Lennox MPE-33R User Manual

INSTALLATION AND OPERATING INSTRUCTIONS
®
MERIT PLUS SERIES
LENNOX HEARTH PRODUCTS
33" Electric Fireplace P/N 850,032M REV. C 10/2006
MODEL:
This manual will enable you to obtain a safe, effi cient and dependable installation and operation of your electric fi replace. Please read and understand these instructions before beginning your installation.
Do not alter or modify this fi replace or its components under any circum­stances. Any modifi cation or alteration of the fi replace system, including but not limited to the fi replace and accessories, may void the warranty, listings and approvals of this system and could result in an unsafe and potentially dangerous installation.
IMPORTANT! IF OPTIONAL GLASS DOORS ARE PURCHASED, TO ASSURE PROPER ALIGNMENT, INSTALL THIS FIREPLACE IN A SQUARE AND PLUMB CONDITION, USING SHIMS AS NECESSARY AT SIDES. THIS APPLIANCE IS MOUNTED ON RUBBER FEET TO ENSURE ADEQUATE AIR CIRCULATION BENEATH FIREPLACE. DO NOT BLOCK AIRFLOW AT THE BOTTOM AIR INTAKES.
MPE-33R
SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
INSTALLER: DO NOT DISCARD THIS MANUAL
PLEASE LEAVE FOR THE HOMEOWNER
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
A French manual is available upon request. Order P/N 850,032CF Ce manuel d’installation est disponible en francais, simplement en
faire la demande. Numéro de la pièce 850,032CF.
C
®
US
Report # C1482763
IMPORTANT SAFETY AND WARNIING INFORMATION
READ THIS MANUAL IN ITS ENTIRETY AND UNDERSTAND THESE RULES TO FOLLOW FOR SAFETY.
WARNING
If the information in this manual is not followed exactly, an elec­trical shock or fi re may result causing property damage, per­sonal injury or loss of life.
IMPORTANT
Before starting your fi replace installation, read this instal­lation and operation manual very carefully to ensure you understand it completely and in entirety. Failure to follow these instructions may result in a pos­sible electric shock, fi re hazard and/or injury or property damage and will void the warranty.
CAUTION
This appliance is mounted on rubber feet. The purpose of these feet is to ensure adequate air circulation beneath the fi replace. Do not remove these feet. Do not install the fi replace directly onto a carpet, rug, furniture or similar surfaces, which could hinder or block the airfl ow.
CAUTION
Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left oper­ating and unattended.
IMPORTANT
Cold climate installation recom­mendation: when installing this fi replace against a non-insulated exterior wall or chase, it is mandatory that the outer walls be insulated to conform to appli­cable insulation codes.
WARNING
To prevent contact with sag­ging or loose insulation, the appliance must not be installed against vapor barriers or exposed insulation. Localized overheat­ing could occur and a fi re could result. Insulation and a vapor barrier should be placed a minimum of 2 inches from the appliance.
TO PREVENT A POSSIBLE FIRE, DO NOT BLOCK AIR INTAKES OR EXHAUSTS IN ANY WAY. DO NOT USE NEAR SOFT SURFACES, LIKE A PILLOW, WHERE OPENINGS MAY BECOME BLOCKED.
THIS APPLIANCE MAY BECOME HOT WHEN IN USE. TO AVOID BURNS, DO NOT LET BARE SKIN TOUCH HOT SUR­FACES. KEEP COMBUSTIBLE MATERI­ALS, SUCH AS FURNITURE, PILLOWS, BEDDING, PAPERS, CLOTHES AND CURTAINS AT LEAST 3 FEET (1 METER) FROM THE FRONT OF THIS APPLI­ANCE.
DO NOT OPERATE ANY HEATER WITH DAMAGED WIRING OR CONNECTORS, OR AFTER THE APPLIANCE MALFUNC­TIONS, OR IF IT HAS BEEN DROPPED OR DAMAGED IN ANY WAY.
ANY REPAIRS TO THIS FIREPLACE SHOULD BE PERFORMED BY A QUALI­FIED SERVICE TECHNICIAN.
UNDER NO CIRCUMSTANCES SHOULD THIS FIREPLACE BE MODIFIED. PARTS HAVING TO BE REMOVED FOR SERVIC­ING MUST BE REPLACED PRIOR TO OPERATING THE FIREPLACE AGAIN.
DO NOT USE THIS APPLIANCE OUT­DOORS. DO NOT EXPOSE FIREPLACE TO THE ELEMENTS (SUCH AS RAIN, ETC.).
THIS APPLIANCE IS NOT INTENDED FOR USE IN BATHROOMS, LAUNDRY AREAS OR SIMILAR INDOOR LOCA­TIONS. NEVER LOCATE THIS APPLI­ANCE WHERE IT COULD FALL INTO A BATHTUB OR OTHER WATER CON­TAINER.
DO NOT RUN ELECTRICAL WIRING OR POWER CORD UNDER CARPETING. OR COVER WITH THROW RUGS, RUNNERS OR SIMILAR MATERIALS.
FOR 120 VAC POWER CORD AVOID THE USE OF AN EXTENSION CORD BECAUSE THE EXTENSION CORD MAY OVERHEAT AND CAUSE A RISK OF FIRE. HOW­EVER, IF YOU HAVE TO USE AN EXTEN­SION CORD, THE CORD SHALL BE NO. 14 AWG MINIMUM SIZE AND RATED NOT LESS THAN 1800 WATTS, 15 AMPS. THE EXTENSION CORD MUST BE A THREE CONDUCTOR SHEATH CABLE WITH GROUNDING TYPE PLUG AND CORD CONNECTION.
THIS APPLIANCE HAS HOT AND ARCING OR SPARKING PARTS INSIDE. DO NOT USE IT IN AREAS WHERE GASOLINE, PAINT OR FLAMMABLE LIQUIDS ARE USED OR STORED.
THIS FIREPLACE SHOULD NOT BE USED AS A DRYING RACK FOR CLOTHING, NOR SHOULD CHRISTMAS STOCKINGS OR OTHER DECORATIONS BE HUNG NEAR IT.
USE THIS APPLIANCE ONLY AS DESCRIBED IN THIS MANUAL. ANY OTHER USE IS NOT RECOMMENDED BY THE MANUFACTURER AND MAY CAUSE A FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS.
IF APPLIANCE IS TO BE DISCON­NECTED, TURN OFF CONTROLS FIRST.
DO NOT INSERT OR ALLOW FOREIGN OBJECTS TO ENTER ANY VENTILATION OR EXHAUST OPENING, AS THIS MAY CAUSE AN ELECTRIC SHOCK, FIRE, OR DAMAGE TO THE APPLIANCE.
SAVE THESE INSTRUCTIONS.
2
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
CONGRATULATIONS!
In selecting this LENNOX Merit Plus electric fi replace, you have chosen the fi nest and most dependable fi replace found anywhere. A beautiful and prestigious addition to the fi nest homes. Welcome to a Family of hundreds of thousands of satisfi ed LENNOX Fireplace Owners.
Please read and carefully follow all of the instructions found in this manual. Please pay special attention to the safety instructions provided in this manual. The instruc­tions included here will assure that you have many years of dependable and enjoyable service from your LENNOX product.
Power Supply Wire Gage
Voltage Wire Gage Fuse
120 V 14 GA. 15 AMP
240 V 14 GA. 20 AMP
Wall Switch / Thermostat Wire Gage
Voltage Wire Gage
5 VOLTS 18 GAGE
Table 1
TABLE OF CONTENTS
Important Safety Information ........... Page 2
Packaging List .................................. Page 3
Introduction ..................................... Page 3
General Information ......................... Page 3
Locating Fireplace ............................ Page 3
Tools/Supplies Required .................. Page 3
Framing Specifi cations ..................... Page 4
Fireplace Specifi cations .................... Page 4
Clearances ....................................... Page 5
Pre-installation ................................. Page 5
Installation Steps ............................. Page 5
Electrical Connections ...................... Page 5
Final Finishing .................................. Page 6
Break-In Period ................................ Page 6
Control Panel Operation ................... Page 6
Remote Control Operation ............... Page 7
Maintenance ..................................... Page 8
Wiring Diagrams .............................. Page 10
Troubleshooting ............................... Page 15
Replacement Parts ........................... Page 16
Optional Accessories ........................ Page 18
PACKAGING LIST
This assembled Electric Room Heater is packaged with:
• One accessory package located in the fi rebox, containing;
1. One Installation and Operation Manual.
2. One Warranty Certifi cate.
3. One Remote Control.
• Two spare Light Bulbs are located in a recess on the back of the log assembly.
INTRODUCTION
This Electric Fireplace is designed for residential applications to be framed in as a fi replace.
This appliance has been tested in accor­dance with UL 2021 and CSA C22.2 No. 46-M198 standards for fi xed and location dedicated electric room heaters.
Installation must conform to local codes. In the absence of local codes, electrical wiring and grounding must comply with the National Electrical Code ANSI/ NFPA 70 - latest edition. In Canada, the cur­rent CSA C22-1 Canadian Electrical Code
- latest edition.
GENERAL INFORMATION
Power Supply Wire Specifi cations
120 Volt, 60 Hz, 1600 Watts: (ref. Page 10)
Hard Wire Connection - Use two conductor, non-metallic sheath cable with ground wire (total three wires) for the incoming power supply. The wire used must conform to local and national electrical codes for the specifi ed power consumption rating. See Table 1.
240 Volt, 60 Hz, 3000 Watt: (ref. Page 11)
Use three conductor, non-metallic sheath cable with ground wire (total four wires) for the incoming power supply. The wire used must conform to local and national electrical codes for the specifi ed power consumption rating. See Table 1.
Wall Switch or Wall Thermostat Kits (optional kits, see Page 17)
Low voltage wire is provided for the wall switch connection. The wires gage requirements are shown on Table 1.
WARNING
Do not install or operate this fi re­place through a switch wired in the 120 VAC or 240 VAC circuits. The only approved wiring for a switch is through the low voltage circuit (24 VAC) as shown on Page 14.
LOCATING YOUR MERIT PLUS ELECTRIC FIREPLACE
Your new fi replace may be installed into existing framing or built into a wall (see Figure 1).
When choosing a location for your new fi re­place, ensure that the general instructions are followed. Also, for the best effect, install the fi replace out of direct sunlight and away from overhead lighting. See Figure 1.
Top View Showing Approved
Room Locations of Fireplace
fi replace shown in gray.
Figure 1
TOOLS AND BUILDING SUPPLIES NORMALLY REQUIRED
TOOLS:
Phillips Screwdriver 7/16" Socket Drive Hammer Saw And/or Saber Saw Level Measuring Tape Plumb Line Electric Drill And Bits Pliers Square
Gloves
BUILDING SUPPLIES:
Framing Materials Wall Finishing Materials Caulking Materials (noncombustible)
IMPORTANT NOTE: This fi replace system is not diffi cult to install. However, in the interest of safety, it is recommended that the installer be a qualifi ed or certifi ed “tradesman” familiar with commonly accepted fi replace installation and safety techniques as well as prevailing local codes.
3
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
3
FRAMING SPECIFICATIONS
25-5/8 "
(651 mm)
36-1/4 "
(921 mm)
Electrical Junction Box
Corner View
Note: Framing dimensions are calculated for a nailing fl ange depth of 1/2"
Figure 2
35-1/4 "
(895 mm)
51-1/4 "
(1302 mm)
35-1/4 "
(895 mm)
Front View
32 "
(812 mm)
4 "
(102 mm)
Electrical Junction Box
(left side)
15-1/8 "
(384 mm)
Side View
FIREPLACE SPECIFICATIONS
Electrical Access Cover
Power Cord
32 "
Left Side
(812 mm)
13-3/4"
(350 mm)
5-1/8 "
(130 mm)
21-1/8 "
(537 mm)
Top View
34-1/2"
(876 mm)
Front View
14-7/8"
(32 mm)
21-1/8 "
(537 mm)
27-1/2 "
(
700 mm
24-1/2"
(622 mm)
)
Right Side
29-3/4 "
(754 mm)
4
Figure 3
Electrical Access
33 "
(838 mm)
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
5-1/4 "
(134 mm)
2-1/4 "
(55 mm)
FIREPLACE SPECIFICATIONS
Cat. No. H3427 Model: MPE-33R Description: Merit Plus Electric Fireplace, 33” Radiant Shipping Weight: 81 lb.'s (36.75 KG) Packaging:
41” x 17 3/4” x 33 1/2” (1040 mm x 451 mm x 850 mm)
14.1 cu. ft. Power Requirements: (120 Volt, 60 Hz.) Rated Wattage - 1600 Watts Amperage - 13.33 Amps (240 Volt, 60 Hz.) Rated Wattage - 3000 Watts Amperage - 12.5 Amps Blower CFM: 83 CFM (120 V): 5,461 BTU/HR (240 V): 10,239 BTU/HR
MINIMUM CLEARANCES TO COMBUS­TIBLES
This appliance is an electric fi replace designed to be framed in with combustible materials (up to the edge of the appliance). A drywall lip at the top of the fi replace and 4 nailing fl anges on the sides of the appliance is provided to facilitate installation.
Clearances
Sides 0 inches - 0 mm
Floor 0 inches - 0 mm
Top 0 inches - 0 mm
Table 2
Mantel Clearance: Combustible and Non-com­bustible mantels may be installed at any height above the top of the face of fi replace.
Hearth Protection: A hearth is not mandatory, but it is recommended for aesthetic purposes. Secure the hearth extension to the fl oor to prevent possible shifting. Do no block the air­fl ow beneath the appliance (read the following WARNING).
PRE-INSTALLATION
Before You Start
Check appliance for any concealed damage.
DETAILED INSTALLATION STEPS
1. Complete the framing opening to the dimen-
sions specifi ed in Figure 2.
2. Prepare the connections to power source: 120 Volt Connections - Locate the power
cord on the left side of the unit and connect it to the outlet installed during the framing (see Figure 2). Verify that the power to the
receptacle is off. Hard wired installation: Ensure that there is a minimum of 8" of the
service cable for connection to the junction
box on the fi replace.
- Loosen four screws to remove the junction box cover plate.
- Disconnect and remove the 120 Volt power cord from the fi replace wires.
- Position the fi replace into the framed-in opening. Attach fi replace to frame using nailing fl anges provided.
- Complete the wiring to the fi replace as shown on Page 10.
- Place all wire connectors inside the junction box.
- Attach junction box cover plate with four screws.
240 Volt Connections - Ensure that there
is a minimum of 8" of the service cable for connection to the junction box on the fi replace.
- Loosen four screws to remove the junction box cover plate.
- Disconnect and remove the 120 Volt power cord from the fi replace wires.
- Position the fi replace into the framed-in opening. Attach fi replace to frame using nailing fl anges provided.
- Complete the wiring to the fi replace as shown on Page 11.
- Place all wire connectors inside the junction box.
- Attach junction box cover plate with four screws.
The fi replace wires L1, L2, N, N1, N2 and
G are attached to the rear of the junction box cable clamp for easy access.
3. Wire a dedicated, properly fused circuit with an Amp rating for the appropriate voltage (120 V - 15 Amps or 240 V - 20 Amps). A dedicated circuit is required to prevent overloading a house circuit in cases of having multiple appliances on the same circuit. Use an outlet that is protected by a ground fault circuit interrupter where required by electrical code.
4. (If applicable) Make wall mount wall switch or wall thermostat connections as outlined on Pages 11 & 12.
5. Perform a function test. See Manual Control
Panel Operation on Page 6 and Remote Control Operation on Page 7.
ELECTRICAL CONNECTIONS
Refer to the electrical diagrams on Pages 10 to 14.
WARNING
Electrical wiring must comply with local building codes and other applicable regulations to reduce the risk of fi re, electrical shock and injury to individuals.
IMPORTANT
Any electrical re-wiring of this appliance must be done by a qualifi ed electrician.
WARNING
Do not use this fi replace if any part of it has been underwater. Immediately call a qualified service technician to inspect the fi replace and replace any part of the electrical system which has been under water.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
5
FINAL FINISHING
Materials such as brick and tile can be extended down to the top of the fi replace. Do not extend down, covering the outlet or glass enclosure panel (optional kit).
There are a wide variety of “fi nished looks” for these fi replaces, from formal wall decor with elaborate mantels to rustic wood paneling or warm brick facings.
Accent Trim Installations
Note: Ensure the circuit breakers for the power supply are turned on.
This appliance can be operated either from the manual control panel (see Figures 4 & 5) or by using the remote control, wall switch or wall thermostat (optional kits).
The manual controls are located on the fi rebox fl oor on the front left (see Figure 5). If an optional glass enclosure is installed, it must be removed to access.
Main Power ON/OFF Switch
When the main power switch is turned on, power is supplied to the fi replace. This switch must be on for all other switches to operate.
Heater ON/OFF Switch
When this switch is turned on, the heater will emit heat in the temperature range selected (see Figure 6; G, H & I). The fi replace can operate with or without heat.
Flame / Ember On/Off Switch:
Turns lights on inside ember bed and fl ame cylinder.
An optional accent trim kit is available from your dealer (see Page 18). These options give the appliance an attractive fi nished look.
Hearth
An aesthetically pleasing fi replace hearth can be installed, if desired (see hearth protection on Page 5).
BREAK-IN PERIOD:
During the fi rst few initial uses of this heater, there may be a release of a slight, harmless odor. This odor is a normal occurrence caused by the initial heating of the internal heating elements and should not reoccur.
MANUAL CONTROL PANEL OPERATION
(refer to Figures 5 & 6)
Once this appliance has been properly installed and connected to the power supply as defi ned in this manual, it is ready to operate.
MANUAL CONTROL PANEL
Main Power On/Off (rear most switch)
On
Off
Heater On/Off (center switch)
On
Off
Flame / Ember On/Off (front most switch)
On
Figure 4
Off
• When using the main power on/off switch inside the manual control panel, the power on/off switch outside the manual control panel (optional wall switch kit) must be in the OFF position.
• When using power on/off switch outside the manual control panel (optional wall switch), the power on/off switch inside the manual control panel must be in the OFF position.
• When using the remote control, the power on/off switch inside the manual control panel and the wall switch (optional kit) must be on the OFF position.
Manual Control Switches
are located behind pull
screen on inside fl oor
Figure 5
6
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Loading...
+ 14 hidden pages