
22'
23'
24'
25'
#3
#2
#2
#2
#1
#1 #1
The shaded areas in the diagram below show all allowable combinations of vent configurations with horizontal terminations. Horizontal sections of pipe require 1/4” of rise for every 12” of run. A second 90 degree or 45 degree elbow (in addition to the first 90 degree elbow at the top of the vertical length of pipe) is allowed as long as the overall length of the horizontal run of pipe does not exceed those shown below. Use the restrictor positions indicated. Note that if the termination cap falls in the unshaded area below then no restrictor is installed in the stove.
uOne 45° elbow is allowed when venting horizontal, straight off
the back of the unit. See Figure 19.
To install the stove with pipe directly out the back, a snorkel is not required for VISN-25 / SDVSS-25 gas stoves. A snorkel is required for the VISN-35 / SDVSS-35 gas stoves. See Pages 14 and 15 for snorkel installation instructions.
Vertical Terminations
The diagram below shows all allowable combinations of straight verti­cal and offset to vertical vent configurations with vertical terminations. The termination must fall within the shaded areas on the diagram. Use the indicated restrictor positions. Offsets may consist of two 90 degree elbows OR four 45 degree elbows.
Horizontal Terminations
Vertical Terminations
24'
23'
22'
21'
20'
#3
Venting configurations may not terminate outside this parameter.
19'
18'
17'
#2
#1
16'
15'
14'
13'
12'
#2 #1
11'
10'
9'
8'
7'
#1
6'
5'
4'
3'
Vision 35 requires 14” snorkel
2'
1'
0'
Vision 25 standard cap
u See note
above
Figure 19
COMBINATION OF VERTICAL AND HORIZONTAL LENGTHS CANNOT EXCEED 25’.
Straight Horizontal With No Vertical
VISN-25 / SDVSS-25 - LP 0-3’ horizontal ................... Standard Horizontal Cap..................... Use Light Obstructor
VISN-25 / SDVSS-25 - NG 0-3’ horizontal................... Standard Horizontal Cap..................... Use Light Obstructor
VISN-35 / SDVSS-35 - LP 0-3’ horizontal.................... 14” Snorkel Required......................... No Light Obstructor
VISN-35 / SDVSS-35 - NG 0-3’ horizontal................... 14” Snorkel Required......................... No Light Obstructor*
Offsets must remain within maximum and minimum lines.
16
1'
2'3'4'
0'
5'6'7'
8'
9'
10'
12'
11'
13'
14'
17'
15'
16'
Figure 20
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Exterior Horizontal Vent Termination Clearance Requirements
Exterior Wall
Horizontal
Termination
B
V
L
X
= Air Supply Inlet
* See Item D in the Text Below.
*18”
Inside Corner
Center Line
of Termination
18”
DETAIL D
F
V
Ventilated Soffit
V
Fixed
Closed
Window
V
C
A
= Vent Terminal
V
Inside
Corner Detail
G
V
A
= 9" in U.S.
A
= 12" in Canada
H
3 ft.
B
C
C
C
Operable
V
Window
B
B
= Area where Terminal is NOT permitted
B
X
A
J
3 ft.
A
M
V
I
K
E
D
X
Minimum Clearances Canadian Installation * US Installation **
A = Clearance above grade, veranda, porch, deck
or balcony.
B = Clearance to window or door that may be opened. 6 in. (15.2 cm) for appliances < 10,000 BTU/hr (3kW),
C = Clearance to permanently closed window 12 inches (305 mm) recommended to prevent window
D = Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 18 in. (458 mm) from the center line of the terminal
E = Clearance to unventilated soffit 12 inches (30 cm) 12 inches (30 cm)
F = Clearance to outside corner 5 inches (12.7 cm) 5 inches (12.7 cm)
G = Clearance to inside corner 6 in. (15 cm) 6 in. (15 cm)
H = Clearance to each inside of center line extended above meter / regulator assembly
I = Clearance to service regulator vent outlet 3 feet (91 cm) * 3 feet (91 cm) **
J = Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance
K = Clearance to mechanical air supply inlet 6 feet (1.8 meters) * 3 feet (91 cm) above, if within 10 feet (3 m) horizontally**
L = Clearance above paved sidewalk or paved driveway located on public property
M = Clearance under veranda, porch, deck or balcony
* In accordance with the current CSA-B149.1 National Gas and B149.2 Propane Installation Code - Latest Editions.
** In accordance with the current ANSI Z223.1 / NFPA 54 National Fuel Codes - Latest Edition.
‡ A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.
*‡ Only permitted if veranda, porch, deck or balcony is fully open on a minimum 2 sides beneath the floor.
12 inches (30 cm) * 12 inches (30 cm) **
6 in. (15.2 cm) for appliances < 10,000 BTU/hr (3kW),
12 in. (30 cm) for appliances > 10,000 BTU/hr (3kW) and < 100,000 BTU/hr (30kW), 36 inches (91 cm) for appliances > 100,000 BTU/hr (30kW)*
9 in. (23 cm) for appliances > 10,000 BTU/hr (3kW) and < 50,000 BTU/hr (15kW), 12 inches (30 cm) for appliances > 50,000 BTU/hr (15kW)*
9 inches (229 mm) recommended to prevent window
condensation
condensation
18 inches (458 mm) 18 inches (458 mm)
3 feet (91 cm) within a height of 15 feet above the meter / regulator assembly *
6 in. (15.2 cm) for appliances < 10,000 BTU/hr (3kW), 12 in. (30 cm) for appliances > 10,000 BTU/hr (3kW) and < 100,000 BTU/hr (30kW), 36 inches (91 cm) for appliances > 100,000 BTU/hr (30kW)*
3 feet (91 cm) within a height of 15 feet above the meter / regulator assembly **
6 in. (15.2 cm) for appliances < 10,000 BTU/hr (3kW), 9 in. (23 cm) for appliances > 10,000 BTU/hr (3kW) and < 50,000 BTU/hr (15kW), 12 inches (30 cm) for appliances > 50,000 BTU/hr (15kW)*
7 feet (2.13 m) ‡ 7 feet (2.13 m) ‡
12 in. (30 cm) * ‡ 12 in. (30 cm) ** ‡
V
Figure 21
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
17
Gas Line Installation
This stove must be connected to the gas line in accordance with local codes and/or the National Fuel Gas Code, ANSI Z223.1 (In Canada, the current CAN/CSA B149.1 installation code). The gas line screws into the gas valve at the back of the stove 2-1/2” in from the left side of the stove and 8-1/2” up from the base of the unit. After connecting the gas line, all joints in the line and connections at the valve should be checked for leaks. After connecting the gas line, all joints in the line and connections at the valve should be checked for leaks before final positioning of the unit. Conduct a gas leakage test of the appliance piping and control system downstream of the shutoff valve in the supply line to the appliance.
Gas Pressure Requirements
A MAJOR CAUSE OF OPERATING PROBLEMS WITH GAS APPLIANCES IS IMPROPER GAS PRESSURE!
Fuel Type
Natural
Gas
LP Gas 11" WC 11" WC 13" WC 10" WC 6.0” WC
Desired Minimum Maximum On Hi
7" WC 5" WC 10.5" WC 3.5" WC 1.8" WC
Inlet Pressure Manifold Pressure
On Lo
Fire
SIT Millivolt Gas Valve
Fire
The most important item to check during the initial installation and the first thing to check when operating problems occur is gas pressure! This appliance will not function properly unless the required gas pressure is supplied. See the table on this page for gas pressure requirements.
Two pressure taps are provided on the appliance’s valve to check gas pressures. To access the taps, remove the two socket head screws from the valve control panel. The taps are located below the on/off/pilot knob. The left tap is the inlet (supply) pressure side. To check inlet pressure (with the appliance burning) insert a small flat-bladed screwdriver into the tap and turn a half-turn counterclockwise. Cover the tap with the line from the manometer and check the pressure. Close the tap gently but securely after completing the check. The manifold (outlet) tap is to the right of the inlet tap. To check manifold pressure (with the appliance burning at the high burn setting) insert a small flat-bladed screwdriver into the tap and turn a half-turn counterclockwise. Cover the tap with the line from the manometer and check the pressure. Again, close the tap gently but securely after completing the check. Check the taps for gas leaks with a gas leak test solution (retighten if necessary).
If the pressure is not sufficient, make sure the gas supply line is large enough, the supply regulator improperly adjusted and the total gas load for the residence does not exceed the amount supplied.
Gas Control Knob
(Pilot / On / Off)
Flame Height Control
Knob (HI/LO)
LP and Natural Gas Supplies
This appliance is equipped from the factory for use with natural gas only as specified on the Safety / Listing label attached to the appliance. This appliance can only be operated using propane gas (LP) if a certified fuel conversion kit provided by Lennox Hearth Products is installed by a qualified service technician.
Also check the orifice size on the label on the igniter bracket. It must be the correct size for the fuel and altitude.
Do not run propane tank dry. Running the tank dry may cause a hazardous condition due to pressure drop in empty tank.
Solid fuel is NOT to be used with this unit.
The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).
The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
18
INSTALLER INSTRUCTIONS - ATTACHING SAFETY-IN-OPERATION WARNINGS It is the installers responsibility to ensure these warnings are properly affixed during installation. These warning labels are a
critical step in informing consumers of safe operation of this appliance.
ATTACHING “SAFETY-IN-OPERATION” WARNINGS
It is required that the safety instruction labels fur­nished with the fireplace be affixed to the operation and control point of the fireplace. A safety instruction label must be affixed to the wall switch plate where the fireplace is turned on and off (See Figure A) or wall thermostat (See Figure B) and if used on the remote control handheld transmitter (Figure C). To properly complete the installation of this fireplace, locate the multi-lingual adhesive labels provided with the Care and Operation Instructions and proceed as follows:
1. Locate the wall switch or wall thermostat that controls the fireplace (verify the switch operates the fireplace by turning it on and off). Clean the wall switch plate or wall thermostat thoroughly to remove any dust and oils. Affix the label to the surface of the plate of the wall switch that controls the fireplace (Figure A) or the wall thermostat (Figure B). Choose the language primarily spoken in the home. If unknown, affix the English language label.
2. If a remote control is used to control the fireplace, locate the transmitter and clean it thoroughly to remove any dust and oils. Affix the label to the surface of handheld transmitter (Figure C). Choose the language primarily spoken in the home. If unknown, affix the English language label.
3. If you are unable to locate the labels, please call Lennox Hearth Products or your nearest Lennox Hearth Products dealer to receive additional safety instruction labels free of charge.
Cat. No. H8024 Replacement Label Kit
LENNOX HEARTH PRODUCTS 1-800-9-LENNOX
Note: English is red text on clear label. French and Spanish are white text on black label.
APPOSITION DES MISES EN GARDE RELATIVES À LA SÉCURITÉ D’UTILISATION
Il est impératif que les étiquettes de sécurité fournies avec le foyer soient collées à côté des dispositifs de contrôle du foyer. Une étiquette de sécurité doit être collée sur la plaque de l’interrupteur contrôlant l’allumage du foyer (voir Figure A) ou sur le thermostat mural (voir Figure B) et, le cas échéant, sur le boîtier de la télécommande (Figure C). Pour achever l’instal- lation correcte de ce foyer, procédez comme suit avec les étiquettes adhésives en langues étrangères fournies avec les instructions d’utilisation et d’entretien :
1. Repérez l’interrupteur ou le thermostat mural qui contrôle le foyer (vérifiez que l’interrupteur contrôle le fonctionnement du foyer en le faisant basculer de Marche à Arrêt, et vice-versa). Nettoyez soigneusement la plaque murale de l’interrupteur ou le thermostat mural pour éliminer la poussière et les traces de graisse ou d’huile. Collez l’étiquette sur la surface de la plaque de l’interrupteur mural qui contrôle le foyer (Figure A) ou du thermostat mural (Figure B). Choisissez la langue qui est principalement parlée dans la résidence du propriétaire. En cas de doute, collez l’étiquette en anglais.
2. Si une télécommande est utilisée pour contrôler le foyer, nettoyez la soigneusement pour éliminer la poussière et les traces de graisse ou d’huile. Collez l’étiquette sur le boîtier de la télé­commande (Figure C). Choisissez la langue qui est principalement parlée dans la résidence du proprié­taire. En cas de doute, collez l’étiquette en anglais.
3. Si vous ne trouvez pas les étiquettes, veuillez appeler Lennox Hearth Products ou votre distribu­teur Lennox Hearth Products local pour recevoir gratuitement des étiquettes supplémentaires.
Étiquettes de remplacement, n° cat. H8024
LENNOX HEARTH PRODUCTS 1-800-9-LENNOX
Remarque : Le texte anglais est rouge sur un support transparent. Le texte français et espagnol est blanc sur un support noir.
COLOCACIóN DE ADVERTENCIAS DE SEGURIDAD EN OPERACIóN
Se requiere que las etiquetas de instrucciones de seguridad incluidas con la chimenea se coloquen en el punto de operación y control de la misma. Se debe colocar una etiqueta de instrucciones de seguridad en la placa del interruptor de pared desde el cual se enciende y se apaga la chimenea (ver la Figura A) o en el termostato de pared (ver la Figura B) y en el transmisor de control remoto (Figura C) si se usa. Para completar correctamente la instalación de esta chimenea, encuentre las etiquetas adhesivas multilingües incluidas con las instrucciones de cuidado y operación y haga lo siguiente:
1. Identifique el interruptor o el termostato de pared que controla la chimenea (verifique que el interruptor opera la chimenea encendiéndola y apagándola). Limpie bien la placa del interruptor o el termostato de pared para quitar el polvo y aceite. Pegue la etiqueta en la superficie de la placa del interruptor que controla la chimenea (Figura A) o en el termostato de pared (Figura B). Seleccione el idioma que más se habla en la casa. Si no sabe cuál es, use la etiqueta en inglés.
2. Si se usa un control remoto para controlar la chimenea, encuentre el transmisor y límpielo bien para quitar el polvo y aceite. Pegue la etiqueta en la superficie del transmisor (Figura C). Seleccione el idioma que más se habla en la casa. Si no sabe cuál es, use la etiqueta en inglés.
3. Si no puede encontrar las etiquetas, sírvase llamar a Lennox Hearth Products o al distribuidor de Lennox Hearth Products más cercano para recibir etiquetas de instrucciones de seguridad adicionales gratuitas.
Juego de etiquetas de repuesto - Nº de cat. H8024
LENNOX HEARTH PRODUCTS 1-800-9-LENNOX
Nota: La etiqueta en inglés es transparente con texto rojo. Las etiquetas en francés y español son negras con texto blanco.
Figure A
SAFETY LABEL
DIAGRAMS
DIAGRAMMES DES ÉTIQUETTES
DE SÉCURITÉ
Figure B
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
DIAGRAMAS DE ETIQUETAS
DE SEGURIDAD
Figure C
19
Operating Instructions
WHAT TO DO IF YOU SMELL GAS:
Pre-Lighting Checklist
Be sure to check these items before the initial lighting of the stove: c The stove gas label corresponds to the gas supply available
- that is “natural gas” for natural gas or “LP gas” for LP gas.
c Gas pressure has been checked carefully - see Page 18. c All gas fittings have been checked for leaks. c All clearances to combustibles have been met - see Page
10.
c All combustible materials have been removed from area in
front of the stove.
c All vented areas of the stove are unobstructed. c House is ventilated to clear initial paint curing odors - see
Page 22.
c All packaging materials have been removed from the fire-
box.
c While stove is cool, fingerprints or other marks have been
cleaned from any gold or nickel surfaces with denatured alcohol and a soft cloth. Marks left on these surfaces may become etched into the finish if not removed prior to burning the unit.
c Brick panel, log set and embers have been installed. c The glass door is in place and is properly sealed.
Lighting Instructions
CAUTION: HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN, FURNITURE, GASOLINE AND OTHER LIQUIDS WITH FLAMMABLE VAPORS AWAY. NEVER OPERATE UNIT WITH GLASS OFF OR ATTEMPT TO REMOVE THE GLASS WHILE HOT.
CAUTION: YOUR LENNOX HEARTH PRODUCTS GAS APPLIANCE MUST ALWAYS BE OPERATED WITH GLASS IN PLACE.
The following is a copy of the operating and lighting instructions found with each stove:
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, INJURY, OR LOSS OF LIFE.
A. This appliance is equipped with a piezo ignition device to light the
pilot. When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING, smell around the appliance area for gas.
Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
• DO NOT try to light the appliance.
• DO NOT touch any electric switch; do not use any phone in
your building.
Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.
D. DO NOT use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
LIGHTING INSTRUCTIONS
1. STOP!! Read the safety information on this page before proceeding.
2. (If applicable) Set the thermostat to lowest setting. Turn wall on/off switch, unit mounted on/off switch or remote control switch “OFF.”
3. Turn off ALL electrical power to the appliance.
4. Open the lower door to access control compartment. Make sure gas supply shut-off cocks are open.
5. Push in gas cock dial slightly and turn clockwise to “OFF.”
Note: Dial cannot be turned from “PILOT” to “OFF” unless dial
is pushed in slightly. Do not force.
6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” on this page. If you don’t smell gas, go to the next step.
7. Locate the pilot by looking over the top of the left front log. A blue flame will be seen when the pilot is lit.
8. Turn the gas control knob counterclockwise to the "PILOT" position.
9. Push in control knob all the way and hold in. Immediately light the pilot by triggering the piezo igniter (pushing the button) until pilot lights. Continue to hold the control knob in for about 1-1/2 minutes after the pilot is lit. Release knob and it will pop back out. Pilot should remain lit. If it goes out, repeat steps 5-9.
• If knob does not pop up when released, stop and immediately call your service technician or gas supplier.
• If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier.
20
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
10. After pilot is lit, turn gas control knob counterclockwise
.2 to “ON.” Knob can only be turned to “ON” if the knob
has popped out.
11. To turn burner on, turn “ON/OFF” rocker switch to “ON” or set the thermostat to the desired temperature above room temperature.
12. Adjust the flame height (and heat output) by turning the flame height knob clockwise for full flame and counter­clockwise for reduced flame.
13. Turn on the electric power to the appliance and set the blower to the desired air flow after it turns on when the appliance reaches operating temperature.
Flame Height Control Knob
Figure 22
Gas Control Knob
(pilot/on/off)
ON
PILOT
OFF
- LO / HI +
Igniter
HI
LO
On/Off Switch
Blower
TO TURN OFF GAS TO APPLIANCE
1. Turn off the "ON/OFF" rocker switch and/or thermostat (if installed) to its lowest setting.
2. Turn off electric power to the appliance if service is to be performed.
3. Push in gas control knob slightly and turn clockwise
to "OFF." Do not force.
SHUTDOWN PROCEDURE
To turn off the burner, turn the rocker switch to "OFF" or adjust the thermostat (if installed) to a setting below room temperature. The pilot will remain lit for future burner ignition. For complete shutdown, see "TO TURN OFF GAS TO APPLIANCE" above.
IMPORTANT NOTE: When opening the lower door while the stove is burning, pull down on the bottom trim piece that extends beyond the lower door.
WARNINGS
• Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information, consult a qualified installer, service agency or your gas supplier. Operation of this appliance when not connected
• to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. Carbon monoxide poisoning – early signs of
• carbon monoxide poisoning resemble the flu with headaches, dizziness, or nausea. If you have these signs, get fresh air at once! Have the heater inspected by a qualified service technician. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol and those at high altitudes.
SIT Millivolt Gas Valve
Gas Control Knob
(Pilot / On / Off)
Flame Height Control
Knob (HI/LO)
Figure 23
Flame Color and Behavior
This appliance is designed for maximum heating efficiency. Therefore, upon lighting of the main burner the flames will be semi-transparent or “bluish.” After 10-20 minutes of operation the logs will heat up and the flames will become a yellow/orange color.
Adjusting the appliance to cause the flames to turn orange sooner may result in poor combustion, sooting and a hazardous situation. See the drawing to the right showing proper flame appearance.
When testing for proper operation - If an optional thermostat is installed adjust it to its highest temperature setting. Visually determine that main burner gas is burning properly: i.e., no floating, lifting or flashback. Adjust the primary air shutter(s) as required. Check for proper main burner operation at both high and low flame.
Burner Flame Appearance
Soot at Flame Tip
Dark Orange Flame
No Blue Flame Center
IMPROPERLY
BURNING FLAME
Soot above Flame Tip
Ports on Pan
Burner Assembly
BURNING FLAME
No Soot at Flame Tip
Semi-Transparent Yellow Flame
Blue Flame Center
PROPERLY
Figure 24
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
21
Shutter Adjustment Handle
Proper Pilot Flame Appearance
Figure 25
Air Shutter Adjustment
CAUTION: Air shutter is hot while the appliance is operating and should only be adjusted using a heat resistant glove.
The air shutter control lever is located on the bottom of the stove directly to the left of the gas valve. The lever is linked to the primary air shutter on the main burner. The air shutter regulates the amount of primary air the burner receives and, therefore, how clean the stove burns. The air shutter should only be adjusted by a qualified gas technician. The stove should burn for about 15 minutes with the logs installed before adjusting the air shutter. Moving the lever to the left will open the shutter and turn the flames more transparent and blue. Moving the lever to the right will close the shutter and turn the flames more orange.
Quiet Operation
As the appliance is burning, a number of normal operational sounds may be heard. The flow of gas through the gas valve and orifice may make a rushing or whistling noise. If this noise is objectionable, it can be reduced by turning down the flame. Turning down the flame can reduce total heat output by more than 30%. When the blower turns on, the sound of rush­ing air may be heard. The blower sounds may be reduced by adjusting the speed control located on the blower assembly. Also, a slight clicking sound may be heard as the gas valve or blower switch is turned on and off.
Paint Curing
This stove has been painted with Stove Bright high temperature metallic paint. It leaves the factory dry to the touch, but completes the curing process as the stove is used. To cure the paint, burn the appliance four successive times for ten minutes each time with a five minute cool down between each firing. Also some parts of the appliance may be lightly coated with machining oil. Ventilate the house during these first firings as the paint and oil give off carbon dioxide and unpleasant odors. It is recommended that persons sensitive to an imbalance in the indoor air quality avoid the appliance during the curing process.
Optional Wall Thermostat
If an optional wall thermostat is to be installed, install the thermostat per the manufacturers instructions (provided with the thermostat). Failure to follow manufacturers instructions could result in a malfunction. Pay special attention to the thermostat location requirements. If the location requirements are not adhered to the appliance, erratic operation or failure may occur.
CAUTION: The air shutter should never be set so as to make the tips of the flames sooty or create sooting on the viewing glass, logs, or firebox ceiling. If soot begins to form after burning, the air shutter should be opened gradually until the sooting condi­tion stops. Gas quality and gas pressure may vary, which can affect the burning characteristics of the stove.
Shutter Adjustment Handle
Turn the handle to the left to open and to the right to close. Locate in lower compartment to the right of the valve.
Do not mount the thermostat where it may be affected by:
• Radiant heat from this appliance, fireplaces, sun or other heat sources.
• Drafts or dead spots behind doors or in corners.
• Hot or cold air from ducts.
22
Figure 26
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
-
Operating Options
PILOT
OFF
ON
HI
LO
PILOT
Your stove comes equipped with an “On/Off” rocker switch used to turn the burner on and off while the pilot light is on. The switch is a round rocker switch located behind the main control panel door.
A millivolt wall thermostat, or a remote control, can be used to supple­ment the rocker switch. The gas valve is powered by millivolts generated by the pilot assembly. This millivolt system is very sensitive to electrical resistance, therefore, make sure all connections are tight, clean and free from corrosion. Do not splice any millivolt wires. Consult the table below to determine the proper gage of wire for the thermostat or wall switch connections. This table refers to the total length of the wire (out to the switch and back). The thermostat must be a millivolt type. A 24-volt furnace thermostat will not work. Never hook up household current - 120 Volts - to the millivolt system. It is not recommended to hook up any more than two switches to the stove (for example a rocker switch and a wall thermostat). Additional switches may affect the system resistance and increase the chance of the burner not igniting.
Follow the instructions included with the thermostat or remote control for wiring. The thermostat, remote control and rocker switch will turn the burner on and off independently. Be sure to set the rocker switch to the “Off” position when using the thermostat or remote control and set the thermostat or remote control to the lowest temperature when you wish to use the rocker switch only, otherwise one may override the other.
Millivolt Control Schematic
Sparker
Pilot Hood
Thermostat Wire
Wire Size Maximum Length
12 Gage 100 Feet 14 Gage 64 Feet 16 Gage 40 Feet 18 Gage 25 Feet 20 Gage 16 Feet
Millivolt Control System
This stove operates on a millivolt control system. As such, no additional power supply is needed for the stove to heat. The pilot assembly contains a thermocouple that, when heated by the pilot flame, generates electricity (millivolts- mV=1/1000 of a volt) which opens a valve allowing gas to continue flowing to the pilot assembly. The pilot assembly also contains a thermopile that, when heated by the pilot flame, generates electricity that flows to terminal #1 (labeled TPTH) on the gas valve. When the electricity is conducted from terminal #1 through the on/off switch, thermostat, or receiver of the remote control to terminal #3 (labeled TH) on the gas valve, the main burner will ignite.
CAUTION: Label all wires prior to disconnection when servic­ing controls. Wiring errors can cause improper and dangerous operation.
ATTENTION: Au moment de l'entretien des commandes, étiquetez tous les fils avant de les débrancher. Des erreurs de cáblage peuvent entraîner un fonctionnement inadéquat et dangereux.
Pressure Taps
Gas Inlet
Figure 27
Piezo Igniter
Thermocouple
Thermopile
Pilot Assembly
Pilot Gas Line
ON/OFF Rocker Switch, Thermostat, or Remote Thermostat
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Gas Valve
Wiring Terminals
TPTH
1
TP TH
2
Terminal 2
3
Terminal 3Terminal 1
23
MAINTENANCE AND SERVICING
WARNING
Turn off gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance.
CAUTION: Wear gloves and safety glasses for protection while doing required maintenance.
Verify proper operation after servicing.
S'assurer que l'appareil fonctionne adéquatement une fois l'entretien terminé.
CAUTION: Label all wires prior to disconnection when servic­ing controls. Wiring errors can cause improper and dangerous operation.
2. The viewing glass should be cleaned periodically (see Glass Door Cleaning and Maintenance).
3. Should repairs or maintenance of the stove require the disassem­bly of the vent/air intake system, the reassembly and resealing should be completed by a qualified service technician and follow the instructions on Pages 13, 14 and 15 of this manual.
Millivolt and System Checks
Check
Test
A Complete
B Thermopile
C System
To
Test
System
Output
Resistance
See Figure 27 - Wiring Terminals
Connect
Meter
Leads to
Terminals
2 & 3 Closed 100 MV
1 & 2 Open Greater Than
2 & 3 Closed 2.5 Ohms
Thermostat
Connects
Meter Read-
ing
Should Be
or More
325 MV
ATTENTION: Au moment de l'entretien des commandes, étiquetez tous les fils avant de les débrancher. Des erreurs de cáblage peuvent entraîner un fonctionnement inadéquat et
dangereux.
Maintenance Checklist:
The following should only be performed by a qualified service technician.
1. Annual inspection should be made and the following checks performed:
oWhen unit is cool, open glass viewing door and inspect burner for
dirt, soot and lint accumulations and remove if necessary. If exces­sive soot accumulation is present on burner, have a qualified service technician adjust burner for proper combustion.
oClean inside of glass viewing door with gas fireplace glass cleaner.
NEVER attempt to open door or clean glass when unit is hot.
oCheck the hot air outlet vents for lint or other accumulations. Never
block or restrict vent openings or obstruct flow of ventilation air.
oCheck that direct-vent pipe, air intake and flue are open and free of
soot, blockage, or debris.
oCheck gaskets once a year. Gaskets must be tight. Replace if neces-
sary.
oInspect the pilot system for proper flame. NEVER ADJUST THE
PILOT until after the gas pressure has been checked and supply lines have been completely bled (this may take an hour or more when bleeding through the pilot). All pilots are checked and burned at the factory prior to shipment. The pilot adjustment screw is located to the lower left of the flame height control knob.
.25 Adjust the pilot screw to properly size the flames. The flames
should completely surround the thermopile and thermocouple and extend across the main burner tube ports. Be careful not to back the screw out of its threads.
oCheck that the area around the stove is kept clear and is free of
combustible materials, gasoline and other flammable vapors and liquids.
oCheck the millivolt system as per the table on this page.
Proper Pilot Flame Appearance
Figure 28
Vent Pipe Maintenance
Conduct an inspection of the venting system semiannually. Recommended areas to inspect are as follows:
1. Check areas of the venting system which are exposed to the elements for corrosion. These will appear as rust spots, streaks, or, in extreme cases, holes. These components should immediately be replaced.
2. Remove the cap and shine a flashlight down the vent. Remove any bird nests or other foreign material.
3. Check for evidence of excessive condensate, such as water droplets forming in the inner liner and subsequently dripping out at joints. Continuous condensate can cause corrosion of caps, pipe and fittings. It may be caused by having excessive lateral runs, too many elbows, or exterior portions of the system being exposed to cold weather.
4. Inspect joints to verify that no pipe sections or fittings have been dis­turbed and consequently loosened. Also check mechanical supports such as wall straps or plumbers’ tape for rigidity.
24
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Glass Door
Opening and Removing Door
WARNINGS
Do not attempt to substitute the materials used on these doors, or replace cracked or broken glass.
• Handle this glass with extreme care! Glass is susceptible to damage – Do not scratch or handle roughly while reinstalling the glass door frame.
• The glass door(s) of this appliance must only be replaced as a complete unit as provided by the manufacturer. Do not attempt to replace broken, cracked or chipped glass separately.
Do not attempt to touch the front enclosure glass with your hands while the appliance is in use.
Do not use abrasive cleaners. Never clean the glass when it is hot.
Do not operate the appliance with glass removed, cracked or broken.
CAUTION
Swing the front door open to access the two 5/32” screws at the top of the glass frame and remove the two screws. To remove the door, grasp it firmly with both hands and lift it up. The glass door is fragile so it is important to place it in a secure spot until reinstalled. To reinstall the door, the bottom of the door must be inserted in the slot at the bottom of the firebox.
Glass Door Cleaning and Maintenance
Cleaning: Do not remove or clean the glass door when hot. When cool,
the glass may be cleaned with a clean, soft cloth and a household glass cleaner. For cleaning white condensation from the interior glass, use a gas fireplace glass cleaner available from your dealer. Use of caustic or abrasive cleaners may damage the glass. DO NOT spray commercial glass cleaner with ammonia on the door and glass gasket as it may dis­solve the gasket glue.
Repair: If the glass is broken in the glass door, the entire door (metal
frame, gasket and glass) should be replaced as a unit. This replacement glass door is available from your Lennox Hearth Products dealer. Do not use substitute parts or materials. The glass is neo-ceramic and alterna­tive types must not be used.
NOTE: BE CAREFUL NOT TO SPRAY COMMERCIAL GLASS CLEANER WITH AMMONIA ON GASKET AREA OF DOOR. AM­MONIA WILL DISSOLVE GASKET GLUE.
ATTENTION
Ne pas utiliser l'appareil si le panneau frontal en verre n'est pas en place, est craqué ou brisé.
Only doors certified with the appliance shall be used.
Seules des portes certifiées pour cet appareil doivent être utilisées.
CAUTION: DO NOT abuse glass door by striking or slamming shut.
Do not remove glass door while the appliance is hot.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
25
Fuel Conversion
Converting the stove between natural gas (NG) and propane (LP) can be accomplished by either changing the cassette (valve and pilot assembly) or installing a conversion kit (regulator, burner orifice and repositioning the slide orifice of the pilot). Only a qualified service technician should perform the conversion.
Conversion Kit:
Please see instructions provided with conversion kit.
Cassette Removal
CAUTION: Label all wires prior to disconnection when servic­ing controls. Wiring errors can cause improper and dangerous operation.
ATTENTION: Au moment de l'entretien des commandes, étiquetez tous les fils avant de les débrancher. Des erreurs de cáblage peuvent entraîner un fonctionnement inadéquat
et dangereux.
1. Be sure the gas supply is shut off. The electrical supply for the blower should be shut off at the electrical panel before beginning the conver­sion. Disconnect the gas supply from the stove, being careful not to apply pressure to the valve in the process.
2. Remove the log set (see “Log Installation”).
3. Remove the two phillips head screws from the back of the burner.
4. Lift the right end of the burner and slide if off the orifice and shutter tube. Remove the burner from the firebox.
5. Remove the labeled cover through which the valve control knobs protrude by removing the two screws securing it and slide it off the valve knobs.
6. Mark and disconnect wires on valve terminals #1 and #3 connected to the burner on/off switch, thermostat, or remote control. Disconnect the igniter wire from the control panel.
7. From inside the firebox, remove the two allen head screws that fasten the log support in and remove the log support piece.
8. From inside the firebox, remove all three of the allen head screws (see Figures 29 and 30) fastening the cassette to the firebox.
9. Grasp the cassette assembly from below the firebox and lower the front edge away from the firebox.
10.Install the new, converted, or serviced cassette in the reverse order of removal. All surfaces of the cassette must be sealed to the firebox to ensure an air tight seal. Replace damaged gasket.
11.All parts and wires must be correctly reinstalled to ensure safe and proper operation of the unit.
Figure 29
Figure 30
26
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
TROUBLESHOOTING
NOTE: When troubleshooting the gas control system, be sure the external gas shut off valve, located at the gas supply inlet is in the “ON” position.
IMPORTANT: Call your gas supplier or plumber for additional help with any gas control problem. Valve system troubleshooting should only be accomplished by a qualified service technician.
SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION
Thin black coating (soot) forms on the viewing glass, logs, or firebox.
Improper log or ember placement.
Blocked flue.
See Brick Panel, Log Set and Ember Installation.
Check for obstructions in vent pipe, check for proper restrictor setting. See Flue Restric- tors.
Improper air shutter setting.
Humming or whistling coming from fireplace.
A change in flame appearance or burner operation.
Pilot will not light. No gas supplied to unit.
Pilot will not stay lit after carefully following lighting instructions.
Normal operating noise.
Dirt in burner orifice. A change in gas pres-
sure.
Improper ember or log placement.
Air in line.
Defective igniter (no spark at electrode).
The valve control knob is not turned to “pilot” and pushed in.
Pilot flame is not sur­rounding thermocouple.
Thermocouple not generating sufficient voltage.
See Air Shutter Adjustment.
See Quiet Operation. The noise may be reduced by slightly turning the flame down. Turn­ing the flame down will reduce the heat output of the fireplace.
Clean orifice. Have your gas supplier check for correct gas pressure (7” W.C. natural gas; 11” W.C. LP
gas).
See Brick Panel, Log Set and Ember Installation.
Turn on gas.
To purge, hold in control knob in pilot position for 1-2 minutes and light.
Check for spark at electrode and pilot, if no spark and electrode wire is properly connected, replace igniter.
See Lighting Instructions.
Check pilot flame adjustment (see Maintenance and Servicing section).
Check the connection between the thermocouple lead and the valve. Turn control knob to “pilot” and push in and light pilot. While lit, take millivolt reading at lead going into valve’s CPU. Minimum reading should be 17 millivolts. If less, replace thermocouple.
Main burner will not burn.
Air in gas supply line.
Pilot has gone out.
Rocker switch or thermostat wires are defective.
Thermopile may not be generating sufficient millivolts.
Purge air in pilot gas line by holding in control knob at “pilot” and sparking igniter. The air in the line may take up to several minutes to purge.
See Lighting Instructions.
Disconnect rocker switch and thermostat wires at terminals 1 and 3 on valve. Jumper across from 1 to 3 with pilot lit. If burner comes on either rocker switch or thermostat wir­ing is not functioning.
Make sure thermopile is fully engulfed by the pilot flame. Check thermopile with millivolt meter. With pilot lit and the rocker switch and thermostat off, the millivolt reading with the meter connected to valve terminals 1 and 2 should be after 2 minutes at least 325. If the thermopile lead connections are good at terminals 1 and 2 and readings are less than 325, replace faulty thermopile.
27
Wire Harness Diagram
BLOWER
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
ATTENTION: Au moment de l'entretien des commandes, étiquetez tous les fils avant de les débrancher. Des erreurs de cáblage peuvent entraîner un fonctionnement inadéquat et dangereux.
FEMALE SPADE 1/4"
SPEED CONTROL SWITCH
FEMALE SPADE 1/4"
2 PL. FEMALE SPADE 1/4"
MALE SPADE 1/4"
RED 7"
RED 12"
RED 8"
BLK 16"
FEMALE SPADE 1/4"
RING LUG CRIMP
MALE SPADE 1/4"
BLK 6"
GRN 6"
W
H T
6"
STRIP OUTER JACKET 6"
POWER CORD
8'
28
Figure 31
SNAP SWITCH
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
FEMALE SPADE 1/4"
REPLACEMENT PARTS - VISN-25/35 AND SDVSS-25/35
Cat. No. Description
H3136 Cassette Assembly, NG (if LP, also requires 75265
conversion kit) H6034 Burner Assembly H5922 Pilot Assembly, NG or LP H5942 Gas Control Valve, NG (if LP, also requires H5945 LP
Regulator) H5943 Regulator, NG H5945 Regulator, LP H5966 Orifice, Main Burner, #42 NG, 25,000 BTU H5967 Orifice, Main Burner, #34 NG, 35,000 BTU H5964 Orifice, Main Burner, LP #53, 25,000 BTU H5970 Orifice, Main Burner, LP #50, 35,000 BTU H3071 Blower H5875 Blower Snap Switch H5877 Blower Speed Control (rheostat) H5744 On/Off Switch H3119 On/Off Switch Wires H5745 Piezo Igniter H5660 Power Cord H5871 Log Set H5863 Bag of Embers (volcanic stone) H5864 Bag of Rockwool H5870 Brick Panel H5991 Firebox Door w/Glass H5992 Door Assembly Side w/Glass H6011 Flue Restrictor H6012 Sight Obstructor H5918 Door Hinges, 2 per Stove H5894 Spring Handle, Gold H5895 Spring Handle, Nickel
Contact an Lennox Hearth Products dealer to obtain any of these parts. Never use substitute materials. Use of non-approved parts can result in poor performance and safety hazards.
WARNING
Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.
AVERTISSEMENT
Risque de dommages ou de blessures si les pièces ne sont pas installées conformément à ces schémas et ou si des pièces autres que celles spécifiquement approuvées avec cet appareil sont utilisées.
29
ACCESSORIES - VISN-25/35 AND SDVSS-25/35
Product Reference Information
Cat. No. Description Ship.
Weight
55107C VISN 25/35, Direct-Vent Freestanding Gas
Stove
H8402 SDVSS, Direct-Vent Freestanding Gas Stove 189 lb. 24.06 cu. ft.
189 lb. 24.06 cu. ft.
Trim Kits (ref. form #775290M)
Kits Include: Matching Trim for Glass, Louvers and Ash Lip
Cat. No. Model Description
75276 VISN-TRIM-B-G Black Trim/Gold Handle 75277 VISN-TRIM-B-N Black Trim/Nickel Handle 75274 VISN-TRIM-G-G Gold Trim/Gold Handle 75275 VISN-TRIM-N-N Brushed Nickel Trim/Nickel Handle
Ship.
Volume
Controls
Wall Thermostat
Remote Control
H4635 DWTK Wall Thermostat, Digital H0251 RCL-STAT Remote Control, Deluxe Thermostat, DC
(ref. form #750129M)
70005 RT-AC Remote Control, Thermostat, AC
(ref. form #775280M)
Gas Conversion Kits
Cat. No.
75266 VISN-CD-LP to NG Conversion Kit LP to NG (ref. form #775236M) 75265 VISN-CK-NG to LP Conversion Kit NG to LP (ref. form #775245M)
Model
Description
Touch-Up Paint Kit
H8159
TSPK-B
P
T
A
N
I
Touch-Up Paint, Metallic Black (12 oz aerosol)
NOTE: The form numbers referenced are the part numbers of the instruction sheets included in kits.
Orifice Main Burner #36 NG, 33,000 BTU
(converts from standard 35,000 BTU input to optional 25,000 BTU input)
Cat. No. Description
H5966 Orifice, Main Burner, #42 NG, 25,000 BTU
30
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
* L’APPAREIL PRÉUSINÉ EST MUNI D’ÉQUIPEMENT POUR 0-2000 PIEDS (0-610 M). AU CANADA 0-4500 PIEDS (0-1370M).
SAFETY / LISTING LABEL - VISN-25/35 AND SDVSS-25/35
MODEL MODÈLE
Portland
US
Report No. / Número de Rapport
050-S-16b-5
FACTORY EQUIPPED FOR NATURAL GAS. IF CONTROL PANEL CONTRADICTS THIS LABEL, UNIT FUEL TYPE HAS BEEN CONVERTED.
CET APPAREIL EST MUNI D’ÉQUIPEMENT POUR L’USAGE DU GAZ NATUREL. SI L’ÉTIQUETTE DU PANNEAU DES COMMANDES CONTREDIT
MAY BE INSTALLED IN RESIDENTIAL BEDROOMS AND MANUFACTURED (MOBILE) HOMES.
TESTED TO ANSI Z21.88-2005/CSA 2.33-2005 “VENTED GAS FIREPLACE HEATERS”, UL307b, CSA P.4.1-02, AND CGA 2.17-M91. THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES, IF ANY. IF NOT, FOLLOW THE CURRENT ANSI
Z223.1/NFPA 54-LATEST EDITION (USA) OR CAN/CGA B149.1-LATEST EDITION (CANADA)
PART 3280 FOR MOBILE HOMES. ALSO, APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S INSTALLATION INSTRUCTIONS. THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE AND MAY BE INSTALLED IN AN AFTERMARKET, PERMANENTLY LOCATED, MANUFACTURED (MOBILE) HOME WHERE NOT PROHIBITED BY LOCAL CODES. SEE OWNE R’S MANUAL FOR DETAILS. THIS APPLIANCE IS NOT CONVE RTIBLE FOR USE WITH OTHER GASES, UNLESS A CERTIFIED KIT IS USED. DANGER: RISK OF ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT.
IF ELECTRICALLY C ONNECTED, CONNECTIONS AND GROUN DING MUST BE IN ACCORD ANCE WITH LOCAL CODES, IF ANY. IF NOT, FOLLOW THE CURRE NT NATIONAL ELECTRICAL CODE ANSI/NFPA 70-LATEST EDITION (USA) OR CSA C22-1-LATEST EDITION (CANADA).
MAX/MIN INPUT BTUH 0-2,000 FT (0-610 M)*
MANIFOLD PRESSURE (IN. WC)
MIN. INLET PRESSURE (IN. WC)
ORIFICE (DMS) 0-2,000 FT (0-610 M)*
VENT ING: THI S AP PLIANCE MU ST BE P ROPERLY CONN ECTED TO A V ENTING SYS TEM IN A CCORDAN CE WITH THE MANUFACTURER’S INSTRU CTIONS. SEE MANUFACTURER’S INSTALLATION INSTRUCTIONS FOR APPROVED PIPE BRANDS AND PIPE SEALING PROCEDURES. FOR ALTITUDES ABOVE 2,000 FT/610M (IN CANADA 4500 FT/1370M) DE-RATE THE APPLIANCE BY FOUR (4)% FOR EVERY 1,000 FT (405 M).
THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE WITH AIR FILTERS.
MINIMUM CLEARANCES TO COMBUSTIBLES IN INCHES DÉGAGEMENTS AUX COMBUSTIBLES - POUCES
CORNER / POSITION EN COIN
Combustible Wall
10”
CAUTION:
CETTE ÉTIQUETTE, C’EST QUE LE TYPE DE CARBURANT DE CET APPAREIL A ÉTÉ CONVERTI.
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL
RATINGS Model VISION 35 Model VISION 25
*UNIT FACTORY EQUIPPED FOR 0-2000 FT/0-610 M, IN CANADA 0-4500 FT/0-1370 M
ELECTRICAL RATING: 120 VAC, 60 HZ, LESS THAN 2 AMPS
(254mm)
5-5/8”
(143mm)
Mur Combustible
90°
Stove
Poêle
MAXIMUM DEPTH / PROFONDEUR MAXIMUM 35”(889mm)
8-7/8”
(225mm)
10”
(254mm)
HOT WHILE IN OPERATION. DO NOT TOUCH. SEVERE BURNS MAY RESULT. KEEP
VISION™ 35
MANUFACTURED BY / FABRIQUÉ PAR:
LENNOX HEARTH PRODUCTS
PO BOX 987
AUBURN, WA., USA 98071
NATURAL GAS LP GAS NATURAL GAS LP GAS
35,000/23,000 35,000/23,500 25,000/17,500 25,000/18,000
3.5 10.0 3.5 10.0
5.0 11 5.0 11
#34/.111 IN. #50/.070 IN. #42/.093 IN. #53/.059 IN.
ALCOVE DIMENSIONS - DIMENSIONS – ALCOVE
MINIMUM WIDTH / LARGEUR MAXIMUM 51”(1295mm)
MINIMUM HEIGHT / HAUTEUR MAXIMUM 46”(1168mm)
SEE OWNER’S MANUAL FOR OTHER ALCOVE
CLEARANCE CONFIGURATIONS.
RÉFÉREZ VOUS AU MANUEL D’INSTALLATION
POUR TOUT AUTRE DÉGAGEMENT REQUIS.
HEARTH PROTECTION
SEE INSTRUCTION MANUAL.
PROTECTIONS AU PLANCHER : RÉFÉREZ
VOUS AU MANUEL D’INSTALLATION.
CHILDREN, CLOTHING, FURNITURE, GASOLINE AND OTHER LIQUIDS HAVING FLAMMABLE VAPORS AWAY. KEEP BURNER AND CONTROL COMPARTMENT CLEAN. SEE INSTALLATION AND OPERATING
SERIAL
NO.
AND SAFETY STANDARD, TITLE 24 CFR,
ALCOVE OR PARALLEL /
POSITION PARALLÈLE OU
* 16.5” (1295Mm) to sidewall in an alcove * Dégagement des matériaux Combustible pour les murs de côté Dans une alcôve est 16.5 Po (1295mm) De chaque côté.
POSITION DE L'ALCÔVE
Mur Combustible
(51mm)
Stove
*15"
(381mm)
Poêle
Combustible Wall
2"
INSTRUCTIONS ACCOMPANYING APPLIANCE. FOR USE WITH GLASS DOORS CERTIFIED WITH THIS APPLIANCE ONLY. DO NOT OPERATE THE APPLIANCE WITH GLASS REMOVED, CRACKED OR BROKEN. REPLACEMENT OF THE PANEL(S) SHOULD BE DONE BY A LICENSED OR QUALIFIED PERSON.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THE OWNER’S INFORMATION MANUAL PROVIDED WITH THIS APPLIANCE. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER, SERVICE AGENCY OR GAS SUPPLIER.
Part No./ No. Pièce #36242 Rev. B, 2/08
DO NOT REMOVE OR COVER THIS LABEL MADE IN U.S.A.
HOMOLOGUÉ FOYER RADIANT PRÉFABRIQUÉ AU
GAZ -NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE
MAY BE INSTALLED IN RESIDENTIAL BEDROOMS AND MANUFACTURED (MOBILE) HOMES. TESTÉ SELON LA NORME ANSI Z21.88-2005/CSA 2.33-2005 «FOYER RADIANT AU GAZ», UL307B, CSA P.4.1-02, ET CGA 2.17-M91. CET APPAREIL DOIT ÊTRE INSTALLÉ CONFORMÉMENT AUX EXIGENCES DES CODES RÉGIONAUX ET DU CODE D’INSTALLATION
ANSI NFPA 54-DERNIÈRE ÉDITION (ETATS-UNIS), OU CAN/CGA-B149.1-DERNIÈRE ÉDITION (CANADA) LE STANDARD DE SÉCURITÉ EST TITLE 24CFR, PART 3280 . CET APPAREIL DOIT ÊTRE INSTALLER SELON LES SPÉCIFICATIONS DU MANUFACTURIER.
CET APPAREIL DOIT ÊTRE UTILISÉ AVEC LE TYPE DE GAZ INDIQUÉ SUR LA PLAQUE SIGNALÉTIQUE ET PEUT ÊTRE INSTALLÉ DANS UNE MAISON PRÉUSINÉE OU DANS UNE MAISON MOBILE FIXE, LÀ OÙ LES CODES RÉGIONAUX LE PERMETTENT. VOIR LE MANUEL D’ENTRETIEN POUR PLUS DE DÉTAILS. CET APPAREIL NE PEUT PAS ÊTRE CONVERTI POUR L’USAGE AVEC D’AUTRES TYPES DE GAZ À MOINS D’UTILISER UNE TROUSSE DE CONVERSION HOMOLOGUÉE.
DANGER: RISQUE DE CHOC ÉLECTRIQUE. DÉBRANCHEZ L’APPAREIL AVANT D’EN FAIRE L’ENTRETIEN. SI L’ APPAREI L REQUIERT UN BRANCHEMENT É LETRIQUE, LE S RACCORDEME NTS ET LA MISE À LA TERRE DOIVENT ÉTRE
CONFORMES AUX EXIGENCES DES CODES RÉGIONAUX ET DU CODE D’INSTALLATION ANSI/NFPA 70 OU CSA C22-1.
SPÉCIFICATIONS Modèle VISION 35 Modèle VISION 25
ENTRÉE MAX/MIN BTU/HR 0-4500 pi (0-1370 M)*
PRESSION À LA SORTIE (IN. WC/C.E.)
PRESSION MINIMUM D’ENTRÉE DU GAZ (IN. WC/C.E.)
ORIFICE (DMS) 0-4500 pi (0-1370 M)*
SPÉCIFICATIONS ÉLECTRIQUE 120 VCA, 60 HZ, MOINS DE 2 AMPÈRES
CON DUIT: CE T APPARE IL DOIT ÊTRE IN STALLE R SEUL EMENT AV EC UN CO NDUIT D’ÉVAC UATION RECOMMANDÉ PAR LE MANUFACTURIER. TOUJOURS SE RÉFÉRER AU MANUEL D’INSTALLATION.
EN ALTITUDE, AU-DELÀ DE 2000 PI/610 M, (AU CANADA 0-4500 PI/0-1370M) LA CAPACITÉ ÉNERGÉTIQUE DE L’APPAREIL DIMINUE DE QUATRE (4)% POUR CHAQUE 1000 PI (405 M).
CE FOYER RADIANT AU GAZ À ÉVACUATION N’EST PAS CONÇU POUR ÊTRE UTILISÉ AVEC DES FILTRES À AIR.
DANGER:
CET APPAREIL DÉGAGE DES TEMPÉRATURES ÉLEVÉES ET DEVRAIT ÊTRE
GAZ NATUREL GAZ PROPANE GAZ NATUREL GAZ PROPANE
35000/23000 35000/23500 25000/17500 25000/18000
3.5 10.0 3.5 10.0
5.0 11 5.0 11
#34/.111" #50/.070" #42/.093" #53/.059"
POUR LES MAISON MOBILE
INSTALLÉ À L’ÉCART DES ENDROITS TRÈS PASSANTS ET LOIN DES MEUBLES ET RIDEAUX. SURVEILLEZ LES ENFANTS QUI SE TROUVENT DANS LA PIÈCE. GARDEZ LA ZONE AUTOUR DU FOYER EXEMPTE DE MATÉRIAUX COMBUSTIBLES, D’ESSENCE ET AUTRES VAPEURS ET LIQUIDES INFLAMMABLES. MAINTENEZ LE BRÛLEUR ET LE BOÎTIER DES COMMANDES PROPRE EN TOUT TEMPS. VOIR LES MANUELS D’INSTALLATION ET D’ENTRETIEN QUI ACCOMPAGNENT L’APPAREIL. SEUL LE PANNEAU VITRÉ FOURNI PAR LE MANUFACTURIER PEUT ÊTRE UTILISÉ AVEC CET APPAREIL. EN AUCUN CAS, L’APPAREIL NE PEUT ÊTRE UTILISÉ SANS LA VITRE OU AVEC LA VITRE BRISÉE. LE REMPLACEMENT DE LA VITRE DOIT ÊTRE EFFECTUÉ PAR UN TECHNICIEN DE SERVICE QUALIFIÉ.
AVERTISSEMENT: UNE INSTALLATION INADÉQUATE DE MÊME QU’UN AJUSTEMENT, UNE MODIFICATION, UNE RÉPARATION OU UN ENTRETIEN INCORRECTS PEUVENT CAUSER DES BLESSURES OU DOMMAGES À LA PROPRIÉTÉ. RÉFÉREZ-VOUS AU MANUEL D’ENTRETIEN LIVRÉ AVEC CET APPAREIL. POUR DE L’ASSISTANCE, CONSULTEZ UN INSTALLATEUR QUALIFIÉ, UNE ENTREPRISE DE SERVICE OU UN FOURNISSEUR DE GAZ.
DATE OF MANUFACTURE / DATE DE FABRICATION
JAN
FEB
MAR
APR
2008 2010 20112009
2011 2012 2013 2014
NE PAS RETIRER CETTE ÉTIQUETTE Fabriqué aux U.S.A. IGN 08-0710
JANV
FEVR
MARS
AVR
MAY
MAI
JUN
JUIN
JUL JUIL
AUG
AOÛT
SEP SEPT
OCT OCT
NOV NOV
DEC DEC
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
31
Enfoncez légèrement le bouton de contrôle du gaz et tournez-le dans le sens des aiguilles d’une montre à la position “OFF”.
l’allumeur Piézo-électrique doit allumer la veilleuse. Continuez à maintenir le bouton de contrôle dans cette position pendant environ 30 secondes après l’allumage de la veilleuse. Relâchez le bouton de contrôle du gaz qui reviendra à la position initiale. La veilleuse doit
Si le bouton de contrôle du gaz ne revient pas à la position initiale une fois relâché, appeler immédiatement un technicien qualifié ou
Lorsque la veilleuse est allumée, tournez le bouton de contrôle du gaz dans le sens invers des aiguilles d’une montre pour le
Ajustez la flamme et la température souhaitée en tournant le bouton de réglage de la flamme dans les sens des aiguille d’une montre
Thermocouple
Gas Pilot Hood
LIGHTING LABEL - VISN-25/35 AND SDVSS-25/35
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING:
IF YO U DO NOT FOLLOW THESE INST RUCTIONS EXACTLY, A FIRE OR EXPLOSIO N MAY RESULT CAUSING
PROPERTY DAMAGE, INJURY OR LOSS OF LIFE.
CAUTION:
HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN, FURNITURE, GASOLINE AND OTHER LIQUIDS WITH
FLAMMABLE VAPORS AWAY. NEVER OPERATE UNIT WITH GLASS DOOR OFF OR ATTEMPT TO OPEN THE DOOR WHILE HOT.
A. This appliance is equipped with a piezo ignition device to light the pilot. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING, smell around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air
and will settle on the floor. WHAT TO DO IF YOU SMELL GAS:
• DO NOT try to light the appliance.
• DO NOT touch any electric switch; do not use any phone in the building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use any tool. If the knob will not push in or turn by hand, don't try
to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion. D. DO NOT use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance
and to replace any part of the control system and any gas control which has been under water.
OPERATING INSTRUCTIONS
CAUTION: YOUR LENNOX GAS APPLIANCE MUST ALWAYS BE OPERATED WITH GLASS DOOR IN PLACE. STOP! Read the safety information above before proceeding.
1. Open the lower door. Make sure gas supply shut-off cocks are open and ON/OFF Rocker Switch is “OFF”. If equipped with a thermostat, set it to the lowest setting.
2. Turn off all electrical power to the appliance.
3. Push in Gas Control Knob slightly and turn clockwise to “OFF”.
NOTE: Knob cannot be turned from “PILOT” to “OFF” unless Knob is pushed in
slightly. Do not force.
4. Wait five (5) minutes to clear out any gas. If you smell gas, STOP! Follow “B” above. If you don’t smell gas continue.
Locate the pilot by looking at the center bottom of the back log.
5. be seen when the pilot is lit.
6. Turn the gas control knob counterclockwise to the “PILOT” position.
7. Push the knob all the way in and hold in that position. Immediately light the pilot by pressing the igniter button several times until pilot is lit. Continue to hold the knob in for about 30 seconds after the pilot is lit. Release knob and it will pop back out.
Pilot should remain lit. If it goes out, repeat steps 4-8 holding knob in an additional 15 seconds after
pilot is lit.
• If knob does not pop out when released, stop and immediately call your service technician or gas supplier.
• If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or your gas supplier.
8. After pilot is lit, turn gas control counterclockwise to “ON”. Knob can only be turned “ON” if the knob has popped out.
9. To turn burner on, turn “ON/OFF” rocker switch to “ON” or set the thermostat to the desired temperature above room temperature.
10. Adjust the flame height (and heat output) by turning the flame height knob clockwise for reduced flame and
counterclockwise for full flame.
11. Turn on all electrical power to the appliance.
12. Set the blower to the desired air flow after it turns on when the appliance reaches operating temperature.
Blue flame will
Gas Control Knob (pilot/on/off) Bouton de contrôle (veilleuse/ ouverte/fermée)
ON
HI
PILOT
OFF
LO
Flame Height Control Knob
- LO / HI + (Commande De Taille De Flamme)
On/Off Switch /
Interrupteur
Veilleuse à gaz
Thermopile
PILOT ASSEMBLY
Igniter /
Allumeur
Blower /
Ventilateur
Igniter (electrode) Allumeur
TO TURN OFF GAS TO APPLIANCE
1. Turn off the “ON/OFF” rocker switch and/or thermostat (if installed).
2. Turn off electric power to the appliance if service is to be performed.
3. Turn gas control knob clockwise to "OFF". Do not force. This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate
combustion and ventilation air. See Installation and Operation Manual accompanying appliance.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information, consult a qualified installer, service agency or your gas supplier.
Operation of this appliance when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death.
1. To turn off the burner, switch the rocker switch to “OFF” or adjust the thermostat to a setting below room temperature (if installed). The pilot will remain lit for future burner ignition.
Part No./ No. Pièce #36242 Rev. B, 3/08
For complete shutdown: See “TO TURN OFF GAS TO APPLIANCE” above.
SHUTDOWN PROCEDURE
POUR VOTRE SÉCURITÉ, LIRE AVANT L’ALLUMAGE
AVERTISSEMENT:
D’EXPLOSION QUI POURRAIENT CAUSER DES DOMMANGES MATÉRIELS ET CORPORELS POUVANT ENTRAÎNER LA MORT.
DANGER:
RIDEAUX. GARDEZ LA ZONE AUTOUR DU FOYER EXEMPTE DE MATÉRIAUX COMBUSTIBLES, D’ESSENCE ET AUTRES VAPEURS ET LIQUIDES INFLAMMABLES.
A. Cet appareil utilise un système d’allumage par étincelle (allumeur Piézo-électrique) pour allumer la veilleuse. Assurez-vous de suivre rigoureusement les instructions d’allumage de la veilleuse.
B. AVANT D’ALLUMER L’APPAREIL, assurez-vous qu’il n’y a pas d’odeur de gaz près de l’appareil ni près du sol car certains gaz plus lourds que l’air auraient tendance à s’y accumuler en cas de fuite.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• N’ALLUMEZ aucun appareil.
• Ne touchez aucune prise électrique; N’utilisez aucun téléphone dans votre édifice.
• Sortez de la maison. À partir d’un autre endroit, appelez immédiatement votre fournisseur de gaz et suivez les directives.
• S’il est impossible de joindre le distributeur du gaz, appelez les pompiers. C. N’utilisez aucun outil pour tourner ou pousser le dispositif de contrôle du gaz. Si vous ne pouvez le faire manuellement, n ’essayez
pas de réparer l’appareil. Appelez un technicien de service qualifié. Si vous tentez de forcer ou réparer le dispositif de contrôle du gaz vous pourriez encourir un risque d’incendie et/ou d’explosion.
D. N’uti lisez pas cet appareil si une de s es composantes a été émergée dans l’eau . Appelez immédiatement un technicien de service qualifié et reconnu afin qu’il inspecte et remplace au besoin toutes pièces du système qui auraient été en contact avec l’eau.
SI VOUS NE RESPECTEZ PAS RIGOUREUSEMENT LES INSTRUCTIONS CI-DESSOUS, VOUS POURRIEZ ENCOURIR UN RISQUE D’INCENDIE ET/OU
CET APPAREIL DÉGAGE DES TEMPÉRATURES ÉLEVÉES ET DEVRAIT ÊTRE INSTALLÉ À L’ÉCART DES ENDROITS TRÈS PASSANTS ET LOIN DES MEUBLES ET
ALLUMAGE
DANGER: VOTRE APPAREIL AU GAZ LENNOX DOIT ÊTRE OPÉRÉ AVEC DES PORTES DE VERRE. ATTENTION! Lisez les consignes de sécurité ci-dessous avant d’opérer votre appareil.
1. O uvrir la p orte du b as. Assure z-vous q ue l’alim entatio n en gaz es t à la pos ition Fermée “O FF”. Si l ’apparei l est équippé d’un thermostat, placez-le à la température la plus basse.
2. Couper le courant électrique qui alimente l’appareil.
3. NOTE: Le bouton de contrôle du gaz ne peut être tourné de la position “PILOT” à “OFF” sans qu’une légère pression ne soit appliquée.
4. Attendez au moins 5 minutes pour que le gaz qui se trouve dans la chambre de combustion puissse s’échapper. Si vous sentez une odeur de gaz ARRÊTEZ! Référez-vous à la section B ci-dessus. Si vous ne sentez pas d’odeur de gaz, allez à la prochaine étape.
5.
Localisez le pilote au centre dans le bas de la bûche arrière.
allumée.
6. Tournez le bouton de contrôle de gaz dans le sens inverse des aiguilles d’une montre pour le placer sur “PILOT”.
7. Cet appareil de chauffage est equipé d’un système d’allumage par étincelle (allumeur Piézo-électirque), devant être utilisé pour l’allumage de la veilleuse. Poussez complètement le bouton de contrôle du gaz et le maintenir dans cette position. Appuyez immédiatement sur le bouton (allumeur Piézo-électrique) situé à gauche du robinet de contrôle du gaz.L’étincelle produite par
rester allumée. Répétez les étapes 4 à 8 pendant 15 secondes supplémentaires si la veilleuse s’éteind.
• votre distributeur de gaz.
• Si la veileuse ne reste pas allumée après plusieurs essais, tournez le bouton de contrôle du gaz à la position “OFF” et appelez immédiatement un technicien qualifié ou votre distributeur de gaz.
8. placer à la position “ON”. Le bouton de contrôle peut-être tourné à la position “ON” seulement si il n’est plus enfoncé.
9. Pour allumer le brûleur, mettre l’interrupteur à la position “ON” ou ajustez le thermostat à la température souhaitée.
10. pour l’abaisser et dans le sens contraire pour l’augmenter.
11. Allumez l’alimentation électrique de l’appareil.
12. Ajustez le ventilateur au volume désiré lorsque l’appareil aura atteint la température de fonctionnement.
Une flamme bleue est visible lorsque le veilleuse est
POUR COUPER L’ALIMENTATION EN GAZ DE L’APPAREIL
1. Fermez l’interrupteur et/ou le thermostat «MARCHE/ARRÊT».
2. Coupez l’alimentation électrique de l’appareil si vous prévoyez en faire le service.
3. Tournez le bouton de commande du gaz dans le sens des aiguilles d’une montre à “OFF”. Ne le forcez pas. Cet appareil a besoin d’air frais pour opérer sécritairement et doit être installé pour qu’il y ait un apport en air suffisant. Référez-vous
aux manuels d’entretien et d’installation fournis avec l’appareil.
AVERTISSEMENT: Une installation inadéquate, un mauvais ajustement, une altération ou toutes autres modifications inappropriés pourraient entraîner des blessures physiques et/ou des dommanges matériels. Référez-vous au guide d’utilisation fourni avec ce foyer. Pour assistance ou information supplémentaires contactez un installateur qualifié, un agent de service ou un fournisseur de gaz.
Si vous o pérez ce t appare il sans qu’il ne soit co rrectement raccordé à un conduit d’évacua tion, vo us pourr iez risquer d’être empoisonné au monoxyde de carbone (CO) ce qui pourrait entraîner des conséquences grave ou la mort.
1. Po ur arr êter le brûleur, mettre l’interr upteur à la position “OFF” ou ajustez le thermos tat à une tempér ature en de ssous de la température ambiante. La veilleuse restera allumée pour permettre un alummage ultérieur.
Pour un arrêt complet: Consultez la procédure ci-dessus «POUR COUPER L’ALIMENTATION EN GAZ DE L’APPAREIL».
PROCÉDURE D’ARRÊT
IGN 08-0710
32
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
NOTES
33
WARRANTY
Your gas stove is covered by a limited warranty (provided with appliance). Please read the warranty to be familiar with its coverage.
Retain this manual. File it with your other documents for future refer­ence.
PRODUCT REFERENCE INFORMATION
We recommend that you record the following important information about your appliance. Please contact your Lennox Hearth Products dealer for any questions or concerns. For the number of your nearest Lennox Hearth Products dealer, please call 1-800-9-LENNOX.
REPLACEMENT PARTS
See Page 29 for a complete replacement parts list. Use only parts sup­plied from the manufacturer.
Your Stoves’s Model Number __________________________________________ Your Stove’s Serial Number ___________________________________________
Normally, all parts should be ordered through your Lennox Hearth Products distributor or dealer. Parts will be shipped at prevailing prices at time of order.
When ordering repair parts, always give the following information:
1. The model number of the appliance.
2. The serial number of the appliance.
3. The part number.
4. The description of the part.
5. The quantity required.
6. The installation date of the appliance.
If you encounter any problems or have any questions concerning the installation or application of this system, please contact your dealer.
LENNOX HEARTH PRODUCTS 1508 Elm Hill Pike, Suite 108 Nashville, TN 37210 Visit us at www.Lennox.com
The Date On Which Your Stove Was Installed _____________________________ The Type of Gas Your Stove Uses ______________________________________ Your Dealer's Name _________________________________________________ Fuel Type (Check one) cNatural Gas cPropane Gas (LP)
Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.
Printed in U.S.A. © 2007 Lennox Hearth Products
P/N 775222M REV. F 09/2011
34
1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210
Loading...