Lennox MPLDV40, MPLDV30, MPLDV35, MPLDV45 User Manual

GAS APPLIANCE
KITS AND ACCESSORIES
WARNING: THIS CONVERSION KIT SHALL BE INSTALLED BY A QUALIFIED SERVICE AGENCY IN ACCORDANCE WITH THE MANUFACTURER'S IN­STRUCTIONS AND ALL APPLICABLE CODES AND REQUIREMENTS OF THE AUTHORIZED HAVING JURISDICTION. IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE, EXPLOSION OR PRODUCTION OF CARBON MONOXIDE MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. THE INSTALLATION IS NOT PROPER AND COM­PLETE UNTIL THE OPERATION OF THE CONVERTED APPLIANCE IS CHECKED AS SPECIFIED IN THE OWNER INSTRUCTIONS SUPPLIED WITH THE KIT. THE QUALIFIED SERVICE AGENCY PERFORMING THIS INSTALLATION ASSUMES RESPONSIBILITY FOR THIS CONVERSION.
750,217M REV. A 06/2007
GAS CONVERSION KIT
AVERTISSEMENT: CET ÉQUIPEMENT DE CONVERSION SERA INSTALLÉ PAR UNE AGENCE QUALIFIÉE DE SERVICE CONFORMÉMENT AUX INSTRUCTIONS DU FABRICANT ET TOUTES EXIGENCES ET CODES APPLICABLES DE L'AUTORISÉS AVOIR LA JURIDICTION. SI L'INFORMATION DANS CETTE INSTRUCTION N'EST PAS SUIVIE EXACTEMENT, UN FEU, EXPLOSION OU PRODUCTION DE PROTOXYDE DE CARBONE PEUT RÉSULTER LE DOMMAGES CAUSER DE PROPRIÉTÉ, PERTE OU BLESSURE PERSONNELLE DE VIE. L'AGENCE QUALIFIÉE DE SERVICE EST ESPONSABLE DE L'INSTALLATION PROPRE DE CET ÉQUIPMENT. L'INSTALLATION N'EST PAS PROPRE ET COMPLÉTE JUSQU'À L'OPÉRATION DE L'APPAREIL CONVERTI EST CHÉQUE SUIVANT LES CRITÈRES ÉTABLIS DANS LES INSTRUCTIONS DE PROPRIÉTAIRE PROVISIONNÉES AVEC L'ÉQUIPEMENT.
In Canada: THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN1-B149.1 AND .2 INSTALLATION CODE.
LA CONVERSION DEVRA ÊTRE EFFECTUÉE CONFORMÉMENT AUX RECOMMANDATIONS DES AUTORITÉS PROVINCIALES AYANT JURIDICTION ET CONFORMÉMENT AUX EXIGENCES DU CODE D'INSTALLATION CAN1­B149.1 ET.2.
Gas conversion kits are available to adapt your appliance from the use of one type of gas to the use of another. These kits contain all the nec­essary components needed to complete the task including labeling that must be affixed to ensure safe operation.
Kit part numbers are listed here and the follow­ing steps detail the conversion procedure.
CAUTION: THE GAS SUPPLY SHALL BE SHUT OFF PRIOR TO DISCONNECTING THE ELEC­TRICAL POWER, BEFORE PROCEEDING WITH THE CONVERSION.
tiK
.oNsledoMepyTtinU.oNgolataC 53VDLEcinortcele7593H 04VDLEcinortcele8593H 54VDLEcinortcele9593H
03VDLPMcinortcele6616H 53VDLPMcinortcele7616H 04VDLPMcinortcele8616H 54VDLPMcinortcele9616H
tiK
.oNledoMepyTtinU.oNgolataC 53VDLEcinortcele5074H 04VDLEcinortcele6074H 54VDLEcinortcele7074H
03VDLPMcinortcele0716H 53VDLPMcinortcele1716H 04VDLPMcinortcele2716H 54VDLPMcinortcele3716H
noisrevnoCsaGenaporPoTlarutaN
noisrevnoCsaGlarutaNotenaporP
Step 1. Turn off the gas supply to the appliance
and disconnect the electrical power. Remove the front glass door from the appliance.
Step 2. Carefully remove the logs. Exercise care so as not to break the logs.
Step 3. Refer to
Remove the burner assembly with attached venturi tube.
Gas Valve Assembly
Figure 1
.
Burner Assembly
Orifice
Figure 1 (ELDV Model Shown)
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
1
Ground
(TP)
Gas Outlet
To Burner
Pilot Stage Terminal
TP
Use pipe joint compound or Teflon tape on all
Pressure-Tap (Inlet)
Pilot Gas Outlet
pipe fittings before installing (ensure propane resistant compounds are used in propane ap­plications, do not use pipe joint compounds on flare fittings).
HI
VENT
IN
OUT
PILOT
Air
Supply Gas
IN
Inlet
Venturi
Shutter
Rod
TH
TP
LO
TH
Burner Stage Terminal
Regulator Mounting Screw
Figure 2
ELECTRONIC
Sensor
Pilot Hood
Ignitor
Note: If the ignitor is damaged, a replacement kit is available, order Catalog Number 87L54.
Figure 3
Electronic Appliances Step 4. Dexen Electronic Valves - See
and the instructions provided with the kit. Re­move and discard the two pressure regulator mounting screws. Remove the pressure regu­lator and diaphragm. Discard all removed components. Ensure the provided diaphragm is installed properly onto the replacement pres­sure regulator and install the new pressure regulator using the new screws supplied with the kit. Tighten screws.
See
Figure 3
and replace the pilot orifice as follows: Remove pilot hood assembly to access the phillipped pilot orifice. Remove and replace the orifice with the one provided with the kit.
Figure 2
Pressure-Tap (Manifold)
Exercise extreme care to prevent damage to or breakage of the ignitor assembly.
Step 5. (Refer to
Figure 1
) A. Remove the orifice from the manifold and replace it with the one provided in the kit. See the following table for orifice sizes for natural and propane models
. Figure 4
illustrates the orifice.
B. Retrieve the burner and slide the venturi tube over the orifice. Set the shutter adjusting opening as shown in
Figure 5
.
ezisecifirO
.oNledoM
larutaNenaporP
53VDLE83#35# 04VDLE73#"260.0 54VDLE63#"560.0
03VDLPM"070.016# 53VDLPM65#74# 04VDLPM14#45# 54VDLPM04#35#
Figure 4
Step 6. Reassemble the remaining compo-
nents by reversing the procedures outlined in the preceding steps.
Valve
Lever Arm
RENRUBNIAM
GNITTESGNINEPORETTUHSYROTCAF
sledoM
saGlarutaN
)mm(sehcni
saGenaporP
)mm(sehcni
53VDLE8/1)2.3(8/3)5.9( 04VDLE)6.1(61/1)5.9(8/3 54VDLE)2.3(8/1)5.9(8/3
03VDLPM)4.2(23/3)7.4(61/3 53VDLPM)4.2(23/3)6.1(8/1 04VDLPM)7.4(61/3)5.9(8/3 54VDLPM)7.4(61/3)7.21(2/1
Figure 5
Step 7. Attach appropriate conversion kit label
(
Figure 6
) to the rating plate on the appliance.
THIS APPLIANCE HAS BEEN CONVERTED TO:
NATURAL GAS
INPUT BTU/HR – 50,000 MANIFOLD PRESSURE – 3.5" ORIFICE SIZE – (0.130)
THIS APPLIANCE HAS BEEN CONVERTED TO:
PROPANE/LPG
INPUT BTU/HR – 50,000 MANIFOLD PRESSURE – 10" ORIFICE SIZE – (0.080)
Figure 6
Step 8. Turn on gas supply and test for gas
leaks, using a soapy water solution.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.
Printed in U.S.A. © 2006 by Lennox
P/N 750,217M REV. A 06/2007