Lennox MPB35ST-NE, MPB35ST-PM, Merit Plus MPB35ST-NM, Merit Plus MPB35ST-NE, Merit Plus MPB35ST-PM owner's Manual

Page 1
HOMEOWNER'S CARE AND OPERATION INSTRUCTIONS
MERIT® PLUS SERIES
B-VENT GAS FIREPLACES
P/N 875,024M REV. NC 04/2005
MODELS
Millivolt Models Electronic Models
MPB35ST-NM MPB35ST-NE MPB35ST-PM
WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO­SION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY: Do not store or use gasoline or other fl ammables or liquids in the vicinity of this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow your gas suppliers instructions.
• If your gas supplier cannot be reached, call the fi re department.
Installation and service must be performed by a qualifi ed installer, service agency or the gas supplier.
A French manual is available upon request. Order P/N 875,024CF
Ce manuel d’installation est disponible en francais, simplement en faire la demande. Numéro de la pièce 875,024CF
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
Listing Agency
OTL Report No. 116-F-27-5
Page 2
CONGRATULATIONS!
In selecting this LENNOX B-Vent Gas Appliance you have chosen the fi nest and most dependable fi replace to be found anywhere. Its a beautiful, prestigious alternative to a wood burning fi replace. Welcome to a Family of tens of thousands of satisfi ed LENNOX Fireplace Owners.
Please carefully read and follow all of the instructions found in this manual. Please pay special attention to the safety instructions provided in this manual. The Homeowner's Care and Operation Instructions included here will assure that you have many years of dependable and enjoyable service from your LENNOX product.
TABLE OF CONTENTS
Introduction .......................................page 2
General Information ...........................page 2
Gas Controls/Control Compartment,
Access .............................................page 4
Operation/Care of Your Appliance ......page 4
Variable Flame Adjustment .................page 5
Venting Action and (spill switch) .......page 5
Outside Combustion Air Control ........page 6
Maintenance .......................................page 6
Front Glass Enclosure Panel,
Removal and Installation ..................page 7
Logs, Vermiculite & Ember Placement page 8
Burner Adjustments ...........................page 10
Maintenance Schedule .......................page 11
Troubleshooting Guide – Millivolt ......page 12
Troubleshooting Guide – Electronic ...page 12
Millivolt Appliance Checkout ..............page 14
Electronic Appliance Checkout ...........page 14
Wiring Diagrams ................................page 14
Warranty ............................................page 14
Product Reference Information ..........page 14
Accessory Components .....................page 15
Lighting Instructions – Millivolt .........page 18
Lighting Instructions – Electronic ......page 19
Replacement Parts List ......................page 20
INTRODUCTION
The millivolt appliances have a millivolt gas control valve witha piezo ignition system which provides safe, effi cient operation.
The electronic appliances have an electronic intermittent pilot system provides safe, effi cient operation. External electrical power is required to operate these units.
LISTING AS FOLLOWS:
These appliances comply with National Safety Standards and are tested and listed by Omni­Test Laboratories (Report No. 116-F-27-5) to ANSI Z21.50 - 2000 (in Canada, CSA 2.22
- 2000), and CAN/CGA-2.17-M91 in both USA and Canada, as vented gas fi replaces.
2
Installation must conform to local codes. In the absence of local codes, installation must comply with the current National Fuel Gas Code, ANSI Z223.1 (NFPA 54). (In Canada, the current CAN/CGA B149 installation code.) Electrical wiring must comply with local codes. In the absence of local codes, installation must be in accordance with the National Electrical Code, NFPA 70 - (latest edition). (In Canada, the current CSA C22.1 Canadian Electric Code.)
GENERAL INFORMATION
Note: Installation and repair should be per­formed by a qualifi ed service person. The appliance should be inspected annually by a qualifi ed professional service technician. More frequent inspections and cleanings may be required due to excessive lint from carpeting, bedding material, etc.
IMPORTANT
It is imperative that the control compartment, burners and circulating air passage ways of the appliance be kept clean. See Maintenance instructions on Pagex 6.
Provide adequate clearances around air open­ings and adequate accessibility clearance for service and proper operation. Never obstruct the front openings of the appliance.
Due to high temperatures the appliance should be located out of traffi c and away from furniture and draperies. Locate furniture and window coverings accordingly.
These appliances are designed to operate on natural or propane gas only. The use of other fuels or combination of fuels will degrade the performance of this system and may be dangerous.
Millivolt Models - BTU Input
Millivolt models come standard with the manu­ally-modulated gas valve; fl ame appearance and heat output can be controlled at the gas valve. Input of for these models is shown in the fol­lowing table:
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Input (BTU) Manually-Modulated Gas
Valves (millivolt models)
Models Fuel
Type
MPB35ST-NM Nat. Gas
MPB35ST-PM Propane
Input Rate
(BTU / HR)
30,000 high
23,000 low
28,000 high
22,000 low
Table 1
Electronic Models -
Electronic models have a fi xed rate gas valve. Input of electronic models is shown in the following table:
Input (BTU) - Fixed Rate
(electronic models)
Models Fuel
Type
MPB35ST-NE Nat. Gas 30,000
MPB35ST-PE
(if fi eld converted)
Pro. Gas 28,000
Input Rate (BTU / HR)
Table 2
Gas Pressure -
Tables 3, 4 and 5 show the appliances' gas pressure requirements.
Inlet Gas Supply Pressure
(all models)
Fuel # Minimum Maximum
Natural Gas
Propane
5.0" WC
(1.24 kPa)
11.0" WC
(2.74 kPa)
10.5" WC
(2.61 kPa)
13.0" WC
(3.23 kPa)
Table 3
Manifold Gas Supply Pressure
(millivolt models)
Fuel # Low High
Natural
Gas
Propane
(Lo) 2.2" WC
(.55 kPa)
(Lo) 6.3" WC
(1.57 kPa)
(Hi) 3.5" WC
(.87 kPa)
(Hi) 10.0" WC
(2.49 kPa)
Table 4
Manifold Gas Supply Pressure
(electronic models)
Fuel # Fixed
Natural Gas
Propane
3.5" WC
(.87 kPa)
10.0" WC
(2.49 kPa)
Table 5
Page 3
Test gauge connections are provided on the front of the millivolt gas control valve, identifi ed IN for the inlet and OUT for the manifold side (see Fig- urex 2 on Pagex 4 ). A 1/8" NPT Test gauge con- nection is provided at the inlet and outlet side of the electronic gas control valve (see Figurex 3 on Pagex 5).
These appliances must be isolated from the gas supply piping system (by closing their individual manual shut-off valve) during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).
These appliances and their individual shut-off valves must be disconnected from the gas supply piping system during any pressure testing of that system at pressures greater
than 1/2 psig (3.5 kPa).
Orifi ce Sizes - Sea Level to High Altitude (All Models)
These appliances are tested and approved for installations at elevations of 0-4500 feet (0-1372 meters) above sea level using the standard burner orifice sizes (marked with an "*" in Table 6 ). For elevations above 4500 feet, these appliances must be properly "derated" by the gas supplier or qualifi ed service technician (usually done at the time of installation).
Note: Derated (defi nition) - Replacing burner orifi ce with a smaller one to reduce BTU input. The installation of this appliance must be accord­ing to the regulations of the local authorities having jurisdiction and, in the USA, the National Fuel Gas Code NFPA 54 / ANSI Z223.1 - latest edition or, in Canada, the CAN1-B149.1 and .2 codes - latest edition.
Burner Orifi ce Sizes (all models)
Elevation
Feet (meters)
0-4500
(0-1372)
* Standard size installed at factory
• Part /Cat. Number
Table 6
Burn-in Period
During the fi rst few fi res of this appliance there will be some odor due to the curing of paint and burning off of lubricants used in the manufacturing process.
Depending on your use, the burn-in period may take a few hours or a few days.
Natural
Gas
drill size (inches)
#37 (.104")
24M1001 •
*
Propane
Gas
drill size (inches)
1.55
mm
(.061")
42M7901 •
*
KEEP YOUR HOUSE WELL VENTILATED DURING THE CURING PROCESS. THE ODOR AND HAZE EMITTED BY THE CURING PROCESS CAN BE QUITE NOTICEABLE AND MAY SET OFF A SMOKE DETECTOR.
A white fi lm may develop on the glass front during the fi rst few fi res as part of the curing process. The glass should be kept clean during the fi rst two weeks of use to prevent the fi lm from baking on (making it very diffi cult to remove). See Glass Cleaning on Page 8.
SAFETY & WARNIING INFORMATION
WARNING
If the information in this manual is not followed exactly, a fi re or explosion may result causing prop­erty damage, personal injury or loss of life.
WARNING
Failure to comply with the instal­lation and operating instructions provided in this document will result in an improperly installed and operating appliance, voiding its warranty. Any change to this appliance and/or its operating controls is dangerous. Improper installation or use of this appli­ance can cause serious injury or death from fi re, burns, explosion or carbon monoxide poisoning.
IMPORTANT
These appliances must not be connected to a chimney or fl ue serving a separate solid fuel burning appliance.
WARNING
Do not use these appliances if any part has been under water. Immediately call a qualifi ed, professional service technician to inspect the appliances and to replace any parts of the control system and any gas controls which have been under water.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
WARNING
Do not attempt to alter or modify the construction of the appli­ance or its components. Any modifi cation or alteration may void the warranty, certifi cation and listings of this unit.
WARNING
Improper installation, adjust­ment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualifi ed installer, service agency or the gas supplier.
WARNING
These fireplaces are vented heaters. Do not burn wood or other material in these appli­ances.
WARNING
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certifi ed kit is used.
WARNING
Children and adults should be alerted to the hazards of high surface temperatures. Use caution around the appliance to avoid burns or clothing igni­tion. Young children should be carefully supervised when they are in the same room as the appliance.
Note: An Optional Screen Heat Guard for the glass is available (see Page 15 for ordering infor­mation).
3
Page 4
WARNING
WARNING
OPERATION AND CARE OF YOUR APPLIANCE
Carbon monoxide poisoning: early signs of carbon monoxide poisoning are similar to the fl u with headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immediately. Turn off the gas supply to the appliance and have it serviced by a quali­fi ed professional, as it may not be operating correctly.
B-Vent appliances are not designed to operate in negatively pressured environments (pressure within the home is less than pressures outside). Signifi cant negatively pressured environments caused by weather, home design, or other devices may impact the operation of these appliances. Negative pressures may result in poor fl ame appearance, sooting, damage to property and/or severe personal
WARNING
injury. Do not operate these appli­ances in negatively pressured
Any safety guard or screen removed for servicing the appli­ance must be replaced prior to operating the appliance.
environments. Providing adequate ventilation to the appliance for combustion air will eliminate a negative pressure environment.
WARNING
Do not place clothing or other fl ammable materials on or near appliance.
The standard controls for appliance operation are located behind the hinged drop-down panel below the appliance front glass enclosure panel (see Figure 1). Optional control switches are also available (see Page 15 - Remote Wall Switch or Remote Control).
Operation of millivolt and electronic gas con­trol systems are different. Before lighting and operating your appliance determine if you have a millivolt or electronic appliance. Familiarize yourself with the gas control valve that your appliance uses. Refer to Figure 1 for access to the gas control valve.
Millivolt Appliances - Appliances with
Millivolt systems will be fi tted with the gas control valve shown in Figure 2.
Electronic Appliances - Appliances with
electronic systems will be fi tted with the electronic valve shown in Figure 3.
Millivolt Appliances -
To light millivolt appliances refer to the detailed lighting instructions found on Page 18 . Millivolt
appliance lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve.
Gas Control Compartment Access
The gas controls can be found behind the control compartment access panel.
To open the control compartment access panel, actuate the spring-loaded magnetic catches secur­ing the panel. First, depress the outer top right corner of the panel until the catch "pops" the door free. Then, gently pull the door forward until the left top corner "pops" free, allowing the panel to swing out and down to open.
On millivolt systems, the piezo igniter, HI/LO fl ame adjustment knob, and pilot and main gas OFF/ON control knob are located below the glass panel enclosure. The gas valve for electronic systems is also located below the glass enclosure panel. See Figure 1.
To ease door closure, depress the catches to place them in their retracted position, then close the door.
OFF/PILOT/ON (gas control knob)
HI/LO (fl ame height
control knob)
OFF/ON Switch
Hinge Pin
Control Compartment Access panel
Note: The gas supply line must be installed in accordance with building codes by a qualifi ed installer approved and/or licensed as required by the locality. In the Commonwealth of Massachu­setts, installation must be performed by a licensed plumber or gas fi tter.
Piezo Igniter
Gas Flex Line
Gas Valve
Figure 1 - Gas Control Compartment Access
SIT Millivolt Gas Valve
HI/LO Variable Flame Height Adjustment
T P
HT
TPT H
Pilot Adjustment Screw
Manifold Pressure Tap
P
I
L
O
T
Note: The piezo igniter is located below the valve (see Figure 1).
Gas Outlet
Terminals
TPTH,TP & TH
Inlet Pressure Tap
OUT
I
H
L
O
W
HI/LO Variable Flame Height Adjustment
F
F
O
it
O
N
Main Gas Control Knob
OFF/PILOT/ON
TPTH TP TH
IN
P
I
L
O
T
Gas Inlet
Main Gas
Control Knob
OFF/PILOT/ON
Figure 2
4
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Page 5
Millivolt appliances are fi tted with an OFF/ON Rocker Switch located behind the control compartment access panel, below the appli­ance front glass enclosure panel (see Figure 1 for location). Once the pilot is lit, the OFF/ON rocker switch will control the appliance OFF/ON burner operation. To operate: Toggle the switch between its ON and OFF positions.
If your millivolt appliance is equipped with an optional remote switch kit (wall switch or remote control) and the pilot is lit, the appliance main burner may be turned on and off using the optional switch. When using an optional remote switch, turn off the standard OFF/ON switch.
Note: To prevent excessive resistance in burner circuit (which can cause burner operation prob­lems), only one burner control switch should be wired to valve. Therefore, if an optional control switch is installed, the standard Off/On switch and wires should be removed.
Electronic Appliances -
To light electronic appliances refer to the detailed lighting instructions found on Pagex
19. Electronic appliance lighting instructions may also be found on the pull out lighting instruc­tion labels attached to the gas control valve.
Once the pilot is lit, if your electronic appliance is equipped with an optional burner control switch kit the appliance main burner may be turned on and off using the optional switch (See Optional Accessories on Pagex 15 - wall switch, or remote control Receiver).
Honeywell Electronic Gas Valve
Manifold Pressure Port
Figure 3
I G
N I
T ER
C O N T R
NO
O
FFO
L
ON / OFF Switch
Inlet Pressure Port
NI
PSI
Electronic Gas Control Valve
Variable Flame Height Adjustment ( Millivolt Appliances only)
1. All Millivolt appliances are equipped with a
variable gas control valve. Flame height for these models may be adjusted through a range between fi xed low and high settings while the appliance is in operation. Adjust the fl ame height as desired after lighting the appliance by rotating the variable adjustment control knob (HI/LO) located on the front of the valve (refer to Figure 2 ).
2. During the fi rst initial burns of these appli-
ances, there will be some odor emitted (see Burn-In Period on Page 3 ).
3. Keep the lower control compartment clean
by vacuuming or brushing at least twice a year. More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, pet hair, etc. It is very important
that the control compartments, burners and circulating air passageways of the appliance are kept clean.
4. Always turn off gas to the pilot (millivolt
appliances) and let the appliance cool down before cleaning. Before re-lighting, refer to the lighting instructions in this manual. Lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve.
5. Always keep the appliance area clear and
free from combustible materials, gasoline and other fl ammable liquids.
6. Remember, Millivolt appliances have a con-
tinuous burning pilot fl ame. Exercise cau­tion when using products with combustible vapors.
VENT OPERATION TEST
A vent operation test is required as part of the installation to verify that proper venting condi­tions exist and should be done periodically to ensure nothing has changed that would affect proper venting of the appliance.
Procedure:
1. ENSURE APPLIANCE IS OFF (PILOT ONLY) AND COOL.
2. Open both latches on one of the glass enclosure doors and slightly prop it open at the bottom (approx. 1/4” gap). See Figure 6 on Page 9.
3. Turn on all the exhaust fans in the dwelling (and any other appliances which remove air from the dwelling, such as a furnace or clothes dryer, etc.).
4. Ensure that all the doors and windows in the room where the fi replace is located are closed.
5. Light the appliance (see Lighting Instruc- tions, Pages 18 & 19 ). Adjust fl ame height to highest setting and operate for approximately 5-10 minutes. Do not leave appliance unattended.
6. Take a smoke producing device and move it along the bottom edge of the glass door (where it is cracked open). If smoke is drawn into the fi rebox, the vent operation is adequate.
IF THE SMOKE IS NOT DRAWN INTO
THE FIREBOX, TURN THE APPLIANCE OFF AND CALL A QUALIFIED SERVICE TECHNICIAN.
SPILL SWITCH OPERATION
Manual-Reset (safety limit) Spill Switch
This appliance is equipped with a (safety limit) spill switch that is designed to "trip" and discon-
nect the burner circuit if fl ue spillage occurs (because of improper venting of combustion products or vent blockage). If, during appliance operation, the burner fl ame goes out (indepen­dently of the burner OFF/ON wall switch), it may be due to the operation of this (safety limit) spill switch. If this switch "trips" it will need to be manually reset by pressing the reset button on switch (see Figure 4 ).
Procedure to Reset (safety limit) Spill Switch
ALLOW APPLIANCE TO COOL COMPLETELY BEFORE ACCESSING AND RESETTING
To access the spill switch:
1. Pull off the top louvered panel.
2. Locate and press the red reset button on the switch (it will click & lock in).
The appliance should then relight and remain lit. If this does not occur, turn off the appliance
and call a qualifi ed service technician.
Press Reset Button on Spill Switch
Remove Top Louvered Panel (or optional radiant panel, if applicable)
Figure 4 - Spill Switch
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
5
Page 6
Outside Combustion Air Controls
Many appliances are equipped, when installed, with an outside (make-up air) vent system that is designed to provide the appliance with outside make-up air for combustion when in operation.
The outside air control lever for the outside air system is standard on all appliances but should not be operated if the complete system is not installed. Refer to Figure 5. When the complete outside air vent system is installed, the installer will remove the securing screw from the combustion air control lever located on the right side of the fi replace opening.
If the securing screw has not been removed and you have reason to believe that you have a complete outside air system, contact your distributor to have your appliance inspected for the presence of the complete system. DO NOT assume that you have this system in place.
Outside Air Control Lever
and Securing Screw Location
Glass Front
Outside Air Control Lever with Stop Behind
Securing Screw
Inspect Venting System
The appliance and venting system should be thoroughly inspected before initial use and at least annually by a qualifi ed service technician (inspection should include ensuring that exhaust or intake passages are unobstructed and vent components are properly assembled and not dam­aged). If the venting system is disassembled for any reason, a qualifi ed service technician should follow vent installation instructions for proper reassembly and proper sealing of the venting system components. However, more frequent periodic inspections and cleanings should be
performed by the homeowner.
Clean Lower Control Compartment
Keep lower control compartment clean by vacu­uming or brushing it out at least twice a year (also clean the air venturi with a brush or wire). More frequent cleaning may be required due to accumula­tion of lint from carpeting, bedding materials, pet hair, spider webs, etc. It is very important that
control compartments, burners, circulating air passageways and air venturi on the appliance are NOT obstructed in any way.
WARNING
Do not operate the shutoff lever unless a complete outside com­bustion air system has been installed with your appliance.
To open the outside air shutter, open the bottom control access panel, and pull the outside air control lever all the way out. The outside air shutter should be fully open when the fi replace is in use and completely closed when the fi re­place is not being used. Closing it when not in use will prevent outside cold air from entering the dwelling.
The hand operated outside air control lever is located on the right side of the fi replace open­ing. See Figure 5.
To open the outside air , open the bottom control access panel, reach into the gap between the fi rebox bottom and pull the outside air control lever all the way out.
The outside air shutter should be fully open when the fi replace is in use and completely closed when the fi replace is not being used. Closing it when not in use will prevent outside cold air from entering the dwelling.
Operate the actuator through several cycles including the closed position. Ensuring proper operation and freedom of movement. Return the actuator arm to the closed position.
6
Control Compartment Access Panel
Figure 5
MAINTENANCE
(See Maintenance Schedule, Page 20 )
Refer to the maintenance schedule for maintenance tasks, procedures, periodicity and by whom they should be performed. Always verify proper opera­tion of the appliance after servicing.
WARNING
Turn off gas and electrical power before servicing the appliance.
CAUTION
Wear gloves and safety Glasses for protection while doing required maintenance
.
IMPORTANT
Always verify proper operation after servicing.
Before re-lighting the fi replace, refer to the lighting instructions in this manual. Instruc­tions are also found on pull-out panels located below the glass door in the control compartment.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Cleaning Glass
(see Front Glass Enclosure Panel, Removal and Installation on Page 9 ) Note: Clean glass after
fi rst two weeks of operation (after Burn-In period is over) and then only when necessary and when the fi replace is cool. Wipe surface with clean, dampened, soft cloth. Follow with dry, soft towel as desired. Take care not to scratch the glass surface.
The viewing glass should be cleaned periodically to remove any build-up caused from the fol­lowing:
IMPORTANT
Do not use abrasive cleaners on glass. Never clean glass when hot.
• During start-up, it is normal for condensation to form on the inside of the glass (this condensation and fog will usually disappear in a few minutes). The moisture can cause lint, dust and other air­borne particles to cling to the glass surface.
• Initial curing of the high temperature paint and burning off of lubricants used in the manufacturing process may result in a fi lm on the glass.
• A white coating may form on the glass as a result
of impurities and minerals in the fuel. It is recommended that the glass be cleaned two or three times during each heating season, depending on the circumstances present.
The following cleaning solutions are approved for use to clean glass:
• Non-ammonia based household cleaner
• 50%-50% mix of white vinegar & water
• gas fi replace/stove glass cleaner
Inspect Glass Gasket - Visually inspect the gasket on the backside of the glass enclosure panels. The gasket surface must be clean, free of irregularities and seated fi rmly.
Page 7
Cleaning Logs And Burner
Carefully remove the logs (use care when han­dling the fi ber logs, as they become quite fragile after curing). Vacuum out any foreign matter (lint, carbon, etc.) on the burner. Ensure the burner ports are “open.” Remove any carbon deposits from the under side of the logs using a vacuum cleaner, or a soft bristled brush (i.e. paint brush). Note: Improper positioning of logs can create carbon build-up and will alter the performance of the appliance.
Replacing Logs -
If the logs become damaged by accident or improper handling and need replacement, use only the proper replacement logs from manufac­turer (see Page 23 for ordering information).
Re-Install Embers, Logs and Vermiculite
- Carefully follow placement instructions on
Pages 9 to 12 ). All logs should fi t onto cor­responding pins and/or log stoppers. This will ensure a proper fl ame and safe combustion.
Inspect Wiring
Refer to wiring diagrams on Page 14.
WARNING
Label all wires prior to discon­nection when servicing con­trols. Wiring errors can cause improper and dangerous opera­tion. Verify proper operation after servicing.
Inspect and clean all wire connections. Ensure that there is no melting or damage. Inspection should include:
• Terminals at the Valve
• OFF/ON Switch
• (Optional Control Switch) Remote Control or Remote Wall Switch Kit
Inspect Burner Flame Appearance
Ensure that the burner flame appearance resembles the fl ame shown in Figure 15 and as described in Flame Appearance and Sooting on Page 13. The Homeowner must contact a qualifi ed service technician at once if any abnormal condition is observed.
Small Area Paint Touch-up
The fi nish of the appliance is a high qual­ity powdercoat. Only use factory supplied powdercoat paint kit for touch-ups. Paint is available at your local authorized Lennox Hearth Products dealer (cat. no. 90L74). Never attempt to paint a hot fi replace.
Do not attempt to repaint the appliance until the fi nish is completely cured (see Burn-In Period on Page 3 ). If the surface later becomes stained or marred, it may be lightly sanded and touched up with spray paint.
Front Glass Enclosure Panel
WARNING
Do not attempt to touch the front enclosure glass with your hands while the fi replace is in use.
WARNING
Do not operate appliance with the glass front removed, cracked or broken. Replacement of the glass should be done by a licensed or qualifi ed service technician.
WARNING
Handle this glass with extreme care! Tempered glass is suscep­tible to damage – do not scratch or handle roughly while rein­stalling the glass door frame.
WARNING
Do not attempt to substitute the materials used on this door, or replace cracked or broken glass with any materials other than those provided by the appliance manufacturer.
WARNING
The glass door of this appli­ance must only be replaced as a complete unit as provided by the manufacturer. Do not attempt to replace broken, cracked or chipped glass separately.
These fi replaces are designed to operate only with the glass enclosure panels properly installed. Generally the glass enclosure panels should not be removed except to gain access to the components within the fi rebox, and the appliance may only be operated without the front glass enclosure panel in place for very brief periods of time during initial appliance checkout and adjustment.
During this appliance checkout and adjust­ment period, a potential safety hazard exists
- EXERCISE EXTREME CAUTION to prevent the occurrence of any burn injuries from the exposed fl ames or hot surfaces. Also note, that while the front glass enclosure panel (or any of the panels) is removed, the fl ame appearance will appear to be smaller than normal.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Removing Glass Enclosure Panels (see Figure 6 )
1. Remove the top louver assembly or radiant panel by pulling it out and off.
2. Open the control compartment access panel by actuating the spring-loaded magnetic catches securing the panel (gently depress the outer top corners of the louvered or radiant panel until the catches "pop" the door free, allowing it to swing out and down to the open position).
3. Locate the two (2) latches at the top of the control compartment. To disengage the two latches from the bottom vee-fl ange of the glass enclosure panel, reach for the handles located towards the back of the latches and pull the handles down toward the front of the appliance.
4. Swing the bottom of the door out and raise it slightly to lift the top fl ange of the door frame away from the appliance.
Installing Glass Enclosure Panels (see Figure 6 )
1. Visually inspect the gasket on the backside of
the panels. The gasket surface must be clean, free of irregularities and seated fi rmly.
2. Position the glass enclosure panel in front of the fi rebox opening at a 45 degree angle and engage the top fl ange over the lip at the top of the fi rebox opening. See Figure 6.
3. Swing the glass enclosure panel down and back. Ensure the gasket seats evenly as the panel draws shut. Engage the Vee-fl ange at the bottom of the panel with the latches and close the latches to secure the panel.
4. Close the bottom control compartment access panel.
Lower Compartment Door & Hinge
Bottom Vee-fl ange
Glass Door
Figure 6
Glass Door Latch
Top Flange Glass Door
Glass Door (Enclosure Panel)
Firebox Floor
7
Page 8
RE-INSTALLING GRATE, VERMICULITE, GLOWING EMBERS AND LOGS
LOG SET - IDENTIFICATION
LOG SET
Catalog Number
* Item
A
B
C
D
E
F
* Item "letters" above correspond to photos on right
REFERENCE
Firebox Accessories / Parts
Cat. No. Model No. Description
88L53 FGE Bag of Glowing Embers
42363
H3210
Description
Log, Center
Log, Left Rear
Log, Left Front
Log, Right Rear
Log, Top Center
Log, Front Center
(1 oz. rockwool)
Vermiculite, Bag (2 liters)
Bottom View of Logs (in packaging)
C
A
B
F
D
E
Top View of Logs
B
E
WARNING
The size and position of the log set was engineered to give the appliance a safe, reliable and attractive fl ame pattern. Any attempt to use a different log set in the fi replace will void the warranty and will result in incomplete combustion, soot­ing, and poor fl ame quality.
Glowing Embers
Separate into Quarter
Size (separate) Pieces
Bag of Glowing
Embers (rockwool)
D
A
C
F
Top View of Logs - Installed
B
D
E
C
Figure 7
8
(Valve Access Side)
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
F
A
Page 9
READ LOG WARNINGS ON PAGE 9 BEFORE PROCEEDING
8. Place Log (B) as shown in Figure 10.
1. Remove front glass enclosure panel from appliance.
a. Open Control Compartment Access Panel (see Control Compart-
ment Access Instructions on Page 4.
b. Remove the glass panel enclosure (see Removing Glass Enclosure
Panel instructions on Page 9.
2. Remove the following from fi rebox; log set, embers (rockwool) and
vermiculite. Handle logs carefully to prevent breakage.
3. Ensure the Grate is properly installed in the fi rebox with the 4 legs
of the grate fi tting into the 4 dimples on the fi rebox fl oor.
4. Install Vermiculite - Place some vermiculite on the fi rebox fl oor around the grate (the entire bag of vermiculite will NOT be used). See Figure 15
on Page 13. DO NOT PLACE ANY VERMICULITE ON THE BURNER.
6. Placement of Glowing Embers -
Separate the Embers (rockwool) into pieces about the size of a quarter
(see Figure 7 ). Keep the pieces fl uffed up, not matted. Distribute these pieces over the surface of the burner, as shown in Figure 8. Do not use more than is necessary. Ensure that the main burner ports remain uncovered by the ember material.
Note: This appliance is provided with enough Glowing Embers for
several applications, do not use all that is in a new bag at one time. For best glowing effect, replace the ember material annually. Replacement Glowing Embers are available (order Catalog Number 88L53).
Place Embers on burner as shown.
Position Log (B) Against The Back Of The Grate Here
B
Position Groove at The Bottom Of Log (B) Over The Grate Here And Slide It Against The Back Of The Grate
Figure 10
9. Place Log (C) as shown in Figure 11.
(Valve Access Side)
Log (C) Lays Over Logs (A) and (B)
Figure 8
DO NOT PLACE EMBERS OVER GAS PORTS / AREAS CIRCLED
7. Place Log (A) on the grate as shown in Figure 9
A
B
C
Position The Groove in The Back of Log (C)
Figure 11
Against The Grate
10. Place Log (D) as shown in Figure 12.
Position And Slide Log (D) Against The
The Grate
Back Of
A
A
(Valve Access Side)
Position Groove At The Bottom Of Log (A) Over The Log Support Here
Position The Groove At The Bottom Of Log (A) Over The Grate And Slide It Forward Against The Grate Here
(Valve Access Side)
Figure 9
(Valve Access Side)
Figure 12
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
D
Place Log (D) Over The Flat Spot On Log (A)
Here
9
Page 10
10. Place Log (E) as shown in Figure 13.
Position round end of log (E) against the notch of log (D) here. Two charred spots face the front
E
C
Position Small End of Log (E) on The Notch of Log (C) Here
11. Place Log (F) as shown in Figure 14.
Log (F) sits in front of the grate
(Valve Access Side)
WARNING
(Valve Access Side)
F
This appliance is not designed to burn wood. Any attempt to do so could cause irreparable damage to appliance and prove hazardous to your safety.
WARNING
If logs are not installed according to the log installation instructions, fl ame impingement and improper combustion could occur and result in soot and/or excessive produc­tion of carbon monoxide (CO), a colorless, odorless, toxic gas.
WARNING
DO NOT attempt to install the logs until the appliance installation has been completed, the gas line con­nected and tested for leaks and the initial burner operation has been checked out.
10
D
Figure 13
Figure 14
WARNING
Logs get very hot and will remain hot up to one hour after gas supply is turned off. Handle only when logs are cool. Turn off all electricity to the appliance before you install grate and logs.
BURNER ADJUSTMENTS (QUALIFIED TECHNICIANS ONLY)
If the air shutter openings closed too far, sooting may develop. Sooting is indicated by black puffs developing at the tips of very long orange fl ames. Sooting results in black deposits forming on the logs, appliance inside surfaces and on exterior surfaces adjacent to the vent termination. Sooting is caused by incomplete combustion in the fl ames and lack of combustion air entering the air shutter opening. To achieve a warm yellowish-orange fl ame with an orange body that does not soot, the shutter opening must be adjusted between these two extremes.
Air Shutter Adjustment Guidelines
• If there is smoke or soot present, fi rst check the log set positioning to ensure that the fl ames are not impinging on any of the logs. If the log set is properly positioned and a sooting condition still exists, then the air shutter opening should be increased.
• The more offsets in the vent system, the larger the air shutter opening will need to be.
• An appliance operated with the air shutter opened too far, may have fl ames that appear blue and transparent. These weak, blue and transparent fl ames are termed anemic.
• Propane models may exhibit fl ames which candle or appear stringy. If this is present and per­sists, adjust the air shutter to a more closed position, then operate the appliance for a few more minutes to ensure that the fl ame normalizes and the fl ames do not appear sooty.
Flame Appearance & Sooting
Proper fl ame appearance is a fl ame which is blue at the base and becomes yellowish-orange in the body of the fl ame. When the appliance is fi rst lit, the entire fl ame may be blue and will gradually turn yellowish-orange during the fi rst 15 minutes of operation. If after period the fl ame stays lowered blue, or if the fl ame is orange with evidence of sooting (black tip), the air shutter opening may need to be adjusted.
The following chart is provided to aid you in achieving the correct air shutter adjustment for your installation.
Air Shutter Adjustment Guidelines
Amount of
Primary Air
If air shutter is closed too far
If air shutter is open too far
Flame
Color
Flame will be orange
Flame will be blue
WARNING
Air shutter adjustment should only be performed by a qualifi ed professional service technician.
WARNING
Ensure front glass panels are in place and sealed during adjust­ment.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Figure 15 *- Burner Flame Appearance
Vermiculite
CAUTION
The air shutter door and nearby
:
Air Shutter
Adjustment
Air shutter gap should be increased
Air shutter gap should be decreased
appliance surfaces are hot. Exer­cise caution to avoid injury while adjusting fl ame appearance.
CAUTION
Carbon will be produced if the air shutter is closed too much. Any damage due to carboning result­ing from improperly setting the air shutter is not covered under the warranty.
Burner Air Shutter Adjustment Procedure
1. Locate adjustment rod and adjust air shutter
to the standard setting as shown in Figure 16 (adjustment rod is located in the lower
control area). Note: Rotating the adjustment rod counterclockwise decreases air and clockwise increases air.
Page 11
2. Light appliance (follow lighting procedure on
lighting label in control compartment or see homeowners manual).
3. Allow the burner to operate for at least 15 min-
utes while observing the fl ame continuously to ensure that the proper fl ame appearance has been achieved (see Figure 15). If the following conditions are present, adjust accordingly.
• If flame appears weak or sooty, adjust the
Main Burner Factory Air Shutter
Opening Setting - All Models
Model Natural
Gas
MPB35ST
1/8”
3.2mm
Propane
Gas
1/4”
6.4mm
Decrease Shutter Opening In This Direction
Orifi ce
air shutter, incrementally, to a more open position until the proper fl ame appearance is achieved.
• If fl ame stays lowered blue, adjust the air shutter, incrementally, to a more closed position until the proper fl ame appearance
Figure 16
Adjustment Rod Positions (when viewed from above)
Air Shutter Adjusting Rod
Increase Shutter Opening In This Direction
is achieved.
4. Leave the control knob (off/pilot/on) in the ON position and the burner OFF/ON switch OFF (& remote switches, if applicable).
5. When satisfi ed that the burner fl ame appearance is normal, close the lower control compartment door.
MAINTENANCE SCHEDULE - Annually (Before the onset of the Burning Season)
MAINTENANCE TASK ACCOMPLISHING PERSON PROCEDURE
Note - Burners are
omitted in this
view for clarity.
Inspecting/Cleaning Burner, Logs and Controls
Qualifi ed Service Technician Inspect valve and ensure it is properly operating. Check piping
for leaks. Vacuum the control compartment, fi replace logs and burner area.
Check Flame Patterns and Flame Height
Qualifi ed Service Technician
Refer to Figure 15 on Page 13 and verify the fl ame pattern and height displayed by the appliance conforms to the picture. Flames must not impinge on the logs. Ensure fl ames are steady (not lifting or fl oating).
Inspecting/Cleaning Pilot and Burner Qualifi ed Service Technician
Refer to Figure 17 and Figure 18 on Page 14. Remove any surface build-up on pilot and burner assembly. Wipe the pilot nozzles, igniter/fl ame rod and hood. Ensure the pilot fl ame engulfs the fl ame sensor as shown.
Checking Vent System Qualifi ed Service Technician Inspect the vent system at the top and at the base (within the
fi rebox) for signs of blockage or obstruction. Look for any signs of dislocation or deterioration of the vent components. Note: Inspect wall straps or plumbers's tape to ensure it is secure and in place.
Appliance Checkout Qualifi ed Service Technician Perform the appropriate appliance checkout procedure detailed
in this manual.
Replacing Rockwool Ember Materials Homeowner/Qualifi ed Service
Technician
Remove old ember materials (rockwool) and vacuum the ember placement area. Place new embers as described in Step 6 on Page 11.
MAINTENANCE SCHEDULE - Periodically (After the Burning Season)
MAINTENANCE TASK ACCOMPLISHING PERSON PROCEDURE
Cleaning Firebox Interior Homeowner Carefully remove logs, embers (rockwool), and vermiculite.
Check Flame Patterns and Flame
Homeowner
Height
Checking Vent System Homeowner Inspect the vent system at the top and at the base (within the
Cleaning Front Glass Enclosure Panel Homeowner Clean as necessary following the directions provided in this
Vacuum out interior of the fi rebox. Clean fi rebox walls and log grate. Replace logs, embers (rockwool) and vermiculite as detailed in this manual (see Pagexs 8-10 ).
Refer to Figurex 15 on Pagex 10 and verify the fl ame pattern and height displayed by the appliance conforms to the picture. Flames must not impinge on the logs.
fi rebox) for signs of blockage or obstruction. Look for any signs of dislocation of the vent components.
manual. DO NOT TOUCH OR ATTEMPT TO CLEAN GLASS WHILE HOT.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
11
Page 12
TROUBLESHOOTING
Note: Before troubleshooting the gas control system, Ensure external gas shut off valve, located at gas supply inlet, (and wall switch, iff applicable), is in the “ON” position. Important: Valve system troubleshooting should only be accomplished by a qualifi ed service technician.
TROUBLESHOOTING GUIDE - MILLIVOLT GAS CONTROL SYSTEM
SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION
1. Spark igniter will not light pilot after
repeated triggering of igniter button.
2. Pilot will not stay lit after
carefully following the lighting instructions.
3. Pilot burning, no gas to burner, Valve
knob “ON,” and the (standard) burner OFF/ON switch is “ON." Read impor­tant note below.
IMPORTANT NOTE: If an optional
*remote switch is used for burner operation, the standard burner OFF/ON switch on appliance must be in the "OFF" position.
*Optional remote switch kits - wall
switch or remote control.
4. Frequent pilot/burner outage prob-
lem.
A. Defective igniter (no spark at electrode).
B. Defective or misaligned electrode at pilot
(spark at electrode).
C. Gas supply pressure errant.
D. Pilot orifi ce plugged.
A. Defective pilot generator
(thermocouple).
A. Manual Reset Spill Switch has Tripped or is
defective.
B. Wall switch or wires defective.
C. Thermopile may not be generating suf-
fi cient millivolts.
D. Plugged burner orifi ce.
E. OFF/ON Switch & *Remote Switch are in
the "ON" position resulting in excessive resistance.
A. Pilot fl ame may be too low or blowing (high)
causing the pilot/valve safety to drop out.
Check for spark at electrode and pilot; if no spark and electrode wire is properly connected, replace igniter.
Using a match, light pilot. If pilot lights, turn off pilot and trigger the igniter button again. If pilot lights, an improper gas mixture caused the bad lighting and a longer purge period is recommended. If pilot will not light – check gap at electrode and pilot – should be 1/8" to have a strong spark. If gap measures 1/8", replace pilot (see Figure 17 on Page 14).
Check inlet gas pressure. It should be within the limits as marked on the rating plate.
Clean or replace pilot orifi ce.
Check pilot fl ame, it must impinge on thermocouple (see Figure 17 on Page 14). Clean and/or adjust pilot for maximum fl ame impingement on thermocouple. Ensure that the connection between the valve and thermocouple are tight and secure.
Follow Manual Reset procedure on Page 6. Once the red reset button is fully depressed and clicks in, check continuity with a multimeter between switch terminal (Ohms). If it shows an open circuit, replace switch.
Check wall switch and wires for proper connections. Jumper wire across terminals at wall switch, if burner comes on, replace defective wall switch. If okay, jumper wires across wall switch wires at valve, if burner comes on, wires are faulty or connections are bad.
Check thermopile with millivolt meter. Take reading at thermopile terminals of gas valve. Should read 325 millivolts minimum with optional wall switch “OFF.” Replace faulty thermopile if reading is below specifi ed minimum.
Check burner orifi ce for blockage and remove.
When turning on the burner using a *remote switch, ensure that the standard OFF/ON switch is in the "OFF" position. If both switches are in the ON position, it may result in excessive resistance (& millivolt drain­age) and the burner may not come on.
Clean and/or adjust pilot fl ame for maximum fl ame impingement on thermocouple (see Figure 19 on
Page 20).
TROUBLESHOOTING GUIDE - ELECTRONIC IGNITION SYSTEM
SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION
1. Burner will not light. A. Faulty Valve System.
2. Burners come “ON,” then turns “OFF.” A. Burner orifi ce plugged.
12
B. “OFF/ON” or wall switch defective.
B. Obstructed vent system.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
See Below.
Disconnect the two black wires from the wire nuts. Test switch(s) for continuity with a multimeter. If continuity is not indicated, switch(s) is defective and must be replaced.
Note: Before replacing “OFF/ON” switch, Ensure to check wiring for loose connections or broken wires and repair as needed.
Check main burner orifi ce(s) for blockage. Clean or replace.
Check vent system for obstructions.
Page 13
TROUBLESHOOTING PROCEDURE - ELECTRONIC IGNITION SYSTEM
START CHECK
• Turn Off Gas Supply.
• Ensure Valve Switch Is In ON Position.
• Disconnect Control Harness.
• Set Thermostat To Call For Heat.
Insert A
End View of Control Harness Connector
• Check for proper volt­age at control harness (see insert A). Voltage
2
should be 24V between thermostat or pressure switch and 24V common and 24V hot.
YES
• Plug control harness into valve. Wait for internal check delay.
NO
• Line voltage power
• Low voltage transformer
• Limit controller
• Thermostat
• Wiring
24 Volt Hot
24 Volt
Switched
Check For Damaged or Missing Terminals in Connector
Insert B
Igniter Terminals
Common
24 Volt
• With pilot burner cable con-
1
• Igniter warms up and glows red.
YES • Replace igniter/fl ame rod
1
• Turn on gas supply.
• Pilot burner lights.
YES
• Main valve opens and main burner lights.
YES YES
• System Is okay. • Cycle thermostat off and back on.
NO
NO
NO
nected, measure voltage at valve HSI element output. 24V
2
nominal. (See insert B)
YES
assembly.
YES
• Check that pilot gas is fl owing. Wait to ensure pilot gas tubing is purged. Recycle call for heat if necessary.
YES
• Measure voltage between 24V hot and 24V common leads to valve control. Must measure at least 19.5 VAC with igniter powered (see insert A). To identify proper lead, this check must be done with the valve control con­nected and igniter powered.
YES
• Replace Pilot Assembly.
• Check that pilot fl ame makes good contact with pilot burner fl ame rod.
• Check for good electrical connection through the pilot tubing.
• If both of the above are good, replace igniter/fl ame rod assembly.
NO
• Replace valve.
NO
• Replace valve.
• Check transformer and
NO
line volt supply.
Igniter will cycle off and
1
back on once during the 90 second ignition trial. All voltage measurements must be taken while the igniter is powered.
When measuring voltage
2
at connections, use care to ensure terminals are not damaged.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
13
• Main burner lights.
NO
• Replace valve.
13
Page 14
Millivolt Appliance Checkout
The pilot fl ame should be steady, not lifting or fl oating. Flame should be blue in color with traces of orange at the outer edge.
The top 3/8" (10 mm) at the pilot generator (thermopile) and the top ¹⁄₈" min (tip) of the quick drop out thermocouple should be engulfed in the pilot fl ame. The fl ame should project 1" (25 mm) beyond the hood at all three ports. See Figure 17.
To light the burner, refer to the lighting instruc­tions on Page 18.
MILLIVOLT PILOT ASSEMBLY
Proper Pilot Flame Appearance
Thermocouple
Pilot Nozzels
Figure 17
Hood
Thermopile
Igniter Rod
3/8" Min.
(9 mm)
Electronic Appliance Checkout
To light the burner, refer to the lighting instruc­tions on Pagex 19. Ensure the igniter lights the pilot. The pilot fl ame should engulf the fl ame sensor as shown in Figurex 18.
ELECTRONIC PILOT ASSEMBLY
Proper Pilot Flame Appearance
Proper Flame
Adjustment
Pilot Nozzels
3/8" to 1/2"
(9 -13 mm)
Ground
Electrode
Flame Rod
Hot Surface
Igniter
Figure 18
With proper care and maintenance, your appliance will provide many years of enjoyment. If you should experience any problem, fi rst refer to the trouble shooting guide in this manual. If problem persists, contact your Lennox distributor.
Electronic Wiring Diagram (Honeywell)
1. If any of the original wire as supplied must be replaced,
1. it must be replaced with Type AWM 105°C – 18 GA.
wire.
2. 120V, 60Hz – Less than 3 amps.
*ON/OFF Switch (Integral
with Gas Valve)
Gas Valve
BK
R
BL
*Leave the ON/OFF switch, which is integral
with the gas valve, in the ON position.
Outlet Box Green
Ground Screw
PILOT
ASSEMBLY
IGNITER
G
BK W
120
VAC.
WARRANTY
Your gas appliance is covered by a limited twenty year warranty. You will fi nd a copy of the war­ranty accompanying this manual. Please read the warranty to be familiar with its coverage.
Retain this manual. File it with your other docu­ments for future reference.
REPLACEMENT PARTS
A complete parts list is found at the end of this manual. Use only parts supplied from the
G
White Wire
To Opposite
Side
Junction Box
W
B
G
Hot side of Outlet
BL
WT
SPILL SWITCH
(high limit disc)
R
WT
Transf.
120 V.
24 V
BK
* Optional Control Switches - OFF/ON wall switch or remote control receiver.
Schematic Represen­tation Only
Figure 19
Field Wired
Factory Wired
manufacturer. Normally, all parts should be ordered through your Lennox distributor or dealer. Parts will be shipped at prevailing prices at time of order.
When ordering repair parts, always give the following information:
1. The model number of the appliance.
2. The serial number of the appliance.
3. The part number.
4. The description of the part.
5. The quantity required.
6. The installation date of the appliance.
If you encounter any problems or have any ques­tions concerning the installation or application of this system, please contact your distributor, or Lennox directly:
LENNOX HEARTH PRODUCTS
1110 West Taft Avenue Orange, CA 92865
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS APPLIANCE OPERATION.
Millivolt Wiring Diagram
If any of the original wire as supplied must be replaced, it must be replaced with Type
Schematic Represen­tation Only
White
TP
TP
TH
AWM105 C - 18 gage wire.
* Optional Control Switches - OFF/ON wall switch or remote control receiver.
Note: Turn the appliance-mounted OFF/ON burner control switch to the OFF position if an optional control switch is installed.
* Optional Control Switch
Figure 20
Thermopile
Spill Switch
White
Black
Appliance mounted OFF / ON Switch
TH
Field Wired
Factory Wired
PRODUCT REFERENCE INFORMATION
We recommend that you record the following important information about your fi replace. Please contact your Lennox dealer for any questions or concerns. For the number of your nearest Lennox dealer, please call 800-731-8101
Your Fireplace's Model Number ________________________________________
WIRING DIAGRAMS
Wiring diagrams are provided here for refer­ence purposes only. This information is also provided on schematics attached directly to the appliance on a pullout panel located within the control compartment.
14
Your Fireplace's Serial Number ________________________________________
The Date On Which Your Fireplace Was Installed ___________________________
The Type of Gas Your Fireplace Uses ____________________________________
Your Dealer's Name ________________________________________________
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Page 15
ACCESSORY COMPONENTS
P
A
I
N
T
Product Reference Information
Cat.
No.
H3201 MPD35ST-NM 220 lbs 46W x 26D x 43H
H3202 MPD35ST-PM 220 lbs 46W x 26D x 43H
H3203 MPD35ST-NE 220 lbs 46W x 26D x 43H
Model Ship.
Weight
Ship.
Volumn
(30 cu.ft.)
(30 cu.ft.)
(30 cu.ft.)
Bag of Glowing Embers Bag of Volcanic Stone
Replacement ember materials or volcanic stone are available for use with these appliances. Order kits as part of the periodic maintenance of the appliance.
3 Piece Trim Kit
Cat. No. Model No. Description
96K21 TK35PB3 35” 3 Piece Finish Trim Kit,
Polished Brass
(ref. Form # 750,147M)
Polished Brass 3-Piece Trim Kit
Remote Control Kit, Standard
Cat. No. Model No. Description
H0249 RCL Remote Control System
(Standard)
(ref. Form # 750,127M)
Standard Remote Control System
The Model RCL (Standard) Remote Control System, features a simplistic OFF/ON control function for the fi replace. This model includes a hand-held transmitter, a remote receiver with wall-mount cover plate and all hardware required to install the unit. The remote receiver can be wall or hearth mounted.
The transmitter has ON and OFF functions that are activated by pressing either button on the face of the transmitter. When a button on the transmitter is pressed, a signal light illuminates briefl y to verify that a signal has been sent.
Decorative Firebox Accessories
Cat. No. Model No. Description
88L53 FGE Bag of Glowing Embers
80L42 FDVS
(FDVS ref. Form #750,010M)
Cat. No. Model No. Description
85L87 FWSK OFF/ON Wall Switch Kit
(1 oz. rockwool)
Bag of Decorative Volcanic Stone
White Wall Switch Kit
This kit contains brass trim pieces used to fi nish the gaps between the wall board and the fi replace, providing the appliance a brass perimeter highlight. This kit contains the trim pieces and these instructions.
4 Piece Trim Kit
Cat. No. Model No. Description
96K17 TK35PB4 35” 4 Piece Finish Trim Kit,
Polished Brass
(ref. Form # ii-9299)
The Model RCL is designed to operate with all millivolt ignition systems, as well as electronic ignition systems. It may be installed with use for either natural or propane gas appliances. The RCL offers ease of installation and allows you to execute on-off commands to the fi replace effortlessly with one simple motion.
The Model RCL comes complete with detailed operating instructions.
OFF/ON Wall Switch Kit
The OFF/ON wall switch kit may be used to control the operation of the fi replace burner. Install the OFF/ON wall switch in a convenient location near the fi replace.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Touch-Up Paint Kits
Cat. No. Model No. Description
90L74 TPK-C Touch-Up Paint (Charcoal)
98K67 TPK-T Touch-Up Paint (Tan)
(TPK-C ref. Form # 504,216M)
Touch-Up Paint Kit
Repair of minor scratches and discoloration of the appliance charcoal painted surfaces may be accomplished with the touch-up paint kit.
15
Page 16
ACCESSORY COMPONENTS
Arch Pane Design
Arch Design
Square Pane Design
Style View Doors -
Style View Doors come in 4 beautiful styles. They are easy to install and will not require hardware to attach them to the standard glass door frame. The door includes heavy duty magnet door latches and functional twin-pane doors.
Arch Pane Design Kits
H0930 APD35C 35” Arch Pane Doors, Char.
H0931 APD35TI 35” Arch Pane Doors, Text. Iron
H0932 APD35SP 35” Arch Pane Doors, Satin Pew.
H0933 APD35AB 35” Arch Pane Doors, Ant. Brass
Arch Design Kits
Cat. No. Model Description
H0858 AD35C 35” Arch Doors, Charcoal
H0859 AD35TI 35” Arch Doors, Textured Iron
H0860 AD35SP 35” Arch Doors, Satin Pewter
H0861 AD35AB 35” Arch Doors, Antique Brass
Square Design Kits
Cat. No. Model Description
H0946 SD35C 35” Sq. Doors, Charcoal
H0947 SD35TI 35” Sq. Doors, Textured Iron
H0948 SD35SP 35” Sq. Doors, Satin Pewter
H0949 SD35AB 35” Sq. Doors, Antique Brass
Square Pane Design Kits
H0962 SPD35C 35” Sq. Pane Doors, Char.
H0963 SPD35TI 35” Sq. Pane Doors, Text. Iron
H0964 SPD35SP 35” Sq. Pane Doors, Satin Pew.
H0965 SPD35AB 35” Sq. Pane Doors, Ant. Brass
(ref. Form # 775,169M)
16
Square Design
Clean Face Charcoal Radiant Panel Kits
Cat. No. Model No. Description
88L36 RAD35C-2 Clean Face Panel Kit
(ref. Form # 504,223M)
Clean Face Panel Kits
Clean faced panel kits are available to convert the standard louvered fi replaces to radiant models which are more suited for fi nishing around the fi rebox opening with non-combustible materi­als, such as tile.
Brickaded Wall Liner Kits
Cat. No. Model No. Description
H3207 MBLK-35ST Interior Brick Liner Kit
(ref. Form # 750,160M)
Brickaded Panel Liner Kit
The brickaded liner kits include ceramic panels as shown here. The panels have brick-like features in relief.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
35" Screen Heat Guard Kit
Cat. No. Model No. Description
26M48 HG35M 35" Screen Heat Guard Kit
(ref. Form # 750,101M)
Screen Heat Guard Kit
This easy to install optional screen heat guard installs over the standard glass enclosure panel to provide protection from the hot glass surface. These screen heat guard panels cannot be used in conjunction with the arch door kits or door frame kits. Order 2 if a set is desired (for front face and rear face glass surfaces).
4 Piece Door Trim Kits
Cat. No. Model No. Description
26M82 4DFK35PB Door Trim, Polished Brass
26M85 4DFK35BS Door Trim, Brushed Stainless
(ref. Form # 750,098M)
Door Frame Kits
A decorative door frame kit is available for use with these appliances. It is designed to attach directly to the front face of the appliance at the four edges of the glass enclosure panel resulting in the appearance of a picture frame.
Page 17
ACCESSORY COMPONENTS
* 35" Arch Door Kits
Cat. No. Model No. Description
26M43 ADK35CMPB Arch Door, Polished Brass
26M44 ADK35CMBS Arch Door, Brushed Stainless
(ref. Form # 750,021M)
Arch Door Kits
Two types of arch door kits are available for the Multi-Open Series. Both types of kits are easy to install and do not require hardware to attach them to the standard door frame. These kits can be retrofi tted to previously installed Multi-Open Series appliances. The decorative arch kits can not be used in conjunction with the screen panel kit.
* 35" Eyebrow Hood Kits
Cat. No. Model No. Description
96K67 EB35PB
88L49 EB35BS
* These hood kits replace the standard hood that comes with these fi replaces.
(ref. Form #504,142M)
Hood Kit, Polished Brass
Hood Kit, Brushed Stainless
Polished Brass and Brushed Stainless Hood Kits
Attractive hoods are available in two styles to be used on the Multi-Open Series appliances. These hoods are designed to be fi tted to the glass viewing sides of the appliance. In addition to providing an aesthetically pleasing appearance to your appliance installation, the hood reduces heat effects to decorative mantles and fi nish materials located above the fi replace opening. The hood kit replaces the standard hood that comes with these appliances and snaps into place. These kits can be retrofi tted to previously installed appliances.
2-Piece Louver Kits
Cat. No. Model No. Description
96L05 2LVR35PB
96L09 2LVR35BS
(ref. Form # 504,224M))
2 Pc. Louver Kit, Polished Brass
2 Pc. Louver Kit, Brushed Stainless
2-Piece Polished Brass and Brushed Stainless Louvers Kits
These louvers are designed to replace either the middle charcoal louver of each set or the charcoal louver in each set closest to the glass door. These kits include two narrow louvers. They provide a touch of elegance to these appliances. These kits can be retrofi tted to previously installed appliances.
Outside Combustion Air Kits
Cat. No. Model No. Description
81L87 FOAK-4 Combustion Air Kit (with
duct)
81L88 FOAK-4LD Combustion Air Kit
(without duct)
(ref. Form # 750,008M)
Outside Air Kits Models FOAK-4 and FOAK-4LD
Outside Air kits are available with duct (FOAK-4) and without duct (FOAK-4LD) for use if outside combustion air is required or desired. If model FOAK-4LD is used it must be used in conjunction with locally purchased, non-combustible Class 1 or Class 0 fl exible duct.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
35" Assembled Louver Kits
Cat. No. Model No. Description
88L28 LVR35PB-2
88L32 LVR35BS-2
(ref. Form # 750,119M)
Louver Kit, Polished Brass
Louver Kit, Brushed Stainless
Polished Brass and Brushed Stainless Louvers Kits
Decorative louvers are available for use with all Multi-Open Series appliances. These louvers are designed to replace the standard radiant panels that are provided with the appliance. These kits include a top 3-piece assembly and a bottom 3-piece assembly. They provide a touch of elegance to any Multi-Open Series appliance. These kits can be retrofi tted to previously installed appliances.
17
Page 18
LIGHTING INSTRUCTIONS – MILLIVOLT GAS VALVE
it
OUT
IN
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
A. This appliance has a pilot which must be lit with a piezo
igniter. When lighting the pilot, follow these instructions exactly.
B. BEFORE OPERATING smell all around the appliance area for
gas. Ensure to smell next to the fl oor because some gas is heavier than air and will settle on the fl oor.
WHAT TO DO IF YOU SMELL GAS
Extinguish any open fl ame.
Open windows.
Do not light any appliance.
Do not touch any electrical switches.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above on this page.
2. Access the lower control compartment.
3. Turn OFF/ON switch to “OFF” (and remote wall switch, if appli-
cable).
4. Verify main line shut-off valve is open.
5. Push in gas control knob slightly and turn clockwise
to “OFF.”
SIT Millivolt Gas Valve
IN
PIEZO
IGNITER
OUT
F
F
O
P
I
L
it
O
T
O
N
GAS CONTROL KNOB
TP/TH
TP
TH
TPTH TP TH
BURNER
OFF/ON SWITCH
I
H
L
W
O
P
I
L
O
T
- LO / HI +
Do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s
phone.
If your gas supplier cannot be reached, call the fi re depart-
ment.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualifi ed service technician. Force or attempted repair may result in a fi re or an explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualifi ed service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
6. Wait fi ve (5) minutes to clear out any gas. If you then smell gas,
STOP! Follow “B” in the safety information above on this page. If you do not smell gas, go to the next step.
7. Push in gas control knob slightly and turn counterclockwise
to “PILOT.”
8. Push in control knob all the way and hold in. Immediately light the
pilot by triggering the spark igniter (pushing the button) until pilot lights. Continue to hold the control knob in for about 1 1/2 minutes after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.
If knob does not pop up when released, stop
and immediately call your service technician or gas supplier.
If pilot will not stay lit after several tries, turn the control knob to “OFF” and call your service technician or gas supplier.
Millivolt Pilot
9. Turn gas control knob counterclockwise to “ON.”
10. Close lower control compartment.
ON
OFF
Note: Knob cannot be turned from “PILOT” to “OFF” unless the knob is pushed in slightly. Do not force.
1. Turn remote wall switch “OFF.” The pilot will remain lit for
normal service.
2. For complete shutdown, turn remote wall switch to “OFF.”
3. Access the lower control compartment.
18
TO TURN OFF GAS TO APPLIANCE
4. Depress gas control knob slightly and turn clockwise
to “OFF.” Do not force.
5. Close lower control compartment.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Page 19
LIGHTING INSTRUCTIONS — ELECTRONIC
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
A. When lighting the appliance, follow these instructions
exactly.
B. BEFORE OPERATING smell all around the appliance area
for gas. Be sure to smell next to the fl oor because some gas is heavier than air and will settle on the fl oor.
WHAT TO DO IF YOU SMELL GAS
Extinguish any open fl ame.
Open windows.
Do not light any appliance.
Do not touch any electrical switches.
Do not use any phone in your building.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above on this page.
2. Turn remote wall switch to “OFF.”
3. Open lower control compartment door.
4. Verify main line shut-off valve is open.
Honeywell Electronic Gas Control Valve
ON / OFF Switch
C O N T R
NO
O
FFO
L
I
G N I
T ER
Front View
NI
I S P
Immediately call your gas supplier from a neighbor’s
phone.
If your gas supplier cannot be reached, call the fi re
department.
C. Use only your hand to turn the gas control lever. Never
use tools. If the lever will not turn by hand, do not try to repair it, call a qualifi ed service technician. Force or attempted repair may result in a fi re or an explosion.
D. Do not use this appliance if any part has been under
water. Immediately call a qualifi ed service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
5. Turn the OFF/ON switch to “OFF”. Do not force.
6. Wait fi ve (5) minutes to clear out any gas. If you then
smell gas, STOP! Follow “B” in the safety information above on this page. If you do not smell gas, go to the next step.
7. Turn the OFF/ON switch to “ON”. Do not force.
8. Turn “ON” all electrical power to appliance (remote wall
or appliance switch).
9. Close lower control compartment door.
TO SHUT OFF
1. Turn off all electrical power to the appliance (remote wall
switch).
1. For complete shut-down, turn remote wall switch to
“OFF.”
2. Open lower control compartment door.
TO TURN OFF GAS TO APPLIANCE
3. Turn the OFF/ON switch to “OFF”. Do not force.
4. Close the main line shut-off valve.
5. Close lower control compartment door.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
19
Page 20
REPLACEMENT PARTS - MPB35ST
Item Part/Cat. Qty Description Where Used
SIT Millivolt Only
1 H3357 1 Gas Train Assembly, NG, MV MPB35ST-NM
1 H3355 1 Gas Train Assembly, LP, MV MPB35ST-PM
Honeywell Electronic Only
2 H3356 1 Gas Train Assembly, NG, Elecrtr. MPB35ST-NE
3 LB-97493 1 Transformer
Misc. Replacement Parts
4
5
6
7
H3351
H3352
H3353
LB-91941B
Brickaded Side Panels All
2
Burner, Pan All
1
*Electrical kit All
1
Eyebrow Panel All
2
8 93L32 1 Flex Line Gas Connector, FFGC All
LB-92398B
9
88L53 Glowing Embers (1 oz.), FGE
10
2 Glass Enclosure Assembly All
11 H3358 1 Grate Assembly All
12 69L2101 4 Latch, Glass Enclosure Panel All
H3354
13
Note: Ordering information for Volcanic Stone, Glowing Embers and Touch-up Paint can be found on Page 15
Firebox Sub-fl oor All
1
MPB35ST-NE &
MPB35ST-PE
All
Item Part/Cat. Qty Description Where Used
Misc. Replacement Parts
14
H3210
15 LB-92449B 2
16 LB-92652B 1
1 Log Set All
Louver Assembly, Upper Charcoal
Louver Assembly, Lower, Charcoal (valve access side)
All
All
17 H3359 1 Louver Assembly, Lower, Char. All
18 69L3101 2 Magnet, Latch, Spring-Loaded All
19 94326 2 Magnet All
20 LB-95668 8 Nailing Flange
All
21 12L15 2 Nameplate, Lennox All
24M1001
22
1 Orifi ce, Burner, NG, #37 (.104") MPB35ST-NM &
MPB35ST-NE
42M7901
22
23 111061 1 Piezo Igniter
1 Orifice, Burner, LP, 1.55mm
(.061")
MPB35ST-PM &
MPB35ST-PE
MPB35ST-NM &
MPB35ST-PM
24 27K30 1 Switch, OFF/ON, Rocker All
10 42363 1 Vermiculite, Bag (2 liters) All
* Electrical Outlet Kit consists of a junction box, 2 screws, an receptacle outlet, an OFF/ON rocker switch and a snap bushing. Note: All the components in the electrical kit will Not be used by every model.
4
7
15
7
15
20
6
9
11
16
13
21
5
12
18
19
22
1
24
23
9
17
22
2
8
10
3
8
14
Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifi cations, prices and also to discontinue colors, styles and products. Consult your local distributor for fi replace code information.
Printed in U.S.A. © 2005 by LENNOX HEARTH PRODUCTS
20
P/N 875,024M REV. NC 04/2005
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
1110 West Taft Avenue • Orange, CA 92865
Loading...