Lennox P-N 850 User Manual

INSTALLATION AND
LENNOX HEARTH PRODUCTS
OPERATING INSTRUCTIONS
MONTECITO ESTATE™
EPA Wood-Burning Fireplace P/N 850,038M REV. B 02/2007
MODEL
MONTEST
This installation manual will enable you to obtain a safe, efficient and de­pendable installation of your fireplace system. Please read and understand these instructions before beginning your installation.
Do not alter or modify the fireplace or its components under any circum­stances. Any modification or alteration of the fireplace system, including but not limited to the fireplace, chimney components and accessories, may void the warranty, listings and approvals of this system and could result in an unsafe and potentially dangerous installation.
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNINGS
• Hot! Do not touch! The glass and surfaces of this appliance will be hot during operation and will retain heat for a while after shutting off the appli­ance. Severe burns may result.
• Carefully supervise children in the same room as appliance.
• If small children are present in the home, it is recommended that this appliance be fitted with a Firescreen kit. See Page 20 for ordering information.
Listed to standards: ULC-S610 & UL-127 Report No. 304-7213 EPA Cert. No. 609
WARNINGS
• The fireplace cannot be operated without a door. Consult your dealer to select the correct door model.
• Important! To assure proper alignment of glass doors: Install this fireplace in a square and plumb condition, using shims as necessary at sides and/or bottom.
• Install the fireplace only as described in these instructions.
PIMONTEST REV. 1
IMPORTANT! GENERAL SAFETY PRE CAUT IONS . REA D AND UNDERSTAND THESE SAFETY RULES BEFORE YOUR FIRST FIRE.
WARNING
Never leave children unattended when there is a fire burning in the fireplace.
IMPORTANT
When burning wood, use SOLID NATURAL DRY WELL-SEASONED WOOD ONLY. Hardwoods are recommended (soft woods tend to burn very quickly).
• DO NOT burn treated wood, charcoal, coal, trash, card­board, driftwood, woods dipped in tar, Christmas tree greens, pitch, pine tar, creosote, chemi­cal chimney cleaners, flame colorants, polystyrene packag­ing, wood products with syn­thetic binders (i.e. plywood). Plywood, lumber and other misc. materials can produce abnor­mally high temperatures, sput­tering and smoking fires and may contain hazardous chemicals to treat insects and fungus.
• Burning unapproved fuels can produce excessive tempera­tures, beyond the design capa­bilities of the fireplace and may produce excess sparks or may contain hazardous chemicals. Burning unapproved fuels can result in a chimney fire, a house fire, personal injury, death or loss of property.
Never leave your fireplace unat­tended while it is burning.
WARNING
WARNING
To avoid the risk of damaging fireplace materials and increas­ing the risk of fire, do not use the fireplace to cook or warm food.
WARNING
NEVER use gasoline, gasoline­type lantern fuel, kerosene, charcoal lighter fluid, naphtha, engine oil or similar liquids to start or “freshen up” a fire in this fireplace. Keep any flammable liquids a safe distance from the fireplace at all times.
WARNING
The fireplace must be operated with the doors fully opened or fully closed. If the doors are left partly opened, smoke may be drawn into the room. Use optional firescreen when doors are fully opened.
WARNING
Use care when selecting window treatments for windows located near the fireplace. Avoid using combustible flowing window treatments such as curtains on nearby windows that are of sufficient length to be blown in front of an open flame when the
window is opened. Keep any combustible furniture,
materials or decorative pillows at least 48" (1219 mm) from the front fireplace opening.
WARNING
This fireplace has NOT been tested with an unvented or vented gas log set. To reduce risk of fire or injury, do not install a gas log set into this fireplace.
WARNING
Be careful adding wood fuel to the fire or handling fireplace tools such as shovels, tongs or pokers.
WARNING
Never modify or alter your fire­place system in any way. To do so may create a potential fire hazard and void the Limited Warranty.
WARNING
The bottom refractory can be cracked by excessive abuse such as tossing heavy logs onto the grate or gouging with fireplace tools. Exercise caution when adding wood to your fireplace.
WARNING
Neither the manufacturer nor the seller warrants “smoke free” operation nor are we responsible for inadequate system draft caused by mechanical systems, general construction conditions, inadequate chimney heights, adverse wind conditions and/or unusual environmental factors or conditions beyond our control.
Always ensure that the air inlet to the fireplace is free from debris and any other obstructions that can block the entrance of air.
The Montecito Estate™ must be installed with an outside air kit, which is included with fireplace.
WARNING
WARNING
2
CONGRATULATIONS!
In selecting this LENNOX wood-burning appliance you have chosen one of the finest fireplaces available. The Montecito Estate™ is a clean burning EPA certified fireplace that is designed to provide you dependable service as well as warmth and enjoyment for many years to come.
Please carefully read and follow all of the instructions found in this manual. Please pay special attention to the safety instructions provided in this manual. This information will be useful to you now and in years to come, so keep the manual handy and refer to it as needed.
TABLE OF CONTENTS
Safety Rules ......................................Page 2
Introduction ......................................Page 3
Parts Required .................................Page 3
Optional Equipment ........................... Page 3
Operating The Montecito Estate .........Page 3
Fuel ...................................................Page 3
Combustion Control .........................Page 4
Refueling For Best Performance .......Page 5
Smoking – Causes And
Troubleshooting ..............................Page 5
Important Cautions ...........................Page 6
Maintaining Your
Montecito Estate ............................Page 6
Creosote ............................................ Page 6
Chimney Maintenance .......................Page 6
Dealing With A Chimney Fire .............Page 6
Finish Door Casing Care ....................Page 6
Refractory Replacement ....................Page 6
Door Installation ...............................Page 7
Door Adjustment ...............................Page 7
Glass Care - Replacement .................Page 7
Glass Care - Cleaning ........................Page 7
Gasket Replacement ........................Page 7
Fireplace Installation ........................Page 8
Locating The Montecito Estate ...........Page 8
Hearth Extension Requirements .......Page 8
Framing, Facing And Mantel .............. Page 8
Hot Air Ducting Installation ..............Page 10
Gravity Kit .........................................Page 10
Outside Air Kit ..................................Page 12
Chimney System ...............................Page 13
Chimney Installation Notes ...............Page 13
Chimney Installation Instructions ...... Page 14
Offset Chimney Installation ...............Page 15
Angled Wall Radiation Shield ............Page 18
Chimney Support Installation ............Page 18
Chimney Chase And
Multiple Terminations......................Page 18
Masonry Application Instructions .....Page 19
Installation Accessories ....................Page 20
Chimney Components Lists ..............Page 20
Replacement Parts ............................Page 23
Specifications .................................... Page 23
Clearances ........................................Page 23
Warranty ...........................................Page 24
THE FIREPLACE
INTRODUCTION
The Montecito Estate wood-burning fireplace is an energy efficient, heat circulating, closed combustion fireplace. You will receive a lifetime of comfort and enjoyment from your fireplace provided it is installed, maintained and oper­ated properly.
Please read these instructions and retain
this manual for future reference.
Before beginning the fireplace installation,
consult the local authorities to obtain your building permit and check your local building codes. Install the fireplace only as described in these instructions and using only Lennox Hearth Products components.
The Montecito Estate is not intended for use
with a gas log set. Do not use a fireplace insert or any other product with this fireplace unless it is specified by Lennox for use with this appliance. Failure to follow these instructions will void the certification and the warranty of the fireplace and may result in an unsafe installation.
• These appliances are designed to provide supplemental heat to the immediate area only. Therefore, it is advisable to have an alternate heat source when installed in a dwelling.
• These appliances are not approved for Manufactured Home installations.
PARTS REQUIRED
Fireplace model: MONTEST
7” diameter chimney - Model Secure Temp
S-2100+, Nova Temp HT6000+, Secure Temp GX (U.S. only) or ACBI manufactured by Security Chimneys International only, including:
- Chimney lengths
- Elbows (where necessary)
- Associated components as per these installation instructions
..Decorative Doors - Required
....(Order Separately - See Page 20)
Front Facade kit - Required
...(Order Separately - See Page 20)
UZY5 Blower (included in the fireplace).
VRUW Blower Speed Control (included)
Outside air kit (Included w/Fireplace)
OPTIONAL EQUIPMENT
- AC Chimney Adaptor (required if using AC Chimney)
- AC Chimney Outside Air Kit
- Gravity Venting System
- Rigid Firescreen
OPTIONAL EQUIPMENT
Additional Equipment (optional)
- Gravity Venting System
- TUBINOX chimney (or PROJET SS), 7” diameter with adaptor for installation in a masonry chimney.
OPERATING THE MONTECITO ESTATE
Fuel - USE SOLID NATURAL WOOD FUEL ONLY. The Montecito Estate is designed to
work best when fueled with dry seasoned natural wood only. Hardwoods are preferred to softwoods since the energy content of wood is relative to its density. Hardwoods will result in a longer burning fire and less frequent refueling. A moisture content of 15% to 20% (seasoned) is recommended. Wood that has been cut and split and let to dry under a cover for a period of one year will usually meet that criteria. Excessively wet wood will be difficult to burn and will result in lower efficiency, in­creased creosoting and deposits on the glass and in the chimney. Excessively dry wood will burn well but will also have higher emissions and shorter burning time.
Do not burn scrap or garbage, treated wood or wood such as driftwood from the ocean which has been exposed to salt or other chemicals. Salt or chemicals can corrode the firebox and chimney. Do not burn large amounts of paper, cardboard, Christmas tree branches or build­ing construction materials. Intense firing with these materials may overheat the fireplace, causing damage to the unit, a fire or even possibly igniting a chimney fire if the chimney is creosoted.
First Fires Before using the fireplace make sure to re­move the plastic wrapping and EPA label on the door. Remove any glue residue left by the label using mild soap.
Make sure the doors are properly adjusted, thus avoiding color change to finish due to overheating.
The first five or six fires should be small fires of short duration (about 30 to 60 minutes). This will help cure the refractory bricks. The first fires may produce slight smoking and some odor due to curing of the paint and steel and the burning of any dust accumulated on the fireplace which will burn off at this time. It may set off a smoke alarm located in the same room. For this reason the room should be well ventilated for the first few fires.
HEAT OUTPUT
The Montecito Estate is the largest member of the “Dave Lennox Signature Collection” of high efficiency fireplaces. The heat generated from its fire is more efficiently captured and distributed. In spite of the large amount of heat that the
Montecito Estate can deliver, it should not replace the main source of heat in your home. This fireplace will bring extra warmth and ambiance to your home by distributing its heat as describe further in the manual.
3
Cl
o
se
d
C
losed
Ope
n
Ope
n
COMBUSTION CONTROLS
Primary Air & Air Boost Controls
There is no flue damper in the Montecito Es­tate™. As is common with air tight appliance, the combustion air control sets the flow of air entering the firebox. This allows for a more precise control of the fire. The combustion air control is located below the door on the left side. The main source of air (primary air) entering the firebox can be diminished by moving the air combustion control from left to right. The primary air is fully opened when the air control is completely moved to the left. This air com­bustion control should be in the closed position when the fireplace is not in operation. This will minimize air leakage up the chimney.
The combustion air control should be opened before opening the doors to minimize the possi­bility of back draft coming into the room (Figure
1-A) More details are available in Refueling For Best Performance on Page 5.
Time Delayed Air Boost System
The time delayed air-boost system register is located underneath the door handles. Placed in the fully opened position, a timer with a maximum duration of 2 hours is engaged. The register gradually reduces the amount of air injected, allowing for a better start of the fire, whatever the conditions (See sections Building a Fire and Refueling For Best Performance for proper sequence of operation). This allows you to start the fire, set the primary air control to the desired burn level and the fireplace will automatically adjust itself to that level once the fire is fully established (Figure 1-B).
Accelerated Combustion
The maximum heat output for the Montecito Estate is achieved by burning with the door closed and the combustion air opened and pulled out. Through this method, the Montecito Estate can produce up to 80,000 BTU of heat per hour.
However, it will be necessary to reload with wood every one or two hours. This is the least efficient method of burning the Montecito Estate .
Use caution when firing with the combustion air control wide open. Only burn cord wood in this manner. Small dry pieces of softwood and construction scraps will burn very intensely us­ing this method and may damage the firebox.
Figure 1
Combustion Air
Register
(A)
Time Delay
Air-Boost Control
(T.D.A.B.)
Figure 2 -
Accelerated Combustion
Medium Combustion
This is the recommended mode of operating the Montecito Estate and should be the one normally used since it will deposit the least amount of creosote on the glass and in the chimney. The combustion air control must be 3/4 closed. The precise setting will depend on
(B)
many factors, including chimney length and the moisture content of the wood.
For instance, a long chimney will necessitate closing the damper more. To obtain the proper combustion, close the damper completely, then open it about 1/4” to 1/2”. Three medium size pieces of cord wood-burning on a bed of hot coals will generate an approximate heat output will of 35,000 BTU per hour and the loading time will be about every 3-4 hours. Softwoods may be burned using this method but the combustion time will be substantially reduced.
4
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 3 - Medium Combustion
Slow Combustion
When the air combustion control is completely closed, the fireplace is in a slow combustion phase. If the hearth is hot enough, slow com­bustion will not extinguish the fire, but there will be a noticeable change in the flame pattern. The flames will be slow and may appear dirty if the wood is too wet (moisture content of 20% and more).
The unit will burn best with 2-3 pieces of cord wood spaced 1 to 2 inches apart and allowing air to get under the fuel. Criss-crossing or ar­ranging the fuel so that air can get underneath will help the fire to get started easily. The unit should be operated with the air control fully open long enough to get the cord wood well ignited.
REFUELING FOR BEST PERFORMANCE
As the fire burns, air goes up the chimney. This air must be replaced through the outside air duct.
When operating the Montecito Estate, open a nearby window temporarily to check if there is adequate air supply replacement. Occasionally, there may be a small amount of smoking upon lighting the fire, until the chimney heats up but this should not last. If the fireplace continues to smoke it is probably for one of the follow­ing reasons:
Do not allow the wood to burn without flame, since this will produce excessive creosote in the unit. Creosote may accumulate on the glass door. This method of burning should be used
only after operating the Montecito Estate™ with the air control opened to produce a hot fire for about an hour or at medium pace for at least three (3) hours. Slow combustion can be used at night in order to reduce the heat output and to prolong the burn. The loading time will be between 6-8 hours and at this combustion rate, the level of BTU’s is at its lowest.
Figure 4 - Slow Combustion
Building a Fire
A) To start a fire, place several crumpled up
balls of newspaper in the firebox. Place small dry pieces of kindling on top of the paper, criss-crossing the kindling so that there are air spaces in between. The kindling should be placed at the center of the firebox so as to allow for sufficient air circulation.
B) Adjust the primary air control and start the
time delayed air-boost system by pushing the register towards the right. Light the newspaper. Leave the doors partially opened to facilitate the start-up.
C) Once kindling fire is well established, cord
wood can be added. You may set the primary air control to the desire level (see Primary
Air Combustion Control and Air Boost Con­trols section for proper operation of the air
controls).
D) Set the primary control to the desired burn
level. The fireplace will automatically go to that level after the fire is fully established and the air boost is closed.
To reload the Montecito Estate at the end of a combustion cycle, when no flame is visible and there are only ashes left:
A) Completely open the air control level and
the T.D.A.B. (Time Delay Air Boost) level. See Figure 1.
B) Open the doors about 1” and wait 5 seconds
until the air flow has stabilized. Then open the doors completely, put the logs in and close the doors.
C) Set the air control to the desired burn level.
The T.D.A.B will close by itself progres­sively.
To reload the Montecito Estate when the fireplace is still hot with a few visible flames:
A) Open the air control completely. The T.D.A.B
can be set to a lower setting in order to facilitate lighting.
B) Open the doors about 1” and wait 5 seconds
until the air flow has stabilized. Then open the doors completely, put the logs in and close the doors.
C) Set the air control to the desired burn
level.
Notes:
• For spectacular fire and optimization of the fireplace efficiency, we recommend that the wood load be placed as far back as pos­sible.
• It may be necessary to turn off any blower(s) in operation during the refueling process in order to minimise smoking in the room. It is recommended to wait 15 to 30 minutes before turning the blower(s) back on to ensure successful rekindling.
SMOKING – CAUSES AND TROUBLESHOOTING
To reduce the likelihood of smoke coming into the room when opening the door, set the combustion air controls to the left (“Acceler­ated Combustion”) before opening the door. Your fireplace has been designed and tested to provide smoke free operation.
A. The doors are partially opened
When you open the doors, open them com
pletely.
B. Negative pressure in the house C. Fans operating (e.g.: range hood)
These fans draw air out of the house and
may actually cause a negative pressure in the house. Turn off all fans and open a nearby window to determine if this is the cause of the problem.
D. Wet wood
Wet or tarred wood will smoulder and smoke
instead of burn properly.
E. Dirty or blocked chimney
Check to make sure the chimney is clear and
clean.
F. Chimney not long enough
The minimum chimney height is 12 feet not
including the fireplace height. The chimney must extend at least three (3) feet (915 mm) above its point of contact with the roof and at least two (2) feet (610 mm) higher than any roof or wall within ten (10) feet (3 m) of it. When installed with offsets, the mini­mum chimney height is 15 feet. Additional height will increase draft and will decrease the tendency to smoke.
G. Poor chimney draft
With no fire, there should be sufficient draft
to exhaust cigarette smoke introduced under the baffle. Chimneys installed against an outside wall without protection may gener­ate back draft problems which will cause start-up problems. To prevent this, open a nearby window; roll up a piece of paper, light it and hold it in the upper part of the firebox to warm up the chimney. Wait until the draft is sufficient, then start the fire.
-
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
5
IMPORTANT CAUTIONS
A. Do not block the hot air vents to the fire-
place as this will cause the fireplace to overheat.
B. Never use gasoline, kerosene, charcoal
lighter fluid or similar liquids to start or rekindle a fire in this fireplace. Keep all such liquids well away from the fireplace at all times.
C. Do not burn coal. The sulphur in coal will
corrode the firebox.
D. Do not burn driftwood which has been in the
ocean or salt water. The salt will corrode the firebox and chimney.
E. Do not burn wood in the area in front of the
grate.
F. Do not abuse the unit by burning paper, or
cardboard or construction material such as pressed wood, plywood or lumber. Wood protectors, metallic paper, coal, plastic, waste, sulphur and/or oil will damage the fireplace.
G. Do not allow the wood to smoulder or burn
without flame, since this will produce excessive creosote in the unit.
MAINTAINING YOUR MONTECITO ESTATE
Creosote
When wood is burned slowly without a flame, it produces tar and other organic vapors which combine with expelled moisture to form a black deposit called creosote which accumulates on the flue lining. When ignited, this creosote makes an extremely hot fire. If the creosote accumulation is large, a creosote fire in the chimney can damage the chimney and over­heat the surrounding wood framing. Creosote formation in a chimney can be minimized by making sure there is always visible flame burning, avoid smoldering fires and by proper refueling techniques.
Chimney Maintenance
Regular chimney inspection and maintenance combined with proper operation will prevent chimney fires. Keep your chimney clean. Do not allow more than 1/16” creosote build up in your chimney. The amount of creosote will depend on variables such as frequency of use and type of fire. We recommend that you:
A. Initially inspect the chimney system weekly.
From this, you will learn how often it will be necessary to clean your chimney.
B. Have your chimney cleaned by a qualified
chimney sweep. If you wish to clean it yourself, we recommend using a stiff plastic or non-metallic brush. If a metal brush is used, its size should be slightly smaller than the flue to avoid damaging the chimney. Do not use a brush that will scratch the stainless steel interior of the chimney.
C. Do not expect chemical cleaners to keep
your chimney clean. The rain cap can be removed for inspection and/or cleaning of the chimney.
Dealing With a Chimney Fire
Regular chimney maintenance and inspection can prevent chimney fires. If you have a chimney fire, follow these steps:
1.
IMPORTANT: Close the fireplace door and the combustion air controls; this will stifle the fire.
2. Alert your family of the possible danger.
3. If you require assistance, alert your fire department.
4. If possible, use a dry chemical fire extin guisher, baking soda or sand to control the fire. Do not use water as it may cause a dangerous steam explosion.
5. Ensure that sparks and hot embers com ing out of the chimney are not igniting the roof.
6. Do not use the fireplace again until your chimney and fireplace have been inspected by a qualified chimney sweep or a fire depart­ment inspector.
REFRACTORY REPLACEMENT
The intense heat of the fire will normally cause hairline cracks in the refractory brick. These cracks can be minimized by proper curing as described in section First Fires. They will not normally diminish the effectiveness of the refractory brick. If large cracks develop, then the refractory should be replaced. To replace the refractory bricks, follow these steps:
6
5
Figure 5
DOOR FRAME FINISH CARE
Use a glass cleaner and a soft cloth to polish the casing. Do not use abrasives such as steel wool, steel pads or an abrasive polish for they may scratch the frame’s finish.
DISPOSING OF ASHES
Remove ashes only when the fire is out and the ashes are cold (24 to 48 hours after the fire is out).
WARNING
When cleaning the fireplace, the ashes should be placed in a metal container with a tight fitting lid. The closed container
-
of ashes should be placed on a non-combustible floor or on the ground outside the house, pend-
-
ing final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have thoroughly cooled.
1. Remove the side refractory brackets (6)
2. Remove the front refractory bricks (3)
3. Remove the bottom refractory brick (4)
4. Remove the left side refractory bricks (5)
5. Remove the right side refractory bricks (2)
6. Remove the back refractory brick (1)
7. Remove the deflectors (7) above the tubes (Can be removed without removing other bricks for chimney cleaning)
To install the new refractory bricks, follow the above steps in reverse.
7
1
4
2
6
3
6
DOOR INSTALLATION
The doors must be put in place only when the installation of the Montecito Estate™ is completed. All you have to do is fit the male part of the hinge, already on the door, to the female part, which is on the fireplace. To remove the doors, simply pull them up from the hinges. The door adjustment has been set at the factory. If the fit is still not perfect, you can adjust the door using the hinge screws (See Figure 7-1)
Figure 6 -
Door Installation
1
2
Figure 7
GLASS CARE
Glass Replacement
The glass used for the Montecito Estate is a high temperature ceramic glass (1,400° F). If the glass breaks or cracks, it must be replaced with an identical ceramic glass. Tempered glass or ordinary glass will not withstand the high temperatures of the Montecito Estate . Replacement glass should be purchased from a Security Chimneys International dealer (see “Replacement Parts” on Page 22).
DOOR ADJUSTMENT
The doors may need to be adjusted to be completely airtight. The gaskets’ air-tightness can be adjusted using the adjustment screw located on the right side of the fireplace facade (An Allen key #1/8 – not supplied - will be necessary for this adjustment) (see Figure 7-2).
Checking Door Seal
A one-inch strip of paper may be used to perform a test of the integrity of the door seal. Close the door on the paper in at least eight points. It is normal to feel only a slight amount of friction. The door gasket does not need to be “tight” in all areas, since a small amount of leakage is not hazardous or detrimental to the performance of your fireplace.
WARNINGS
• Use only a Lennox Hearth Products glass doors, specifically designed for the Montecito Estate fireplace.
• The fireplace cannot be operated without a door. Consult your dealer to select the correct door model.
• Important! To assure proper alignment of glass doors: Install this fireplace in a square and plumb condition, using shims as necessary at sides and/or bottom.
Do not operate the unit with cracked or broken glass.
Glass Cleaning
The Montecito Estate is designed to keep the glass clean under normal operating conditions. If the Montecito Estate is operated continuously with the combustion air controls closed, the glass will tend to get dirty unless the fuel, firebox and glass are maintained at hot temperatures (see section Refueling For Best Performance). To clean the glass, there are a number of specially designed cleaners to remove creosote. Your authorized Lennox Dealer can recommend a suitable cleaner. Regular household glass cleaners will not clean creosote. Do not use abrasives such as steel pads, steel wool or oven cleaner as they will scratch the glass.
Gasket Replacement
Remove the doors from the unit (see section Door Installation) and lay them on a clean nonabrasive surface. To replace the gasket, first remove all of the old gasket and gasket cement. Make sure that the surface is totally clean before applying new cement (a high temperature silicone caulking rated at 500° F (260° C), is suitable) or adhesion problems may result. Apply gasket cement to the gasket channel and install the new gasket. This replacement part is available from your Lennox Dealer in the following dimensions:
Gasket Part # Length Qty Dimensions
Around the glass
On the door frame
Between the doors
Table 1
PR-SR-1685C 61-3/4” 2 1” width
x 3/16” thick
PR-SR-1825I 48-3/8” 2 3/4” diameter
PR-SR-1823J 17-5/8” 2 5/8” diameter
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
7
FIREPLACE INSTALLATION
Locating The Montecito Estate™
The best location to install your fireplace is determined by considering the location of windows, doors, and the traffic flow in the room where the fireplace is located, allowing space in front of the unit for the hearth extension and the mantel, and taking into consideration the location of the hot air ducts (optional), outside air kit and chimney. If possible, you should choose a location where the chimney will pass through the house without cutting floor or roof joists (see fireplace dimensions on
Pages 8 & 9
).
Usually, no additional floor support is needed for the fireplace. The ad­equacy of the floor can be checked by first estimating the weight of the fireplace system. Weights are given in the appendix. Next, measure the area occupied by the fireplace. Note the floor construction and consult your local building code to determine if additional support is needed.
Figure 9
Fireplace
Tile or Marble
Minimum 1” Cement Board
2” x 4” Framing
The Montecito Estate may be installed directly on the floor or on a raised base and a minimum of 80” measured from the base of the appliance to the ceiling is required.
Facade Installation
Install the Facade per instructions provided in Facade Kit (ordered sepa­rately - see Page 20).
Hearth Extension Requirements
The Montecito Estate may be installed directly on a combustible floor; however, the combustible floor in front of the fireplace must be covered with one inch (1 in) of non-combustible support material (cement board, cement block or other) before applying the finish material (tile, marble, stone, etc). See Figure 8.
Hearth Extension Requirements
Area where wood Mantel can be installed
24”
Framing, Facing And Mantel
The construction of the framing, facing, and mantel must be in accordance with the standards and the following illustrations (Figures 10 & 11):
A. Frame the fireplace using 2” x 3” or heavier lumber.
B. WARNING: Combustible materials cannot be used in the space
directly above the fireplace, except for the studs above the fa­cade that support the facing and mantel. This area must remain empty for a height of 80” (2,032 mm) measured from the base of the appliance.
C. Frame the fireplace with vertical studs at the sides of the fireplace run-
ning from floor to ceiling (see Figure 10). If combustible facing is to be used, position the studs back, from the front edge of the fireplace (a space that is the thickness of the facing material, so that the fac­ing can be installed flush with the fireplace facing). Frame headers between the vertical studs only as follows:
- Place 2” x 3” or 2” x 4” headers, only along the upper part of the front, side and back faces (some codes may require a 2” x 6” on an outside bearing wall). Do not put wood or any combustible material within the area above the fireplace except on the front facing.
- Place headers only as required to support the facing and man tel.
D. WARNING: The fireplace must not be in contact with any insula-
tion or loose filling material. Cover the insulation with Drywall panels around the fireplace.
-
56” Min.
COLD CLIMATE INSTALLATIONS
Climates where temperatures will fall below 32° F (0° C).
24”
Hearth
4”
46-5/16”
45 Deg.
16”
The heating performance of the appliance will vary depending upon the level of insulation, house design, how the appliance is operated, etc.
If this fireplace is being installed in a cold climate, it is especially important to seal all cracks around the fireplace and wherever cold air could enter the room with noncombustible material. Also, the outside air inlet duct should be wrapped with noncombustible insulation to minimize the
Non-Combustible Material
Figure 8
8
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
formation of condensation. Do not place insulation materials directly against the chimney sections. We recommend that you use the insulated wall radiation shield since it will maintain the home’s thermal barrier. AC chimney is NOT recommended in cold climates.
7 Ft. Min.
Attic Radiation Shield
Roof Support
Storm Collar
Flashing
Drywall or Any Rigid Material
2” x 4”
1/2” Plywood
6’ 8” Min.
Firestop
* Floor Ceiling
Wall
* Floor Ceiling
Wall
Fireplace
Optional Insulation In Outside Walls Of Chase
Solid Continuous Surface
Outside Base
Insulation (Thermal Barrier)
8'
Level
Header
B
A
F
7/8”
11-1/8”
16-1/4”
26-1/8”
1”
1-5/32”
26-1/4”
10-1/4”
41-3/4”
49-3/8”
46-1/4”
43-1/4”
37”
31”
15”
7”
4-1/4”
28-1/2”
5-5/8”
20-1/8”
28-1/2”
5-5/8”
10-3/8”
3”
OUTSIDE CHASE
G
C
Back Wall of Chase/Enclosure Including Finising Materials if any
Rough Framing Face (Unfinished Shown)
* Zero Clearance From Back Spacer to Wall
CORNER INSTALLATION
D
Insulated Chase Construction
29-1/2”
J
7’
Min.
B
Rough Framing Face
(unfinished shown)
FRAMING DIMENSIONS
Fireplace Opening Width
A 46-3/8” 1178 mm
B 49-1/2” 1257 mm
C 42-3/4” 1086 mm
D 20-7/8” 530 mm
E 93-7/8” 2384 mm
F 47” 1194 mm
G 27-3/4” 705 mm
J 66-3/8” 1686 mm
23-3/4”
E
Note: Floor and wall below the
2” x 3”
Min.
attic must be insulated using the same
Plywood
insulation.
Notes
G
A
Due to Lennox' ongoing commitment to quality, all specifications, ratings and dimensions are subject to change without notice.
All framing dimensions calculated for 1/2" dry wall at the fireplace face. If sheathing the chase or finishing with other thickness materials, calculations will need to be made.
* The fireplace must not be in contact with any insulation or loose filling material. Cover the insulation with Drywall panels around the fireplace.
* Total depth is 25 inches including the
back spacer minus 1/2 inch for drywall to be flush with the facing.
• Must have the same firestopping resistance as adjacent wall.
• Must have the same insulation as adjacent ceiling.
• Follow local rules regarding fram
-
ing construction.
Figure 10
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 11
9
FACING
... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... .. ... ..
IMPORTANT
The facade must be removable once installed. The facade is designed to overlap any facing material installed on the front of the fireplace. If thicker material is installed, use the facade as a template and make sure it can be easily removed for servicing.
1. Combustible material must be installed flush with the fireplace. It may not project in front of and on the fireplace (i.e. the steel facade of the fireplace) (Figure 14).
2. Non-combustible materials such as brick, stone or ceramic tile may project in front of and onto the fireplace facing (Figure 13).
Mantel & Facing
Mantel
56”
Rock Board or Other
Noncombustible Facing
Figure 13
Only non-combustible material should be superposed or project­ing over the front of the fireplace.
(Side View)
Drywall
2” X 3” Min.
Spacer
Fireplace Blower
The fireplace comes equipped with a heat acti­vated blower. It is located in the bottom of the fireplace, towards the back. It uses 120 V and must be connected to the main electrical circuit by a qualified electrician. For connection, use the electrical box supplied with the unit located on the bottom right corner of the fireplace.
If you wish to adjust the blower speed, the variable speed control (VRUW) provided must be installed in line with the wiring. Again, use a qualified electrician for installation.
If the blower requires servicing,
1- Remove the doors and decorative facade. 2- Remove the screw located below the blower
motor that holds it to the back of fireplace.
3- Pull the blower out of the unit through the
square hole located in the front bottom right corner.
MANTEL & FACING
The mantel must be installed at least 56” (1143 mm) above the base of the fireplace (Figure 13).
Fireplace Frame Section
(Top View)
3
5
3
7
10
1
2
6
1
2
1. Fireplace
2. Front of fireplace
3. Wood frame (2” x 3” min)
4. Drywall
5. Tiles
6. Rock board or other
7. Brick
Figure 12
HOT AIR DUCTING INSTALLATION
The Montecito Estate™ is approved for use with a Gravity Kit:
50”
Min.
Gravity Kit
The gravity kit is designed for double hot air outlets and includes: (See Figure 16)
- 2 telescopic lengths 8” I.D.
- 2 90º elbows 8” I.D.
- 2 hot air outlet kits (grill and frames)
- 2 adaptors
4
Figure 14
Noncombustible Facing
Drywall
2” X 3” Min.
4
Spacer
See Gravity Kit Accessories on Page 20.
Only the blower available with the fireplace can be used with the gravity kit.
For safe installation, the gravity kit must meet the following requirements:
Minimum height* 68” (1,727 mm) Maximum length See Figure 17
* The height of the louver must be measured
from the base of the Montecito Estate to the middle point of the louver.
Figure 15
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Rain Cap
Grill
Figure 16
Frame
Flashing Collar
Flashing
Attic Radiation Shield
Roof Support
Firestop
6-1/2” Min. (to ceiling)
68” Min.
56” Min.
Non-Combustible Flameproof Facing
When installing the double outlet system, the hot air outlets can be installed in the same room as the fireplace, or one or both of the outlets can be installed in adjacent or upper rooms. Installing the ducts at dif­ferent elevations will tend to exhaust more heat out of the higher outlet
(Figure 17).
WARNING: The outlet grills should not be installed facing up-
Outlet Grill
ward through a floor. Danger of burns can result if grills in floor are stepped on.
10’ Max.
Outlet Grill
Maintain at least 6-1/2” (160 mm) clearance from the outlet grill framing to a combustible ceiling, side wall or mantel.
13” x 13”
10’ Max.
Figure 17
Figure 18
The duct system must be installed respecting the following:
1. Remove the plates closing up the 8” dia. holes on top of the fireplace. Then, cut the insulation in order to obtain two 8” dia. openings. Fix the adaptors on the fireplace openings by turning clockwise (Figure
16).
2. Maintain at least a 2” (50 mm) clearance between the ducts and any combustible material; the required hole size is 13” x 13” (330 mm x 330 mm).
Exception #1: For the grills, the framing can be 10-3/4” x 10-
3/4” (275 mm x 275 mm) to provide the clearance as required by the integral spacers on the double outlet duct system.
3. The maximum number of elbows in a run of duct is two.
4. Maintain at least 6-1/2” (160 mm) clearance from the outlet grill framing to a combustible ceiling, side wall or mantel.
5. When traversing a combustible wall or floor, a firestop must be installed at the wall or floor penetration. The hole size must be 13” x 13” (330 mm x 330 mm)
6. Do not connect the hot air ducts to a central heating system. Malfunc tion of the heating system’s blower will cause the fireplace to overheat. A furnace duct is only single wall and not double wall as is required
for the Montecito Estate™ hot air exhaust.
7. Use only Security Chimneys International grills and components as described in this manual. Other grills or registers may be too restric­tive and may overheat the fireplace or ceiling.
8. Do not use insulated flexible ducts as they will overheat.
9. Do not use tees or any other components than the ones specifically listed here.
10. Never allow the ducting to pitch down as hot air will be trapped creat­ing a fire hazard. Never route the ducting downwards.
11. The hot air outlet grills must be installed with the louvers pointing downwards in order to prevent overheating adjacent ceilings.
-
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
11
OUTSIDE AIR KIT
It is mandatory to install an outside air connection to the Montecito Estate™. The following components are required and are included with the fireplace:
- Outside air kit long)
- 4” Adaptor for fireplace connection
(includes 40 inch flex that goes up to ten (10) feet
Outside Intake
OUTSIDE CONNECTION
Aluminum Tape
Plastic Cover
Outside Air Installation
The outside air assembly may be installed according to the following requirements:
A) Duct length should be kept to a minimum. The maximum length of a
4” interior diameter (100 mm) insulated flexible duct is 20 feet (6.1 m). The duct can be extended to a maximum of 40 feet (12 m) using a 6” interior diameter (150 mm) insulated flexible duct (See note below).
B) The air intake register must not be installed more than ten (10) feet
(3050 mm) above the base of the fireplace.
C) The fresh air must come from outside the house. The air intake must
not draw air from the attic, basement or garage.
D) The air intake should be installed where it is not likely to be blocked by
snow or exposed to extreme wind and away from automobile exhaust fumes, gas meters and other vents.
E) The duct and register may be installed above or below floor level.
Make a 4-1/4” (110 mm) hole in the outside wall of the house at the chosen location. From outside, place the outside air register in the hole (open side down) and fasten the register to the wall with screws as shown (see
Figure 19
). Slip the pipe into the insulated sleeve. Place the insulated
pipe over the register tube and over the fireplace’s outside air connector (see Figure 20). At each end, carefully pull back the insulation and plastic cover exposing the flexible pipe. Using the aluminium tape provided, wrap the tape around the joint between the flexible pipe and the air inlets. Carefully push the insulation and plastic cover back over the pipe. Using aluminium tape, fasten the plastic cover in place.
Screw
Opening Facing Down
Wall
Figure 19
Plastic Cover
Insulation
Figure 20
Flexible Pipe
Insulation
Aluminum Tape
OUTSIDE AIR CONNECTION TO THE FIREPLACE
Fireplace Connection
Aluminum Tape
Fireplace
Flexible Pipe
Aluminum Tape
NOTE: We recommend not to exceed 20 feet of 4” flexible pipe. If you require a longer length we recommend that you use a 5” diameter flex­ible pipe for the complete run up to 30 feet and a 6” diameter pipe for a run of up to 40 feet.
12
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
THE CHIMNEY SYSTEM
Chimney Installation Notes
1. If possible, install an interior chimney as it will provide better per­formance. In areas with continuous temperatures below 18°C (0°F), the use of an exterior chimney increases the likelihood of operating problems such as low draft, high rate of creosoting, and poor start-up characteristics. Exterior chimneys are also prone to down-drafting and flow reversal. Installations which are located on lower floors in the house, such as in a basement, in combination with an outside chimney, are especially prone to flow reversal.
2. The fireplace model MONTEST
may be installed only with Security Chimneys International Ltd 7” dia. chimney systems model Secure Temp™ S2100+ / Nova Temp™ HT6000 / Secure Temp GX (U.S. only) or ACBI.
3. A chimney venting a fireplace shall not vent any other appliance.
4. The minimum chimney height is 12 feet (3.7 m) excluding the fire­place.
8. A rain cap must be installed on top of the chimney. Failure to install a rain cap may cause corrosion problems.
9. Cut and frame square holes in all floors, ceilings, and roof that the chimney will go through to provide a 2” (50 mm) clearance between the chimney and any combustible materials. Do not fill this 2” space with insulation or any other combustible material.
10. Portions of the chimney which may extend through accessible spaces must be enclosed to avoid contact with combustible materials or damage to the chimney.
11.When offsets are used, the pipe may not penetrate a ceiling or floor unless it is running vertical (no 30° offsets).
two (2) feet Min.
5. All chimney installations must include at least one support in order to be able to take any lateral load. The maximum chimney length that can be supported by the fireplace is nine (9) feet (2.75 m) for Secure Temp S2100+ / Nova Temp HT6000+ / Secure Temp GX and 26 feet (8m) for ACBI chimney. In altitude, add 18” (450 mm) to the chimney for every 2,000 feet (600 m) above sea level.
6. The chimney must extend at least three (3) feet (915 mm) above its point of contact with the roof and at least two (2) feet (610 mm) higher than any wall, roof or building within ten (10) feet (3 m) of it (Figure
21).
7. If the chimney extends higher than five (5) feet (1,500 mm) above its point of contact with the roof, it must be secured using a roof brace.
Figure 21
ten (10) feet
three (3) feet Min.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
13
CHIMNEY INSTALLATION INSTRUC­TIONS
1. Cut and frame the holes in the ceiling, floor and roof where the chimney will pass (see Figure 22). Use a plumb bob to line up the center of the holes. The sizes are indicated in Table 2 for the floor and ceiling holes and Table 3 (Page 15) for the roof holes.
S2100 / HT6000+
Solid Packed Pipe
Attic Radiation Shield
ACBI
Air Cooled Pipe
Attic Radiation Shield
CHIMNEY MODEL SQUARE HOLE
Secure Temp™ S2100+ Nova Temp™ HT6000+
Secure Temp GX
ACBI: Ceiling
(1” clearance)
Wall
Note: See Table 3 for Sloped Roof Framing
SIZE OPENING
15 in (380 mm)
15 in (380 mm) 17 in (432 mm)
Table 2 - Flat Roof Framing
Figure 22 - Roof Framing
From below, install a firestop in each ceiling/floor separation through which the chimney will pass. At the attic level, install an attic radiation shield from above (Figures 23a & 23b).
2. For Secure Temp S2100+ / Nova Temp HT6000+ / Secure Temp GX chimneys, place the first chimney length on the fireplace. To lock it in place, turn 1/4 of a turn clock­wise. With the ACBI chimney, you must use a starter section before installing the first chimney length (Figure 24). Continue installing chimney lengths making sure to lock each length in place.
3. Every time the chimney passes through a ceil ing or a wall, install the appropriate firestop. When you reach the desired height, install the roof support (Refer to instructions included with the support). For an ACBI chimney use an universal support AC10SU.
4. Put the roof flashing in place and seal the joint between the roof and the flashing with roofing pitch (see Figures 25 & 26). For sloping roofs, place the flashing under the upper shingles and on top of the lower shingles. Nail the flashing to the roof, using roofing nails.
5. Place the storm collar over the flashing, and tighten it with the bolt supplied. Finally, seal the joint between the storm collar and the chimney, using silicone caulking.
6. Install the chimney cap.
Figure 23a
CHIMNEY INSTALLATION
MODEL ACBI
Optional Chimney
-
Outside Air Intake
Outside Combustion Air Kit
Figure 24
Firestop
Radiation Shield
Figure 23b
Rain Cap
Collar
Flashing
Attic Radiation Shield
Firestop
Universal Support
ACBI Starter Section ACBI7SB or ACBI7SB30
Note: Outside air kits must be installed for both fireplace and ACBI chimney.
14
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
CHIMNEY MODEL ACBI
Chimney
Collar
Flashing
Figure 25
Figure 26
Roof Down Slope Hole Size
DEGREE OF SLOPE Secure Temp™ S2100+
Nova Temp™ HT6000+
Secure Temp GX
Roof Pitch 7” 7”
0 * 15” (380 mm) 15” (380 mm)
2/12 15-3/8” (390 mm) 15-3/8” (390 mm)
4/12 16-1/8” (410 mm) 16-1/8” (410 mm)
6/12 16-7/8” (430 mm) 16-7/8” (430 mm)
8/12 18-1/4” (465 mm) 18-1/4” (465 mm)
10/12 19-5/8” (500 mm) 19-5/8” (500 mm)
12/12 21-3/8” (545 mm) 21-3/8” (545 mm)
ACBI
Table 3 * Cross Slope Hole Size
OFFSET CHIMNEY INSTALLATION
After reaching the location requiring the elbow, proceed as follows. The minimum chimney height when using elbows is:
Minimum Chimney Height When Using Elbows
Fireplace Model MONTEST
Chimney Model Secure Temp S-2100+ / Nova Temp HT6000+ / Secure Temp GX / ACBI
Vertical Installation 3.66 m (12’)
Two (2) Elbows 4.57 m (15’)
Four (4) Elbows 5.18 m (17’)
Table 4
After reaching the location requiring the elbow, proceed as follows:
Secure Temp S2100+ / Nova Temp HT6000+ / Secure Temp GX Chimneys
1. Install the first elbow; turn it in the required direction. Fasten it to the chimney with the three (3) 1/2” (12 mm) metal screws provided with the elbow.
2. Install the necessary chimney lengths to achieve the required offset. Lock the chimney lengths together: it is recommended to use three (3) 1/2” (12 mm) screws. If the offset length is made of two (2) chimney lengths or more, use an offset support halfway up the offset. If penetrating a wall, install a wall radiation shield (see Figures 29 & 30).
3. Use another elbow to turn the chimney vertically. Secure the elbow, using three (3) 1/2” (12 mm) screws (provided with the elbow).
4. Use a plumb bob to line up the center of the hole. Cut a hole for the chimney in the ceiling/floor. Frame this hole as described previously (refer to Chimney Installation
Instructions on Page 14).
5. From below, install a firestop (See Figure 23a).
6. A support (XST+ or XSO+) must be used on the first 15’ section (5 m).
7. Continue with the regular installation.
ACBI Chimney
1. Install the first elbow. Turn it in the required direction. To lock it in place, turn 1/8 of a turn. Fasten the straps attached to the elbow to the surrounding frame, using nails or drywall screws (Figure 28).
2. Install the necessary chimney lengths to achieve the required offset. Lock the chimney lengths together. If penetrating a wall, use a wall radiation shield.
3. Use another elbow to turn the chimney vertically. Lock it to the chimney. Fasten the straps attached to the elbow to the surrounding framing using nails or drywall screws.
4. Use a plumb bob to line up the center of the hole. Cut a hole for the chimney in the ceiling. Frame this hole as described previously.
5. From below, install a firestop (see Figure
23b).
6. Continue with the regular installation.
Note:
Must return to vertical before penetrating ceiling or floor.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
15
Offset Dimensions
B
Total Height
A
Chimney Elbow
GX
S2100+
HT6000+
7”
Canada
Chimney Elbow Offset &
15º
ACBI
7”
30º
Note: With the ACBI chimney, a starting length of 6” high must be used on top of the fireplace before installing.
15º
30º
45º
Only
Offset &
Height
A
B
A
B
A
B
Height
A
B
A
B
8” 12” 18” 24” 36” 8” & 36” 12” & 36” 18” & 36” 24” & 36” 36” & 36”
3”
(76 mm)
20-3/4”
(527 mm)
7-1/2”
(191 mm)
16-1/2”
(419 mm)
10”
(254 mm)
17-9/16”
(446 mm)
--- 12” 18” 36” 48” --- 12” & 48” 18” & 48” 36” & 48” 48” & 48”
----
----
----
----
----
----
----
----
4-1/4”
(108 mm)
24-1/4”
(616 mm)
9-1/2”
(241 mm)
20-1/4”
(514 mm)
12-3/4”
(324 mm)
20-7/16”
(519 mm)
One Length Between Elbows Two Lengths Between Elbows
5-1/2”
(140 mm)7”(178 mm)
32-1/4”
(819 mm)
10-1/2”
(267 mm)
30-1/8”
(765 mm)
5-3/4”
(146 mm)
29-1/2”
(749 mm)
12-1/2”
(318 mm)
26-1/4”
(667 mm)
17”
(432 mm)
24-5/8”
(625 mm)
38”
(965 mm)
13-1/2”
(343 mm)
35-3/8”
(899 mm)
7-1/4”
(184 mm)
34-3/4”
(883 mm)
15-1/2”
(394 mm)
32”
(813 mm)
21-1/4”
(540 mm)
28-7/8”
(733mm)
11-1/2”
(292 mm)
55-1/2”
(1410 mm)
22-1/2”
(543 mm)
51”
(1295 mm)
Horizontal Offset
10-1/4”
(260 mm)
(1143 mm)
21-1/2”
(546 mm)
43-1/2”
(1105 mm)
29-3/4”
(755 mm)
37-3/8”
(949 mm)
(375 mm)
(1702 mm)
(724 mm)
(1559 mm)
45”
14-3/4”
67”
28-1/2”
61-3/8”
12-1/4”
(311 mm)
51-1/4”
(1302 mm)
25”
(635 mm)
50-1/2”
(1383 mm)
34-11/32” (872 mm)
42”
(1067 mm)
----
----
----
----
----
----
----
----
Two Lengths Between Elbows
13-1/4”
(337 mm)
54-3/4”
(1391 mm)
27”
(686 mm)
54-1/4”
(1378 mm)
37-5/32”
(949 mm)
44-3/4”
(1137 mm)
17-1/2”
(445 mm)
77-1/8”
(1959 mm)
33-3/4”
(857 mm)
70-1/2”
(1791 mm)
14-3/4”
(375 mm)
60”
(1524 mm)
30”
(762 mm)
60”
(1524 mm)
41-13/32”
(1052 mm)
49”
(1245 mm)
19”
(483 mm)
82-7/8”
(2105 mm)
36-3/4”
(933 mm)
75-5/8”
(1921 mm)
16-1/4”
(413 mm)
65-1/4”
(1657 mm)
33”
(838 mm)
65-3/4”
(1670 mm)
45-21/32”
(1160 mm)
59-9/32”
(1353 mm)
23-5/8”
(600 mm)
100-1/4”
(2318 mm)
45-3/4”
(1162 mm)
91-1/4”
(2318 mm)
19-1/2”
(495 mm)
75-1/2”
(1918 mm)
39”
(991 mm)
77-1/2”
(1969 mm)
54-1/8”
(1375 mm)
61-3/4”
(1568 mm)
26-3/4”
(679 mm)
111-1/8”
(2823 mm)
51-3/4”
(1314 mm)
101-5/8”
(2581 mm)
16
Figure 27
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
OFFSET CHIMNEY INSTALLATION
Figure 28
Straps
Support
Straps
Chimney ACBI
ACBI Starter Section
OFFSET CHIMNEY INSTALLATION WITH WALL PENETRATION
Rain Cap
Figure 29
Collar
Roof Support
Roof Flashing
Outside Wall
Offset Support
Framing 2” x 3”
Insulated Wall Radiation Shield
Note: In cold areas it is recommended to protect the chimney in a insulated chase.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
17
ANGLED WALL RADIATION SHIELD (XRSMI30 and AC10RSMI30)
For roof support installation, refer to the instructions provided with the support.
When traversing a combustible wall with the chimney at a 30º or 45º angle, an angled firestop or wall radiation shield must be installed. Only one is required.
Note: 45º angle for Canada only (XRSMI45).
In cold climate locations (climates where temperatures will fall below 32º F / 0º C), we recommend that you use the insulated wall radiation shield since it will maintain the home’s thermal barrier.
XRSMI30 and AC10RSMI30
(XRSMI45 - Canada Only)
Chimney Model (7” dia). Angle Hole Size
Secure Temp™ S2100+
Nova Temp™ HT6000+
Secure Temp GX
Secure Temp S2100+
Nova Temp HT6000+
(US only)
ACBI 30º
30º
45º
Canada only
15” x 38-1/4”
(380 mm x 972 mm)
15” x 25-7/8”
(380 mm x 657 mm)
17 x 42-1/2”
(432 mm x 1080 mm)
Table 5
Insulated Wall
Drywall
Universal Offset Support
This support is used to support the chimney above an offset. When the chimney offset is used to traverse a wall this support may be used on the wall to support the chimney. The maximum heights are given in
Table 6.
For offset support installation, refer to the instructions provided
with the support.
CHIMNEY MAXIMUM HEIGHT OF
SUPPORTED CHIMNEY
7” Diameter Offset Support Roof Support
Secure Temp S2100+
Nova Temp HT6000+
Secure Temp GX
ACBI 40 feet (12.19 m). 50 feet (15.20 m).
16 feet (5.49 m). 18 feet (6.1 m).
Table 6
CHIMNEY CHASE AND MULTIPLE TERMINATIONS
For the purpose of this manual, a chimney chase is considered a part of the chimney system rather than part of a building. The termination must be placed a minimum of 18” (460 mm) above the chase.
For installations where more than one chimney is located in the same chase or within the same area, we suggest that their terminations be separated by at least 16” (410 mm) horizontally, and 18” (460 mm) verti­cally. This separation is to prevent smoke migrating from one chimney to another (see Figure 31).
Figure 30
Insulated Wall Radiation Shield
CHIMNEY SUPPORT INSTALLATION
Universal Roof Support
This support has three possible uses:
1. For Secure Temp S2100+ / Nova Temp HT6000+ / Secure Temp GX, it must be used on a roof to support the chimney.
2. It may be used on a floor, ceiling or roof above an offset to support the chimney above the offset.
3. It may be used on a floor, ceiling or roof as a supplementary support when the chimney height exceeds 15 feet (4.6 m).
Table 6 gives maximum height of supported chimney.
NOTE: For the ACBI chimney, a support section (ACBI7SL) must be used
every 30 feet (9m) or an universal support every 20 feet (6m) instead of the universal roof support (ST).
18
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 31
18” (460 mm)
16” (410 mm)
18” (460 mm)
16” (410 mm)
18” (460 mm)
INSTALLATION INSTRUCTIONS FOR MASONRY APPLICATION
Follow these steps:
WARNING: Before starting the installation, the masonry chimney must be inspected by a qualified chimney sweep.
The following requirements must be respected:
1. The chimney must be absolutely clear of any soot residue or creosote. Check for cracks, loose or missing bricks that could inhibit correct installation of the liner.
2. The clearance to combustible must be a minimum of 1” between the outside of the masonry and any wood framing or loose insulation.
3. The chimney must be built in accordance with the current building code.
4. No other appliance can be connected to the same chimney.
5. The clearances to combustible for the BISTMA30 connectors are 2” on the side and bottom and 16” at the top.
6. The connector parts are not necessary if the connection between the insulated length and the stainless steel liner is done within the masonry chimney.
Installation:
The chimney must be relined with a stainless steel liner model TUBINOX or Projet SS of the same diameter as the outlet of the fireplace.
For connection at 30º angle, a special connector (BISTMA30) must be used to connect the liner to the insulated chimney.
* IMPORTANT NOTE - The use of a 45º connector (BISTMA) is ap­proved for use in Canada ONLY. Installations in the USA must use the 30º connector (BISTMA30).
1- Position the fireplace in its location. Temporarily install the S2100+
elbow on the top of the fireplace and, using a level, mark with an oval
the location where the flue liner will enter the masonry chimney. 2- In the middle of the oval, drill a hole in the masonry chimney at 30º. 3- Increase the size of the hole until a 30º TUBINOX liner elbow can be
easily slipped through. 4- Slide the liner down from the top of the masonry chimney until you
reach the hole level. 5- Slip through the hole a 30º liner elbow and connect it to the liner. 6- Add a small liner section to the liner elbow which will allow the liner to
extend at least 12” (measured at the top of the liner) from the masonry
chimney. 7- Seal the opening around the liner with high temperature refractory
cement. 8- The next steps must be done in the following order:
See typical installation illustrated below.
A. Select the S2100+ length that will fit between the elbow and the liner
so that it will slide at least 2” over the liner section (You may need to
cut the liner for a better fit). B. Take that section and the BISTMA30 cover and slide it over the liner.
Make sure you have enough opening to be able to install the S2100+
elbow without difficulty. C. Install the 30º elbow on the fireplace. D. Slide the length section back down on the elbow and twist lock the
two together. E. Pull the cover down over the length and install the insulation pad over
the liner; be careful to cover the liner completely. F. Slide back the cover over the insulation and fix it in place using the 3
metal screws supplied.
Figure 32
6’ 8”
Insulation Pad & Cover (BISTMA or BISTMA3U)
* 30° S2100+ / GX Insulated Elbow
High-Temp. Cement
3 Screws
1” Clearance
Firestop
TUBINOX or Projet SS Stainless Steel
TUBINOX or Projet SS Liner Must Slide at Least 2” Inside Length
Insulated Length
Masonry Chimney, New or Existing
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
19
OPTIONAL INSTALLATION ACCESSORIES
CHIMNEY - PARTS AND COMPONENTS LISTS
Installation Accessories
Description Cat./Part No.
Facades (Required - Order Separately)
Montecito Estate™ Facade Black, MEFBK
Montecito Estate Facade Brushed Nickel, MEFBN
Montecito Estate Facade Hammered Steel, MEFMC
H4850
H4851
H4852
Doors - (Required - Order Separately)
Montecito Estate Doors Black, MECBK
Montecito Estate Doors Brushed Nickel, MECBN
Montecito Estate Doors Hammered Steel, MECMC
H4853
H4854
H4855
Outside Air Kit (included with fireplace)
Outside Air Coupler To Connect Outside Air (UZI) To Fireplace, UZIAD
Outside Air Ducting - includes 4” insulated flex x 10’ long, UZI UZI
UZIAD
Gravity Kit
Gravity kit: Complete double duct system includes: 2 elbows 90º,
2 telescopic lengths, 2 grill supports & 2 black grills, 2 fireplace adaptors.
7B30ZK-1
Gravity Kit Accessories
Black Grill With Support (set of 2) , 7B30ZO 7B30ZO
Brass Grill (for 7B30ZK-1) (set of 2), 7B30ZGB 7B30ZGB
Elbow 90º, 8” dia. I.D., 7B26ZE90 7B26ZE90
Elbow 45º, 8” dia. I.D., 7B26ZE45 7B26ZE45
Telescopic length, 8” dia. I.D. (15” to 26”), 7B26ZLA 7B26ZLA
Adjustable length, 8” dia. I.D. (2” - 5”), 7B26ZL2A 7B26ZL2A
Length five (5) feet, 8KL5 8KL5
Length four (4) feet, 8KL4 8KL4
Length three (3) feet, 8KL3 8KL3
Length two (2) feet, 8KL2 8KL2
Length one (1) feet, 8KL1 8KL1
Fireplace Kits
Rigid firescreen, BTZN BTZN
Masonry Chimney Adaptor, 30º, BISTMA30 (for use with TUBINOX liner)
BISTMA30
Secure Temp GX - 2” Insulated Galvanized Chimney System
(Recommended Insulated System)
Galvanized (7” ID & 11” OD) U.S.A. ONLY
Description Cat./Part No.
Lengths & Misc. Chimney Components
Length 8”, 7GXL8 7GXL8
Length 12”, 7GXL12 7GXL12
Length 18”, 7GXL18 7GXL18
Length 24”, 7GXL24 7GXL24
Length 24” (stainless steel exterior flue), 7XL24 7XL24
Length 36”, 7GXL36 7GXL36
Length 36” (stainless steel exterior flue), 7XL36 7XL36
Length 48”, 7GXL48 7GXL48
Length 48” (stainless steel exterior flue), 7XL48 7XL48
15º Elbow, 7GXE15 7GXE15
30º Elbow, 7GXE30 7GXE30
Rain Termination Cap, 7CC (stainless steel) 7CC
Wall Band, XBM XBM
Supports
Offset Support, XSO XSO
Roof / Floor support, XST XST
Roof Brace, XBS2 XBS2
Roof Flashings
Roof Flashing, Flat (includes spacer & collar), 7XF 7XF
Roof Flashing, Adjustable (5º to 30º) (includes spacer & collar), 7XFA
Roof Flashing, Adjustable (30º to 45º) (includes spacer & collar), 7XFB
Storm Collar (spacer included), 7XFC 7XFC
7XFA
7XFB
Firestops & Braces
Firestop, 7XBF 7XBF
Radiation shield, 7XRS 7XRS
Insulated attic radiation shield, 7XRSA 7XRSA
30º Insulated wall radiation shield, 7XRSMI30 7XRSMI30
Wall Band, XBM XBM
Fireplace Model MONTEST - Approved Venting Components manu­factured by Security Chimneys International only.
7” diameter chimney - ACBI (air cooled), Secure Temp™ GX (U.S.
only) and Secure Temp S-2100+ (or Nova Temp HT6000+).
7” diameter chimney for relining masonry chimneys - TUBINOX
chimney (or PROJET SS), 7” diameter with adaptor for installation in a masonry chimney.
20
Notes:
jNova Temp™ HT6000+ is equivalent to S-2100+
k Chimney Adaptor (S-2100+ / HT6000+) for CANADA ONLY - If you want to
install a S-2100+ / HT6000+ chimney, an adaptor is available (6UCA). lACBI Chimney is NOT recommended at elevations above 4,000 or in cold
climates (climates where temperatures will fall below 32° F / 0° C). With the
ACBI chimney, you must use a starter section before installing the first chimney
length (ACBI7SB or ACBI7SB30).
CHIMNEY - PARTS AND COMPONENTS LISTS
ACBI Chimney*
(7” I.D., 13” O.D. AC - Air Cooled)
* AC Chimney is NOT recommended at elevations above 4,000 feet or in cold climates
(climates where temperatures will fall below 32° F / 0° C).
Description Cat./Part No.
One of the following adaptors is required
if installing an AC chimney system
Starter Section w/ air intake, 7” Dia., ACBI7SB H3258
Offset Starter Section 30º, 7” Dia., ACBI7SB30 H3259
The following outside air kit is required if installing an AC chimney system
Outside Air Kit (Chimney) (4” ID Flex X 10’ Long, Insula­tion, Outside Register And Coupling), ACZI
H1967
Lengths & Misc. Chimney Components
12” Length, 7” Dia., ACBI7L12 H3252
18” Length, 7” Dia., ACBI7L18 H3253
36” Length, 7” Dia., ACBI7L36 H3254
48” Length, 7” Dia., ACBI7L48 H3255
15º Elbow, 7” Dia., ACBI7E15 H3256
30º Elbow, 7” Dia., ACBI7E30 H3257
Rain Termination Cap (regular), 7” Dia., ACBI7CPR H3260
Spark Arrester Screen (universal spark arrester band), PE PE
Wall Band, XBM XBM
Supports
Support section (10” long), ACBI7SL H3263
Universal support, AC10SU H3265
Roof Flashings
Flat roof flashing (includes spacer & collar), ACBI7FR H3275
Roof Flashing, Adjustable, 5º - 30º (includes spacer & collar), ACBI7FAR
Roof Flashing, Adjustable, 30º - 45º (includes spacer & collar), ACBI7FBR
H3276
H3277
Misc.
Firestop, ACBI7BF H3268
Radiation Shield, ACBI7RS H3269
Attic Radiation Shield, ACBI7RSA H3270
Telescopic Attic Radiation Shield, ACBI7RST H3271
Insulated Wall Radiation Shield 30º, AC10RSMI30 H3272
Storm Collar, AC10FC H3278
Rigid Stainless Steel Liner For Relining A Masonry Chimney, 7” Diameter
6” Length, 7” Dia., 7LL6 7LL6
12” Length, 7” Dia., 7LL12 7LL12
24” Length, 7” Dia., 7LL24 7LL24
36” Length, 7” Dia., 7LL36 7LL36
48” Length, 7” Dia., 7LL48 7LL48
Adjustable Length (7” to 11”), 7” Dia., 7L7A 7L7A
Split Base Tee, 7” Dia., 7LT 7LT
Tee Cap, 7” Dia., 7TCS 7TCS
Twist Lock Tee Cap, 7” Dia., 7LTC 7LTC
Elbow 30º, 7” Dia., 7LE30 7LE30
Elbow 45º, 7” Dia., 7LE45 7LE45
Elbow 90º, 7” Dia., 7LE90 7LE90
Rain Termination Cap (regular), 7” Dia., 7LCS 7LCS
Rain Termination Cap (deluxe), 7” Dia., 7LCC 7LCC
Listed to ULC-S635M, UL-1777 & ULC-S640M at 2100º F
Description Cat./Part No.
Supports
TUBINOX LL Chimney Lining System
Top Support, 7LST 7LST
Support Assembly, 7LSA 7LSA
Interior Support, 7LSB 7LSB
Adaptor Flexible Pipe (male), 7LAAM 7LAAM
Adaptor Flexible Pipe (female), 7LAAF 7LAAF
Stainless Steel Flex - five (5) feet Long, 7LLFLEX 7LLFLEX
Adj. Insulated Wall Radiation Shield 6” to 12”, 7LRSMI 7LRSMI
Adaptors to Masonry Chimney
Masonry Chimney Adaptor, 30º, BISTMA30 (for use with TUBINOX liner)
BISTMA30
21
REPLACEMENT PARTS LIST
SPECIFICATIONS
Montecito Estate™ - Replacement Parts
Description Cat./Part No.
Blower UZY5
Blower Motor Speed Control VRUW
Snap Disc, Blower VTU
Baffle refractory (2 pieces) (top of firebox) PR-ISO2205
Top Hearth Insulation PR-ISO2521
Front Refractory Bricks PR-SR2421
Back Refractory Brick PR-SR2415
Right Side Refractory Bricks - Back PR-SR2417
Right Side Refractory Bricks - Front PR-SR2419
Left Side Refractory Bricks - Back PR-SR2416
Left Side Refractory Bricks - Front PR-SR2418
Bottom Refractory Brick PR-SR2422
Wooden Door Handle PR-SR1787
Bottom Door Lock PR-SR2543
Top Door Lock PR-SR2405
Decorative Screw Caps, Black (2) PR-SACBTFBK2
Decorative Screw Caps, Brushed Nickel (2) PR-SACBTFBN2
Timer PR-SR2425
Ceramic Glass Left PR-SR2356G
Ceramic Glass Right PR-SR2356D
Secondary Air Tube (4) PR-SR2379
Log Retainers (2) B2CH
Around the Glass Gasket (61-3/4”) PR-SR1685C
On the Door Frame Gasket (48-3/8”) PR-SR1823I
Between the Doors Gasket (17-5/8”) PR-SR1823J
Touch-up Paint, Black 90L73
Outside Air Coupler For AC Chimney 4” ID, UACZI H3274
Outside Air Coupler To Connect Outside Air (UZI) To Fireplace, UZIAD
UZIAD
Cat. No. Model
H4842 MONTEST
Product Reference Information
Weight 450 lbs
Height 49-3/8”
Width 46-1/4”
Depth 27”
Firebox W x H x D measured in front
Chimney weight -
Secure Temp GX (7” dia)
Chimney weight - ACBI 3.75 lb/ft.
31” x 14-1/2” x 14”
9.5 lb/ft.
CLEARANCE TO COMBUSTIBLES
The following clearances meet the minimum requirements for a safe installation:
Side wall (fireplace front): 24” (457 mm) measured from the fireplace side.
Ceiling: 6’ 8” (2,032 mm) measured from the base of the fireplace
Fireplace enclosure: Bottom: 0” Side: 0” Back: 0”
Top: Do not fill the space above the fireplace with any material (Except the wood framing. See Figure 10)
Chimney: 2” (50 mm), except for through ceiling application, ACBI chimney, 1’’ (25 mm) clearance.
• Mantel: 56” (1422 mm) measured from the base of the fireplace.
22
NOTES
23
Lennox Hearth Products Wood Burning
Fireplaces, Stoves and Inserts 20 Year Limited Warranty
THE WARRANTY
Lennox Hea rth Products ("LHP") wa rrants the components of this wood b urning fact ory-built fireplace system, stov e or insert ma nufactured by LHP (LHP System) to be fr ee
from
defects in materia ls and wo rkmanship at the ti me of man ufacture.
REMEDY AND EXCLUSI ONS
The coverage of this Warra nty is limite d to all components of the fire place syste m, stove or insert manufact ured by LHP, with the exception of optional LH P tempered gl ass doors. A separate limited warranty is available from LHP for option al glass doors manufact ured by LHP. Ceramic glass doors manufact ured by LHP are warranted against thermal breakage only. LHP warran ts the components of this factory-built system manufactured by LHP (LHP System) to be free from defects in materials and workmanship at the time of manufacture.
(1) During the fir st five years of this Wa rranty, LHP will, at it s option and except for the components listed in subpara graphs (a) th rough (f), below, provide replac ement or repair
components of the LHP System manufactured by LHP, at n o charge, a nd will als o pay for re asonable l abor costs incurred in replacing or repairi ng such com ponents. I f repair or re placement is not commercially practicable , LHP will, at its option, refun d the purchase p rice o f the LHP Firepl ace, S tove o r Inse rt and LHP Chimney Com ponents and Accessories. With re spect to th e componen ts listed below, the remedies of t his paragr aph (1) are available only for the period of time indica ted. There after, however, until the expiration of 20 years from date of ins tallation, LHP will, subject to the conditions of par agraph (3) below, provide repla cements or repair s for those components at 50% off the then prevailing fa ctory lis t prices for those component s.
a. Cast iron, iron, or steel fuel grates a re consid ered consumable acc essories and therefore are n ot warran ted, with the excep tion of d efects in material or workma nship. b. Fireplace scre ens, inte rior refractories, and side shields (metal or r efractory ) - two years from date of i nstallation. c. Electrical component s, such as fan moto rs and bl owers - one year fr om date o f installation (lig ht bulbs are excluded). d. Certain model fireplaces are supplied with standard glass doors which are warranted 90 days f rom the date of i nstallati on for defects i n m aterial and w orkmanshi p.
Replacement glass for firep laces utilizing tem pered gla ss will be supplied at no-ch arge during the ter ms of the 90 day li mited war ranty wit h the following exc eptions:
Accidental glass b reakage o r damage to the gla ss door f rame finishes incur red in tr ansit, handling or operation either be fore, dur ing or af ter installation.
e. Certain fireplaces, stoves and inserts are suppl ied with ceramic gl ass, whic h is warranted agai nst therm al breakage only fo r 2 years from date of installation.
LHP will assume no responsi bility for glass re placement labor costs.
f. Certain f ireplaces, stoves a nd insert s are supplied with catalysts, which a re warran ted for a period of six year s. Warranty coverage for ye ars three - six will be pro-
rated from time of installa tion. g. Air tubes, baf fles and brick retainers - o ne year f rom date of install ation. h. By-pass damper assembly (catalytic models only) - f ive years from date of insta llation.
(2) During the six th through t enth year of the Warran ty, LHP will , at its option, provid e replacement or repai r components at no-charge, except a s is provide d for the components
listed in subparag raph (a) through (e) above. This cove rage provides for p arts only and does not inclu de any labor.
(3) During the eleventh throug h the twentieth year of the Warranty, LHP will, at its option, provide replacement or repair components at 50% off the then prevaili ng factory list prices
for those componen ts. This coverage only provi des for t he purchase of repl acement o r repair components at discount and do es not in clude any labor.
This Warranty covers only parts, and in some instances labor (as provided in subparagraph (1) above). In no case shall LHP be responsible for materia ls, parts or construction which were not ma nufactured or supplied by LHP or for the labor necessary to install, rep air, or remo ve such materials, part s or construc tion. All re placement or repair components wi ll be shipped F.O.B. the neare st LHP factory.
QUALIFICATIONS TO THE WARRA NTY
The complete firep lace Warr anty outlined above is furth er subject to the f ollowing qualifications:
(1) The factory-built fireplace system, stove or insert manufactu red by LHP (LHP System) must be instal led in accordance with LHP installation instructions and local building codes.
The Warrant y on this LHP syste m manufactured by LHP covers only the compone nt parts manuf actured by LHP . The use of compon ents manufactured by others with this LHP System could create seriou s safety hazards, may result in the denial of certification by recognize d national safety listing agencie s, and could be in violatio n of local building codes. This Warranty does not cover any damages occurr ing from the use of any components not manufactured or supplied by LHP. Any modifications to the system or the retro-fitting of any appliance t o the sys tem which alters th e functio n or performance of the appl iance will void thi s Warranty.
(2) The factory-b uilt fireplace system , stove or insert manuf actured by LHP (LHP Sys tem) is sub jected to normal use wi th fuels stated in the Ho me Owners Manual. Fact ory-built
fireplace system includes burning such natura l fireplace fuels as wood and
natural or propane gas. Fuel products with abnormal burning characteristics, including but not limited to fuel such as driftwoo d, coal or plywood and wood products using a binder, may burn at exc essive temp eratures an d may cause damage to the fac tory-buil t fireplace or may cause it to functi on improp erly; stoves and in serts are approved for burni ng dry se asoned wood only.
(3) Coverage of this Warranty is condition al upon use of an adequate fireplace grate on factory-built fireplaces only, when applicab le. Coverage of this warranty for stoves and inserts
is that these appl iances ar e operated without the use o f grates, irons or any other method to elevate the fire.
(4) LHP is not responsible for inadequate fir eplace, stov e or insert syste m draft caused by air condition ing, heating , mechanical systems, or gener al construction conditions which
may generate negat ive air p ressure in the room in which the appliance is i nstalled. Additionally LHP a ssumes no responsib ility for smoking condi tions cau sed by inadequate chimney heights fr om adjoin ing trees or buildi ng, adver se wind conditions or unusua l environmental fac tors and conditions .
LIMITATION ON LIAB ILITY
It is expressly agreed and und erstood that LHP’s sole obligation and pu rchaser’s exclusiv e remedy under this Wa rranty, under any other warranty, expresse d or im plied, otherwise, shall b e limited to replacement, re pair, or refund, as specifie d above.
In no event shall LHP be responsible for any incid ental or con sequentia l damages caused by defec ts in its prod ucts, whether such dama ge occurs or i s discovere d before or after replacement or repair, and whether or not such damage is caused by LHP’s negligence. Some states do not allow the exclusion or limitation of incidental or consequent ial damages, so the above limitatio n or exclusion may not a pply to you . The duration of any im plied warr anty with respect to th is LHP firepl ace is limi ted to the duration of t he foregoing warranty . Some st ates do not allow l imitation s on how long an im plied war ranty lasts, so the above ma y not appl y to you.
INVESTIGATION OF C LAIMS AGA INST WARRANTY
LHP reserves the r ight to i nvestigate any and all claim s against this Warr anty and to decide upon meth od of settlement.
LHP IS NOT RESPONS IBLE FOR WORK DONE WITHOUT W RITTEN CO NSENT
LHP shall in no ev ent be re sponsible for any w arranty w ork done without fi rst obtai ning LHP’s written consent.
DEALERS HAVE NO AU THORITY T O ALTER THIS WARRAN TY
LHP’s employees an d dealers have no authority to make a ny warranties nor t o authori ze any remedies in addition to or inco nsistent with thos e stated above.
HOW TO REGISTER A CLAIM AGA INST WARRANTY
In order for any claim under this Warranty to be valid, LHP must be notified of the claimed defec t in writing to Lennox Hearth Products, attent ion Customer Servic e Department, 1110 West Taft Avenue, Orange , CA. 92865, as soon as reasona bly possible after the defe ct is discovered. Claims ag ainst this Warranty in writing should incl ude the date of installatio n, and a description of the de fect.
OTHER RIGHTS
This Warranty give s you spe cific legal rights, and you may have other righ ts which vary from state to state.
The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.
Printed in Canada © 2006 by LENNOX HEARTH PRODUCTS
P/N 850,038M REV. B 02/2007
LHP
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.