Lennox Homeowner's Care And Operation Instructions Manual
Specifications and Main Features
Frequently Asked Questions
User Manual
HOMEOWNER'S CARE AND
OPERATION INSTRUCTIONS
DIRECT VENT SEE-THROUGH
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNINGS
• Hot! Do not touch! The glass and
surfaces of this appliance will be hot
during operation and will retain heat
for a while after shutting off the appliance. Severe burns may result.
Carefully supervise children in the
•
same room as appliance.
If small children are present in the home, it is
•
recommended that this appliance be fi tted with
a screen door or screen panel kit. See Page 14
for ordering information.
WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY: Do not store or use gasoline
or other fl ammables or liquids in the vicinity of
this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
MERIT® PLUS SERIES
DIRECT-VENT GAS FIREPLACE HEATERS
P/N 875,025M REV. A 05/2006
MODELS
Millivolt Models Electronic Models
MPD35ST-NM MPD35ST-NE
MPD35ST-PM
A French manual is available upon request. Order P/N 875,025CF
Ce manuel d’installation est disponible en francais, simplement en
faire la demande. Numéro de la pièce 875,025CF
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN
SUIVRE LES INSTRUCTIONS DONNÉ DANS CETTE
NOTICE POUR RÉDUIRE AU MINIMUM LE RISQUE
D'INCENDIE OU POUR ÉVITER TOUT DOMMAGE
MATÉRIEL, TOUTE BLESSURE OU LA MORT.
POUR VOTRE SÉCURITÉ: Ne pas entreposer ni
utiliser d'essence ni d'autre vapeurs ou liquides
infl ammables dans le voisinage de cet appareil ou
de tout autre appareil.
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow your gas suppliers
instructions.
• If your gas supplier cannot be reached, call
the fi re department.
Installation and service must be performed by
a qualifi ed installer, service agency or the gas
supplier.
OTL Report No. 116-F-28-5
POUR VOTRE SÉCURITÉ: Que faire si vous sentez
une odeur de gaz:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous
servir des téléphones se trouvant dans le batiment où vous vous trouvez.
• Evacuez la piéce, le bâtiment ou la zone.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions
du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de
gaz, appelez le service dos incendies.
L'installation et service doit être exécuté par un
qualifi é installeur, agence de service ou le fournisseur de gaz.
SAFETY & WARNIING
INFORMATION
IMPORTANT: PLEASE READ THIS
MANUAL IN ITS ENTIRETY AND
UNDERSTAND THESE RULES TO
FOLLOW FOR SAFETY.
WARNING
If the information in this
manual is not followed
exactly, a fi re or explosion may result causing property damage,
personal injury or loss
of life.
WARNING
Improper installation, adjustment, alteration, service or
maintenance can cause injury
or property damage. Refer to
this manual. For assistance or
additional information consult
a qualified installer, service
agency or the gas supplier.
WARNING
Children and adults should be
alerted to the hazards of high
surface temperatures. Use
caution around the appliance
to avoid burns or clothing ignition. Young children should be
carefully supervised when they
are in the same room as the
appliance.
Note: An Optional Screen Panel
for the glass is available (see
Page 14 for ordering information).
WARNING
Do not place clothing or other
fl ammable materials on or near
this appliance.
AVERTISSEMENT
Surveiller les enfants. Garder les
vêtements, les meubles, l'essence
ou autres liquides à vapeur infl ammables à cote de l'appareil.
WARNING
Do not use these appliances if
any part has been under water.
Immediately call a qualifi ed,
professional service technician
to inspect the appliances and to
replace any parts of the control
system and any gas controls
which have been under water.
AVERTISSEMENT
Ne pas se servir de cet appareil
s'il a été plongé dans l'eau,
complètement ou en partie.
Appeler un technicien qualifi é
pour inspecter l'appareil et remplacer toute partie du système de
contrôle et toute commande qui
ont été plongés dans l'eau.
WARNING
Do not attempt to alter or modify
the construction of the appliance
or its components. Any modifi cation or alteration may void
the warranty, certifi cation and
listings of this unit.
WARNING
Failure to comply with the installation and operating instructions
provided in this document will
result in an improperly installed
and operating appliance, voiding
its warranty. Any change to this
appliance and/or its operating
controls is dangerous. Improper
installation or use of this appliance can cause serious injury or
death from fi re, burns, explosion
or carbon monoxide poisoning.
IMPORTANT
These appliances must not be
connected to a chimney or fl ue
serving a separate Solid-Fuel
burning appliance.
2
WARNING
Carbon monoxide poisoning:
early signs of carbon monoxide
poisoning are similar to the fl u
with headaches, dizziness and/or
nausea. If you have these signs,
obtain fresh air immediately.
Turn off the gas supply to the
appliance and have it serviced
by a qualifi ed professional, as it
may not be operating correctly.
WARNING
Any safety guard or screen
removed for servicing the appliance must be replaced prior to
operating the appliance.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
WARNING
This appliance is only for use with
the type of gas indicated on rating
plate. This appliance is not convertible for use with other gases,
unless a certifi ed kit is used.
AVERTISSEMENT
Cet appareil doit être utilisé
uniquement avec les types de
gaz indiqués sur la plaque signalétique. Ne pas l'utiliser avec
d'autres gaz sauf si un kit de
conversion certifi é est installé.
WARNING
These fi replaces are vented heaters. Do not burn wood or other
material in these appliances.
CONGRATULATIONS!
In selecting this LENNOX Direct-Vent Gas Appliance you have chosen the fi nest and most
dependable fi replace to be found anywhere. Its a beautiful, prestigious alternative
to a wood burning fi replace. Welcome to a Family of tens of thousands of satisfi ed
LENNOX Fireplace Owners.
Please carefully read and follow all of the instructions found in this manual. Please pay
special attention to the safety instructions provided in this manual. The Homeowner's
Care and Operation Instructions included here will assure that you have many years
of dependable and enjoyable service from your LENNOX product.
Replacement Parts List .....................Page 24
INTRODUCTION
The Fireplace models covered in this manual
are Direct-Vent sealed combustion gas fi replace
heaters designed for residential application.
Direct-Vent appliances operate with the combustion chamber completely isolated from the
indoor environment. All air for combustion is
brought in from the outside and exhaust gases
are vented through the same direct vent, co-axial
(intake/exhaust) vent system.
The Millivolt appliances have a millivolt gas
control valve with piezo ignition system provides
safe, effi cient operation. If any optional accessories which require electrical power are being
installed, the electrical power must be provided
at the time of appliance installation.
The Electronic appliances have an electronic
intermittent pilot system provides safe, effi cient
operation. External electrical power is required
to operate these appliances.
These appliances comply with National Safety
Standards and are tested and listed by OMNITest Laboratories, Inc. (Report No.116-F-28-5)
to ANSI Z21.88a-2003 (in Canada, CSA-2.33a-
2003), and CAN/CGA-2.17-M91 in both USA and
Canada, as vented gas fi replace heaters.
The Installation must conform to local codes
or, in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1/NFPA
54-latest edition, or the Natural Gas and
Propane Installation Code, CSA B149.1-latest
edition. The appliance, when installed, must
be electrically grounded in accordance with
local codes or, in the absence of local codes,
the latest edition of the National Electrical Code,
ANSI/NFPA 70, or the Canadian Electrical Code,
CSA C22.1 - latest editions.
GENERAL INFORMATION
Note: Installation and repair should be performed by a qualifi ed service person. The
appliance should be inspected annually by a
qualifi ed professional service technician. More
frequent inspections and cleanings may be
required due to excessive lint from carpeting,
bedding material, etc.
It is imperative that the control compartment,
burners and circulating air passage ways of
appliance be kept clean. See Maintenance
instructions on Page 5.
S'assurer que le brùleur et le compartiment des
commandes sont propres. Voir les instructions
d'installation et d'utilisation qui accompagnent
l'appareil.
Provide adequate clearances around air openings and adequate accessibility clearance for
service and proper operation. Never obstruct
the front openings of the appliance.
Due to high temperatures the appliance should
be located out of traffi c and away from furniture
and draperies. Locate furniture and window
coverings accordingly.
These fi replaces are designed as supplemental heaters. Therefore, it is advisable to have
an alternate heat source when installed in a
dwelling.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
These appliances are designed to operate on natu ral
gas or propane gas only. The use of other fuels or
combination of fuels will degrade the performance
of this system and may be dangerous.
Millivolt Models - BTU Input
Millivolt models come standard with the manually-modulated gas valve; fl ame appearance and
heat output can be controlled at the gas valve.
The BTU Input for millivolt models is shown
in Table 1:
Input (BTU) Manually-Modulated Gas
Valves (millivolt models)
ModelsFuel
Type
MPD35ST-NMNat. Gas
MPD35ST-PMPropane
Input Rate
(BTU / HR)
30,000 high
23,000 low
28,000 high
22,000 low
Table 1
Electronic Models -
Electronic models have a fi xed rate gas valve.
The BTU Input for electronic models is shown
in Table 2:
Input (BTU) - Fixed Rate
(electronic models)
ModelsFuel
Type
MPD35ST-NENat. Gas30,000
MPD35ST-PE
(if fi eld converted)
Pro. Gas28,000
Input Rate
(BTU / HR)
Table 2
Gas Pressure -
Tables 3, 4 and 5 show the appliances' gas
pressure requirements.
Inlet Gas Supply Pressure
(all models)
Fuel #MinimumMaximum
Natural Gas
Propane
5.0" WC
(1.24 kPa)
11.0" WC
(2.74 kPa)
10.5" WC
(2.61 kPa)
13.0" WC
(3.23 kPa)
Table 3
Manifold Gas Supply Pressure
(millivolt models)
Fuel #LowHigh
Natural
Gas
Propane
(Lo) 2.2" WC
(.55 kPa)
(Lo) 6.3" WC
(1.57 kPa)
(Hi) 3.5" WC
(.87 kPa)
(Hi) 10.0" WC
(2.49 kPa)
Table 4
3
Manifold Gas Supply Pressure
(electronic models)
Fuel #Fixed
Natural Gas
Propane
3.5" WC
(.87 kPa)
10.0" WC
(2.49 kPa)
Table 5
Test gauge connections are provided on the
front of the millivolt gas control valve, identifi ed IN for the inlet and OUT for the manifold
side (see Figure 2 on Page 5). A 1/8" NPT Test
gauge connection is provided at the inlet and
outlet (manifold) ports on the electronic gas
control valve (see Figure 3 on Page 5).
These appliances must be isolated from the
gas supply piping system (by closing their individual manual shut-off valve) during any
pressure testing of the gas supply piping
system at test pressures equal to or less than
1/2 psig (3.5 kPa).
These appliances and their individual shut-off
valves must be disconnected from the gas
supply piping system during any pressure
testing of that system at pressures greater
than 1/2 psig (3.5 kPa).
Orifi ce Sizes - Sea Level to High Altitude
(All Models)
These appliances are tested and approved for
installations at elevations of 0-4500 feet (0-1372
meters) above sea level using the standard burner
orifice sizes (marked with an "*" in Table 6). At
the time of installation, it must be determined
if the appliance needs to be derated. Contact
your local gas supplier for deration requirements
for your area.
Deration - At higher elevations, the amount of
BTU fuel value delivered must be reduced by
either using gas that has been derated by the gas
company or by changing the burner orifi ce to a
smaller size as regulated by the local authorities
having jurisdiction and by the (USA) National
Fuel Gas Code NFPA 54 / ANSI Z223.1 - latest
edition or, in Canada, the CAN1-B149.1 and .2
codes - latest edition.
Burner Orifi ce Sizes (all models)
Elevation
Feet (meters)
0-4500
(0-1372)
* Standard size installed at factory
• Part /Cat. Number
Natural
Gas
drill size (inches)
#37 (.104")
24M10 •
*
Propane
Gas
drill size (inches)
1.55
mm
(.061")
42M79 •
*
Table 6
Burn-in Period
During the fi rst few fi res of this appliance there
will be some odor due to the curing of the
paint and burning off of lubricants used in the
manufacturing process.
Depending on your use, the burn-in period may
take a few hours or a few days.
KEEP YOUR HOUSE WELL VENTILATED
DURING THE CURING PROCESS. THE ODOR
AND HAZE EMITTED DURING THE CURING
PROCESS CAN BE QUITE NOTICEABLE AND
MAY SET OFF A SMOKE DETECTOR.
If an optional blower is installed, Do not turn it
on during the Burn-In period.
A white fi lm may develop on the glass front
during the fi rst few fi res as part of the curing
process. The glass should be kept clean during
the fi rst two weeks of use to prevent the fi lm from
baking on (making it very diffi cult to remove).
See Cleaning Glass on Page 5.
Gas Control Compartment Access
The gas controls can be found behind the control
compartment access panel.
To open the control compartment access panel,
actuate the spring-loaded magnetic catches
securing the panel. First, depress the outer top
right corner of the panel until the catch "pops"
the door free. Then, gently pull the door forward
until the left top corner "pops" free, allowing the
panel to swing out and down to open.
On millivolt systems, the piezo igniter, HI/LO
fl ame adjustment knob, and pilot and main
gas OFF/ON control knob are located below
the glass panel enclosure. The gas valve for
electronic systems is also located below the
glass enclosure panel. See Figure 1.
To ease door closure, depress the catches to
place them in their retracted position, then
close the door.
OFF/PILOT/ON (gas control knob)
HI/LO (fl ame height
control knob)
OFF/ON Switch
Hinge Pin
Control
Compartment Access panel
Piezo Igniter
Figure 1 - Gas Control Compartment Access
OPERATION AND CARE OF YOUR
APPLIANCE
The standard controls for appliance operation
are located behind the hinged drop-down panel
below the appliance front glass enclosure panel
(see Figure 1). Optional control switches are
also available (see Page 13 - Remote Wall Switch, Remote Control or Wall Thermostat).
Operation of millivolt and electronic gas control systems are different. Before lighting and
operating your appliance determine if you have
a millivolt or electronic appliance. Familiarize
yourself with the gas control valve that your
appliance uses. Refer to Figure 1 for access
to the gas control valve.
Millivolt Appliances - Appliances with
Millivolt systems will be fi tted with the gas
control valve shown in Figure 2.
Electronic Appliances - Appliances with
electronic systems will be fi tted with the
electronic valve shown in Figure 3.
Millivolt Appliances -
To light millivolt appliances refer to the detailed
lighting instructions found on Page 17. Millivolt
appliance lighting instructions may also be
found on the pull out lighting instruction labels
attached to the gas control valve.
Millivolt appliances are fi tted with an OFF/ON
Rocker Switch located behind the control
compartment access panel, below the appliance front glass enclosure panel (see Figure 1
for location). Once the pilot is lit, the OFF/ON
rocker switch will control the appliance OFF/ON
burner operation. To operate: Toggle the switch
between its ON and OFF positions.
If your millivolt appliance is equipped with an
optional remote switch kit (wall switch, remote
control or wall thermostat) and the pilot is lit,
the appliance main burner may be turned on
and off using the optional switch. When using
an optional remote switch, turn off the standard
OFF/ON switch.
Note:The gas supply
line must be installed
in accordance with
building codes by a
qualifi ed installer
approved and/or
licensed as requed
by the locality. In
the Commonwealth
of Massachusetts,
installation must
be performed
by a licensed
Gas Flex Line
Gas Valve
plumber or gas
fi tter.
4
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
SIT Millivolt Gas Valve
HI/LO Variable
Flame Height
Adjustment
T
P
HT
TPT
H
L
O
T
Pilot Adjustment
Screw
Gas
Outlet
Terminals
TPTH,TP & TH
ON
OFF
Manifold Pressure Tap
P
I
OFF/ON
(burner)
Note: The piezo igniter and burner
OFF/ON switch are located below
glass panel (see Figure 1).
Inlet Pressure Tap
I
H
L
O
W
Main Gas
Control Knob
OFF/PILOT/ON
TPTH TP TH
HI/LO Variable
Flame Height
Adjustment
IN
OUT
F
F
O
P
I
L
it
O
T
O
N
Gas
Inlet
Main Gas
Control Knob
OFF/PILOT/ON
IGNITER
Figure 2
Honeywell Electronic Gas Valve
Manifold Pressure
Port
I
G
N
I
T
ER
Figure 3
Note: To prevent excessive resistance in burner
circuit (which can cause burner operation problems), only one burner control switch should be
wired to valve. Therefore, if an optional control
switch is installed, the standard Off/On switch
and wires should be removed.
Electronic Appliances -
To light electronic appliances refer to the detailed
lighting instructions found on Page 19.
Electronic appliance lighting instructions may
also be found on the pull out lighting instruction
labels attached to the gas control valve.
C
O
N
T
R
NO
O
FFO
L
ON / OFF Switch
Inlet
Pressure
Port
NI
PSI
Electronic Gas
Control Valve
Once the pilot is lit, if your electronic appliance is
equipped with an optional burner control switch
kit the appliance main burner may be turned on
and off using the optional switch (See optional
accessories on Page 13 - Wall Switch, Wall
variable gas control valve. Flame height for
these models may be adjusted through a
range between fi xed low and high settings
while the appliance is in operation. Adjust
the fl ame height as desired after lighting the
appliance by rotating the variable adjustment
control knob (HI/LO) located on the front of
the valve (refer to Figure 2).
2. During the fi rst initial burns of these appli-
ances, there will be some odor emitted (see
Burn-In Period on Page 4).
3. Keep the lower control compartment clean
by vacuuming or brushing at least twice a
year. More frequent cleaning may be required
due to excessive lint from carpeting, bedding
materials, pet hair, etc. It is very important
that the control compartments, burners
and circulating air passageways of the
appliance are kept clean.
4. Always turn off gas to the pilot (millivolt
appliances) and let the appliance cool down
before cleaning. Before re-lighting, refer
to the lighting instructions in this manual.
Lighting instructions may also be found
on the pull out lighting instruction labels
attached to the gas control valve.
5. Always keep the appliance area clear and
free from combustible materials, gasoline
and other fl ammable liquids.
6. Remember, Millivolt appliances have a continu-
ous burning pilot fl ame. Exercise caution when
using products with combustible vapors.
MAINTENANCE
(See Maintenance Schedule, Page 21)
Refer to the maintenance schedule for maintenance
tasks, procedures, periodicity and by whom they
should be performed. Always verify proper operation of the appliance after servicing.
WARNING
Turn off gas and electrical power
before servicing the appliance.
CAUTION
Wear gloves and safety Glasses
for protection while doing
required maintenance
.
IMPORTANT
Always verify proper operation
after servicing.
Before re-lighting the fi replace, refer to the
lighting instructions in this manual. Instructions are also found on pull-out panels
located below the glass door in the control
compartment.
Inspect Venting System
The appliance and venting system should be
thoroughly inspected before initial use and at
least annually by a qualifi ed service technician
(inspection should include ensuring that exhaust
or intake passages are unobstructed and vent
components are properly assembled and not
damaged). If the venting system is disassembled
for any reason, a qualifi ed service technician
should follow vent installation instructions for
proper reassembly and proper sealing of the
venting system components. However, more
frequent periodic inspections and cleanings
should be performed by the homeowner.
Clean Lower Control Compartment
Keep lower control compartment clean by
vacuuming or brushing it out at least twice a
year (also clean the air venturi with a brush or
wire). More frequent cleaning may be required
due to accumulation of lint from carpeting,
bedding materials, pet hair, spider webs, etc. It
is very important that control compartments,
burners, circulating air passageways and air
venturi on the appliance are NOT obstructed
in any way.
IMPORTANT
It is imperative that the control
compartment, burners and circulating air passage ways of the
appliance be kept clean.
Cleaning Glass
(see Front Glass Enclosure Panel, Removal
and Installation on Page 7). Note: Clean glass
after fi rst two weeks of operation (after Burn-In
period is over) and then only when necessary
and when the fi replace is cool. Wipe surface
with clean, dampened, soft cloth. Follow with
dry, soft towel as desired. Take care not to
scratch the glass surface.
The viewing glass should be cleaned periodically to remove any build-up caused from the
following:
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
5
IMPORTANT
Do not use abrasive cleaners
on glass. Never clean the glass
when it is hot.
• During start-up, it is normal for condensation to form on the inside of the glass (this
condensation and fog will usually disappear
in a few minutes). The moisture can cause
lint, dust and other airborne particles to cling
to the glass surface.
• Initial curing of the high temperature paint
and burning off of lubricants used in the
manufacturing process may result in a fi lm
on the glass.
• A white coating may form on the glass
as a result of impurities and minerals in
the fuel.
It is recommended that the glass be cleaned
two or three times during each heating season,
depending on the circumstances present. The
following cleaning solutions are approved for
use to clean glass:
• Non-ammonia based household cleaner
• 50%-50% mix of white vinegar & water
• gas fi replace/stove glass cleaner
Inspect Glass Gasket - Visually inspect the
gasket on the backside of the glass enclosure
panels. The gasket surface must be clean, free
of irregularities and seated fi rmly.
Clean Logs And Burner
Carefully remove the logs (use care when handling the fi ber logs, as they become quite fragile
after curing). Vacuum out any foreign matter
(lint, carbon, etc.) on the burner. Ensure the
burner ports are “open.” Remove any carbon
deposits from the under side of the logs using
a vacuum cleaner, or a soft bristled brush (i.e.
paint brush). Note: Improper positioning of
logs can create carbon build-up and will alter
the performance of the appliance.
Replacing Logs -
If the logs become damaged by accident or
improper handling and need replacement, use
only the proper replacement logs from manufacturer (see Page 24 for ordering information).
Re-Install Embers, Logs and Vermiculite
- Carefully follow placement instructions on
Pages 8 to 10). All logs should fi t onto corresponding pins and/or log stoppers. This will
ensure a proper fl ame and safe combustion.
Inspect Wiring
Refer to wiring diagrams on Page 12.
WARNING
Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation. Verify proper operation
after servicing.
Inspect and clean all wire connections. Ensure
that there is no melting or damage. Inspection
should include:
• Terminals at the Valve
• OFF/ON Switch
• (Optional Control Switch) Wall Thermostat,
Remote Control or Remote Wall Switch Kit
Inspect Burner Flame Appearance
Ensure that the burner flame appearance
resembles the fl ame shown in Figure 13 and
as described in Flame Appearance and Sooting
on Page 10. The Homeowner must contact
a qualifi ed service technician at once if any
abnormal condition is observed.
Small Area Paint Touch-up
The fi nish of the appliance is a high quality powdercoat. Only use factory supplied
powdercoat paint kit for touch-ups. Paint is
available at your local authorized Lennox Hearth
Products dealer , cat. no. 90L74. Never attempt
to paint a hot fi replace.
Do not attempt to repaint the appliance until the
fi nish is completely cured (see Burn-In Period
on Page 4). If the surface later becomes stained
or marred, it may be lightly sanded and touched
up with spray paint.
6
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Front Glass Enclosure Panel, Removal
and Installation
WARNING
Do not operate appliance with the
glass front removed, cracked or
broken. Replacement of the glass
should be done by a licensed or
qualifi ed service technician.
WARNING
Do not attempt to substitute the
materials used on this door, or
replace cracked or broken glass
with any materials other than
those provided by the appliance
manufacturer.
WARNING
Handle this glass with extreme
care! Tempered glass is susceptible to damage – do not scratch
or handle roughly while reinstalling the glass door frame.
These are direct-vent appliances. They are
designed to operate only when the front glass
enclosure panel is installed. Generally the front
glass enclosure panel should not be removed
except to gain access to the components within
the fi rebox, and the appliance may only be operated without the front glass enclosure panel
in place for very brief periods of time during
appliance checkout and adjustment. Note: The
fl ame appearance will be diminished while the
front glass enclosure panel is removed.
During this appliance checkout and adjustment period, a potential safety hazard exists
- EXERCISE EXTREME CAUTION to prevent
the occurrence of any burn injuries from the
exposed fl ames or hot sur faces. Also note, that
while the front glass enclosure panel (or any of
the panels) is removed, the fl ame appearance
will appear to be smaller than normal.
Lower Compartment
Door and Hinge
Top Flange on
Glass Door
Glass Door
Removing Glass Enclosure Panels
(see Figure 4)
1. Remove the top louver assembly or radiant
panel by pulling it out and off.
2. Open the control compartment access panel.
by actuating the spring-loaded magnetic
catches securing the panel (gently depress the
outer top corners of the louvered or radiant
panel until the catches "pop" the door free,
allowing it to swing out and down to the open
position).
3. Locate the two (2) latches at the top of the
control compartment. To disengage the two
latches from the bottom vee-fl ange of the
glass enclosure panel, reach for the handles
located towards the back of the latches and
pull the handles down toward the front of
the appliance.
4. Swing the bottom of the door out and raise
it slightly to lift the top fl ange of the door
frame away from the appliance.
Installing Glass Enclosure Panels
(see Figure 4)
1. Visually inspect the gasket on the backside of
the panels. The gasket surface must be clean,
free of irregularities and seated fi rmly.
WARNING
Do not attempt to touch the front
enclosure glass with your hands
while the fi replace is in use.
WARNING
The glass door of this appliance must only be replaced as a
complete unit as provided by the
manufacturer. Do not attempt to
replace broken, cracked or chipped
glass separately.
Bottom Vee-fl ange
Glass Door
Glass Door Latch
Firebox Floor
Figure 4 - INSTALLING GLASS DOOR
2. Position the glass enclosure panel in front of
the fi rebox opening at a 45 degree angle and
engage the top fl ange over the lip at the top
of the fi rebox opening. See Figure 4.
3. Swing the glass enclosure panel down and
back. Ensure the gasket seats evenly as the
panel draws shut. Engage the Vee-fl ange at
the bottom of the panel with the latches and
close the latches to secure the panel.
4. Close the bottom control compartment
access panel.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
7
INSTALL GRATE, VERMICULITE, GLOWING EMBERS AND LOGS
LOG SET - IDENTIFICATION
LOG SET
Catalog Number
* Item
A
B
C
D
E
F
* Item "letters" above correspond to photos on right
REFERENCE
Firebox Accessories / Parts
Cat. No.Model No.Description
88L53FGEBag of Glowing Embers
H3696
H3210
Description
Log, Center
Log, Left Rear
Log, Left Front
Log, Right Rear
Log, Top Center
Log, Front Center
(1 oz. rockwool)
Vermiculite, Bag (2 liters)
Bottom View of Logs (in packaging)
C
A
B
F
D
E
Top View of Logs
B
E
WARNING
The size and position of the log
set was engineered to give the
appliance a safe, reliable and
attractive fl ame pattern. Any
attempt to use a different log
set in the fi replace will void
the warranty and will result in
incomplete combustion, sooting, and poor fl ame quality.
Glowing Embers
Separate into Quarter
Size (separate) Pieces
Bag of Glowing
Embers (rockwool)
D
A
C
F
Top View of Logs - Installed
B
D
E
C
Figure 5
8
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
(Valve Access Side)
F
A
Loading...